Inspection history · 46
20 March 2025
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8097075
15 November 2024
Internal Structural Exam · Administrative Inspection · COI Inspection · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8035238
22 December 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7862298
8 March 2023
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7648210
20 June 2022
Deficiency Check · Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7483197
3 May 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7433009
13 May 2021
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7196293
31 January 2020
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6900143
18 December 2018
Type not recorded
No type recorded · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6599485
9 November 2017
DAPI Audit
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6307508
21 December 2016
Administration
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6061069
1 June 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5177988
4 June 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4034267
18 March 2010
Industry Initiated Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3704621
3 December 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3373959
16 July 2008
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3269971
5 July 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3277817
6 April 2008
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3180523
7 August 2007
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3020479
7 May 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2924466
4 April 2007
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2901326
4 April 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2901328
3 April 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2924326
5 July 2006
MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2719121
18 October 2004
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2223322
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1976225
23 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1984546
12 December 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1963129
28 April 2002
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1615073
17 January 2002
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1479517
15 January 2002
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1478942
8 February 2001
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1522356
30 October 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 210942
30 October 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 434283
30 October 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 771529
2 September 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 89178
24 October 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 10319
2 September 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 127061
10 July 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 16306
9 May 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 21442
9 May 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 366732
26 May 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 120634
24 September 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 669543
24 September 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 669546
21 August 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 669544
14 August 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 81101
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 April 2025
Resolved
Each life jacket must have a life jacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the life jacket.
08 attached Life jacket lights on board beyond the expiration date. Renew expired life jacket lights.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2025
Resolved 1 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 7 April 2025
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Install/ correct emergency lighting or phosphorescent adhesive lighting strips along escape hatches/doorways within engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2025
Resolved 1 May 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 April 2025
Resolved
All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months.
Provide fire equipment test records.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2025
Resolved 1 May 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 March 2025
Resolved
A towing vessel may not be operated without having on board a valid COI issued by the Coast Guard as required by § 136.202. Owners and managing operators must submit Form CG-3752, “Application for Inspection of U.S. Vessel,” to the cognizant OCMI where the inspection will take place. The owner or managing operator must submit the application at least 30 days before the vessel will undergo the inspection for certification. As well as, Any changes to the vessel or manning and a description of any modifications to the vessel. Vessels COI expired 06FEB2025.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 March 2025
Resolved
A vessel that is exposed to salt water less than 6 months in any 12-month period since the last examination or initial certification must undergo a drydock and internal structural examination at least once every 5 years. The Dry Dock and Internal Structural Exam were due NLT 28FEB2025
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 November 2024
Resolved
The following systems must be equipped with gauges at the machinery location. The STBD generator's installed RPM gauge was not operational. Repair or replace generator RPM at the machinery location.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2025
Resolved 1 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 March 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Inspection found the safety relief valve on the water heater in the engine space had been sealed with a plug, therefore not allowing blow-off relief in the event of over pressurization potentially causing a serious risk to crew and vessel. Remove plug and replace the hot water heater safety device in accordance with the manufactures recommendation.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 March 2023
Resolution: The deficiency was cleared to the satisfaction of an USCG Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 8 March 2023
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Inspection found water raining into the engine room from the 02 topside hatches appearing to be drawn in by the engine room exhaust fans. Further investigation found hatches were not bolted down and did not have seals.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 March 2023
Resolution: The deficiency was cleared to the satisfaction of an USCG Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 March 2023
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Inspection found 02 exterior weathertight doors (port & starboard) on the second deck had damaged seals and light leaking through.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 March 2023
Resolution: The deficiency was cleared to the satisfaction of an USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 March 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Wires in electronics space under the bridge were overhanging the steering equipment and chaffing. 46 CFR 143.400
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 March 2023
Resolution: The deficiency was cleared to the satisfaction of an USCG Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 March 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Inspection found electrical junction box inside port engine room door had exposed wires and no cover plate.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 March 2023
Resolution: The deficiency was cleared to the satisfaction of an USCG Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 March 2023
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size
of the crew and operating conditions. Several contents
in the first aid kit were expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2023
Resolved 13 March 2023
Resolution: The deficiency was cleared to the satisfaction of an USCG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 March 2023
Resolved
Each lifebuoy on a towing vessel must be approved under
approval series 160.050 or 160.150. Inspection found
deteriorated retro-reflective tape on the lifebuoys.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 23 March 2023
Resolution: The deficiency was cleared to the satisfaction of an USCG Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 March 2023
Resolved
Each towing vessel must be equipped with at least two portable, battery-powered lights. One must be located at the access to the engine room. The portable light in the E/R was not in place.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2023
Resolved 13 March 2023
Resolution: The deficiency was cleared to the satisfaction of an USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 March 2023
Resolved
The following systems must be equipped with gauges at the machinery location: Auxiliary generator engine lubricating oil pressure. The installed gauge for the stbd gen could not give accurate readings due to the internal gauge plate spinning freely.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 23 March 2023
Resolution: The deficiency was cleared to the satisfaction of an USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 March 2023
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use. Inspection found gallons of flammable chemicals located in the 1st deck restroom.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 13 March 2023
Resolution: The deficiency was cleared to the satisfaction of an USCG Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 March 2023
Resolved
Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. Inspection found no e-lighting or photo luminescent tape inside berthing spaces.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2023
Resolved 13 March 2023
Resolution: The deficiency was cleared to the satisfaction of an USCG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 March 2023
Resolved
Inspections and tests of lifesaving equipment must be recorded in the TVR, official logbook, or in accordance with any TSMS applicable to the vessel. Inspection found no record of lifesaving inspections being conducted.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 23 March 2023
Resolution: The deficiency was cleared to the satisfaction of an USCG Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 March 2023
Resolved
The master of a towing vessel must ensure that drills are conducted and instructions are given to ensure that all crewmembers are capable of performing the duties expected of them during emergencies. This includes abandoning the vessel (annually), recovering persons from the water (annually), responding to onboard fires (monthly) and flooding. Inspection found gaps in required drills not including months vessel was inoperable.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 23 March 2023
Resolution: The deficiency was cleared to the satisfaction of an USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 March 2023
Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced. Test and examination procedures must be in accordance with manufacturer's instructions. Each towing vessel must perform the applicable tests in Table 143.245(b) of this section and must be recorded. Inspection found no record of any of.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 23 March 2023
Resolution: The deficiency was cleared to the satisfaction of an USCG Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 8 March 2023
Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards. Through questioning and inspection the MI found the crew showers using river water. River water is pumped into the vessel's integral water tank and is used for showers by crew living onboard. Inspection found the water used to be very dirty and found floating cigarette butts and other debris in the tanks. Company must provide clean potable water to crew for sanitary and safety of health to the crew. Clean potable water must be provided to the crew prior to sleeping onboard.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 13 March 2023
Resolution: The deficiency was cleared to the satisfaction of an USCG Marine Inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 May 2022
Resolved
Each U.S. towing vessel of 26 feet (about 8 meters) or more in length must hold a ship-radio-station license. Vessel holds 2 current/active FCC station licenses; each with a different call signs and MMSI numbers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 3 June 2022
Resolution: Upon review of FCC Web Based search engine; noted vessel holds only one FCC station license.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 3 May 2022
Resolved
Each towing vessel must be fitted with a genral alarm that is capable of notifying persons in any accommodation, work space, and the engine room, and, has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light. Alarm acctuators could not be heard in engine room and there was no flashing red light fixture. (Corrected - FFK)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2022
Resolution: Audio and visual alarms installed in upper and lower engine room
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 3 May 2022
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. The valve must be operable from a safe place outside the space where the valve is installed. Port and starboard generator shutoff valves remote operation failed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2022
Resolution: Reviewed and accepted objective evidence of remote operation of shutoff valves.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 3 May 2022
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. The valve must be installed in the fuel piping directly outside of the fuel oil supply tank. Port and starboard main diesel engine shutoff valves located in vicinity of each engine and not directly outside fuel oil supply tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 15 June 2022
Resolution: Received objective evidence of properly operating remote fuel shut off valves for the main diesel engines.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 May 2022
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use, and, a 40-B portable fire extinguisher must be located near the flammable/combustible storage cabinet. A flammable product was stored below the pilot house (not in a proper location) and a lessor rated portable fire extinguisher was located near the proper storage cabinet. (Corrected - FFK)
Action required: 10 - Deficiency Rectified
Resolved 3 May 2022
Resolution: The flammable product was properly stowed and a properly rated extinguisher was relocated to the vicinity of the storage cabinet; the vessel also met the required complement of required extinguishers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 May 2022
Resolved
Lifeline required to be secured around the body of the lifebuoy (life ring). Lifeline was secured to lifebuoy's grab line. (CORRECTED - FFK)
Action required: 10 - Deficiency Rectified
Due 3 May 2022
Resolved 3 May 2022
Resolution: Lifeline was properly re-attached to body of lifebuoy.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2022
Resolved
Prior to getting underway for the first time on a particular towing vessel, each crewmember must receive a safety orientation covering all topics listed in 46 CFR 140.410(b) and must be documented in TVR or official logbook to include:
The date of the safety orientation or training;
(2) A general description of the safety orientation or training topics;
(3) The name(s) and signature(s) of individual(s) providing the orientation or training; and
(4) The name(s) of the individual(s) receiving the safety orientation or training.
Training for master and crew had not occurred.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2022
Resolution: Reviewed and accepted objective evidences showing completion of required training for all crew members.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2022
Resolved
Prior to assuming duties related to the safe operation of a towing vessel, each (non credentialed mariner) crewmember must receive training to ensure that they are familiar with:
(1) Watchstanding terms and definitions;
(2) Duties of a lookout;
(3) Communication with other watchstanders;
(4) Change of watch procedures;
(5) Procedures for reporting other vessels or objects; and
(6) Watchstanding safety. Training must be properly recorded in the TVR or offical logbook. Non-credentialed crewmember had not receive navigation safety training.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2022
Resolution: Reviewed and accepted objective evidences showing completion of required training for all non-credentialed crew members.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 May 2022
Resolved
A vessel must be operated in such a manner as to afford protection against hazards to life, property, and the environment.
Batteries used to power port & starboard generator starter motors were not stored in a box, nor were there covers over the batteries to prevent an accidental electrical short.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2022
Resolved 13 May 2022
Resolution: Generator batteries properly stored & protected within battery boxes.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 3 May 2022
Resolved
Means must be provided for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Vessel not fitted with means to close engine room fresh air intake and exhaust vents.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 15 July 2022
Resolution: Canvas covers (2) fabricated. Vessel personnel demonstrated satisfactory fit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 May 2022
Resolved
Auxiliary generators must be equipped with RPM gauges at tthe machinery location. Port and starboard generators were not fitted with RPM guages.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 6 September 2022
Resolution: New RPM gauges installed on each generator.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 3 May 2022
Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. Port and starboard propulsion shafts were not properly protected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 13 May 2022
Resolution: Deckplate, properly installed over rotating machinery, is adequate guard.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 3 May 2022
Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. A small section (approximately 8 inches) of insulation on exhaust piping from starboard main diesel engine was missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2022
Resolved 17 May 2022
Resolution: Exhaust pipe properly insulationed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 May 2022
No resolution recorded
No person may operate a non-oceangoing ship of 100 gross tons and above that is fitted with main or auxiliary machinery spaces in the navigable waters of the United States unless:
(1) The ship has at least one pump installed to discharge oily mixtures through a fixed piping system to a reception facility;
(2) The piping system required by this section has at least one outlet that is accessible from the weather deck;
(3) Each outlet required by this section has a shore connection that is compatible with reception facilities in the ship's area of operation; and
(4) The ship has a stop valve for each outlet required by this section. The vessel was not equipped with pump, piping, or valve for discharging oily mixtures. To be corrected by next required dry dock examination (06FEB2025 as per COI).
Action required: 705 - Other - as specified
Due 5 February 2025 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 May 2022
Resolved
The operators of each vessel and facility engaged in the transfer operation shall retain a signed copy of the declaration of inspection (DOI) on board the vessel or at the facility for at least 1 month from the date of signature. DOI for fuel oil transfer conducted within the last month was not on board the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2022
Resolved 13 May 2022
Resolution: Copy of DOI for regulated fuel transfer (within 30 days of the inspeciton) on board vessel.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 May 2021
Resolved
Label zones on the fire panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 27 May 2021
Resolution: MI attended vessel and verified fire zones were labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 13 May 2021
Resolved
Replace cracked light cover in engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 27 May 2021
Resolution: MI attended vessel and verified correction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2021
Resolved
Provide metal cable supports for electrical wires over egress routes.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 27 May 2021
Resolution: MI attended vessel and verified correction.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 May 2021
Resolved
Prove proper operation of smoke detector in pilot house crawl space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 27 May 2021
Resolution: MI attended vessel and verified smoke detector.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 May 2021
Resolved
Provide on board required amount of visual distress signals in proper stowage container.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 17 May 2021
Resolution: Additional flares brought on board prior to end of inspection
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2021
Resolved
Provide lights and whistles on 2 PFDs in Master bunk room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 17 May 2021
Resolution: PFD provisions were brought on board prior to the end of the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2021
Resolved
Provide a light on PFD in the galley.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 17 May 2021
Resolution: PFD light was installed prior to end of inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 13 May 2021
Resolved
Provide on board a valid/ non-expired first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 17 May 2021
Resolution: New first aid kit brought on board prior to end of inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 May 2021
Resolved
Repair leak on port generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 17 May 2021
Resolution: Port where oil was leaking from was plugged off prior to end of inspection.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 6 February 2020
Resolved
Prove proper operation of vital systems and required alarms on emergency power, including fire panel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2020
Resolution: Verified operation of vital systems and alarms on emergency power.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 February 2020
Resolved
Permanently mount B-V semi-portable fire extinguisher in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2020
Resolution: Verified B-V permanently affixed in engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 February 2020
Resolved
Prove life line for bridge starboard life buoy meets requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2020
Resolution: Verified starboard life buoy life line was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 February 2020
Resolved
Prove that the grab line on the bridge starboard life buoy meets the requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2020
Resolution: Verified starboard buoy grab line was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 6 February 2020
Resolved
Install adequate protection against hot piping on starboard main engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2020
Resolution: Verified installation of lagging on starboard main engine piping.
09 - Working and Living Conditions › 092 - Working Conditions › Stowage of cargo
Issued 6 February 2020
Resolved
Secure flammable storage locker to the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2020
Resolution: Verified flammable storage locker secured for sea.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 6 February 2020
Resolved
Install adequate fall overboard protection near bow on port and starboard side.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 May 2020
Resolution: Installed wire rope and chains to prevent falls overboard.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 February 2020
Resolved
Prove operation of emergency light in 01 deck passageway.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 May 2020
Resolution: Vessel installed new emergency light.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 February 2020
Resolved
Remove CO2 portable fire extinguisher from bow hold and replace with a Type B or mount outside space.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2020
Resolution: Verified CO2 portable fire extinguisher was removed from bow hold and mounted on starboard outer deck.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 6 February 2020
Resolved
Install flame screens on port fuel vent.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2020
Resolution: Verified installation of flame screens.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 6 February 2020
Resolved
Label general alarm bells and post warning signs in ladder well and galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2020
Resolution: Verified general alarms labeled.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 February 2020
Resolved
Remove permanently installed extension cord in space under pilothouse. All electrical runs must go into junction box or other enclosure.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2020
Resolution: Verified extension cord was removed from space; new wires routed to junction box.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 February 2020
Resolved
Replace expired items in all First Aid kits on board vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2020
Resolution: Verified first aid kit expired items removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 February 2020
Resolved
Replace all gaskets on watertight doors.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 May 2020
Resolution: Verified all gaskets were replaced on all doors.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 February 2020
Resolved
Mark watertight doors and emergency escape exits as required in 46 CFR 144.160
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 May 2020
Resolution: Verified all doors marked properly.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 6 February 2020
Resolved
Provide transfer procedures in accordance with 33 CFR 155.750.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2020
Resolution: MI reviewed transfer procedures; all sat.