Records from 1990 to 2025. Most recent: inspection, 4 August 2025.
Inspection history · 77
4 August 2025
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8202078
8 November 2023
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7822364
12 April 2023
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7667850
21 April 2022
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7435658
13 April 2022
TPO Audit
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7439022
29 November 2021
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7358789
28 March 2021
Type not recorded
No type recorded · Station Sabine · USCG Heartland District (CGD-H) · Activity 7167365
10 September 2020
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7057783
4 May 2020
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6951460
7 April 2020
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6936459
13 March 2020
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6927564
7 October 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5008443
6 September 2014
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4981952
20 May 2014
Industry Initiated Exam · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4863474
12 May 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4856762
27 September 2013
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4768402
13 August 2013
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4684713
3 June 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4339415
27 April 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4299332
25 January 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4232939
20 December 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4211486
19 December 2011
Marine Casualty Follow Up
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4212582
26 October 2011
Industry Initiated Exam · MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4176967
29 August 2011
Marine Casualty Follow Up
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4130131
28 August 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4129338
1 August 2009
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3570875
23 May 2009
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3489655
5 May 2009
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3489417
23 January 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3399174
5 July 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3277817
24 June 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3255706
7 June 2008
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3231655
14 August 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3040338
5 June 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2952432
29 May 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2970399
8 May 2007
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2925854
12 March 2007
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2888436
8 February 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2872748
3 July 2006
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2699726
29 June 2006
Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2694956
23 June 2006
Damage Survey · MTSA Verification
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2691786
22 June 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2690877
14 February 2006
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2586198
30 November 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2647422
29 September 2005
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2513740
16 August 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2471931
6 April 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2405262
21 March 2005
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2315355
9 March 2005
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2307202
7 March 2005
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2307179
7 March 2005
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2315439
1 March 2005
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2301394
25 February 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2302313
11 February 2005
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2323959
10 January 2005
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2273379
14 December 2004
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2269550
23 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1984609
17 October 2002
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1691619
17 October 2002
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1691696
15 September 2000
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 727467
10 August 2000
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 281365
9 August 2000
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 76724
17 March 1999
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 130834
12 June 1997
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 181462
8 February 1997
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 77235
21 December 1995
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 10889
17 October 1995
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 172252
17 October 1995
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 183936
8 June 1995
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 179069
8 May 1995
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 9946
24 March 1995
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 14844
27 December 1994
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 34458
5 November 1994
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 152541
12 June 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 95684
3 May 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 97391
6 September 1991
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 177232
27 November 1990
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 68385
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 August 2025
Resolved
Fuel shutoff requirements. The valve must be operable
from a safe place outside the space where the valve is installed.(e) Each remote valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the
the way to operate it. The valve must be installed in the fuel piping directly outside of the fuel oil supply
tank. The remote fuel shutoff was mis-labeled as the
halon remote valve. The fuel shutoff remote at the main
needs to be replaced. Re-label and prove proper
operation.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2025
Resolution: The deficiency was cleared to the satisfaction of an attending marine inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 August 2025
Resolved
Fixed fire fighting systems. The installed halon fire
suppression system remote valves were mis-labeled as
the emergency fuel shutoffs. Re-Label the halon remotes
with proper name.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 September 2025
Resolution: The deficiency was cleared to the satisfaction to the attending CG Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 20 August 2025
Resolved
An existing vessel may be deemed by the OCMI, or TPO, to be in compliance with this subpart provided.
The vessel has been both in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by either the OCMI, or TPO engaged to perform an audit or survey. The bow tow knees and forward stairway railings have
severe corrosion. Provide a plan and make permanent
repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 September 2025
Resolution: The deficiency was cleared to the satisfaction of an attending marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 August 2025
Resolved
A nozzle made of corrosion-resistant material capable of
providing a solid stream and a spray pattern. The
installed fire hose nozzle did not have capability of
providing a spray pattern. Replace with proper nozzle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 September 2025
Resolution: The deficiency was cleared to the satisfaction of an attending marine inspector.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 August 2025
Resolved
Bilge alarms must be both visual and audible at each
operating station. The bilge alarm at the pilothouse
did not have an audible alarm. Prove the bilge alarm
has an audible means.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 September 2025
Resolution: The deficiency was cleared to the satisfaction of an attending marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 August 2025
Resolved
Machinery and electrical systems must be designed and
maintained to provide for safe operation of the towing
vessel and safety of persons onboard under normal and
emergency conditions. The starboard main engine coolant
expansion tank had a severe leak at the base. Make proper repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 September 2025
Resolution: The deficiency was cleared to the satisfaction of an attending marine inspector.
Construction/Loadline › Hull › Bottom Plating
Issued 23 June 2006
Resolved
Make temp repairs, proceed to shipyard for perm repairs, and repairs will be made to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 23 July 2006
Resolved 29 June 2006
Resolution: Witnessed satisfactory repairs to hull insert and fire pump.
Lifesaving
Issued 10 August 2000
Resolved
Lifepreservers were not readily accessible to ships crew. Discrepancies_x001C_ were corrected on spot.
Condition: Unknown
Due 10 August 2000
Resolved 22 August 2000
Deck/Cargo
Issued 10 August 2000
Resolved
COPT, machinery guards not in place.
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Documentation › Markings/Placards › Oil Discharge Placard
Issued 10 August 2000
Resolved
Oil discharge placards were not onboard.
Condition: Unknown
Due 15 August 2000
Resolved 29 August 2011
Resolution: placards posted
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 10 August 2000
Resolved
46 C.F.R. 4.05-1 & 5 Company failed to immediately notify Marine Safety Office Paducah upon unintentionally grounding the vessel at mile 2 on the Tennessee River. The Coast Guard received initial notification approximately 8 hours and 15 minutes after the event.
Condition: Unknown
Due 10 August 2000
Resolved 29 August 2011
Resolution: Vessel given instuction on proper notification procedures
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 10 August 2000
Resolved
Oil Transfer procedures were not onboard.
Condition: Unknown
Due 15 August 2000
Resolved 29 August 2011
Resolution: oil procedures on board