Documentation record
Registered dimensions (L × B × D)61.5 ft × 26.0 ft × 9.2 ft
Registered tonnagegross 157 / net 106
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSHERMAN SHIPYARD INC · PANAMA CITY, FL, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPITTSBURGH, PA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 27 September 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it157 - Regulatory (Subpart C or D), Gross Ton
106 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 48
1 May 2025
Administrative Inspection · Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8108271
3 January 2023
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7615872
26 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7189348
6 November 2020
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7090977
7 June 2020
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7006896
5 March 2020
Initial Certification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6922852
27 February 2020
TPO Audit · Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6917445
22 February 2019
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6654875
28 December 2014
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 5045036
10 July 2013
MTSA Verification · Industry Initiated Exam · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4649283
31 May 2012
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4330838
16 June 2010
Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3768670
11 March 2009
MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3431746
6 January 2009
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3389834
5 January 2009
Administration
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3389084
5 January 2009
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3389829
15 November 2008
Administration
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3363487
14 March 2007
Administrative Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2887849
22 February 2007
MTSA Verification · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2875765
30 March 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2627150
23 July 2005
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2657620
19 March 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2332362
14 March 2005
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2309938
10 January 2005
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2273379
23 June 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2107917
24 November 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1953968
3 November 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1955588
10 July 2002
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1648241
6 February 2002
Uninspected Towing Vessel
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1484331
2 June 2001
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 33670
14 January 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 770580
12 January 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 208143
27 September 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 147482
20 August 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 758545
17 August 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 201018
13 August 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 185180
19 July 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 431973
20 April 1999
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 13072
31 December 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 684936
12 December 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 423636
25 October 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 421958
28 January 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 412310
2 May 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 96435
18 March 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 401667
3 June 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 760490
28 May 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 203450
28 November 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 372942
7 September 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 490728
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 May 2025
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: high bilge levels, be visible and audible at each operating station. The high bilge alarm was not audible or visible from the pilothouse,or locally in the engine room, instead when the alarm was triggered the alarm panel indicated a low hydraulic fluid alarm. Repair the alarm and provide OCMI with tech report as evidence that the system is restored. This may be done directly or through the TPO.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 14 August 2025
Resolution: Vessel operator provided video evidence of the proper operation of the bilge alarm (audible and visual) directly to the Coast Guard.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 6 February 2002
Resolved
Fire detection control panel is missing a circuit fault detector swtch.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 February 2002
Resolved 6 February 2002
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 6 February 2002
Resolved
Fire detection control panel is missing labeling that indicates location/origin of fire.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 February 2002
Resolved 6 February 2002
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 6 February 2002
Resolved
Fire detection control panel was not certified by a Registered Professional Engineer.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 February 2002
Resolved 6 February 2002
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 6 February 2002
Resolved
Fire detection control panel was not detecting an engine room fire when tested.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 February 2002
Resolved 6 February 2002
Communications › Alarms/Indicators › General Alarm
Issued 6 February 2002
Resolved
General alarm is not being tested weekly and logged.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 February 2002
Resolved 6 February 2002
Communications › Alarms/Indicators › General Alarm
Issued 6 February 2002
Resolved
General alarms red stobe light was lacking labeling.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 February 2002
Resolved 6 February 2002
Engineering
Issued 19 July 1999
Resolved
VESSEL MISSING FLAME SCREES IN ALL FUEL AND SLOP OIL TANK VENTS.
Condition: Unknown
Due 20 August 1999
Resolved 20 August 1999
Documentation
Issued 12 December 1998
Resolved
VESSEL DID NOT HAVE CURRENT DOCUMENTATION OF PERSONNEL DESIGNATED TO BE A "PERSON IN CHARGE" OF OIL TRANSFERS.
Condition: Unknown
Due 11 January 1999
Resolved 25 October 2002
Resolution: Cleared for administrative reasons.
Navigation
Issued 25 October 1998
Resolved
MISSING DISCHARGE PLACARD
Condition: Unknown
Due 24 November 1998
Resolved 25 October 2002
Resolution: Cleared for administrative reasons.
Navigation
Issued 25 October 1998
Resolved
RFORWARD MAST LIGHT BLOWN, NOT WORKING.
Condition: Unknown
Due 25 October 1998
Resolved 25 October 2002
Resolution: Cleared for administrative reasons.