Records from 1995 to 2026. Most recent: inspection, 12 August 2026.
Documentation record
Registered dimensions (L × B × D)52.5 ft × 22.0 ft × 7.7 ft
Registered tonnagegross 87 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNATIONAL SHIPBUILDING CO · BOURG, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it87 - Regulatory (Subpart C or D), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
12 August 2026
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8461930
4 September 2025
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8230249
6 June 2024
COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7923930
14 May 2024
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7912756
23 August 2023
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7775122
8 August 2022
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7531598
17 June 2021
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7228460
7 November 2020
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7106389
13 August 2020
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7032262
9 January 2020
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6886578
28 June 2019
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6886558
12 April 2019
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6661462
12 March 2018
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6394787
14 February 2018
Administration · Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6355914
27 April 2016
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5863832
4 March 2015
Industry Initiated Exam · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5081435
10 December 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5041999
14 June 2012
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4345061
4 June 2012
Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4334605
27 April 2006
Uninspected Other · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2634989
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1998542
19 October 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 102991
20 October 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 697636
22 August 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214071
8 August 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214699
17 May 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 85613
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 17 August 2022
Resolved
The remote fuel shutoff valve must be installed in the fuel piping directly outside the fuel oil supply tank. The vessel's remote fuel shutoff is currently at the day tank, approximately 5' from the valves at the port & starboard tank. At the next drydock, the vessel shall have the remote fuel shutoff valves installed at each fuel tank pipe directly outside the fuel tanks. 46CFR143.260(c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 June 2024
Resolved 6 June 2024
Resolution: Confirmed vessel relocated fuel shutoff valves during this inspection.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 August 2022
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: all bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. The vessel had an accumulation of excessive oily mixture in the engine room bilge. The vessel shall remove the oily mixture within 14 days of this inspection. 46CFR142.220(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2022
Resolved 17 August 2022
Resolution: Vessel provided objective evidence in the form of photos to document the removal of the excessive oily mixture in the engine room bilge.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 August 2020
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Vessels engine room bilge had an accumulation of oil. Vessel shall remove all accumulated oil from bilge space. 46CFR142.220(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 August 2020
Resolution: Vessel removed all accumulated oil from bilge.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 August 2020
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Vessels dryer, which is in the engine room, was being ventilated into the space. Vessel shall either vent to the exterior or develop a method to prevent the lint from exhausting throughout the space.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 August 2020
Resolution: Vessel constructed a ventilation box to capture lint from dryer exhaust.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 June 2019
Resolved
A TOWING VESSEL MUST CARRY ADEQUATE AND UP-TO-DATE CHARTS FOR THE INTENDED VOYAGE. THE CHARTS WERE NOT UP TO DATE. PROVIDE THE MOST RECENT AND CORRECTED CHARTS FOR THE INTENDED VOYAGE.
46 CFR 140.705
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2019
Resolution: Corrected by submitting photos which showed charts were current and corrected for area of operation.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 June 2019
Resolved
EACH TOWING VESSEL MUST BE EQUIPPED WITH A FIRE AXE. THE FIRE AXE WAS FOUND TO BE IN POOR CONDITION. REPLACE FIRE AXE.
46 CFR 142.227
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 June 2019
Resolution: Corrected by submitting photo which showed fire axe was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 June 2019
Resolved
A FIRE PUMP MUST BE CAPABLE OF DELIVERING WATER AT A PITOT-TUBE PRESSURE OF AT LEAST 50 PSI. FIRE PUMP DID NOT MEET PRESSURE REQUIREMENTS. 46 CFR 142.325(a)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 June 2019
Resolution: Corrected by submitting video which showed fire pump operating with at least 50 psi.