Records from 1992 to 2025. Most recent: inspection, 23 December 2025.
Documentation record
Registered dimensions (L × B × D)55.8 ft × 24.1 ft × 9.2 ft
Registered tonnagegross 129 / net 87
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLOUIS G ORTIS BOAT CO, IN · KROTZ SPRINGS, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portJEFFERSONVILLE, IN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 February 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it129 - Regulatory (Subpart C or D), Gross Ton
87 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 51
23 December 2025
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8286871
19 September 2025
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8231606
2 April 2025
TPO Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8102434
11 December 2024
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8046261
11 December 2024
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8048185
21 August 2023
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7774419
20 August 2023
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7773331
26 June 2020
Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6990311
15 March 2020
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6928098
9 August 2017
Industry Initiated Exam · Administration
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6240729
5 August 2014
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4980697
4 February 2011
Industry Initiated Exam
Physical examination · Towing Vessel National Center of Expertise · Activity 3941719
18 October 2006
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2802975
19 September 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2784733
15 September 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2778971
31 July 2006
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2734957
29 July 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2444241
24 June 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2410176
11 April 2005
Administrative Inspection
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2331223
23 March 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2317479
18 October 2004
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2223428
9 March 2004
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2021875
23 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1984576
15 August 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1877277
18 May 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1803052
3 September 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1670068
15 April 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1613213
1 April 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1599805
26 May 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 167810
19 May 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 186104
10 January 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 18867
15 July 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 44592
4 July 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 68244
4 July 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 81387
29 March 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 26278
2 March 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 657235
28 January 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 137459
28 January 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 212491
31 July 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 431622
12 January 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 63757
12 January 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 217934
25 March 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 109512
11 February 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 412758
11 December 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 708555
14 November 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 191493
26 February 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 137533
15 October 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 96978
21 July 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 150423
4 November 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 68230
3 March 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 365103
6 February 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 72441
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 December 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Generators are not producing enough voltage to properly operate the necessary systems such as steering.
***In lieu of Coast Guard attendance, the Third Party Organization, ABS, may accept/approve the repairs and provide a report to the Coast Guard inspector listed below***
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 December 2024
Resolution: replaced voltage regulator
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 August 2023
Resolved
Propulsion Machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment must be maintained to ensure proper operation and be suitable for route and service. STBD engine inop due to log jammed in prop. Replace/Repair IAW company TSMS. Objective evidence attesting to root cause & satisfactory repairs must be submitted to TPO. TPO advise local OCMI once complete.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 August 2023
Resolution: Received objective evidence of root cause and satisfactory repairs from TPO. OE loaded into def docs. Vessel cleared to return to service.
Electrical › Electric Supply System (service) › Cable
Issued 31 July 1999
Resolved
REMOVE DEAD END WIRE FROM FORWARD BULKHEAD ENGINE ROOM.
Condition: Unknown
Due 30 August 1999
Resolved 4 February 2011
Resolution: Observed that the engine room had been rewired. Dead end wire was removed.
Construction/Loadline
Issued 31 July 1999
Resolved
REMOVE OIL FROM ENGINE ROOM BILGE PRIOR TO DEPARTURE.
Condition: Unknown
Due 31 July 1999
Resolved 11 August 1999
Electrical
Issued 31 July 1999
Resolved
REMOUNT ELECTRICAL FUSE BOX AFT PORT ENGINE ROOM BULKHEAD PRIOR TO DEPARTURE.
Condition: Unknown
Due 31 July 1999
Resolved 11 August 1999
Engineering
Issued 31 July 1999
Resolved
REDUCE THE RATE OF LEAK THROUGH SHAFT PACKING PRIOR TO DEPARTURE.
Condition: Unknown
Due 31 July 1999
Resolved 11 August 1999