Records from 1999 to 2026. Most recent: inspection, 15 June 2026.
Documentation record
Registered dimensions (L × B × D)56.5 ft × 22.1 ft × 8.4 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHENRY'S BOAT BUILDERS · MORGAN CITY, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portOLD SAYBROOK, CT
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 April 2026 · expires 30 April 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
15 June 2026
Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8391107
27 May 2026
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8382141
11 December 2025
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8282126
1 August 2025
TPO Audit
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8202593
8 May 2025
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8133411
7 April 2025
Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8106211
20 February 2025
Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8082146
6 March 2022
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7406551
5 March 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7416768
6 April 2020
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6936028
20 November 2019
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6859076
30 October 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6845625
22 October 2019
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6839954
22 October 2019
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6844058
16 October 2019
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6835401
16 August 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6785351
15 August 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6797162
30 July 2019
Administrative Inspection · COI Inspection · Initial Certification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6767828
11 August 2018
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6510479
26 June 2018
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6456579
8 September 2017
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6262774
3 November 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5017366
2 August 2011
DAPI Audit · Industry Initiated Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4103288
23 March 2011
DAPI Audit · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3969345
11 August 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 666024
11 June 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 196931
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 June 2026
Resolved
A towing vessel must carry adequate and up-to-date charts, maps and nautical publications for the intended voyage. Vessel missing chart/map, Coast Pilot and light list for area of operation. Provide missing items on board the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2026
Resolved 13 July 2026
Resolution: completed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 June 2026
Resolved
Provide valid FCC Bridge to Bridge Certificate. 47 CFR 80
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2026
Resolved 13 July 2026
Resolution: rec'd copy, updated MISLE
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 June 2026
Resolved
Vessel required 3 day and 3 night flares. Vessel had at least 3 day flares (orange smoke), but the night flares (hand red) were expired. Provide 3 night flares, for a total of 3 day and 3 night (they may be hand red flares).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2026
Resolved 21 July 2026
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 June 2026
Resolved
At least 2 lifebuoys on a towing vessel over 26' must be fitted with a floating electric waterlight. One waterlight did not work. Prove proper operation of both floating electric waterlights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2026
Resolved 13 July 2026
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 June 2026
Resolved
Each ring lifebuoy must be marked in block capital letters with vessel name. Lifebuoys were marked with old vessel name. Mark buoys with current vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2026
Resolved 13 July 2026
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 15 June 2026
Resolved
Each lifejacket (PFD) must be marked in block capital letters with the vessel name. All PFD's were marked with old vessel name. [name withheld] with new vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2026
Resolved 13 July 2026
Resolution: completed
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 15 June 2026
Resolved
The supplemental flashing red light for the general alarm in the E/R (b/t the generators) has come loose from its fitting. Repair light/fitting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2026
Resolved 13 July 2026
Resolution: completed
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 15 June 2026
Resolved
Master must ensure that drills are conducted and instructions given to ensure all crewmembers are capable of performing the duties expected of them during emergencies. Conduct and log man overboard drill.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2026
Resolved 21 July 2026
Resolution: completed
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 15 June 2026
Resolved
Drug & Alcohol Program information: Post Employee Assistance Program information, and Substance Abuse Professional number (on board in a conspicous place for crewmembers to access).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2026
Resolved 13 July 2026
Resolution: completed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 May 2026
Resolved
A towing vessel may not be operated without having onboard a valid COI issued by the Coast Guard. Vessel COI was deactivated on Dec 11, 2025, when there was a change in Owner/Operator. Vessel must complete a new COI inspection prior to operation as a towing vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2026
Resolution: Completed COI inspection.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 8 May 2025
Resolved
The following vessels must have on board a properly installed, operational Coast Guard type-approved AIS Class A device: A towing vessel of 26 feet or more in length and more than 600 horsepower, engaged in commercial service.
Vessel was identified by USCG Vessel Traffic Services as not having a fully functioning AIS. Vessel is to enact repairs with proof to the CG prior to leaving port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2025
Resolution: Technician report received. All sat.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 March 2022
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel experienced a loss steering while underway in the Houston ship channel. Prior to movement, submit report from TPO attesting to satisfactory repair
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 March 2022
Resolution: Report received from TVIB attesting for repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 October 2019
Resolved
Vessels port main engine overheated and is not operating as designed. Directed vessel to make appropriate repairs.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 October 2019
Resolved 24 October 2019
Resolution: Vessel made appropriate repairs to port main engine via technicians report. Report was made to the satisfaction of attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 September 2019
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Exposed electrical cables and wiring were identified in engine room near the emergency beacon.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2019
Resolved 3 October 2019
Resolution: Cleared by TPO.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 September 2019
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
The electrical panel in the galley passageway had exposed wiring (missing blank)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2019
Resolved 3 October 2019
Resolution: Cleared by TPO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 September 2019
Resolved
Piping and machinery components that exceed 220 °C (428
°F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated.
Turbo Exhaust manifold piping on both Main Diesel
Engines near elbow not insulated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2019
Resolved 3 October 2019
Resolution: Cleared by TPO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 September 2019
Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail.
Air compressor belt guard not properly secured fastened.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2019
Resolved 3 October 2019
Resolution: Cleared by TPO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 September 2019
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly.
The air condition package piping bulkhead penetrations are open to the weather.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2019
Resolved 3 October 2019
Resolution: Cleared by TPO.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 September 2019
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following:
Storage areas are kept free from accumulation of combustible and flammable materials insofar as practicable.
The dryer in the engine room is missing a lint hose/trap and blowing directly into the space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2019
Resolved 3 October 2019
Resolution: Cleared by TPO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 August 2019
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of perons onboard under normal and emergency conditions. During dive operations pieces of melted rubber were observed surrounding the starboard shaft. Provide proof that all cutlass bearings and associated equipment are fully operational.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 August 2019
Resolved 16 August 2019
Resolution: Recieved photos from the TPO of the repaired cutlass bearing.