Records from 1997 to 2025. Most recent: inspection, 4 September 2025.
Documentation record
Registered dimensions (L × B × D)52.0 ft × 22.0 ft × 7.7 ft
Registered tonnagegross 59 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHEBERT IRON WORKS INC · LAROSE, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it47 - Simplified, Net Ton
59 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 25
4 September 2025
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8218905
25 August 2025
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8217630
16 September 2024
Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 8003819
7 August 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7976404
16 June 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7739979
11 May 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7449511
6 May 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7590969
23 April 2021
Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7181475
1 August 2015
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 5206119
5 August 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4991675
22 March 2012
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4277982
10 September 2011
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 4146336
25 April 2011
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3996161
25 April 2011
Spot Check (Safety) · Damage Survey · Administration · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3996203
21 January 2011
Deficiency Check · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3934066
17 December 2010
Industry Initiated Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3912738
6 February 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3682685
14 November 2008
Administration
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3362976
12 October 2006
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2799732
22 February 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2589884
4 March 2004
Type not recorded
No type recorded · USCG Heartland District (dre) · USCG Heartland District (CGD-H) · Activity 2018220
9 October 2003
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1927980
30 September 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 29572
21 April 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 24568
12 August 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 406843
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 August 2025
Resolved
Vessel overdue for annual inspection, vsl must complete annual or renewal inspection prior to returning to service.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 August 2025
Resolved 13 November 2025
Resolution: Vessel's annual inspection was conducted, but never documented in MISLE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 11 May 2022
Resolved
Equipped with gauges at the machinery location; auxiliary generator engine RPM. Port generator did not have an RPM in the engine room.
46 CFR 143.230(c)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2022
Resolved 11 May 2022
Resolution: Demonstrated evidence of new RPM installed on the port generator.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 11 May 2021
Resolved
urvival craft must be stowed in accordance with the requirements of §199.130 of this chapter, as far as is practicable on existing towing vessels. Survival craft must be float free, painter must be attached to vessel by float free link or hydrostatic release.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 May 2021
Resolved 12 May 2021
Resolution: Installed weaklink
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 April 2021
Resolved
Lifebuoys must be approved under approval series 160.050 24in lifebuoys must not exceed 5lbs, Lifebuoy plug had fallen out and ring had become saturated with water.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 May 2021
Resolved 12 May 2021
Resolution: Replaced Lifebuoy
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 April 2021
Resolved
Each lifejacket must be marked In block capital letters with the name of the vessel. Lifejackets marking was easily removable.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 May 2021
Resolved 12 May 2021
Resolution: Permenantly marked PFD's
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 23 April 2021
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Weather tight doors had gaskets doubled up and were sealing improperly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2021
Resolved 16 June 2021
Resolution: Replaced gaskets and welded new striker for dogs.
Documentation › Certificates/Documents › FCC SSL
Issued 12 August 1997
Resolved
Vessel did not have ship radio licsence.
Condition: Unknown
Due 12 September 1997
Resolved 26 October 2006
Lifesaving
Issued 12 August 1997
Resolved
Vessel had four persons on board and only two serviceable PFD's._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Navigation › Collision/Grounding Avoidance › Relative Motion Plotting Equipment
Issued 12 August 1997
Resolved
Vessel did not have any current or currently corrected charts and did not have local notice to mariners on board.
Condition: Unknown
Due 12 September 1997
Resolved 26 October 2006
Navigation › Piloting/Steering › Marine Charts
Issued 12 August 1997
Resolved
Vessel was not making required tests and log entries._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 September 1997
Resolved 26 October 2006