Records from 1984 to 2002. Most recent: inspection, 2 December 2002.
Inspection history · 19
2 December 2002
Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1713268
26 November 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1711416
26 November 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1715050
20 August 2002
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1663360
8 May 2002
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1614476
11 February 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1486718
5 November 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 434495
30 September 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 29572
10 February 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 424142
2 October 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 408220
4 October 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 383422
13 July 1993
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 359429
23 June 1989
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 330910
10 April 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 322585
29 July 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 445315
12 January 1987
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 520082
29 December 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 313507
19 July 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 303237
16 July 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 296998
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 2 December 2002
Resolved
Main Engine No.3 fuel injector is malfunctioning.
Action required: 705 - Other - as specified
Due 3 December 2002
Resolved 4 December 2002
Resolution: Received class report, cleared deficiency.
Electrical
Issued 20 August 2002
Resolved
Vessel possessed numerous electrical hazards. Please review details listed in special notes. (items a - r). Not IAW SOLAS 60/II/27.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2002
Resolved 23 August 2002
Resolution: Master faxed a letter to ActNY indicating that all repairs were completed.
Fire Fighting › Miscellaneous Items
Issued 20 August 2002
Resolved
Numerous open and closed paint containers improperly stowed outside of designated paint locker behind port side lube oil service tank and forecastle upper deck.SOLAS 60/II/49(a) and MSC/Circ.601 LEGACY COMPONENT DESC: Paint/Flammable Liquid Lockers
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2002
Resolved 23 August 2002
Resolution: Master faxed a letter to this office indicating that corrections have been completed.
Accommodation/Occupational Safety › Occupational Safety
Issued 20 August 2002
Resolved
Ladder railings in E/R between MDE head deck and Ship svc generator deck and stbd side of MDE aft of OWS are cut and loose. ICLL 1966 article 14.
Correct immediately concluding ship's service generator repair/installation. LEGACY COMPONENT DESC: Hand Grab
Condition: Placed in Improper Service
Due 1 September 2002
Resolved 23 August 2002
Resolution: Master faxed a letter to this office indicating that corrections have been completed.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers
Issued 20 August 2002
Resolved
Semi portable fire extiguisher located near #3 Paxman generator possesses severely heat stressed and cracked dishcharge hose. Fire extinguisher does not meet the condition of original survey. SOLAS 60/II/65(e). LEGACY COMPONENT DESC: Discharge Hose
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2002
Resolved 23 August 2002
Resolution: Master faxed a letter to this office indicating that corrections have been completed.
Construction/Loadline › Penetrations
Issued 20 August 2002
Resolved
"Junction box" strainer for bilge fire pump leaking. ICLL 1966 Regulation 22. LEGACY COMPONENT DESC: Gasket
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 1 September 2002
Resolved 23 August 2002
Resolution: Master faxed a letter to this office indicating that repairs have been completed.
Engineering › Freshwater System (jacketwater cooling)
Issued 20 August 2002
Resolved
#1 Paxman lube oil heat exchanger leaking. SOLAS I/11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2002
Resolved 23 August 2002
Resolution: Master faxed a letter to this office indicating that repairs have been completed.
Construction/Loadline › Structures
Issued 20 August 2002
Resolved
Deck possessed one approximate 12" x 12" penetration. Penetration was cut to provide clearance for machinery installation. and provides no water intrusion protection in the event of rain. Water intrusion would have free communication to main ship service generator motors. SOLAS I/11. LEGACY COMPONENT DESC: Deck Plating
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 September 2002
Resolved 23 August 2002
Resolution: Master faxed a copy of class report indicating that an approved insert plate has been installed.
Accommodation/Occupational Safety › Occupational Safety
Issued 20 August 2002
Resolved
Oxygen and acetylene bottles in E/R and forecastle are missing bottle caps over valves and are not properly secured. 46 CFR 147.60. LEGACY COMPONENT DESC: Welding/Hot Work
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2002
Resolved 23 August 2002
Resolution: Master faxed a letter to this office indicating that corrections have been completed.
Construction/Loadline › Hull
Issued 20 August 2002
Resolved
Located in lower deck of forecastle, doublers are installed on vessel's skin between frame #6 and #7 port and starboard sides below hawse pipes. Port hawse pipe possesses doubler and starboard hawse pipe possesses wastage and presents rust streaks indicating communication with exterior. ICLL 1966 LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 August 2002
Resolved 23 August 2002
Resolution: Master faxed a copy of class report indicating that these repairs are now an active condition of class.
Lifesaving › Lifebuoys
Issued 20 August 2002
Resolved
Numerous lifebuoys possesses worn and ineffective retro-reflective tape. LSA Code LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2002
Resolved 23 August 2002
Resolution: Master faxed a letter to this office indicating that corrections have been completed.
Documentation › Certificates/Documents
Issued 20 August 2002
Resolved
IOPP Certificate was missing oil content meter throughput information. Previous (expired) certificate revealled 2.5 cubic meters/hr disharge rate. This was verified by the equipment's original operator's manual. Have class address issue and make corrections to certrificate as necessary. LEGACY COMPONENT DESC: IOPP Certificate
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 August 2002
Resolved 23 August 2002
Resolution: Master faxed a copy of class report indicating that corrections have been made to certifiicate.
Engineering › Generator (propulsion-electric)
Issued 20 August 2002
Resolved
Vessel's #3 Paxman service generator (SG) was missing from space. #2 Catepillar SG was dissassembled and not working. A Cat.SG was mounted outside on stbd side 2nd deck aft near stack and has been approved for use by class in lieu of the #3 Provide ActNY with class report upon repair completion.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 August 2002
Resolved 23 August 2002
Resolution: Outstanding condition of class remains active.
Lifesaving › Lifebuoys
Issued 8 May 2002
Resolved
Make adjustments to floatlight holder throughout the ship to ensure proper release; Provide lines made of approved material to floatlight attachments. IAW SOLAS 74 Ch. III/ Reg. 2.1.1.7 LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Due 8 June 2002
Resolved 20 August 2002
Resolution: Corrected to the satisfaction of attending USCG MI''s.
Pollution Prevention/Response › Prevention Equipment
Issued 8 May 2002
Resolved
Make repairs to leaking saltwater supply line to sewage treatment plant. IAW SOLAS 74 Ch II-1 LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Improper/Lack of Maintenance
Due 8 June 2002
Resolved 20 August 2002
Resolution: Corrected to the satisfaction of attending USCG MI''s.
Lifesaving
Issued 10 February 1999
Resolved
INSTALL WEAK LINK ON PORT AND STARBOARD LIFE RAFES. _x001C_ _x001C_ SOLAS 74 A REG III/29
Condition: Unknown
Due 10 February 1999
Resolved 18 February 1999
Deck/Cargo
Issued 10 February 1999
Resolved
PROVE PROPER OPERATION OF PORT DAVIT BRAKE._x001C_ _x001C_ SOLAS 74 A REG III/19.2
Condition: Unknown
Due 18 February 1999
Resolved 18 February 1999
Fire Fighting
Issued 10 February 1999
Resolved
REPLACE FACE MASK OF SCBA AND ENSURE PROPER OPERATION OF SCBA._x001C_ _x001C_ SOLAS 74 A REG II 2/21
Condition: Unknown
Due 18 February 1999
Resolved 18 February 1999
Documentation
Issued 10 February 1999
Resolved
VESSEL NOT MANNED IAW SAFE MANNING DOCUMENT. SOLAS 74 A REG V/13
Condition: Unknown
Due 18 February 1999
Resolved 18 February 1999
Fire Fighting
Issued 4 October 1995
Resolved
PRIOR TO NEXT U.S. PORT, REPAIR EXHAUST LEAK ON EMERGENY GEANERATOR.
Condition: Unknown
Due 5 November 1999
Resolved 5 November 1999
Fire Fighting
Issued 4 October 1995
Resolved
CORRECT FIRE CONTROL PLAN TO INDICATE EXACT LOCATION OF INTER SHORE CONNECTION.
Condition: Unknown
Due 5 October 1995
Resolved 5 October 1995
Fire Fighting
Issued 4 October 1995
Resolved
PRIOR TO DEPARTING PORT OF TAMPA, DEMONSTRATE PROPER OPERATION OF EMERGENCYFIRE PUMP.
Condition: Unknown
Due 5 October 1995
Resolved 5 October 1995
Navigation
Issued 10 April 1988
Resolved
BRITISH ADMIRALTY COAST PILOT VOLUME 8, 1975ED., FOREIGN EQUIVALENT TO U.S.COAST PILOT VOLUME 7, ONBOARD BUT NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33(A). MISSING WAS SUPPLEMENT 8. NO OTHER FOREIGN OR U.S. EQUIVALENTS ONBOARD.
Condition: Unknown
Due 12 April 1988
Resolved 10 April 1988
Navigation
Issued 19 July 1985
Resolved
33 CFR 164.33(A)(2)(I): U.S. COAST PILOT WAS NOT CURRENT OR CORRECTED. THE MASTER STATED THAT THEY DID NOT CORRECT THE COAST PILOT.
Condition: Unknown
Due 30 January 1987
Resolved 19 July 1985
Documentation
Issued 16 July 1984
Resolved
PROVIDE ONBOARD VESSEL OIL POLLUTION PLACARD AS REQUIRED BY 33 CFR 155.440
Condition: Unknown
Due 29 December 1986
Resolved 16 July 1984
Navigation
Issued 16 July 1984
Resolved
PROVIDE ONBOARD VESSEL CHART #11341 AS REQUIRED BY 33 CFR 164.33
Condition: Unknown
Due 29 December 1986
Resolved 16 July 1984