Documentation record
Registered dimensions (L × B × D)103.7 ft × 34.0 ft × 9.5 ft
Registered tonnagegross 394 / net 255
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJANOUSH MARINE, INC. · ROSEDALE, MS, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMOBILE, AL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 22 July 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it394 - Regulatory (Subpart C or D), Gross Ton
255 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 46
7 September 2023
Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7773987
19 July 2022
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7510806
28 March 2021
Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7164016
28 March 2021
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7169142
5 November 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7090568
5 November 2020
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7092285
19 September 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7063827
6 May 2020
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6950000
22 April 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6942399
20 December 2019
Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6877375
20 December 2019
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6880001
16 June 2019
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6733140
22 April 2019
Administrative Inspection · Initial Certification · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6667983
6 November 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6575336
5 November 2018
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6575580
21 February 2016
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5820933
17 November 2015
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5766134
6 August 2015
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5207872
17 June 2015
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5156544
19 March 2015
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5087649
11 November 2014
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5026681
20 August 2014
MTSA Verification · Industry Initiated Exam · MARPOL
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4960656
3 July 2014
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5008539
25 June 2012
Deficiency Check · Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4351367
12 June 2012
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4341793
12 June 2012
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4341795
9 June 2012
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4338491
2 June 2012
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4349006
1 December 2011
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4225921
5 August 2011
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4137259
16 October 2010
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3874289
24 February 2009
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3571639
11 February 2009
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3416965
18 November 2008
Administration
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3365192
17 October 2006
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2802582
13 February 2006
MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2609108
24 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1990856
19 July 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 114927
25 April 1996
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 26284
25 April 1996
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 216919
16 September 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 168950
15 August 1995
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 381724
14 January 1995
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 40483
19 October 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 187207
13 October 1994
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 371417
20 July 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 310449
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 October 2023
Resolved
Unable to test bilge suction due to concern of crew that the associated piping could contain oil and would therefor be pumped overboard creating a pollution incident
46 CFR 137.220
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2023
Resolved 25 October 2023
Resolution: MI was provided objective evidence of the satisfactory operation of the bilge piping system
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 March 2021
Resolved
(C)Propulsion machinery including main engines, reduction gears, shafting, bearings, and electrical and systems, must: (1) Be maintained to ensure proper operation. Vessel lost a proller while transitting the Mobile River.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 November 2020
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board. Vessel reported their port generator is inoperable. Vessel is allowed to proceed directly to Blakely Boatworks to affect repairs and is not permitted to conduct cargo operations until generator is repaired and verified by a class report.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 September 2020
Resolved
Propulsion machinery to include electrical equipment and systems must be maintained to ensure proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2020
Resolved 19 September 2020
Resolution: Submitted tech report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 December 2019
Resolved
Vessel suffered steering casualty rendering one main rudder inoperable vessel is permitted to transit with current load of six barges down bound to Mobile. Immediately after dropping barges vessel is to proceed to Blakley boat works to conduct permeant repairs. Vessel is not permitted to conduct additional operations until permanent repairs have been completed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 December 2019
Resolution: Vessel provided satisfactory evidence IAW their TSMS to demonstrate that the deficiency had been rectified by installing a new rudder