Records from 1989 to 2004. Most recent: inspection, 21 January 2004.
Inspection history · 30
21 January 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1989534
4 April 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1655459
8 February 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1608112
11 September 2001
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1072884
1 June 2001
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397647
22 May 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 771843
11 May 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 194710
15 March 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421818
13 April 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453571
25 June 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396947
13 August 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1368351
3 August 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 55258
11 June 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 775470
15 May 1996
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1417954
11 May 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468789
13 June 1994
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405568
10 June 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403639
6 October 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 938237
7 July 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 957795
23 June 1992
Re-Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425269
12 May 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1265956
14 June 1991
Deadweight Survey · Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 913114
15 July 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1216447
23 February 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 933359
20 February 1990
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 915405
24 January 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1233091
9 November 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 908018
9 November 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1035997
29 August 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1036225
15 June 1989
Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1348666
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 4 April 2002
Resolved
Blank off open breakers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2002
Resolution: Openings blanked off.
Stability › Watertight Integrity
Issued 4 April 2002
Resolved
Adjust P & S engine room escape hatches
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2002
Resolution: Hatches adjusted prior to completion of inspection.
Navigation
Issued 15 March 2000
Resolved
RELOCATE STERN NAVIGATION LIGHT AS PER COLREG NAVIGATION RULES (RULE 21 (c)) TO STERN OF VESSEL, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Construction/Loadline
Issued 15 June 1989
Resolved
PROVIDE ANCHOR AND CHAIN/LINE AS REQUIRED.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Deck/Cargo
Issued 15 June 1989
Resolved
PROVIDE TESTS OF PORT AND STARBOARD INSTALLED CRANES.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Lifesaving
Issued 15 June 1989
Resolved
PROVIDE LINE THROWNING GUN AND KIT AS REQUIRED BY 46 CFR 94.45.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Documentation
Issued 15 June 1989
Resolved
PROVIDE STABILITY TEST AND LETTER AS REQUIRED BY 46 CFR SUBCHAPTER "S".
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Documentation
Issued 15 June 1989
Resolved
PROVIDE CURRENT CERTIFICATE OF DOCUMENTATION WITH CORRECTED GROSS AND NET TONNAGE.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Documentation
Issued 15 June 1989
Resolved
PROVIDE APPROVED PLANS AS REQUIRED BY 46 CFR 91.5.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Engineering
Issued 15 June 1989
Resolved
PROVIDE TAILSHAFT EXAM AS REQUIRED BY 46 CFR 61.20-15.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Documentation
Issued 15 June 1989
Resolved
SUBMIT OPERATING MANUAL FOR APPROVAL.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989