Records from 1985 to 2021. Most recent: inspection, 26 February 2021.
Inspection history · 106
26 February 2021
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7143727
14 December 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7108899
17 August 2020
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7030031
19 July 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7009959
24 June 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6985466
1 April 2020
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6933294
19 February 2020
PSC A
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6908369
19 September 2019
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814077
5 September 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6803894
31 May 2019
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6699761
29 May 2019
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6698278
29 May 2019
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6699327
8 March 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6628818
7 January 2019
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6606618
10 November 2018
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6574082
8 November 2018
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6577746
26 September 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6549432
23 August 2018
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6517840
13 August 2018
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6502764
19 July 2018
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6484145
14 July 2018
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6478883
13 July 2018
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6476364
11 July 2018
In-Service Inspection · PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6404321
8 May 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6409523
2 May 2018
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6404337
10 April 2018
ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6378630
29 December 2017
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6327206
16 November 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6291688
2 October 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6279842
15 August 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6234294
5 August 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6237567
2 August 2017
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6228209
19 May 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6149621
19 April 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6124058
15 January 2017
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6069301
6 January 2017
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6067224
15 November 2016
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6041398
31 October 2016
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6032013
20 October 2016
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6010906
12 October 2016
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6021216
27 September 2016
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6010693
26 September 2016
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6009307
16 September 2016
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6002368
5 September 2016
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5992643
29 August 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5986254
17 August 2016
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5975241
20 May 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5882304
12 May 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5868206
18 April 2016
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5856503
13 March 2016
Ballast Water Examination · PII Safety Exam · Deficiency Check · ISPS III Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5826924
5 January 2016
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5793770
4 January 2016
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5790320
27 August 2015
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5225381
29 June 2014
PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4901722
17 June 2014
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4890454
16 May 2012
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4309908
4 February 2012
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4241274
11 December 2011
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4205881
2 August 2011
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4095772
19 July 2011
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4088056
24 January 2011
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3931645
27 September 2010
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3855578
17 March 2010
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3697158
22 April 2009
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3458103
12 March 2009
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3429679
27 August 2008
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3306365
15 February 2008
PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3145545
18 January 2008
ISPS II Exam · Ballast Water Examination · Deficiency Check · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3119780
7 January 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3126061
15 June 2007
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2962413
29 May 2007
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2945393
25 May 2007
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2940006
20 April 2007
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2913904
20 October 2006
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2804480
18 October 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2803520
3 October 2006
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2792932
2 October 2006
Ballast Water Examination · ISPS III Exam · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2791137
21 September 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2783887
21 September 2006
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2787191
19 July 2006
Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2717402
13 July 2005
MARPOL Annex V Examination · Ballast Water Examination · NPV Safety Exam · MARPOL Annex I Examination · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2424051
10 April 2005
NPV Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2330352
4 February 2005
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2286904
13 January 2005
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2274239
13 January 2005
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2274263
19 November 2004
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2244412
19 November 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2244592
26 October 2004
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2228750
30 September 2004
NPV Safety Exam · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2209985
24 June 2004
Random ISPS/MTSA/PSC
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2109340
28 May 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2080734
29 March 2004
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2033302
12 March 2004
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2023251
10 March 2004
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2022144
6 May 2003
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1788325
4 January 2003
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1736597
16 May 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 102108
16 May 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 290360
23 January 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 286100
12 September 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 446007
25 August 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 647794
18 August 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 352631
31 March 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 349844
21 August 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 338891
4 August 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 310629
3 January 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 299677
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 5 September 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO noted the vessel's after fire dampeners on port and stbd sides did not close entirely and were difficult to close due to lack of maintenance. 74SOLAS(14) I/II(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 19 September 2019
Resolution: PSCO verified proper operation of both port and stbd side fire dampers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 May 2019
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO NOTED LINKAGE BETWEEN MOTOR AND CONTROLLABLE PITCH PROPELLER PUMP WAS BROKING.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2019
Resolution: PSCO verified proper repairs and reviewed Class Report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 July 2018
Resolved
1400-After any survey of the ship under regulations 7, 8, 9, and 10 of this chapter has been completed no change shall be made in the structural arrangements machinery, equipment covered by the survey. PSCO noted control pitch propellar not functioning as designed.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 July 2018
Resolved 19 July 2018
Resolution: Recieved class survey report witnessing satisfactory testing and interviewed technician who attested to repairs. Inspected system under pressure. All satisfactory for CPP system. Witnessed starboard engine also satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 July 2018
Resolved
13199-after any survey of the ship, no change shall be made to machinery or equipment. PSCO observed lube oil mist leaking from air compressor serving the ship main engine start air system. 74 SOLAS I/11
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 August 2018
Resolved 23 August 2018
Resolution: Recieved Class Report and PSCO verified proper repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 July 2018
Resolved
07199-after any survey of the ship no change shall be made to the machinery or equipment. PSCO noted multiple fuel oil leaks on the fuel oil purifier backflush filter system. 74 SOLAS I/II.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 July 2018
Resolved 13 July 2018
Resolution: All leaks were rectified by the vessel crew.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 July 2018
Resolved
09219- wiring shall be supported in such a manner as to avoid chafing or other injury. PSCO noted multiple wire passes without suitable material to prevent chafing throughout engine spaces. 47 SOLAS I/27(a)(vi)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 August 2018
Resolved 13 August 2018
Resolution: Wire was correctly supported so it would not chafe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 11 July 2018
Resolved
13106- in spaces where penetration of oil products is possible, the surface of insulation shall be impervious to oil or oil vapors. PSCO noted multiple pipe lagging insulations that were not made impervious to oil or oil vapors. 74 SOLAS(14) II-2/4.4.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 August 2018
Resolved 13 August 2018
Resolution: New lagging was put in.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 29 December 2017
Resolved
1430-main source of electrical power shall consiste of at least two generators sets. One of the two generator sets was reported out of commission due to overheating. 74SOLAS(14) II-1/ 41.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 December 2017
Resolved 30 December 2017
Operations/Management › Pollution › Approved Method for Annex VI Compliance
Issued 2 August 2017
Resolved
MARPOL VI.5.5: An additional survey, either general or partial according to the circumstances shall be made whenever any important repairs or renewals are made as prescribed in paragraph 5 of this regulation or after repairs resulting from investigation prescribed in paragraph 6 of this regulation. PSCO noted that vessel has overflow pipe from HFMGO to LSMGO causing vessel to burn HSMGO in ECA. 17
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2017
Resolved 5 August 2017
Resolution: PSCO reviewed class report and satisfactory completion of fuel piping modifications.
Fire Fighting › Combustible Materials › Insulation
Issued 19 April 2017
Resolved
74SOLAS II-2/33(a): 0820: Arrangements for the distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO noted that througout the engine room lagging and protection for fuel oil lines was missing/damaged.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Witnessed new lagging in place, especially on main engines and boiler systems.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 April 2017
Resolved
74SOLAS II-1/27.a.i.1: 0999: All electrical apparatus shall be so constructed and so installed that danger or injury in ordinary handling shall not exist. PSCO noted that juntion boxes throughout the ship were uncovered and not properly mounted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Witnessed every junction box with installed covers and properly mounted
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 19 April 2017
Resolved
1499: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO noted exhaust leaks on the port Main Diesel Engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Witnessed satisfactory test report survey from class society and replaced exhaust lagging on port engine
Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 20 October 2016
Resolved
1410 74SOLAS(14CONS)1/11 THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESSNET REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA. STARBOARD MAIN ENGINE STILL IN PROCESS OF BEING REPAIRED. START AIR DISTRIBUTION BOX WILL NOT ALLOW START IN ALL POSITIONS. CLASS CURRENTLY ABOARD TO WITNESS TESTING OF REPAIRS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2016
Resolution: Received report of survey from Class Society that starboard engine repairs are completed and engine has been successfully tested and witnessed.
Communications › Alarms/Indicators › General Alarm
Issued 23 March 2016
Resolved
PSCO noted that all audible alarm signals for the engine room were found to be inoperable. 1000 - Communications - Engine room shall be manned with regular patrols carried out and logged in engine room log book until such time defective alarm(s) are rectified. 74SOLAS(14) I/11.a
Action required: 705 - Other - as specified
Due 31 July 2016
Resolved 24 April 2016
Resolution: Vessel installed a new engine room alarm pannel.
Construction/Loadline › Structures › Door
Issued 13 March 2016
Resolved
0910 - Construction - In the case of hydraulic operation, each power source of power-operated sliding doors (Class 3) shall consist of a pump capable of closing all watertight doors in not more than 60 seconds. The ship's #2 power-operated sliding door (Class 3) hydraulic pump was inoperable. 1974 SOLAS II-1/13.i.iii
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 March 2016
Resolution: Vessel crew repaired hydraulic pump to power-sliding door and Class attested to the repair.
Engineering › Fuel Oil Service System › Piping
Issued 13 March 2016
Resolved
0820 - Engineering - In a ship in which oil fuel is used, the arrangement for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. The fuel supply line to the ships emergency generator is actively leaking. 1974 SOLAS II-2/33.a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 March 2016
Resolution: Vessel crew replaced fuel supply line on generator and Class attested to the repair.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 5 January 2016
Resolved
1410-Propulsion Main Engine-Condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship and all respects will remain to proceed to sea without danger to the ship or persons onboard. Ship suffered a catastrophic failure of port main propulsion engine. SOLAS 74(amended)14 I/11a
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 18 April 2016
Resolution: PSCO witnessed and received Lloyd's Register report attesting proper operation of port main engine.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 17 June 2014
Resolved
0988: The thermal and structural boundaries of the EGR are "class A" divisions and shall be constructed of steel or other equivalent material and shall be so constructed as to be capable of preventing the passage of smoke and flames. The deck separating the EGR and the air conditioning unit room is corroded and has various holes that compromises the thermal and structural boundary of the EGR.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 June 2014
Resolved 19 June 2014
Resolution: The PSCO received class report attesting to temporary repairs until proper repairs can be made to the deck separating the emergency generator room and air conditioning unit room and visually verified proper repairs.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 17 June 2014
Resolved
0715: Each section of detectors shall include means for giving a visual and audible alarm signal automatically at one or more indicating units whenever any detector comes into operation. PSCE's observed two separate indicators, 1 in the starboard steering gear flat and the other in the forward eng. room, that failed to give a visual indication upon activation of the general alarm.
Action required: 705 - Other - as specified
Due 1 July 2014
Resolved 19 June 2014
Resolution: PSCO witnessed the proper operation of general alarm visual indicators in the fwd engine room and in the steering flat.
Fire Fighting › Structural - A Class Divisions › Aux Spaces (moderate fire risk)
Issued 17 June 2014
Resolved
Condition of Class to repair Def. # 1 from activity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2014
Resolved 19 June 2014
Resolution: Cropped and renewed steel plating in the deckhead above emergency generator in order to maintain structural fire protection.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 May 2012
Resolved
provisions shall be made to prevent any part of the oil fuel system from discharging to position, in the opinion of the administration, is safe. The oil transfer pump is leaking excessively causing a fire risk near purifiers.
Action required: 705 - Other - as specified
Due 16 June 2012
Resolved 4 June 2012
Resolution: Received class report attesting to the oil transfer pump working as is designed with new packing put into place.
Construction/Loadline › Hull › Side Shell
Issued 19 July 2011
Resolved
There is a piece of fairing where the rail ferry joins the vessel that has fallen off. The fairing is not a structural member. Repair to the satisfaction of class within 14 days. 74SOLAS 2004 Cons Ch 1 Reg 11 to 17(a)(c)
Action required: 705 - Other - as specified
Due 2 August 2011
Resolved 2 August 2011
Resolution: Recieved Class Certificate from [name withheld] attesting to the satisfactory repairs on Starboard Fairing Cover Plate.
Fire Fighting › Structural - B Class Divisions › Doors
Issued 27 September 2010
Resolved
Self-closing device on wheel house access door from the accomodation space is missing. The door is part of a B class subdivision. Solas 74 unamended ch II-2 reg 24
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2010
Resolved 14 October 2010
Resolution: Class Report was sumitted atesting to repair.
Construction/Loadline › Markings › Load Line Mark
Issued 27 September 2010
Resolved
The ring lines and letters are were not in contrasting colors to the hull of the ship. The crew immediately fixed the problem once they were informed of the issue.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 September 2010
Resolved 27 September 2010
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 12 March 2009
Resolved
In the vessel's new generator room, observed several areas where openings and penetrations are not maintaining the A-60 boundary in accordance with their fire safety control plan. Both emergency exit doors are missing parts to the handle/lock. The forward door has the wrong handle/lock which allows the cut-out to be exposed. The forward door has two cut-outs allowing wires/cables to pass through.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2009
Resolved 1 May 2009
Resolution: The A-60 Boundaries have been examined by Class.
Fire Fighting › Fire Hoses › Condition
Issued 12 March 2009
Resolved
All hose stations on the main cargo deck were found not provided with necessary spanner wrenches. Vessel supplied wrenches, available on board, to match one type of connection. Vessel still needs another type of wrench to match the other type of hose connection.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2009
Resolution: Vessel purchased spanner wrenches for each hose station and is now in compliance with SOLAS 74 II-2/5.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 18 January 2008
Resolved
The vessel's machinery spaces, including the steering flat, engine room, fuel oil purifier room and bilges has excessive fuel oil and accumulations of oily waste presenting a fire, safety, and environmental hazard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2008
Resolution: CG inspector and Class witnessed clean-up of all machinery spaces.
Engineering › Steam System (main) › Piping
Issued 18 January 2008
Resolved
Steam leaking from a team pipe in engine room poses a personnel hazard directly above a walkway repair to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2008
Resolution: CG inspector and Class witnessed repair of steam line.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 18 January 2008
Resolved
The 24 volt monitoring system for both main diesel engines has exposed oil soaked wiring and monitoring points posing a significant safety hazard. Complete to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2008
Resolution: CG inspector and Class witnessed clean-up of 24 volt monitoring system and placing equipment in proper operation.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 January 2008
Resolved
Both starboard and port side hand rails have numerous wasted areas causing a significant safety hazard. Repair to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2008
Resolution: CG inspector and Class witnessed proper repairs to handrails.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 18 January 2008
Resolved
Starboard rescue boat is not in a state of continuous readiness. Engine can not start and boat can not be deployed within time limit. Repair to the satisfaction of class.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2008
Resolution: CG inspector and Class witnessed starboard rescue boat start and be deployed within 5 minutes.
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 18 January 2008
Resolved
Mooring winches and other ground tackle equipment are excessively worn and or wasted. Repair to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2008
Resolution: Mooring winches and other ground tackle equipment were removed by the vessel. Captain stated these items were not needed for mooring. Class attested to this action.
Fire Fighting › Structural - B Class Divisions › Doors
Issued 18 January 2008
Resolved
A class "B" fire door leading from the galley to the accommodation walkway doesn't close properly thus causing inadequate fire protection. Repair to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2008
Resolution: CG inspector and Class witnessed repair to class "B" fire door.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 18 January 2008
Resolved
Due to objective evidence discovered during and expanded examination in the ship's engine room and of the ship's maintenance procedures in accordance with the Safety Management System, an external audit is requested. To the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2008
Resolution: An external audit of the Safety Management System was conducted by class to determine that the vessels management system was in order but the vessel''s crew was not following it. Class attested to the SMS.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 18 January 2008
Resolved
Main engine leaking jacket water and oil mixture directly to the bilge from wasted piping system. Repair to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2008
Resolution: CG inspector and Class witnessed repair of the MDE jacket water system.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 7 January 2008
Resolved
Both port and starboard side anchors were lost while in transit into the Port of Mobile, AL.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 January 2008
Resolution: Received classification report attesting anchors being replaced and fully operational.
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 October 2006
Resolved
SECTOR New Orleans received request for Deviation to Enter due to only one of the two required independent marine radars operating.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2006
Resolution: Received satisfactory Tech Report.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 2 October 2006
Resolved
The No. 2 cylinder on the port main engine is leaking water excessively.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 October 2006
Resolved 2 October 2006
Resolution: Received class report from Llyods Register satisfying requirement.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 2 October 2006
Resolved
The rudder angle indicator on the bridge shows a seven degree variance than that on the steering gear room indicator.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 October 2006
Resolved 2 October 2006
Resolution: Received class report from Llyods Register satisfying requirement.
Engineering › Steering Gear System › Hydraulic Hose
Issued 2 October 2006
Resolved
The port side steering gear system has a slow hydraulic leak on the distribution box.
Action required: 705 - Other - as specified
Due 9 October 2006
Resolved 2 October 2006
Resolution: Received class report from Llyods Register satisfying requirement.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 2 October 2006
Resolved
The engine room has numerous containment areas and buckets filled with oil.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 October 2006
Resolved 2 October 2006
Resolution: Received class report from Llyod''s Register satisfying requirement.
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 21 September 2006
Resolved
The starboard main engine is inoperable until an appropriate oversized main bearing can be manufactured. The vessel was given a condition of class and a DTD from Sector NOLA allowing it to transit on only the port M/E as long as tugs of adequate hp are in escort while in restricted waters or when maneuvering until the starboard M/E is operating as required.
Action required: 705 - Other - as specified
Due 21 September 2006
Resolved 2 October 2006
Resolution: Received class report from Lloyds Register satisfying requirement.
Engineering › Diesel Engine (propulsion-direct drive) › Piston Rod
Issued 19 July 2006
Resolved
OIL LEAKS PRESENT AT THE BASE OF PUSH ROD COVERS WHERE COVERS MEET WITH THE TOP OF THE ENGINE. REPAIR TO THE SATISFACTION OF THE ATTENDING CLASSIFICATION SOCIETY.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: Received class report from LR satisfying requirement.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 19 July 2006
Resolved
OILY WATER SEPARATOR OIL CONTENT METER AND ALARMS ARE NOT OPERATING PROPERLY. PROVE PROPER OPERATION OF OILY WATER SEPARATOR.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: Received class report from LR satisfying requirement.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 13 January 2005
Resolved
Vessel sustained damage to the #5 cylinder on the starboard main engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2005
Resolution: Recived class report attesting to the working order of the starboard engine.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 19 November 2004
Resolved
Repair turbocharger main bearing failure for the starboard main diesel engine as required by SOLAS I/11.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 November 2004
Resolved 3 December 2004
Resolution: Received Lloyd''s Register report attesting to the repairs to the starboard main engine turbocharger rotor assembly including replacement of both rotor bearings and sealing bushes. Main engine turbocharger operating satisfactorily.
Electrical › Lighting (service) › Lighting Fixture
Issued 30 September 2004
Resolved
Replace/repair general lighting fixture between #2 & #3 service generators.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2004
Resolved 26 October 2004
Resolution: Light fixture replaced.
Engineering › Steam Boiler (auxiliary/waste heat) › Blowdown System
Issued 30 September 2004
Resolved
Repair leaking valve and pipe on boiler blowdown.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2004
Resolved 3 December 2004
Resolution: Lloyd''s Register issued report and certificate attesting to the satisfactory repairs and operation of the boiler blow-down valve and pipe work.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 30 September 2004
Resolved
Make OWS in forward engineering space ready for functional test.
Action required: 705 - Other - as specified
Due 29 October 2004
Resolved 26 October 2004
Resolution: OIly water separator tested to satisfaction of inspector
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 30 September 2004
Resolved
Repair/Replace the self igniting light on the starboard side #2 lifebuoy. Light will not ignite when deployed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2004
Resolved 26 October 2004
Resolution: Light will now ignite.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 30 September 2004
Resolved
Provide machinery guard for belt, port main engine, outboard side, aft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2004
Resolved 26 October 2004
Resolution: Guard installed
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 30 September 2004
Resolved
Remove trash and stow medical supplies in hospital space as per ILO 147.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2004
Resolved 26 October 2004
Resolution: Supplies stowed and trash removed.
Engineering › Steam System (auxiliary)
Issued 10 March 2004
Resolved
Noted soft patch on steam pipe adjacent to fuel oil purifiers. The patch was plastic twine and steam was leaking from the patch. SOLAS 74/78 II-1/ Reg 3-1 LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2004
Resolved 26 March 2004
Resolution: Norm Coventry from lloyds Register attended the vessel and attested to repairs made on the steam line.
Fire Fighting › Combustible Materials
Issued 10 March 2004
Resolved
Machinery spaces have excessive amounts of fuel oil on deck plates and in bilges. Solas 74/78 II-1/Reg 3-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2004
Resolved 26 March 2004
Resolution: CG Inspectors attended the vessel and noted that the excessive amount of oil on the deck plates and bilges was cleaned to the satisfaction of the CG.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 10 March 2004
Resolved
Starboard engine exhaust lagging is detiorated causing exhaust leaks. Lagging to be replaced. SOLAS 74/78 II-1/Reg 3-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2004
Resolved 26 March 2004
Resolution: Norm Coventry from Lloyds Register attended the vessel and attested to the repairs the the exhaust leaks in the starboard engines lagging.
Personnel › Certificates/Documents/Licenses
Issued 10 March 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2004
Resolution: Received certificate of endorsement from MPA singapore for all officers.
Lifesaving › Lifejacket/PFD (General)
Issued 10 March 2004
Resolved
Retroreflective tape on several lifejackets worn to the point where they no longer reflect light. SOLAS 74 III/Reg 30.2.7 LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2004
Resolution: Retro was replaced on all life jackets.
Engineering › Steering Gear System
Issued 10 March 2004
Resolved
Noticed leaks in numorous locations on the steering gear. SOLAS 74/78 II-1/REG 29.21 LEGACY COMPONENT DESC: Ram Seal
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2004
Resolved 26 March 2004
Resolution: Norm Coventry from Lloyds Register attended the vessel and attested to the repairs of the leaks on the steering gear.
Pollution Prevention/Response › Prevention Equipment
Issued 10 March 2004
Resolved
Noticed 3 inch diameter hole in aft portion of marine sanitation device. 33 CFR 159.7 (c) LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 11 March 2004
Resolution: A steel patch was welded over the hole and the system was under pressure with no visable leaks.
Electrical
Issued 23 January 2001
Resolved
PERMENANTLY CAP OFF THE UNUSED/DEAD CABLES NEAR THE EMERGENCY FIREPUMP._x001C_ SOLAS 74 (AMMENDED) II-1 /45.1
Condition: Unknown
Due 6 February 2001
Resolved 5 March 2001
Documentation
Issued 23 January 2001
Resolved
PROVIDE UPDATED TRANSFER PROCEDURES WITH RESPECT TO VSLS NEW CONFIGURATION AS OF 1995. 33CFR 155 SUBPART C
Condition: Unknown
Due 6 February 2001
Resolved 5 March 2001
Unknown
Issued 23 January 2001
Resolved
PUMP OUT BILGE AND HOLDING TANK WASTE TO AN APPROVED SHORESIDE FACILITY. FAX A COPY OF THE FACILITY RECEIPT PRIOR TO DEPARTURE. MARPOL 73/78 ANNEX 1/17.
Condition: Unknown
Due 23 January 2001
Resolved 11 April 2001
Documentation
Issued 23 January 2001
Resolved
CLASS TO PROVIDE NEW APPROVED CARGO SECURING MANUAL THAT REFLECTS THE CARRIAGE OF RAILCARS._x001C_ SOLAS 74 (AMMENDED) IV/ 5.6
Condition: Unknown
Due 6 February 2001
Resolved 5 March 2001
Documentation
Issued 23 January 2001
Resolved
CLASS TO PROVIDE STABILTIY BOOK APPROVAL TAKING INTO ACCOUNT ALL NEW ALTERATIONS CARRIAGE OF RAILCARS_x001C_ SOLAS 74 (AMMENDED) II-1/22.1_x001C_ _x001C_
Condition: Unknown
Due 6 February 2001
Resolved 5 March 2001
Unknown
Issued 23 January 2001
Resolved
ELIMINATE (LEGALLY) STANDING SEWAGE IN HOLDING TANK._x001C_ 33 CFR 159.7
Condition: Unknown
Due 23 January 2001
Resolved 14 February 2001
Unknown
Issued 23 January 2001
Resolved
PERFORM AN INFLATABLE TEST/DRILL ON 1 DAVIT LAUNCHED LIFERAFT PRIOR TO DEPARTURE. SOLAS 74 (AMMENDED) III/18
Condition: Unknown
Due 23 January 2001
Resolved 14 February 2001
Documentation
Issued 23 January 2001
Resolved
CLASS TO PROVIDE A NEW IOPP CERT THAT IS APPROPRIATE TO THE VSL. GIVEN ITS ALTERATIONS IN 1995. CURRENTLY THE IOPP CERT. IS THAT OF A TANKSHIP._x001C_ MARPOL 13/78 ANNEX 1/5
Condition: Unknown
Due 6 February 2001
Resolved 5 March 2001
Unknown
Issued 23 January 2001
Resolved
HAVE CLASS PROVIDE A DETERMINATION IF THE SLUDGE PUMP USED TO ACTUALLY PUMPTHE WASTES OFF THE VSL HAS THE CAPACITY TO HANDLE ITS LOAD IN ALL SITUATIONS, EVEN WITH THE VARYING TEMPATURES. IF NOT, PROVIDE MEANS THAT WILL ENABLE SMOOTH AND EFFECIENT OPERATIONS IN ALL CONDITIONS.
Condition: Unknown
Due 6 February 2001
Resolved 5 March 2001
Unknown
Issued 23 January 2001
Resolved
CLASS TO PROVIDE REPORT ATTESTING TO THE PROPER OPERATION OF THE MSD. IF NOT, GIVE PROPOSAL TO REPLACE/ RENEW IN KIND. _x001C_ 33 CFR 159.7 (C)
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Unknown
Issued 23 January 2001
Resolved
FLAG TO EXPOUND ON DETERMINATION AS TO WHY DAVIT LAUNCHED LIFERAFTS ARE INSTALLED O/B AS OPPOSED TO LIFEBOATS AS REQUIRED IN SOLAS 74. PER SOLAS 74 (AMENDED) CH. I/5(b) IMO MUST DETERMINE IF DAVIT LAUNCHED LIFERAFTS ARE A VIABLE ALTERNATIVE TO LIFEBOATS AND PROVIDE APPROVAL DOCUMENTATION.
Condition: Unknown
Due 19 July 2001
Resolved 19 July 2001
Unknown
Issued 18 August 1992
Resolved
VESSEL'S CREW WAS UNABLE TO SHOW PROOF OF PROPER DISPOSAL OF SHIP'S GARBAGEAND PLASTICS.
Condition: Unknown
Due 14 February 2001
Resolved 14 February 2001
Engineering
Issued 21 August 1990
Resolved
33CFR155.370(a)(2) VSL'S OILY-WATER SEPARATING EQUIPMENT WAS NOT OPERATING._x001C_ AUTH CITE: 33 USC 1321(j)(1) PEN CITE: 33 USC 1321(j)(2)_x001C_ _x001C_
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Navigation
Issued 4 August 1986
Resolved
VESSEL DID NOT HAVE CURRENT CORRECTIONS TO CHARTS #11342 & #11343 ON BOARD AS REQUIRED BY 33CFR164.33(A)(1)(II).
Condition: Unknown
Due 4 August 1986
Resolved 4 August 1986