SPRUCEGLEN is a 1983 freight ship. The Coast Guard has recorded 20 inspections since 2016, most recently in July 2025, along with 6 deficiencies and 1 operational control, 1 with no removal date recorded.

Records from 2016 to 2025. Most recent: inspection, 17 July 2025.

Built
1983
Last inspected
17 July 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 July 2025
…with no type recorded5
Operational controls 1 with no removal date recorded
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8119261
227281
Flag
CANADA
Maury page id
psix-227281

Documentation record

Tonnage as PSIX records it22388 - Convention (Subpart B), Gross Ton
36248 - Dead Weight, Ton
11648 - Convention (Subpart B), Net Ton
45768 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

17 July 2025 In-Service Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8187783
12 May 2025 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8133111
29 October 2024 PSC B
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8025202
29 May 2023 Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7701008
22 May 2023 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7692047
26 April 2023 ISM Exam · PSC A
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7674478
5 August 2022 Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7525456
5 April 2022 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7425825
16 July 2021 Canadian Vsl Safety Exam (D9 only) · PSC B
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7258315
5 May 2021 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7191650
6 October 2020 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7072461
17 April 2020 Canadian Vsl Safety Exam (D9 only)
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6940522
17 December 2018 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6615088
20 November 2018 Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6584167
1 November 2018 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6587661
16 October 2018 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6580758
15 October 2018 Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6561350
2 October 2017 Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6279492
22 September 2017 Type not recorded
No type recorded · Station Sault Ste Marie · USCG Great Lakes District (CGD-GL) · Activity 6273053
3 October 2016 Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6014829

Deficiency record · 6

02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 12 May 2025 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to Ensure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter. Vessel report a pinhole leak through the side shell plate of the hull into the #6 Port side Ballast tank IVO FR 55 approx. 15ft above waterline and 10ft below the main deck. Vessel intends to conduct repairs in Sorel, CA and will have Class attend to verify repairs. 46 CFR 91.30-1(a) - 40 - ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 September 2025
Resolution: Temporary (23May) followed by permanent repairs (7Sept) were made to the staisfaction of RO.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 April 2023 Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. PSCO identified 04 life raft servicing certificates issued to the vessel with expired seam test dates.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2023
Resolution: Received servicing report from provider with corrected dates
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 26 April 2023 Resolved
The generator set must be capable of carrying its full rated load within 45 seconds. Vessel's emergency source of power's starter is not functioning properly. Crew is using secondary means of power to start generator in the event of a blackout.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2023
Resolved 22 May 2023
Resolution: conducted multiple test of starter.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 26 April 2023 Resolved
quipment per Safety Management System (SMS). During PSC inspection, PSCO identified emergency generator would not consistently start by primary means. Upon review of the vessel's SMS, the last update to the request was 17APR2023 with no purchase of additional spares and no further comments by company to the vessel. Recommend external audit of CSL GROUP INC.'s Safety Management System for adherence to and verification of implementing corrective actions for urgent requests for critical pieces of equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2023
Resolved 30 May 2023
Resolution: Vessel provided documentation from class of a ISM external audit occurring.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 May 2021 Resolved
Except as provided in chapter 37 and section 3505 of this title, a foreign vessel of a country having inspection laws and standards similar to those of the United States and that has an unexpired certificate of inspection issued by proper authority of its respective country, is subject to an inspection to ensure that the condition of the vessel is as stated in its current certificate of inspection. A foreign country is considered to have inspection laws and standards similar to those of the United States when it is a party to an International Convention for Safety of Life at Sea to which the United States Government is currently a party. A foreign certificate of inspection may be accepted as evidence of lawful inspection only when presented by a vessel of a country that has by its laws accorded to vessels of the United States visiting that country the same privileges accorded to vessels of that country visiting the United States. Vessel's documentation does not meet the requirements in the bilateral agreement between United States and Canada. Vessel must comply with international regulations or reciprocity requirements per the bilateral agreement. (17ac)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2021
Resolution: Vessel was issued a new certificate reflecting upddated routes.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 15 October 2018 Resolved
Suspect SMS is not being used as required. Issued Form -B- requirement, recommending third party conduct an audit of the company's and ship's Safety Management System.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2018
Resolved 20 November 2018
Resolution: DNV-GL conducteded 3d party SMS audit and listed two non-conformities. Deficiency cleared.

Ownership record