Inspection history · 52
5 September 2025
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8227835
3 April 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8104538
24 February 2025
PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8083659
3 December 2024
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8042876
1 November 2024
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8081598
26 August 2024
PSC A
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7983351
15 July 2024
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7958631
18 January 2024
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7850939
21 October 2023
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7810881
29 March 2023
Ballast Water Examination · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7659066
7 September 2022
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7553423
25 February 2022
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7400812
19 October 2021
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7334891
8 October 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7329166
16 August 2021
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7288432
5 August 2021
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7278777
21 April 2021
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7180251
21 April 2021
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7205868
8 February 2021
PSC B · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7136455
24 October 2020
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7083584
9 August 2020
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7027554
9 July 2020
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7001787
19 June 2020
PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6974062
18 September 2019
PI Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6815051
14 March 2019
PI Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6642665
1 March 2019
ISPS II Exam · PII Safety Exam · In-Service Inspection · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6634785
28 February 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6635030
8 January 2019
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6607061
25 December 2018
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6603153
24 December 2018
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6602547
23 December 2018
NPV Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6600508
20 December 2018
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6601075
16 December 2018
NPV Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6599185
13 December 2018
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6597458
12 December 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6610599
27 October 2018
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6569321
7 October 2018
NPV Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6556457
5 October 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6555393
5 October 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6559963
15 August 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6513523
21 June 2018
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6451691
20 June 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6450084
20 June 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6450490
20 February 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6357996
20 February 2018
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6358330
20 February 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6360681
20 December 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6326927
20 December 2017
NPV Safety Exam · ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6327119
20 December 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6456199
22 July 2017
ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6216975
6 April 2017
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6118957
25 April 2016
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5862263
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 24 February 2025
Resolved
Every company should develop, implement, and maintain a safety management system which includes the following functional requirements: instructions and procedures. SMS cybersecurity plan states, "Users must protect their application password confidentiality" Password posted on monitor for terminal used to update ECDIS. Note: Vessel must conduct internal audit to ensure SMS cyber hygiene is properly implemented.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 April 2025
Resolved 4 March 2025
Resolution: Vessel conducted internal audit, def cleared. see documents
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed excessive water leak on vessel's NO.2 Ballast Pump while idle.
74 SOLAS (20) I/11.a
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2023
Resolution: Cleared deficiency after final class report as been submitted from class.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 19 October 2021
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA. PSCO OBSERVED THE HYDRAULIC MOTORS FOR HATCH COVER OPERATION ON #5 AND #7 CARGO HOLD WERE HEAVILY LEAKING HYDRAULIC OIL. 74 SOLAS(20)I/11(A) 50 AC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 12 November 2021
Resolution: Vessel submitted class report attesting to tightening of pump connections.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2021
Resolved
AFTER ANY SURVEY OF THE SHIP UNDER REGULATIONS 7,8,9, OR 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT, AND OTHER ITEMS. PSCO OBSERVED THAT EXPLOSION PROOF LIGHTING IN THE PAINT LOCKER AND FORWARD STOWAGE COMPARTMENT WAS BROKEN AND NO LONGER EXPLOSION PROOF. 74 SOLAS ((20)i/11(B) 50AC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 12 November 2021
Resolution: Vessel submitted class report attesting to replacement of explosion proof lights.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 August 2021
Resolved
ARRANGEMENT FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE OIL USED IN PRESSURE LUBRICATION SYSTEMS SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ONBOARD. PSCO OBSERVED OIL LEAK ON LUBE OIL PURIFIER.
74SOLAS(20) II-2/33.B
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2021
Resolution: Connection was properly tightened and leakage was fixed. Attending class surveyor approved repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 16 August 2021
Resolved
NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS MACHINERY, EQUIPMENT, ETC. COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. PSCO FOUND A COOLING WATER LEAK ON THE MAIN COOLING LINE FOR SHIPS GENERATORS. AS WELL AN ATTEMPTED REPAIR TO THE LEAK BY MEANS OF HOSE CLAMP AND RUBBER.
74SOLAS(20) II-2/33.a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2021
Resolution: Defective welds were gouged and rewelded, pipes were pressure tested and foudn satisfactory. Repairs were approved by attending class surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 August 2021
Resolved
ARRANGEMENT FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ONBOARD. PSCO OBSERVED FUEL SOAKED LAGGING ON FUEL OIL MODULE.
74SOLAS(20) I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2021
Resolution: Oil soaked lagging was removed and replaced, surrounding oil was cleaned. Repairs were certified by attending class surveyor.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 16 August 2021
Resolved
EFFICIENT GUARD RAILS OR BULLWARKS SHALL BE FITTED TO ALL EXPOSED PARTS OF THE FREEBOARD AND SUPERSTRUCTURE DECKS. PSCO OBSERVED BROKEN LOWER GUARD RAIL NEAR STARBOARD MUSTER STATION.
ICLL (66) 25.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 August 2021
Resolution: See attached report
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 August 2021
Resolved
THE CONSTRUCTION OF ALL DOORS AND FRAMES IN "A" CLASS DIVISIONS, WITH THE MEANS OF SECURING WHEN CLOSED, SHALL PROVIDE RESISTANCE TO FIRE AS WELL AS TO THE PASSAGE OF SMOKE AND FLAME, AS FAR AS PRACTICABLE, EQUIVALENT TO THAT OF THE BULKHEADS IN WHICH THE DOORS ARE SITUATED. PSCO OBSERVED ENGINE ROOM ESCAPE DOOR UNABLE TO CLOSE, DUE TO POSSIBLE DEFORMATION OF FRAME AND/OR DOOR. ENGINE ROOM ESCAPE DOOR ALSO MISSING SEALING STRIP ON BOTTOM OF DOOR FRAME.
74 SOLAS II-2/23.d
Action required: 10 - Deficiency Rectified
Resolved 16 August 2021
Resolution: Vessel fixed inoperable door and replaced the missing sealing strip on bottom of door frame.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 16 August 2021
Resolved
AN ELECTRICAL SAFETY LAMP (HAND LANTERN) OF AN APPROVED TYPE WITH A MINIMUM BURNING PERIOD OF THREE HOURS. PSCO OBSERVED 01 FIREFIGHTER WITHOUT LANTERN AND 01 FIREFIGHTER WITH INOPERABLE LANTERN.
74 SOLAS II-2/ 14.a.iv
Action required: 10 - Deficiency Rectified
Resolved 16 August 2021
Resolution: Vessel was trained on proper stowage of rechargeable fire fighter hand lanterns.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 16 August 2021
Resolved
FOOD RATION, DETERMEINED BY THE ADMINISTRATION, FOR EACH PERSON THE LIFEBOAT IS CERTIFIED TO CARRY. THESE RATIONS SHALL BE KEPT IN AIRTIGHT RECEPTACLES WHICH ARE TO BE STOWED IN A WATERTIGHT CONTAINER. PSCO OBSERVED 07 FOOD RATIONS THAT WERE NOT WATERTIGHT.
74 SOLAS III/11.a.xii
Action required: 10 - Deficiency Rectified
Resolved 16 August 2021
Resolution: Vessel had replacement food rations on board and replaced all 07 food rations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 April 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the resent regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The M/V HONOURABLE HENRY JACKMAN reported their main engine shut off during mooring evolution at the Port of Redwood City, CA.
74 SOLAS(14) 1/11(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 April 2021
Resolution: Both M/E starting air distributor overhualed and replaced for cylinders No.1 and No.6. LR surveryor conducted satisfactory tests following overhaul. See report for additional details.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 8 February 2021
Resolved
ICLL 8
The ring lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. PSCO observed the Load Line was rusted and not contrasting color.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 February 2021
Resolution: Load line markings repainted and attested to by LR surveyor.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 February 2021
Resolved
74SOLAS(UnAmend)1/11
After any survey of the ship under regulation 7,8,9,10 of this chapter, has been approved, no change shall be made in the structural arrangements, machinery, equipment etc. covered by the survey, without the saction of the administration. PSCO observed unapproved dryer installation. Improper dryer ventilation installed to ducting.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 February 2021
Resolution: Dryer was removed and removal was attested to by LR surveyor.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 2 March 2019
Resolved
Each operation shall be fully recorded without delay in the oil record book part 1. The orb part 1 was found missing 02 weekly entries for weekly soundings on the following dates: 10FEB2019 and 24FEB2019.
MARPOL I/17.4
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2019
Resolved 4 March 2019
Resolution: Refer to Class Report. Rectified to satisfaction of USCG.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 2 March 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the convention and the protocol to ensure that the ship in all respects will remain fit to proceed to sea without the ship or persons onboard. The overboard sewage gate valve is leaking. Crew was unaware of the leakage.
74SOLAS I/11(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 March 2019
Resolved 4 March 2019
Resolution: Refer to class report. Rectified to satisfaction of US Coast Guard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 2 March 2019
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark background, or in black on a light background. The marks shall be plainly visible. Load line markings on the port side of the ship are non contrasting and are not clearly visible.
ICLL 66 Annex I/8
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 March 2019
Resolved 23 March 2019
Resolution: Load Line Painted. USCG Onboard, observed load line. All Sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 2 March 2019
Resolved
Efficient guard rail or bulwarks shall be fitted to all exposed parts of freeboard and superstructure decks. Topside guard rail on starboard side is broken and does not provide adequate protection for crew.
ICLL 66 Annex I/25
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 March 2019
Resolved 4 March 2019
Resolution: Refer to class report. Rectified to satisfaction of US Coast Guard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the convention and the protocol to ensure that the ship in all respects will remain fit to proceed to sea without the ship or persons onboard. The fire main piping was found with 01 soft patch located on the branch line near the lower fire station.
74 SOLAS I/11(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 March 2019
Resolved 4 March 2019
Resolution: Refer to class report. Rectified to the satisfaction of the US Coast Guard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 March 2019
Resolved
Before the ship leaves port and at all times during the voyage all life saving appliances shall be in working order and ready for immediate use. 02 life buoys were found to be missing the required reflective tape. One of the life rings was also found with a non-operational light. Crew has replaced reflective tape and light on life buoys.
74 SOLAS III/20.2
Action required: 10 - Deficiency Rectified
Due 2 March 2019
Resolved 2 March 2019
Resolution: Rectified on the spot.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 March 2019
Resolved
Fire hoses shall be of material approved by the administration and sufficient in length to project a jet of water to any of the spaces in which they may be reuqired. 01 fire hose was found in the engine room with a torn liner. Crew replaced fire hose with spare onboard the vessel.
74 SOLAS II-2/5(f)
Action required: 10 - Deficiency Rectified
Due 2 March 2019
Resolved 2 March 2019
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 March 2019
Resolved
After any survey of the ship, no change shall be made without the sanction of the Administration. The jacket cooling water system for the main engine is not operating as intended. When the main engine is not in operation, the jacket water is actively leaking from cylinders causing the crew to run flexible hoses from the cylinders to the bilge.
74 SOLAS I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2019
Resolved 4 March 2019
Resolution: Refer to class report. Rectified to the satisfaction of the US Coast Guard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 March 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the Convention and the present Protocol to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Heavy exhaust discharge from the main engine within the engine room was witnessed by PSC team during ignition and transition between ahead and astern propulsion. Both PSCOs' 4-gas detectors alarmed when entering the vicinity of the main engine. Approximately 40% of the E/R overhead space is covered in exhaust residue. Crew noted that this has been a reoccurring issue for the past 2 months. Required that the vessel supply a marine chemist to gas free the space to ensure that the space is safe for work.
74 SOLAS I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 2 March 2019
Resolved 4 March 2019
Resolution: Detention lifted.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 March 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the Convention and the present Protocol to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. 03 different sections of the bilge were found with thick waste oil accumulation. Locations of oily bilge water include underneath the shaft, port side of the main engine beneath a leaking drain pipe, and throughout the area around the lube oil purifier section of the engine room. Specifically, the area around the shaf was approximately 3 feet deep with oily water. The crew attempted to remove the majority of oil from the bilge.
74 SOLAS I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 1 March 2019
Resolved 4 March 2019
Resolution: Detention lifted.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 23 December 2018
Resolved
Fire fighter's outfits shall comply with the Fire Safety Systems Code. Fire Fighter outfits had hood protection of neck, face, and shoulders that were not afixed to helmet and were not donned for fire drill. Fire fighter's neck was exposed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 December 2018
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 16 December 2018
Resolved
Vessel not able to lift port side anchor due to malfunction of portside fwd windlass. SOLAS Ch I, Reg 11
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 December 2018
Resolution: Class report received. Deficiency rectified. See attached Class Report.