MAURY USCG vessel records Sign in
← All vessels

ATLANTIC SUPERIOR

ATLANTIC SUPERIOR is a 1982 freight ship. The Coast Guard has recorded 110 inspections since 1984, most recently in August 2014, along with 44 deficiencies and 11 operational controls.

Records from 1984 to 2014. Most recent: inspection, 27 August 2014.

Built
1982
Last inspected
27 August 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7927805 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228083
Flag
BAHAMAS, THE
—
Maury page id
psix-228083

Inspections, by type

…with no type recorded68
Years with a record 24 calendar years (1984–2014)
The 110 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it23955 - Regulatory (Subpart C or D), Gross Ton
38510 - Dead Weight, Ton
11084 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

VICKI M MCALLISTER Towing Vessel · MISLE 27891 · 13 January 2005 · activity 2276501STAMFORD Towing Vessel · MISLE 67795 · 13 January 2005 · activity 2276501AMERICAN CHAMPION Towing Vessel · MISLE 140032 · 13 January 2005 · activity 2276501JAY CASHMAN Industrial Vessel · MISLE 665369 · 13 January 2005 · activity 2276501

Inspection history · 110

27 August 2014 PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4961415
28 June 2014 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4902277
28 June 2014 Damage Survey · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4902626
1 June 2014 PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4870827
15 March 2014 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4816639
14 March 2014 Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4816372
12 March 2014 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4815185
1 March 2014 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4808313
12 March 2010 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3694424
7 April 2009 ISPS III Exam · PII Safety Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3447826
4 November 2008 Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3357192
3 November 2008 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3356684
21 October 2008 PII Safety Exam · ISPS III Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3348621
16 September 2008 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3325863
2 September 2008 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3318301
16 August 2008 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3299409
25 April 2008 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3192121
20 April 2008 Random ISPS/MTSA/PSC
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3187953
15 March 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3165186
15 March 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3167400
5 January 2008 Random ISPS/MTSA/PSC
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3124845
11 December 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3113956
8 November 2007 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3095278
12 October 2007 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3078297
5 September 2007 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3049770
17 June 2007 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2966314
4 June 2007 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2951576
4 June 2007 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2984517
11 April 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2905675
10 April 2007 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2905621
26 March 2007 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2895819
9 October 2006 ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2796636
14 August 2006 Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2747204
28 July 2006 Deficiency Check
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2750622
21 July 2006 Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2720058
19 July 2006 Type not recorded
No type recorded · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2719304
27 February 2006 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2592816
17 February 2006 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2587085
27 October 2005 Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2523036
6 October 2005 ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2508905
14 January 2005 NPV Safety Exam
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2275166
13 January 2005 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2276501
16 August 2004 ISPS II Exam · NPV Safety Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2167274
22 July 2004 PII Safety Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2141323
8 January 2004 Annual Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1979788
4 August 2003 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1866385
12 February 2003 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1743672
25 November 2002 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1710283
25 October 2002 Ballast Water Examination · Annual Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1693423
2 October 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 294444
8 June 2001 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 290749
29 April 2001 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 289574
16 January 2001 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 285983
11 September 2000 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 281867
28 July 2000 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 280379
17 February 2000 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 287163
12 January 2000 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 273421
13 August 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 431577
1 March 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 425924
3 February 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 425097
13 December 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 84966
7 November 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 422404
22 April 1998 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 716789
18 April 1998 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 90286
3 April 1998 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 413886
22 February 1998 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 413031
13 April 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 402506
13 March 1997 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 401322
4 March 1997 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 401093
15 December 1996 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 59525
13 June 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 513686
1 March 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 388635
7 December 1995 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 385559
5 July 1995 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 380091
20 June 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 379677
18 April 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 705032
12 April 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 377282
7 April 1995 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1167528
23 December 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 373895
23 December 1994 Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1164017
3 October 1994 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 540015
15 September 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 370533
15 September 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1171232
4 September 1994 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 370071
4 September 1994 MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1356811
30 August 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 369858
30 August 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 868887
14 August 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 369404
14 August 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 867731
1 July 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 368094
1 July 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1179371
20 June 1994 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1328675
8 June 1994 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 476263
8 June 1994 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1324647
1 June 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 367275
28 January 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 364069
29 December 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 363297
18 June 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 358908
9 June 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 104763
27 January 1993 Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1137540
26 January 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 5925
18 December 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 462388
31 January 1987 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 446419
18 May 1986 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 309010
4 May 1986 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 308602
20 January 1986 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 508076
13 September 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 304226
25 May 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 302163
15 February 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 531226
12 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975959

Deficiency record · 44

Construction/Loadline › Hull › Side Shell
Issued 28 June 2014 Resolved
0938-After any survey of the ship under regulations 7, 8, 9 or 10 of this chapter has been completed, no change shall be made in structural arrangements covered by the survey. A 17in crack identified in No.3 Port Water Ballast Tank at Frame 119. 74SOLAS Ch.I/11 (17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2014
Resolved 3 July 2014
Resolution: 03JUL14- LR Certified welder completed repairs on 17in crack to the satisfaction of Class Surveyor and USCG Exam team. 05 Photograhs 01-02 on 27JUN14 to 03-05 on 03JUL14 attached into activity #4902626 with Surveyor and International Inspection pending.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 October 2008 Resolved
Electrical cable tray cover missing on starboard side of main deck. Cover was missing due to weather conditions out at sea. Cite: Solas 74/Ch. II-1/Reg. 27(a).
Condition: Damaged By Earlier Event
Due 8 November 2008
Resolved 31 October 2008
Resolution: Replaced missing electrical cable tray.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 25 October 2008 Resolved
Electrical cableway on forward mast is damaged due to weather conditions at sea. Cite: Solas 74/Ch. II-1/Reg. 27(a)(vi).
Condition: Damaged By Earlier Event
Due 8 November 2008
Resolved 31 October 2008
Resolution: Cable retaining brackets were reweld and replaced.
Navigation › Collision/Grounding Avoidance › Radar
Issued 2 September 2008 Resolved
Vessel has inoperable secondary radar. Issued a LOD.
Action required: 15 - Rectify deficiencies by next port
Resolved 5 September 2008
Resolution: Received technician report stating loaner modulator radar was installed and is fully operational.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 August 2008 Resolved
Replace inop life bouy light.
Due 16 August 2008
Resolved 16 August 2008
Resolution: Replaced light prior to CG departure.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 April 2008 Resolved
Light covers in engine room missing in way of generator flat. Replace to sat of class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 April 2008
Resolution: class attest to light covers being replaced.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 April 2008 Resolved
Light fixture and bracket wasted in way of lower level tunnel entry forward. Replace/repair as originally installed to sat of class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 April 2008
Resolution: Brackets repaired and new light fixture installed at lower level tunnel.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 20 April 2008 Resolved
Emergency fire pump lubricator head tank sight glass leaking. Repair as original to sat of class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 April 2008
Resolution: Sight glass removed and hardware overhauled. Sight glass checked for leaks and none found.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 20 April 2008 Resolved
Bracket(s) for the wire run housing on the main deck broken in various places. Repair as original to sat of class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 April 2008
Resolution: U bolts that hold the wire run housing in place have been replace where found necessary.
Electrical › Electric Generation Source (emergency) › Generator
Issued 12 October 2007 Resolved
Emergency diesel generator cannot be operated as intended. Engine exhaust expansion joint is completely separated allowing exhaust gases to leak excessively into generator space. Repairs to be made to the satisfaction of class. SOLAS 74 II-1/26
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 October 2007
Resolution: Vessel sent class report and photographic evidence of approved repairs which included new part(s) Information was received via email to [name withheld].
Engineering › Compressed Air System (start air) › Compressor
Issued 12 October 2007 Resolved
The air dryer for main engine starting air has temporary wiring arrangement. Vessel engineers have parts to complete permanent repairs/install as necessary. SOLAS 74 II-1/27
Action required: 705 - Other - as specified
Due 12 November 2007
Resolved 8 November 2007
Resolution: Rcvd calss report
Engineering › Steam System (main) › Piping
Issued 12 October 2007 Resolved
Sight glass for boiler condensate tank is cracked and has temporary repair. Repair glass as original. SOLAS 74 II-1/26-1
Action required: 705 - Other - as specified
Due 12 November 2007
Resolved 8 November 2007
Resolution: rcvd calss report
Stability › Weathertight Integrity › General
Issued 12 October 2007 Resolved
Multiple windows above superstructure are no longer weather tight. Port side window in crew mess is wasted. Bridge window on port side has wire running through a bolt hole. Starboard side window in accommodation space has a radio antennae protruding out of the hull below window. ILLC Annex I/23.50(A)(b)
Action required: 705 - Other - as specified
Due 12 November 2007
Resolved 8 November 2007
Resolution: Rcvd class report
Engineering › Steering Gear System › Pump
Issued 5 June 2007 Resolved
A Maryland Pilot made an initial report that the steering gear was not responding properly. Conducted satisfactory steering gear test. Proper operation of vessel's steering gear is to be proven to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 June 2007
Resolution: Received tech and class report. See scanned copies in the "documentation/certificates" tab for more details.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 21 July 2006 Resolved
narritive
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 July 2006
Resolved 14 August 2006
Resolution: Received class report stating vessel has made temporary repairs until Dec ''06.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 17 February 2006 Resolved
Exhaust piping on L/O purifier is not properly connected. The two pipes should be connected together to prevent exhaust from entering the L/O purifier room located in the engine room.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 February 2006
Resolution: Recieved class report.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 February 2006 Resolved
Alarm in engine room for 2nd oily water seperator does not work.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 February 2006
Resolution: Recieved class report.
Fire Fighting › Fire Pumps › Pressure
Issued 22 July 2004 Resolved
DURING FIRE DRILL UNABLE TO CHARGE FIRE HOSES DUE TO EXTREME LOW TEMP. ISSUED DEFICIENCY TO CHARGE HOSES IN NEXT PORT THAT HAS BETTER WEATHER.
Due 22 July 2004
Resolved 22 July 2004
Resolution: Completed satisfactory fire drill.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 8 January 2004 Resolved
DURING BOAT DRILL STBD BOAT WOULD NOT START DO TO EXTREME LOW TEMP.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 January 2004
Resolved 8 January 2004
Resolution: SHIP WAS ABLE TO RIG UP A HEAT LAMP TO GET BOAT RUNNING.
Construction/Loadline › Hull
Issued 25 October 2002 Resolved
Make permanent repairs to the satisfaction of class a fracture in the side shell plating port side iwo frame 135 adjacent to weld attachement of the frame. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 30 November 2002
Resolved 25 November 2002
Resolution: DEFICIENCY HAS BEEN CLEARED THROUGH CLASS REPORT.
Unknown
Issued 3 February 1999 Resolved
COMMUNICATION SYSTEM FROM BRIDGE TO STEERING GEAR SPACE WAS INOPERATIVE, A VIOLATION OF SOLAS 74/78 CHII-1 REG 29.10. CORRECT PRIOR TO 03 MAR 99.
Condition: Unknown
Due 3 March 1999
Resolved 2 March 1999
Unknown
Issued 3 February 1999 Resolved
TELEPHONE SYSTEM FROM BRIDGE TO MACHINERY SPACE WAS INOPERATIVE, A VIOLATION OF SOLAS 74/78 CHII-1 REG 37 AND REG 50. CORRECT PRIOR TO 03MAR 99.
Condition: Unknown
Due 3 March 1999
Resolved 2 March 1999
Navigation
Issued 4 March 1997 Resolved
Provide proper operation of the echo depth sounder recorder which failed while in the Port of Savannah prior to departure.
Condition: Unknown
Due 4 March 1997
Resolved 5 March 1997
Electrical
Issued 4 March 1997 Resolved
Remove, repair or replace temporary electrical connections and lights to remove the electrical shock hazzards from the following areas: _x001C_ a)lights by steering rams b) port side eng. room workshop area c) cont. pitch propellor purifier pump d) lighting by stern mooring winch
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Navigation
Issued 12 April 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Construction/Loadline
Issued 23 December 1994 Resolved
PROVE THE WATERTIGHT INTEGRITY OF ALL CARGO HATCH COVERS WITH A HOSE TEST AS PER INTERNATIONAL CONVENTION ON LOADLINE LINES AND SOLAS CHII, REG 15 INTHE PRESENCE OF A COAST GUARD INSPECTOR PRIOR TO RETURN TO A U.S. PORT.
Condition: Unknown
Due 29 June 1995
Resolved 29 June 1995
Construction/Loadline
Issued 23 December 1994 Resolved
MAKE PERMANENT REPAIRS TO THE PORT MAIN BALLAST SEA SUCTION PIPING AND VALVE AS PER SOLAS CH II-1, REG 26 PRIOR TO RETURN TO U.S. PORT.
Condition: Unknown
Due 29 June 1995
Resolved 29 June 1995
Construction/Loadline
Issued 23 December 1994 Resolved
MAKE PERMANENT REPAIRS TO ALL PATCHED SECTIONS OF THE BALLAST PIPING UNDERDECK AS PER SOLAS CHII-1, REG 21 PRIOR TO RETURN TO A U.S. PORT.
Condition: Unknown
Due 29 June 1995
Resolved 29 June 1995
Deck/Cargo
Issued 23 December 1994 Resolved
MAKE PERMANENT REPAIRS TO ALL FRACTURES IN ALL CARGO HOLDS AS PER INTERNATIONAL CONVENTION ON LOADLINES AND SOLAS CH I, REG 1 PRIOR TO DEPARTURE.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Construction/Loadline
Issued 23 December 1994 Resolved
MAKE PERMANENT REPAIRS TO ALL WASTED EXPANSION COUPLINGS ON THE BALLAST LINE AS PER SOLAS CHII-1, REG 21 PRIOR TO RETURN TO A U.S. PORT.
Condition: Unknown
Due 29 June 1995
Resolved 29 June 1995
Engineering
Issued 23 December 1994 Resolved
MAKE PERMANENT REPAIRS TO THE BUNKER TANK IN THE WAY OF THE CEMENT BOX PATCHES IN THE CARGO MACHINERY SPACE AS PER SOLAS CH II-2 PRIOR TO RETURN TO A U.S. PORT.
Condition: Unknown
Due 29 June 1995
Resolved 29 June 1995
Construction/Loadline
Issued 23 December 1994 Resolved
MAKE ALL LEAKING BALLAST MANHOLE COVERS WATERTIGHT AS PER SOLAS CHII-1, REG21 PRIOR TO DEPARTURE.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Construction/Loadline
Issued 23 December 1994 Resolved
PROVE PROPER OPERATION OF STARBOARD BILGE SYSTEM IN WAY OF CARGO MACHINERY SPACE AS PER SOLAS CH II-2, REG 21(1.1) PRIOR TO DEPARTURE.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Lifesaving
Issued 23 December 1994 Resolved
MAKE PERMANENT REPAIRS TO THE LEAKING AIR LINES IN THE CARGO MACHINERY SPACE AS PER SOLAS CH II-1, REG 21 PRIOR TO DEPARTURE.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Lifesaving
Issued 14 August 1994 Resolved
Stbd davit-repair limit switch.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Navigation
Issued 14 August 1994 Resolved
The Subj Vsl's Arpa was inoperative upon arrival to the Port of Tampa.
Condition: Unknown
Due 15 August 1994
Resolved 23 August 1994
Fire Fighting
Issued 14 August 1994 Resolved
Renew/provide fire hoses where needed throughout the vessel.
Condition: Unknown
Due 14 August 1994
Resolved 23 August 1994
Lifesaving
Issued 14 August 1994 Resolved
Remove paint from non-paint locker.
Condition: Unknown
Due 14 August 1994
Resolved 23 August 1994
Construction/Loadline
Issued 14 August 1994 Resolved
Install gasket where missing- cargo access hatch.
Condition: Unknown
Due 14 August 1994
Resolved 23 August 1994
Lifesaving
Issued 14 August 1994 Resolved
Port Aft Davit-Lifeboat Renew 3 worn sheaves.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Accommodation/Occupational Safety
Issued 4 May 1986 Resolved
VSL'S MSD DID NOT HAVE IDENTIFICATION PLACARD AS REQUIRED BY 33 CFR 159.55.
Condition: Unknown
Due 27 January 1993
Resolved 27 January 1993
Navigation
Issued 13 September 1985 Resolved
A VIO OF 33 CFR 164.30 IN THAT A SET OF U.S. CHARTS, OR THEIR EQUIVALENTS, OF THE AREA TRANSITED THAT WERE CURRENTLY CORRECTED, AS REQ BY 33 CFR 164. 33(A)(1)(II) WERE NOT O/B. THE VSL HAD O/B CHART #12222 DTD 1983 WITH CORRECTIONS STARTING WEEK 11-1985.
Condition: Unknown
Due 13 September 1985
Resolved 13 September 1985
Navigation
Issued 25 May 1985 Resolved
A VIO OF 33 CFR 164.30 IN THAT A CURRENTLY CORRECTED COPY OF U.S. COAST PILOT, VOL.3, OR ITS EQUIV, AS REQ BY 33 CFR 164.33(A)(2)(I) WAS NOT O/B. THE VSL HAD O/B U.S. COAST PILOT, VOL.3, DTD 1984 WITH NO CORRECTIONS.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Navigation
Issued 25 May 1985 Resolved
A VIO OF 33 CFR 164.30 IN THAT A SET OF U.S. CHARTS, OR THEIR EQUIV, OF THEAREA TRANSITED THAT WERE CURRENTLY CORRECTED, AS REQ BY 33 CFR 164.33(A)(1)(II) WERE NOT O/B. THE VSL HAD O/B CHART #12221 DTD 1984 WITH NO CORRECTIONS.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985

Ownership record