MAURY USCG vessel records Sign in
← All vessels

TOBA

TOBA is a 1979 freight ship. The Coast Guard has recorded 59 inspections since 1985, most recently in May 2008, along with 29 deficiencies and 1 operational control.

Records from 1985 to 2008. Most recent: inspection, 31 May 2008.

Built
1979
Last inspected
31 May 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7705972 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V6485
228327
Flag
SINGAPORE
—
Maury page id
psix-228327

Inspections, by type

…with no type recorded46
Years with a record 22 calendar years (1985–2008)
The 59 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it32015 - Dead Weight, Ton
53916 - Displacement, Ton
21631 - Regulatory (Subpart C or D), Net Ton
21631 - Convention (Subpart B), Net Ton
39535 - Regulatory (Subpart C or D), Gross Ton
54680 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 7

Inspection history · 59

31 May 2008 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3223019
28 May 2008 PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3220021
5 May 2008 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3199172
4 May 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3198654
19 February 2008 ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3149571
4 December 2007 Random ISPS/MTSA/PSC
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3109790
4 December 2007 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3121750
29 November 2007 ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3106373
29 April 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2918041
12 April 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2906183
23 February 2007 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2876695
23 February 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2950019
2 March 2006 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2594648
25 January 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2573150
11 September 2005 ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2489383
5 July 2005 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2415557
21 August 2004 ISPS II Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2171977
26 April 2004 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2052699
11 December 2001 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 296224
26 October 2000 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 283422
27 June 2000 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 92432
26 August 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 432186
29 January 1999 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 488972
26 November 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 423172
25 October 1997 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 409303
9 February 1997 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 400278
8 February 1997 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 144700
30 August 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 394973
29 April 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 669350
27 April 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 390571
9 April 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 389976
25 July 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 380907
12 March 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 376069
14 December 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 11054
25 October 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 371692
25 October 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1173912
12 June 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 367641
29 January 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 471488
25 January 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 364005
14 June 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 358865
12 June 1993 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 358924
15 December 1992 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 474855
1 December 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 354861
11 December 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 532672
27 June 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 344597
3 November 1990 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 470833
29 April 1990 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 336831
11 December 1989 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 442579
2 May 1989 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 330309
8 November 1988 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 482396
7 June 1988 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 323815
27 October 1987 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 479050
29 April 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 315759
25 November 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 446763
30 April 1986 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 307964
3 October 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 452829
2 April 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 301185
22 March 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1288397
4 March 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 539458

Deficiency record · 29

Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 28 May 2008 Resolved
Steam observed leaking from the blend oil heater outlet pipe located in the fuel oil purifier room. Vessel's crew had removed pipe and found hole in pipe which caused steam leakage. Repair pipe to the satisfaction of vessel's classification society prior to next U.S. port.
Action required: 15 - Rectify deficiencies by next port
Resolved 31 May 2008
Engineering › Lubricating Oil Storage/Transfer System › Flange
Issued 28 May 2008 Resolved
Intermediate fuel oil (IFO) purifier leaked fuel oil that covered various areas, including piping lagging, in the vicinity of the IFO purifier creating a hazardous condition. Cause of leakage suspected to bad seal inside purifier chamber. Repairs to be made to the satisfaction of vessel's classification society prior to next U.S. port.
Action required: 15 - Rectify deficiencies by next port
Resolved 31 May 2008
Engineering › Bilge Water Management System › Piping
Issued 28 May 2008 Resolved
Anchor wash piping leading to both port and starboard anchor hawses have several soft patches in various locations. Make permanent repairs to the satisfaction of the vessel's classification society prior to next U.S. port after sailing foreign. Vessel scheduled to go into drydock in September 2008.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 May 2008
Engineering › Freshwater System (air cooling) › Power Supply
Issued 28 May 2008 Resolved
Portable ducting rigged from fixed ventilation system to fresh water and refrigeration pump motors to prevent overheating. Verify adequacy of arrangement and proper functioning of pump motors to the satisfaction of vessel's classification society prior to next U.S. port after sailing foreign. Vessel scheduled to go into dry dock in September 2008.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 May 2008
Electrical › Electric Generation Source (emergency) › Generator
Issued 5 May 2008 Resolved
Emergency generator is unable to be started using either the electrical starting system or hydraulic starting system. SOLAS 60 Ch2 Reg 26
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2008
Resolution: Received class report attesting to the sat repair and testing of electrical starting system. Reissued form b for repair of hydraulic starting system repair.
Electrical › Electric Generation Source (emergency) › Generator
Issued 5 May 2008 Resolved
Emergency generator secondary means of starting (hydraulic system) does not operate
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 May 2008
Resolution: Received report from [name withheld] attesting to the overhaul and repair of the hydraulic starter system for the emergency generator.
Lifesaving › Launching Appliances › Davit
Issued 5 December 2007 Resolved
Portside lifeboat davit failed to lower during abandon ship drill. Davit is frozen in place. Class to attest to proper operation. SOLAS 74 III/20.7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2007
Resolution: Received class report clearing the above issued deficiency.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 5 December 2007 Resolved
13 battery operated lifejacket lights are inoperable on port side lifejacket locker. 7 dull lifejacket lights an starboard side. Class to attest to proper operation. SOLAS 74 III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2007
Resolution: Received class report clearing the above issued deficiency.
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 4 December 2007 Resolved
Two EEBDs found not ready for use. Class to attest to readiness of vessel's EEBDs. SOLAS 74 II-2/14.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2007
Resolution: Received class report clearing the above issued deficiency.
Construction/Loadline › Structures › Door
Issued 4 December 2007 Resolved
Three fire doors do not close properly. Repairs to be made to the satisfaction of class. SOLAS 74 II-2/14.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2007
Resolution: Received class report clearing the above issued deficiency.
Engineering › Steam System (auxiliary) › Valve
Issued 4 December 2007 Resolved
Steam valve on inboard side of boiler flat leaking and creating a hazard to crew. Class to attest to proper operation. SOLAS 74 I/II
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2007
Resolution: Received class report clearing the above issued deficiency.
Engineering › Steering Gear System › Rudder
Issued 4 December 2007 Resolved
In NFU mode, rudder can only move to 30 degrees starboard on pump two, and 32 degrees starboard with two pumps running. Class to attest to proper operation. SOLAS 60 II/29. Received class report dated 20DEC07 imposing condition of class due Feb 2008.
Action required: 705 - Other - as specified
Due 29 February 2008
Resolved 21 January 2008
Resolution: Received adequate class survey reports attesting to the proper operation.
Fire Fighting › Combustible Materials › Insulation
Issued 4 December 2007 Resolved
Oil soaked lagging found in several places in engine room. Repairs to the satisfaction of class. SOLAS 74 I/II
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2007
Resolution: Received class report clearing the above issued deficiency.
Engineering › Sea-water System (primary cooling) › Pump
Issued 4 December 2007 Resolved
Nozzle cooling pump on #3 generator is removed. Class to attest to integrity of temporary repair. SOLAS 74 I/II
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2007
Resolution: Received class report clearing the above issued deficiency.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Block
Issued 4 December 2007 Resolved
Class to attest to mitigation of fire hazards from oil leaks in containment areas throughout engine room. SOLAS 74 I/II
Action required: 15 - Rectify deficiencies by next port
Resolved 8 December 2007
Resolution: Received class report attesting to all oil and fuel leaks cleaned and found satisfactory.
Engineering › Bilge Water Management System › Piping
Issued 4 December 2007 Resolved
Class to attest to proper bilge drainage from starboard side generator room to allow drainage of accumulated oil from space and prevent oil accumulation currently existing in baffles of engine room on starboard side. SOLAS 74 I/II
Action required: 15 - Rectify deficiencies by next port
Resolved 8 December 2007
Resolution: Received class report attesting to bilge drainage from stbd generator room cleared and tested satisfactory.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 4 December 2007 Resolved
Class to attest to proper operation of emergency fire pump. Pump did not start initially Crew eventually started pump by rigging a spare battery with jumper cables. SOLAS 74 II-2/14.2.1.2
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 6 December 2007
Resolution: Emergency fire pump tested by class with satisfactory results.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 December 2007 Resolved
Class to attest to satisfactory condition of railing, upper catwalk in engine room (forward). SOLAS 74 I/II
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 28 December 2007
Resolution: Received class report dated 20DEC07 attesting to sat repair of railing.
Engineering › Sea-water System (primary cooling) › Valve
Issued 4 December 2007 Resolved
Sea water suction valves found leaking on lower level of engine room, starboard side. SOLAS 74 I/II
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 28 December 2007
Resolution: Received class report dated 20DEC07 attesting to sat operation of seawater suction valves.
Engineering › Fuel Oil Service System › Pump
Issued 4 December 2007 Resolved
Class to attest to proper operation of air cond refer cooling pump (starboard side engine room, lower level) and F/O transfer pump (engine room lower level, forward, starboard of center). SOLAS 74 I/II
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 28 December 2007
Resolution: Received class report dated 20DEC07 attesting to proper operation of pumps.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 4 December 2007 Resolved
Class to attest to suitability of various gauge/electrical connections in engine room which have temp repairs. SOLAS 74 I/II
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 28 December 2007
Resolution: Received class report dated 20DEC07 attesting to suitability of gauges.
Accommodation/Occupational Safety › Messroom › Location
Issued 4 December 2007 Resolved
Alarm bell in galley is inoperable. SOLAS 74 II/2/PART E
Action required: 705 - Other - as specified
Due 11 December 2007
Resolved 6 December 2007
Resolution: Received class report clearing the above issued deficiency.
Fire Fighting › Firemans Outfit › Boots
Issued 4 December 2007 Resolved
Inner boot for one set of fire suit boots is wasted. SOLAS II-2/PART E
Action required: 705 - Other - as specified
Due 11 December 2007
Resolved 8 December 2007
Resolution: Received class report attesting to all four sets of fire outfit boots found satisfactory - 2 pair of boots renewed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 December 2007 Resolved
Class to attest to suitability of exhaust manifold and main prop lagging. SOLAS 74 I/II. Received class report dated 20DEC07 imposing condition of class due Feb 2008.
Action required: 705 - Other - as specified
Due 29 February 2008
Resolved 21 January 2008
Resolution: Received adequate class reports attesting to the suitability of the exhaust manifold and lagging.
Electrical
Issued 26 October 2000 Resolved
Vessel did not have non-conductive matting around main electrical switchboards in the main engine room control space. SOLAS II/27(a)
Condition: Unknown
Due 18 December 2000
Resolved 18 December 2000
Documentation
Issued 9 April 1996 Resolved
COMMODITIES LISTED ON THE VESSELS D.C.M. WERE MISSING PACKING GROUP DESIGNATIONS. THE VESSEL'S AGENT OR CREW IS REQUIRED TO CORRECT PRIOR TO DISCHARGE OF ITS CARGO BOUND FOR THE FOLLOWING U.S. PORTS: NEW YORK, SAVANNAH, MOBILE, MIAMI, AND NEW ORLEANS.
Condition: Unknown
Due 27 April 1996
Resolved 27 April 1996
Documentation
Issued 9 April 1996 Resolved
THE VESSEL'S VEHICLE CARGO WAS NOT BEING SHIPPED ACCORDING TO 49CFR176.30 OR 49CFR176.905(a), THE VEHICLES WERE BEING SHIPPED AS ORM-C. THE VESSELS AGENT OR CREW MUST CORRECT PRIOR TO DISCHARGE OF CARGO BOUND FOR THE FOLLOWING U.S. PORTS: NEW YORK, SAVANNAH, MOBILE, MIAMI, AND NEW OLEANS.
Condition: Unknown
Due 27 April 1996
Resolved 27 April 1996
Documentation
Issued 9 April 1996 Resolved
ALL OF THE LISTED 24-HOUR EMERGENCY RESPONSE TELEPHONE NUMBERS ON THE DANGEROUS CARGO MANIFEST WERE INVALID. THE VESSEL'S AGENT OR CREW IS REQUIRED TO SECURE VALID NUMBERS PRIOR TO DISCHARGE OF CARGO BOUND FOR THE FOLLOWING U.S. PORTS: NEW YORK, SAVANNAH, MOBILE, MIAMI, AND NEW ORLEANS.
Condition: Unknown
Due 27 April 1996
Resolved 27 April 1996
Navigation
Issued 12 June 1993 Resolved
A VIO OF 33 CFR 164.30 IN THAT B.A. CHARTS 2813,2814,2919 USED BY THE VESSEL , WERE NOT CORRECTED TO ADMIRALITY NTM# 1641. WHICH WAS RESONABLY AVAILABLE AND CONTAINED CORRECTIONS NEEDED TO TRANSIT THE AREA FROM VA CAPES TO NORFOLK REACH.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.