MAURY USCG vessel records Sign in
← All vessels

SEA VENTURE

SEA VENTURE is a 1972 tank ship. The Coast Guard has recorded 255 inspections since 1983, most recently in February 2009, along with 261 deficiencies, 10 operational controls and 6 casualty investigations between 2003 and 2008.

Records from 1983 to 2009. Most recent: inspection, 27 February 2009.

Built
1972
Last inspected
27 February 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7203687 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228664
Flag
UNITED STATES
366372000 (licence lapsed)
Maury page id
psix-228664

Inspections, by type

…with no type recorded137
Years with a record 27 calendar years (1983–2009)
The 255 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it8115 - Regulatory (Subpart C or D), Net Ton
19228 - Dead Weight, Ton
5932 - Convention (Subpart B), Net Ton
9993 - Regulatory (Subpart C or D), Gross Ton
10868 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WJMVMMSI 366372000 · cancelled · compulsorily equipped · granted 30 September 2006, cancelled 8 August 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 8

Inspection history · 255

27 February 2009 Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3425348
4 December 2008 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3374759
10 October 2008 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3342002
2 October 2008 Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3337035
21 August 2008 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3304563
21 August 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3304894
18 August 2008 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3302819
24 July 2008 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3277499
10 July 2008 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3264231
18 June 2008 Deficiency Check · Annual Inspection · Examination of Repairs · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3240407
20 May 2008 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3211635
18 May 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3212511
28 April 2008 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3194097
24 April 2008 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3191041
13 March 2008 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3164683
23 February 2008 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3152549
28 January 2008 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3137701
30 May 2007 Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2946133
15 May 2007 MARPOL Annex II Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2930801
4 May 2007 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2922338
3 May 2007 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2921264
30 April 2007 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2919045
17 April 2007 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2909642
6 March 2007 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2882908
5 March 2007 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2882819
11 September 2006 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2775872
11 September 2006 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2806948
10 August 2006 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2743299
28 March 2006 MTSA Verification · Cargo Tank Internal · Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2617648
14 February 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2584695
28 November 2005 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2541674
16 July 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2444214
27 June 2005 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2404584
20 May 2005 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2361115
11 April 2005 MTSA Verification · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2332477
7 April 2005 Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2323757
30 March 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2322832
24 March 2005 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2318446
25 January 2005 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2280683
25 January 2005 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2280685
9 December 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2256237
23 August 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2200001
17 August 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2168468
17 August 2004 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2168502
19 July 2004 MTSA Verification · Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2124780
2 July 2004 Deficiency Check
Physical examination · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 2118599
5 February 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2002076
4 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1959331
29 November 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1958325
11 November 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1955947
11 November 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1965534
3 October 2003 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1942947
19 September 2003 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1908393
29 August 2003 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1890960
29 July 2003 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1860757
16 July 2003 Deficiency Check · Periodic Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1846803
16 June 2003 In-Service Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1818918
3 June 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1814160
28 May 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1803962
5 May 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1789976
17 December 2002 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1720130
12 November 2002 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1732987
17 September 2002 Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1676620
12 August 2002 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1660452
20 May 2002 Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1616507
8 April 2002 Periodic Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1599974
14 January 2002 Deficiency Check · Damage Survey
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1478206
6 December 2001 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1076960
1 October 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1073838
21 September 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1075445
10 September 2001 Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1362434
28 August 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 45384
8 August 2001 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1473108
27 July 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 292563
27 July 2001 Deficiency Check · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1462972
8 May 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1063711
12 March 2001 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1060328
16 January 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 109756
26 September 2000 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1386907
18 August 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 18470
1 June 2000 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 818671
17 May 2000 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1432331
1 March 2000 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 275217
27 December 1999 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 273462
28 September 1999 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 16272
13 September 1999 Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1120021
8 September 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 33926
7 August 1999 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1399161
4 July 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 449909
10 June 1999 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1369230
5 January 1999 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 531451
9 November 1998 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 803439
9 October 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 533973
21 September 1998 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 798956
9 September 1998 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 804588
13 August 1998 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1440045
24 July 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1129860
10 July 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 793768
6 July 1998 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1128190
14 June 1998 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1127147
2 June 1998 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1400789
1 June 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1130123
18 May 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 416030
8 May 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 790397
9 April 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1394935
31 March 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 809247
26 March 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 34098
2 March 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 61065
2 March 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 413393
6 November 1997 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1118745
23 October 1997 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 174276
6 September 1997 Deficiency Check · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1464702
11 July 1997 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 780622
14 June 1997 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 224618
9 May 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 454615
1 April 1997 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1100395
12 September 1996 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 486104
20 June 1996 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1087484
6 June 1996 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1367881
26 April 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1374587
22 April 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1083268
16 March 1996 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 470884
22 November 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 85068
20 October 1995 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 461231
6 October 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 185012
11 September 1995 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1357348
19 July 1995 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1188209
21 June 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1189524
28 April 1995 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 864444
27 April 1995 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 871580
10 April 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 447413
9 February 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 375126
9 February 1995 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 838916
19 January 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 528769
4 January 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 121019
27 December 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 373654
27 December 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 849289
22 September 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 370635
22 September 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1174334
6 September 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 657378
3 September 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 504366
24 August 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 369821
22 August 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 32614
22 August 1994 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1181601
16 August 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 648367
11 August 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1179520
25 July 1994 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1175888
24 July 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 19454
24 July 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 368667
11 July 1994 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1405572
13 June 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1331946
25 May 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 516043
19 April 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 175707
17 April 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1167415
9 April 1994 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 44300
25 February 1994 Damage Survey
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 853252
19 February 1994 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1165260
16 February 1994 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 134784
15 November 1993 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 468074
13 November 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 847457
30 July 1993 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1154947
29 July 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1157285
21 July 1993 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 849983
7 July 1993 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1154498
29 June 1993 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 845319
30 March 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 357133
7 March 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 156063
7 January 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 833980
15 December 1992 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1143088
29 October 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1362655
13 October 1992 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1257269
2 October 1992 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 220601
8 September 1992 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 942436
2 September 1992 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 960059
19 August 1992 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1252758
18 August 1992 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 953064
10 August 1992 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1354192
5 August 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 648368
31 July 1992 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 947992
28 July 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 127301
16 July 1992 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 514375
10 June 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 944621
6 April 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 92175
13 March 1992 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1260118
16 November 1991 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 491947
24 October 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 657379
18 September 1991 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1253971
14 September 1991 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1249608
12 July 1991 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 935389
5 May 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 905434
2 May 1991 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 514535
7 April 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 903463
13 February 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 341863
2 January 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 925218
13 November 1990 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 932490
5 November 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1216240
11 October 1990 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 469775
2 October 1990 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 905736
29 September 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 919997
4 September 1990 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 925452
4 September 1990 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1254703
23 March 1990 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1227587
18 March 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 485873
15 September 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 452141
4 August 1989 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1212935
14 April 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1036027
1 March 1989 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 521474
18 November 1988 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1196545
11 October 1988 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1197713
30 July 1988 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 497122
22 July 1988 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1344447
18 July 1988 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1031044
3 May 1988 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1037507
18 April 1988 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1041554
4 March 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1027105
22 February 1988 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1023418
12 January 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1011476
6 January 1988 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 536423
8 December 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1308549
6 December 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1308936
23 November 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1026349
17 October 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1016362
23 September 1987 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1007836
15 September 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1003943
20 August 1987 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1003430
20 August 1987 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1338084
2 August 1987 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1030969
25 April 1987 MARPOL Annex II Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1317307
16 April 1987 Type not recorded
No type recorded · Marine Safety Center (MSC) · Activity 1329868
13 April 1987 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 493286
27 March 1987 MARPOL Annex II Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1020265
22 December 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1027454
7 November 1986 Administrative
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1014492
17 October 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 503261
31 July 1986 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1303024
5 April 1986 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 485286
12 February 1986 Examination of Repairs
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1302580
22 January 1986 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 995260
10 January 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1299898
6 January 1986 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1295706
26 December 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1303740
20 October 1985 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 459522
16 October 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1296015
10 October 1985 Examination of Repairs
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 991915
27 August 1985 Credit Drydock
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 987909
7 August 1985 MARPOL Annex I Examination · COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1291269
17 April 1985 Type not recorded
No type recorded · COTP NEW LONDON · USCG Northeast District (CGD-NE) · Activity 476623
16 March 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 979153
2 February 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 537728
5 December 1984 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 976429
16 November 1984 Type not recorded
No type recorded · COTP NEW LONDON · USCG Northeast District (CGD-NE) · Activity 532346
30 October 1984 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 456054
10 January 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 972172
28 November 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 972171
24 September 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1280139

Deficiency record · 261

Stability › Weathertight Integrity › General
Issued 10 July 2008 Resolved
Repair or replace weathertight doors on main deck opening into fo'c'sle and entering into steering flat.
Action required: 705 - Other - as specified
Due 27 August 2008
Resolved 26 August 2008
Resolution: see activity number 3304563
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 27 June 2008 Resolved
Replace wasted deck plates and supports to the catwalks in the upper engine room.
Action required: 705 - Other - as specified
Due 27 August 2008
Resolved 26 August 2008
Resolution: see activity number 3304563
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 27 June 2008 Resolved
Install flange shielding on fuel oil piping in the purifier room.
Action required: 705 - Other - as specified
Due 27 July 2008
Resolved 10 July 2008
Resolution: Vessel installed flange shielding on the fuel oil piping in the purifier room.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Bolts
Issued 27 June 2008 Resolved
Replace wasted hardware on cargo manifold valves.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2008
Resolution: Hardware replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 June 2008 Resolved
Replace wasted u-brackets supporting large conduits under main deck catwalk & replace crossover ramps.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 10 July 2008
Resolution: U-bolts supporting conduits replaced.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Loading Arms
Issued 27 June 2008 Resolved
Replace wasted structural supports to the main deck cargo crane base at next drydock.
Action required: 705 - Other - as specified
Due 24 May 2009
Resolved 10 July 2008
Resolution: Company''s naval arch determined horizontal supports were unneeded. Supports removed.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 27 June 2008 Resolved
Replace wasted cargo tank level alarm junction box connections, located on port side catwalk, amidships.
Action required: 705 - Other - as specified
Due 27 July 2008
Resolved 24 July 2008
Resolution: Replaced and showed proof as required.
Stability › Weathertight Integrity › General
Issued 27 June 2008 Resolved
Repair or replace the following watertight & weathertight doors provide proof of proper closing and sealing. After steering, Stb aft double door, 01 deck aft port door, 02 deck aft stb door, 03 deck EDG room, 03 deck stack room door stb side, 03 deck store room door stb side, main deck fwd dog house, fwd paint locker, fwd emergency gear locker, main deck focsal doors.
Action required: 705 - Other - as specified
Due 27 July 2008
Resolved 10 July 2008
Resolution: Inspected doors, all sat except three. New 835 issued for remaining door.
Fire Fighting › Structural - B Class Divisions › Accommodation Spaces
Issued 27 June 2008 Resolved
Provide means to securing vent to the Class B bulkhead for the unapproved vent that was installed for the ice machine. And make changes to Fire/safety plan.
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 4 December 2008
Resolution: Class A vent/Damper installed in existing penetration of class B BHD.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 27 June 2008 Resolved
Replace existing messroom door with approved Class A fire door.
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 9 October 2008
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 27 June 2008 Resolved
Repair / replace toilet plumbing to allow for adaquate and proper flushing.
Action required: 705 - Other - as specified
Due 27 July 2008
Resolved 10 July 2008
Resolution: Tested toilets on several decks, all repaired sat.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 27 June 2008 Resolved
Repair crack in class A bulkhead located above aft starboard door in the galley.
Action required: 705 - Other - as specified
Due 27 August 2008
Resolved 26 August 2008
Resolution: see activity number 3304563
Deck/Cargo › Ballast › Pumps
Issued 27 June 2008 Resolved
Replace engineroom ballast pump.
Action required: 705 - Other - as specified
Due 27 August 2008
Resolved 26 August 2008
Resolution: see activity number 3304563
Lifesaving › Launching Appliances › Davit
Issued 27 June 2008 Resolved
Repair / replace port lifeboat davit by an authorized repair facility w/ USCG oversight. Vessel to maintain an extra 25 man liferaft while port davit is being repaired.
Action required: 705 - Other - as specified
Due 27 August 2008
Resolved 26 August 2008
Resolution: see activity number 3304563
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 27 June 2008 Resolved
Provide certificate from certified company attesting to a proper bench test (within the last five years) of the boiler relief valves as tags are missing.
Action required: 705 - Other - as specified
Due 27 July 2008
Resolved 24 July 2008
Resolution: Proof provided as required.
Construction/Loadline › Hull › Hull Plating
Issued 27 June 2008 Resolved
Provide permenant repairs (crop & renew as original) to hull located behind / around AC cooling seawater chest. (temp repair (doubler) authorized & installed on 27 Jun)
Action required: 705 - Other - as specified
Due 27 August 2008
Resolved 26 August 2008
Resolution: see activity number 3304563
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 27 June 2008 Resolved
Hydrostatically test all sections of piping where leaking manifold valves are found, due to replacement of wasted hardware. In the presence of a USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2008
Resolution: Tested manifold lines sat, see narrative for further details.
Lifesaving › Launching Appliances › Davit
Issued 27 June 2008 Resolved
Perform a weight test of port lifeboat davit after repairs and reinstallation on board the are complete in the presence of a USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 9 October 2008
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 18 June 2008 Resolved
Replace wasted sanitary pipe in the upper level of engine room, pipe is currently soft patched.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 24 June 2008
Resolution: Pipe was replaced.
Engineering › Sea-water System (primary cooling) › Pump
Issued 18 June 2008 Resolved
Replace / repair the number 2 jacket water pump, pump is cracked.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 27 June 2008
Resolution: Repaired crack in number 2 jacket water pump.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 June 2008 Resolved
Replace missing center safety rail on forward deck catwalk, port side.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 25 June 2008
Resolution: Placed safety chain across opening.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 June 2008 Resolved
Replace missing / broken wire straps on wire bundle, located on portside deck catwalk.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 24 June 2008
Resolution: Replaced wire bundling straps.
Construction/Loadline › Penetrations › Gasket
Issued 18 June 2008 Resolved
Replace WTD gasket material to the Starboard Focsle door.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 27 June 2008
Resolution: rewritten def to combine with item # 15
Stability › Watertight Integrity › Weathertight Enclosure
Issued 18 June 2008 Resolved
Repair knife edge on Starboard focsle WTD.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 27 June 2008
Resolution: Rewritten to combine with item # 15.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 18 June 2008 Resolved
Replace U-brackets on hydraulic piping going to the starboard forward main deck mooring winch.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 22 June 2008
Resolution: Replaced U-brackets.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 18 June 2008 Resolved
Adjust all fire safety doors throughout vessel to allow for proper closing and latching.
Action required: 705 - Other - as specified
Due 24 June 2008
Resolved 22 June 2008
Resolution: All doors operable.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 June 2008 Resolved
Install missing and ensure all wire rungs are secured with metal banding.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 24 June 2008
Resolution: Installed wire rungs.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 June 2008 Resolved
Replace unsupported & wasted junction boxes throughout the vessel.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 27 June 2008
Resolution: Replaced junction boxes.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 18 June 2008 Resolved
Repair / replace damaged or wasted kick pipes and cable penetrations on the weather decks.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 27 June 2008
Resolution: replaced kick pipes.
Fire Fighting › Fire Hydrants › Condition
Issued 18 June 2008 Resolved
Repair / replace leaking valve at fire station no. 16.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 22 June 2008
Resolution: Repaired leaking valve.
Construction/Loadline › Structures › Trunk
Issued 18 June 2008 Resolved
Repair numerous holes located on the starboard side at and around the door entrance to the stack (03 level).
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 25 June 2008
Resolution: Repaired holes in the stack.
Documentation › Markings/Placards › Lifejacket Placard
Issued 18 June 2008 Resolved
Provide lifesaving placarding for all lifesaving appliances / stowage locations through out the vessel.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 24 June 2008
Resolution: Provided lifesaving placarding or stenciling.
Accommodation/Occupational Safety › Ventilation › General
Issued 18 June 2008 Resolved
Repair ventilation louver located in the upper vent for the Emergency Diesel Generator room.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 22 June 2008
Resolution: Repaired vent louver.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 18 June 2008 Resolved
Repair holes in class A bulkhead located in the weight room (IVO phone switch)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2008
Resolution: Repaired holes in bulkhead.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 June 2008 Resolved
Repair / replace inoperable lights in the weight room.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 27 June 2008
Resolution: Installed new light bulbs.
Fire Fighting › Structural - A Class Divisions › Open Deck Spaces
Issued 18 June 2008 Resolved
Repair numerous holes in class A superstructure located around firestation no. 16
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 27 June 2008
Resolution: Repairs made to superstructure.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 18 June 2008 Resolved
Repair holes in Class A bulkhead starboard side around door leading to the boiler flat.
Action required: 705 - Other - as specified
Due 24 June 2008
Resolved 22 June 2008
Resolution: Repaired holes in bulkhead.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 18 June 2008 Resolved
Install insulation to meet Class A-60 fire protection to starboard side bulkhead in boiler flat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2008
Resolution: Provided insulation.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 18 June 2008 Resolved
Repair holes in Class A aft bulkhead to the boiler flat, centerline above CO2 fire extinguisher nozzles.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2008
Resolution: Repaired holes in bulkhead.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 June 2008 Resolved
Remove all deadend wiring throughout the vessel.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 27 June 2008
Resolution: Removed wiring.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 18 June 2008 Resolved
Repair holes in Class A bulkhead in portside machinery space ( holes are located behind the exhaust pipes to the portside boiler flat)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2008
Resolution: Repaired holes in bulkhead.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 18 June 2008 Resolved
Provide proof of door on starboardside leading to boiler room meets Class A-15 requirements.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 27 June 2008
Resolution: Provided fire insulation.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 18 June 2008 Resolved
Repair hole in Class A starboard bulkhead located in the officer lounge aft corner near dumbwaiter.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 27 June 2008
Resolution: Repaired holes.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 June 2008 Resolved
Repair navigation lighting panel, (panel alarm intermitantly alarms for the aft light (light still on & opearable)).
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 18 June 2008
Resolution: Repaired loose wire in pannel. Pannel tested. All sat.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 18 June 2008 Resolved
Replace expired lights on all lifejackts and immersion suits.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2008
Resolution: Replaced all expired lights.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 18 June 2008 Resolved
Conduct an external SMS audit with CG Marine Inspector in attendance.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2008
Resolution: Vessel conducted anSMS audit (see scanned documents)
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 18 June 2008 Resolved
Replace broken Shackle attaching embarkation (Jacobs ladder) for the port lifeboat. Ensure all ladders for lifeboat/life raft embarkation are in serviceable condition.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2008
Resolution: Replaced shackle, ladders in serviceable condition.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 18 June 2008 Resolved
Conduct an abandon ship drill to the satisfaction of USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2008
Resolution: Conducted an abandon ship drill.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 19 May 2008 Resolved
Repair and prove proper operations of steering gear ensuring rudder angle indicators between bridge and steering compartment meet requirements prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2008
Resolution: Vessel repaired the steering gear and completed steering test prior to departure.
Lifesaving › Lifeboat › Hull
Issued 13 March 2008 Resolved
Make proper repairs to the port lifeboat. while repairs are being made a 25 man SOLAS A pack raft shall be onboard in the vicinity of the port lifeboat station. 3/31/08 Extended the requirment due to additonal work being done to the life boat.
Due 30 April 2008
Resolved 28 April 2008
Resolution: Scanned in servicing report.
Lifesaving › Lifeboat › Hull
Issued 13 March 2008 Resolved
Conduct weight test required by 46 CFR 160.035-13(b)(2). 3/31/08 Extended the requirment at owners request due to additional work on the boat.
Due 30 April 2008
Resolved 28 April 2008
Resolution: Scanned in servicing report.
Engineering › Steering Gear System › Motor
Issued 6 March 2007 Resolved
Provide repair to vessel's steering hand hydraulic telemotor system consistent with original system installation. Compression fitting to be replace in kind.
Action required: 705 - Other - as specified
Due 20 March 2007
Resolved 19 March 2007
Resolution: Rcvd email from ABS containing survey report showing acceptance of permanent repair to be as original.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 28 March 2006 Resolved
Show proper operation of overfill devices on #1, #3, and #5 cargo tanks.
Action required: 705 - Other - as specified
Resolved 9 June 2006
Lifesaving › Launching Appliances › Davit
Issued 12 April 2005 Resolved
Conduct general maintenance on both life boat davits.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 20 May 2005
Fire Fighting › Miscellaneous Items › B Class Division Penetrations
Issued 12 April 2005 Resolved
Repair fire dampers for the port main deck forward head. Missing the manual closure handles.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 20 May 2005
Construction/Loadline › Structures › Deck Plating
Issued 12 April 2005 Resolved
Repair crack in overhead of the 03 level A/C space. Allowed temporary repairs until vessels required drydock date in September 2005.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 September 2005
Resolved 20 May 2005
Resolution: Fixed
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 12 April 2005 Resolved
Provide operating instructions for galley fixed firefighting system. Tag to be supplied by fire service company.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 20 May 2005
Electrical › Electrical Distribution System (service) › Switchboard
Issued 12 April 2005 Resolved
Install missing safety rail on main switchboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 20 May 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 12 April 2005 Resolved
Properly secure electrical cable in the escape trunk.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 20 May 2005
Construction/Loadline › Penetrations › Gasket
Issued 12 April 2005 Resolved
Install gaskets and bolts on engine room 03 level aft entrance.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 20 May 2005
Construction/Loadline › Structures › Door
Issued 12 April 2005 Resolved
Conduct maintenance on all weathertight and watertight doors.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 20 May 2005
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 12 April 2005 Resolved
Prior to operating the vessel, provide copy of the vessel's Certificate of Financial Responsibility
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2005
Resolved 13 April 2005
Resolution: Provided.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 12 April 2005 Resolved
Prior to conducting cargo operations, provide proof of an updated VRP.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2005
Resolved 13 April 2005
Resolution: Provided.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 12 April 2005 Resolved
Prior to cargo operations, provide proof of the vessels updated SMPEP.
Action required: 705 - Other - as specified
Due 14 April 2005
Resolved 13 April 2005
Resolution: Provided.
Deck/Cargo › Ballast › Segregated Ballast Tank
Issued 8 April 2005 Resolved
Repair holed area in #2 WP ballas tank.
Due 8 April 2005
Resolved 8 April 2005
Resolution: Satisfactory air test witnessed by ABS Beaumont and accepted by PATMS.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 17 August 2004 Resolved
Vessel lost its port anchor outside of Charleston Harbor outer anchorage and requested a letter of deviation be granted to enter and exit the Port of Charleston.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 17 August 2004
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 17 August 2004 Resolved
Issued LOD for M/T SEA VENTURE. M/T SEA VENTURE is authorized to enter Bolivar Roads Anchorage to install new port anchor, shackle, pear-shaped kantor link, two chain link, one master link, and the lower portion of the swivel. Anchor to be installed and Class fax to attest of proper installation and operation prior to entering port.
Action required: 15 - Rectify deficiencies by next port
Resolved 20 August 2004
Resolution: Port anchor, swivel group and detachable link replaced. Installation was examined, windlass exercised and considered satisfactory (by ABS). Validity of equipment certificate 01-GH14329 and 01-GH15958 confirmed per ABS Hong Kong fax dated 08/20/04
Construction/Loadline › Structures
Issued 29 July 2003 Resolved
Repair by cropping & renewing raised deck around sky-light, 02 level. Crop & renew scupper channel stbd side. Crop & renew Crop & renew guard railing stbd side to the satisfaction of the attending CG inspector. LEGACY COMPONENT DESC: Deck Plating
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 September 2003
Resolved 3 October 2003
Construction/Loadline › Structures
Issued 29 July 2003 Resolved
Replace WTD to the emergency generator space. LEGACY COMPONENT DESC: Door
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 29 August 2003
Resolution: Corrected action according to faxed work order #767 dated 4AUG03. Work done by Gulf Copper Manufacturers ([name withheld]). Work authorized by [name withheld] of Atlantic Tankships, Inc. [phone withheld].
Construction/Loadline › Structures
Issued 29 July 2003 Resolved
Renew king post portside cat-walk and ladder due to excessive wastage. Repair to the satisfaction of the attending CG inspector. LEGACY COMPONENT DESC: Trunk
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 29 August 2003
Resolution: Corrected action according to faxed work order #767 dated 4AUG03. Work done by Gulf Copper Manufacturers ([name withheld]). Work authorized by [name withheld] of Atlantic Tankships, Inc. [phone withheld].
Electrical › Electric Generation Source (emergency)
Issued 16 July 2003 Resolved
Prove proper operation of lube oil pressure shutdown and alarm for emergency generator. LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Due 16 August 2003
Resolved 29 July 2003
Resolution: Repaired to the satisfaction of the attending CG inspector.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 16 July 2003 Resolved
Perform hydrostatic test of cargo piping and hose and label with date prior to bunkering. LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2003
Resolution: Hydrostatic test completed.
Lifesaving › Lifeboat Equipment
Issued 16 July 2003 Resolved
Provide sea-sick pills for both lifeboats. LEGACY COMPONENT DESC: Anti-seasickness Medicine
Condition: Improper/Lack of Maintenance
Due 16 August 2003
Resolved 6 August 2003
Resolution: Recieved fax confirmation of reciept of sea-sick pills for lifeboats.
Construction/Loadline › Structures
Issued 16 July 2003 Resolved
Provide new entry steps to aft port entry to cargo thermal heater room. LEGACY COMPONENT DESC: Ladder
Condition: Improper/Lack of Maintenance
Due 16 August 2003
Resolved 29 July 2003
Resolution: new steps were installed
Construction/Loadline › Structures
Issued 16 July 2003 Resolved
Make repairs or replace the below listed Water Tight Doors: 1. Port and Stbd aft WTD's on 02 deck 2. Port side WTD on 03 deck 3. Main deck Double doors aft Stbd side. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Due 16 September 2003
Resolved 29 August 2003
Resolution: Corrected WTDs as per faxed work order #767 dated 4AUG03 by Atlantic Tankships, Inc. Work was authorized by [name withheld] performed by contractor (Gulf Copper Manufacturers, POC: [name withheld]).
Construction/Loadline › Structures
Issued 16 July 2003 Resolved
Repair by cropping and renewing numerous holes in deck on 02 level (sky-light deck). LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Due 16 August 2003
Resolved 29 July 2003
Resolution: This def is being reissued, due to the excessived wastage below noted below the 02 sky-light.
Construction/Loadline › Structures
Issued 16 July 2003 Resolved
Repair/replace water tight door and crop and renew combing under door area on cargo thermal heating room LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Due 16 September 2003
Resolved 29 August 2003
Resolution: Corrected action according to faxed work order #767 dated 4AUG03. Work done by Gulf Copper Manufacturers ([name withheld]). Work authorized by [name withheld] of Atlantic Tankships, Inc. [phone withheld].
Lifesaving › Immersion Suits
Issued 16 July 2003 Resolved
Provide one (1) additional immersion suit for a total of 29 onboard vessel.
Condition: Improper Installation
Due 16 August 2003
Resolved 16 July 2003
Resolution: Missing immersion suit was located and placed in service.
Construction/Loadline › Hull
Issued 17 September 2002 Resolved
Repair hole in port hawse pipe. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 October 2002
Resolved 28 October 2002
Construction/Loadline › Hull
Issued 17 September 2002 Resolved
Repair inset below port hawse pipe. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 October 2002
Resolved 28 October 2002
Construction/Loadline › Structures
Issued 17 September 2002 Resolved
Repair three pin hole leaks in aft chain locker bulkhead insert welds. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 October 2002
Resolved 18 October 2002
Resolution: Three pin hole leaks were welded. Witnessed satisfactory hydro test.
Construction/Loadline › Structures
Issued 17 September 2002 Resolved
In the double bottom #2AS ballast tank, repair fractured welds on top and bottom of fourth vertical from outboard, fifth bay aft of forward bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 October 2002
Resolved 18 October 2002
Resolution: Inspected weld repair to fractured welds.
Construction/Loadline › Structures
Issued 17 September 2002 Resolved
Replace missing vertical in double bottom #2AS ballast tank, sixth bay aft of forward bulkhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 October 2002
Resolved 18 October 2002
Resolution: Inspected installation of missing vertical.
Deck/Cargo › Holds/Tanks
Issued 17 September 2002 Resolved
Cargo tank 1FS, re-cap weld around existing insert on forward bulkhead, upper level. LEGACY COMPONENT DESC: Bulkhead
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 October 2002
Resolved 15 October 2002
Resolution: Inspected satisfactory weld re-cap.
Deck/Cargo › Holds/Tanks
Issued 17 September 2002 Resolved
Cargo tank 3AP, grind weld around existing insert on forward bulkhead, bottom level. LEGACY COMPONENT DESC: Bulkhead
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 October 2002
Resolved 15 October 2002
Resolution: Inspected ground weld around insert.
Deck/Cargo › Holds/Tanks
Issued 17 September 2002 Resolved
Cargo tank 3AS, weld the three 2-inch fractures in the upper level deck, forward, inboard side.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 October 2002
Resolved 15 October 2002
Resolution: Inspected satisfactory weld repairs to fractures.
Deck/Cargo › Holds/Tanks
Issued 17 September 2002 Resolved
Cargo tank 5S, weld three 2-inch fractures in upper level deck, forward, inboard side.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 October 2002
Resolved 15 October 2002
Resolution: Inspected satisfactory weld repairs to fractures.
Fire Fighting › Fire Main
Issued 8 April 2002 Resolved
Renew waste firemain support brackes on the stbd side, main deck house. Repair door at NR 4 fire station. Renew wasted 21/2" pipe at NR 6 fire station. Install U-bolt on fire main above tank 5 FC. Repair holed fire main at NR 1 fire station at deck flange. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2002
Fire Fighting › Fire Main › Condition
Issued 8 April 2002 Resolved
Properly repair leaks in fire main system at fire station NR 10 and on the 02 deck next to the stack.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2002
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 8 April 2002 Resolved
Repair high level & overfill alarm for #1 center cargo tank.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2002
Construction/Loadline › Structures › Door
Issued 8 April 2002 Resolved
Repair wasted knife edge on hatch located on foc'sl. Repair paint locker watertight door. Repair aft steering escape WTD.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2002
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 8 April 2002 Resolved
Repair WTD coaming at SCBA locker. Repair cracked bulkhead at SCBA locker.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 April 2002
Lifesaving › Liferaft Equipment
Issued 8 April 2002 Resolved
Install 20 man and 10 man liferafts in proper location or restencil.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2002
Lifesaving › Launching Appliances › Davit
Issued 8 April 2002 Resolved
STBD DAVITS: Replace aft bracing (puddin), replace aft tricing pendant, make bottom end of fwd tricing pendant safe for use (hand hold), install missing nut on bolt for horizontal (upper) support bracing. PORT DAVITS: replace shackle for tricing pendant, install aft bracing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2002
Lifesaving › Immersion Suits
Issued 8 April 2002 Resolved
Provide 29 immersion suites as per COI. 04 suits are missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 April 2002
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 8 April 2002 Resolved
Replace 06 lifejackets marked by marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2002
Fire Fighting › Fire Hoses › Material
Issued 8 April 2002 Resolved
Replace all 1 1/2" fire hoses with UL approved hoses.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2002
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 8 April 2002 Resolved
Properly wire fan in Pilot S/R.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 April 2002
Electrical › Electrical Distribution System (service) › Panelboard
Issued 8 April 2002 Resolved
Replace panel on shore connection box in A/C room.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 22 April 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 8 April 2002 Resolved
Remove and properly stow all combustable material in the Deck "Gold" locker and Foc'sl work locker.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 April 2002
Electrical › Electric Generation Source (service)
Issued 8 April 2002 Resolved
Replace cracked #3 generator jacket water out to heat exchanger hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 April 2002
Electrical › Electric Supply System (service) › Cable
Issued 8 April 2002 Resolved
Secure vertical wire run support to mount on hydraulic tank for seering system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 April 2002
Engineering › Steering Gear System
Issued 8 April 2002 Resolved
Repair steering system limit switches.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2002
Deck/Cargo › Cargo Stowage
Issued 8 April 2002 Resolved
Properly lablel deck mounted diesel tanks. LEGACY COMPONENT DESC: Deck Mounted Diesel Tank
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 April 2002
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 8 April 2002 Resolved
Repair handhold for port side ladder, on the bulkhead side, at the top of the ladder above the main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 April 2002
Engineering › Pressure Vessel
Issued 8 April 2002 Resolved
Renew/repair relief valve for start air receiver NR. H-275. LEGACY COMPONENT DESC: Relief Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2002
Resolved 20 May 2002
Resolution: New safety relief valve installed and calibrated. Witnessed satisfactory test - Lift 400 psi, Shut 360 psi
Engineering
Issued 8 April 2002 Resolved
Repair remote fuel stops for mixing tank, stbd bunker low suction, and generator. LEGACY COMPONENT DESC: Remote Fuel Stops
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 April 2002
Engineering
Issued 8 April 2002 Resolved
Repair fuel leak at clean diesel remote stop valve bonnet. LEGACY COMPONENT DESC: Diesel Remote Stop Valve Bonnet.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 April 2002
Electrical › Electric Supply System (service)
Issued 8 April 2002 Resolved
Repair/replace cracked conduit runs into the cargo pump on/off switch for #3 FP. LEGACY COMPONENT DESC: Cargo Pump Conduit
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2002
Engineering
Issued 8 April 2002 Resolved
Eliminate exhaust enetering into emergency generator room during operation. LEGACY COMPONENT DESC: Emergency Generator
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 April 2002
Electrical › Electric Generation Source (emergency)
Issued 8 April 2002 Resolved
Renew/repair vent pipe used for emergency battery room. LEGACY COMPONENT DESC: Emergency Battery Room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2002
Resolved 20 May 2002
Resolution: Pipe replaced in kind.
Construction/Loadline › Hull
Issued 14 January 2002 Resolved
MAKE PERMANENT REPAIRS TO WASTED HULL PLATING IN DOUBLE BOTTOM BALLAST TANK 2FC IWO AREA UNDER TANK FILL PIPE AT NEXT VESSEL DRYDOCK. REPAIRS TO BE COMPLETED TO SATISFACTION OF ATTENDING COAST GUARD MARINE INSPECTOR LEGACY COMPONENT DESC: Bottom Plating
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 30 October 2002
Electrical
Issued 27 July 2001 Resolved
Secure with screws CO2 junction box at ladder way to reefer space.
Condition: Unknown
Due 27 August 2001
Resolved 3 August 2001
Electrical
Issued 27 July 2001 Resolved
Provide blank plate for 440V galley panel.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Engineering
Issued 27 July 2001 Resolved
Re-route stbd stack vent dampner cable.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Engineering
Issued 27 July 2001 Resolved
Perform boiler mounts inspection on auxiliary and clayton boilers in the presence of a uscg marine inspector.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Fire Fighting
Issued 27 July 2001 Resolved
Provide a 60 second time delay for engine room CO2 system.
Condition: Unknown
Due 31 July 2001
Resolved 3 August 2001
Electrical
Issued 27 July 2001 Resolved
Properly mount servo-motor for #3 SSDG.
Condition: Unknown
Due 27 August 2001
Resolved 3 August 2001
Electrical
Issued 27 July 2001 Resolved
Insulate servo-motor wiring for #3SSDG.
Condition: Unknown
Due 27 August 2001
Resolved 3 August 2001
Unknown
Issued 27 July 2001 Resolved
MAKE PERMANENT REPAIR IWO JUBILEE PATCH ON FOC'SLE ON CHAIN WASH LINE, PORTSIDE FWD AND OVERHEAD OF SWITCHBOARD. INSTALL APPROPRIATE PROTECTION FOR SWITCH BOX FROM WATER FROM PIPING.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Lifesaving
Issued 27 July 2001 Resolved
REAPPLY RETRO REFLECTIVE TAPE TO RING BUOYS AND GRAB LINE ON BRIDGE WING BUOY.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Electrical
Issued 27 July 2001 Resolved
Properly terminate wiring at pump controller.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Construction/Loadline
Issued 27 July 2001 Resolved
Scale and preserve upper area crop and renew as needed in emergency escape hatch coaming.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Engineering
Issued 27 July 2001 Resolved
Re-install cover on aux. boiler control cabinet.
Condition: Unknown
Due 27 August 2001
Resolved 3 August 2001
Electrical
Issued 27 July 2001 Resolved
Repair or install a new lighting fixture in the emergency escape from shaftalley
Condition: Unknown
Due 27 August 2001
Resolved 3 August 2001
Engineering
Issued 27 July 2001 Resolved
Re-run remote pull cable for dirty oil tank.
Condition: Unknown
Due 27 August 2001
Resolved 3 August 2001
Deck/Cargo
Issued 27 July 2001 Resolved
ENSURE PROPER SETTING OF #4C PRESSURE RELIEF VELOCITY STACK
Condition: Unknown
Due 28 July 2001
Resolved 9 August 2001
Deck/Cargo
Issued 27 July 2001 Resolved
MAKE PERMANENT REPAIR TO VACUUM RELIEF VALVE HOUSING #19 IWO #6 PORT CARGO TANK. (HOUSING HOLED).
Condition: Unknown
Due 28 July 2001
Resolved 9 August 2001
Fire Fighting
Issued 27 July 2001 Resolved
REPAIR CONTROL LINKAGE FOR AFT-MOST FIRE MONITOR'S FLAPS.
Condition: Unknown
Due 28 July 2001
Resolved 9 August 2001
Construction/Loadline
Issued 27 July 2001 Resolved
MAKE PERMANENT REPAIRS TO HOLED BALLAST LINE, STBD SIDE FWD TWO #2 CARGO TANK.
Condition: Unknown
Due 27 August 2001
Resolved 27 August 2001
Lifesaving
Issued 27 July 2001 Resolved
PROVIDE DRAINAGE FOR FWD LOOKOUT'S PFD STORAGE BOX ON FOC'SLE.
Condition: Unknown
Due 28 July 2001
Resolved 9 August 2001
Lifesaving
Issued 27 July 2001 Resolved
Stencil G.Q.(General Quarter) bell (2) _x001C_ "WHEN ALARM SOUNDS GO TO STATIONS"_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 August 2001
Resolved 3 August 2001
Electrical
Issued 27 July 2001 Resolved
Properly support new control wiring.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Construction/Loadline
Issued 27 July 2001 Resolved
Free-up linkage shaft alley water tight door.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Engineering
Issued 27 July 2001 Resolved
Proper test and tag safety valves for #1 and #2 S/S starting air tanks.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Fire Fighting
Issued 27 July 2001 Resolved
Install safety instructions for CO2 system, for emergency SSDG.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Deck/Cargo
Issued 26 September 2000 Resolved
SUBMIT PLANS/DRAWINGS FOR USE OF FLEXIBLE HOSE WITH TSBD SLOP TANK OR INSTALL AS PREVIOUSLY APPROVED. SUBMIT PLANS/DRAWINGS TO CG MARINE SAFETY CENTER. ONCE INSTALLED MAKE STBD SLOP TANK AND PIPING AVAILABLE FOR EXAMINATION AND TESTING BY COGNIZANT CG OCMI.
Condition: Unknown
Due 26 September 2000
Resolved 26 September 2000
Engineering
Issued 17 May 2000 Resolved
Prove proper operation of thermal fluid heater safety devices before operation of the same.
Condition: Unknown
Due 17 June 2000
Resolved 5 June 2000
Electrical
Issued 17 May 2000 Resolved
Renew missing guard on #1 ship service diesel generator fresh water pump drive shaft.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Lifesaving
Issued 17 May 2000 Resolved
Conduct 100% weight test on stbd lifeboat to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 17 June 2000
Resolved 25 May 2000
Construction/Loadline
Issued 7 August 1999 Resolved
Repair hole in hull stbd side shaft alley IVO Fr 14 & 15 IWO cement patch and perform to satisfaction of attending class surveyor or Coast Guard Marine Inspector NLT next scheduled dry dock exam._x001C_ _x001C_
Condition: Unknown
Due 7 August 1999
Resolved 7 August 1999
Lifesaving
Issued 9 September 1998 Resolved
Prove proper operation of releasing gear on port side lifeboat in the presence of a USCG Marine Inspector, upon completion of making port lifeboat engine compartment watertight.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Lifesaving
Issued 2 June 1998 Resolved
PROVE PROPER OPERATION OF RELEASING GEAR ON PORT LIFEBOAT IN THE PRESENCE OF A USCG MARINE INSPECOR UPON COMPLETION OF MAKING PORT LIFEBOAT ENGINE COMPARTMENT WATERTIGHT ISSUED FROM 09 APRIL 1998 AT THE PORT OF PORT ARTHUR, TX.
Condition: Unknown
Due 2 June 1998
Resolved 2 June 1998
Engineering
Issued 2 June 1998 Resolved
DEMONSTRATE PROPER OPERATION OF STEAM GENERATOR SAFETY INTERLOCKS AND RELEIF VALVES NO LATER THATN 01JUN98.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Lifesaving
Issued 2 June 1998 Resolved
PROVIDE ON BOARD 100% LIFERAFTS AFT FOR TOTAL PERSONS ALLOWED IN ACCORDANCEWITH VESSELS COI (29) AND PROPERLY MOUNTED TO THE SATISFACTION OF ATTENDINGUSCG MARINE INSPECTOR.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Lifesaving
Issued 8 May 1998 Resolved
MAINTAIN 200% LIFEBOAT PROTECTION PER SIDE WHILE LIFEBOAT(S) ARE OUT FOR REPAIRS.
Condition: Unknown
Due 8 May 1998
Resolved 8 May 1998
Lifesaving
Issued 8 May 1998 Resolved
MAKE REPAIRS TO STBD LIFEBOAT RELEASING GEAR NEAR BOTTOM OF BOAT(WASTAGE)FWD & AFT.
Condition: Unknown
Due 8 May 1998
Resolved 8 May 1998
Lifesaving
Issued 8 May 1998 Resolved
WEIGHT TEST STBD LIFE BOAT UPON COMPLETION OF REPAIRS.
Condition: Unknown
Due 8 May 1998
Resolved 8 May 1998
Lifesaving
Issued 9 April 1998 Resolved
MAKE PORT LIFEBOAT ENG COMPARTMENT WATERTIGHT.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Lifesaving
Issued 9 April 1998 Resolved
REPAIR/REPLACE FWD SKEG ON PORT LIFEBOAT.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Lifesaving
Issued 9 April 1998 Resolved
MAKE REPAIRS TO STBD LIFEBOAT RELEASING GEAR SUPPORTS NEAR BOTTOM OF BOAT, FWD AND AFT. IF BOAT IS REMOVED FOR REPAIRS, MUST PROVIDE 200% LIFEBOAT PROTECTION FOR STBD SIDE. WEIGHT TEST LIFEBOAT UPON REPAIRS.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Engineering
Issued 31 March 1998 Resolved
PROPERLY TEST THE MAIN ENGINE UPON COMPLETION OF MAIN DRIVE GEAR REPLACEMENT (FORWARD/REVERSE). PROVIDE COPIES OF (1) NON-DESTRUCTIVE TESTING OF DRIVE GEARS (2) M.A.N. REPRESENTATIVE'S FINAL REPORT AND (3) LETTER FROM [name withheld] TO SAT TEST OF MAIN ENGINE.
Condition: Unknown
Due 3 April 1998
Resolved 10 December 1998
Navigation
Issued 2 March 1998 Resolved
Gyro repeaters on bridge not operating.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Unknown
Issued 2 March 1998 Resolved
Transfer hoses on deck, not blanked off.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Accommodation/Occupational Safety
Issued 6 September 1997 Resolved
RENEW OR REPAIR DETERIORATED/HOLED MARINE SANITATION DEVICE, INWAY OF TANK AND ASSOCIATED PVC PIPING. SEE 33 CFR 159.7
Condition: Unknown
Due 29 December 1997
Resolved 29 December 1997
Fire Fighting
Issued 11 July 1997 Resolved
PROVE PROPER OPERATION OF TIME DELAY FOR ENGINEROOM CO2 SYSTEM.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Fire Fighting
Issued 11 July 1997 Resolved
REPLACE MAIN ELECTRICAL FEED AND ASSOCIATED CABLES FOR CLAYTON BOILER.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Fire Fighting
Issued 11 July 1997 Resolved
PROVE PROPER OPERATION OF HEAT ACTIVATED DEVICE FOR PAINT LOCKER CO2 SYSTEM.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Construction/Loadline
Issued 6 June 1996 Resolved
REPAIR KNIFE EDGE ON WEATHER TIGHT DOORS; PORT & STBD FWD MAIN DECK, 0-3 LEVEL.
Condition: Unknown
Due 5 August 1996
Resolved 5 August 1996
Deck/Cargo
Issued 6 June 1996 Resolved
VESSEL PERMITTED ONE TIME LOADING OF STYRENE AT FREEPORT, TX TO BEGIN ON ORABOUT 08JUN96. VSL IS REQUIRED TO CONTINUOUSLY MONITOR VCS PRESSURE/VACUUM GAUGE DURING CARGO OPERATION. THEREAFTER, VSL TO PROVE OPERATION OF VCS HI/LO PRESSURE ALARMS TO SATISFACTION OF COGNIZANT OCMI.
Condition: Unknown
Due 5 August 1996
Resolved 5 August 1996
Construction/Loadline
Issued 6 June 1996 Resolved
REPAIR/REPLACE DOOR TO FLUID HEATER COMPARTMENT.
Condition: Unknown
Due 5 August 1996
Resolved 5 August 1996
Fire Fighting
Issued 6 June 1996 Resolved
REPAIR 3 WASTED/FROZEN MANUAL FIRE DAMPERS, MAIN DK, PORT, ADJACENT TO MESS.
Condition: Unknown
Due 5 August 1996
Resolved 5 August 1996
Navigation
Issued 6 June 1996 Resolved
PROVE OPERATION OF PILOT HOUSE CONSOLE EOT POWER FAILURE ALARM.
Condition: Unknown
Due 5 August 1996
Resolved 5 August 1996
Fire Fighting
Issued 19 July 1995 Resolved
INSTALL A CO2 SHUTDOWN FOR THE EMERGENCY DIESEL GENERATOR AS REQUIRED BY 46CFR 112.50.
Condition: Unknown
Due 16 August 1995
Resolved 16 August 1995
Fire Fighting
Issued 19 July 1995 Resolved
REPLACE OR HYDRO TEST THE 15LB CO2 ON THE PORTSIDE OF THE BOAT DECK.
Condition: Unknown
Due 19 July 1995
Resolved 19 July 1995
Deck/Cargo
Issued 25 July 1994 Resolved
PRIOR TO LOADING CARGOES WHICH REQUIRE A QUICK-CLOSING VALVE INTO CARGO TANK 2CF, MAKE PERMANENT REPAIRS TO OVERFLOW QUICK-CLOSING VALVE AND DEMONSTRATE ITS PROPER OPERATION. (VALVE FOR CARGO TANK 2CF WAS NOT OPERATIONAL DURING COI INSPECTION AND DURING 25JUL94 USCG VISIT TO VESSEL.)
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Navigation
Issued 24 July 1994 Resolved
A VIO OF 33 CFR164.33 IN THAT THE U.S. CHART #12312, USED BY THE VESSEL WASNOT THE MOST RECENT EDITION.
Condition: Unknown
Due 25 July 1994
Resolved 29 July 1994
Lifesaving
Issued 11 July 1994 Resolved
INSTALL SAFETY GUARDS BETWEEN GENERATORS AND ENGINE UNITS - 3 EACH._x001C_
Condition: Unknown
Due 11 July 1994
Resolved 11 July 1994
Deck/Cargo
Issued 11 July 1994 Resolved
MAKE PERMANENT REPAIRS TO OVERFLOW QUICK CLOSING VALVE 4C,2CF PRIOR TO LOADING CARGOES REQUIRING THIS ITEM.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Engineering
Issued 11 July 1994 Resolved
REPAIR OR REPLACE AUX BOILER MAIN STEAM STOP VALVE, SURFACE AND BOTTOM BLOW._x001C_
Condition: Unknown
Due 11 July 1994
Resolved 11 July 1994
Electrical
Issued 11 July 1994 Resolved
PROVE OPERATION OF #1 S/S GEN OVERSPEED TRIP INSTALL NEW TACH TO SHOW TRIPPING POINT OR HAND TACH.
Condition: Unknown
Due 11 July 1994
Resolved 11 July 1994
Construction/Loadline
Issued 13 June 1994 Resolved
INSTALL TRIPPING BRACKETS AT FRAMES 30, 31, 32 LOCATED ON CENTERLINE BULKHEAD IN PORT AFT BALLAST TANK IN ACCORDANCE WITH SHIP'S BLUEPRINTS DETAIL 6-A.
Condition: Unknown
Due 13 June 1994
Resolved 13 June 1994
Construction/Loadline
Issued 13 June 1994 Resolved
MAKE PERMANENT REPAIRS TO FRACTURED CENTERLINE BULKHEAD BETWEEN AFT BALLASTTANKS.
Condition: Unknown
Due 13 June 1994
Resolved 13 June 1994
Construction/Loadline
Issued 25 February 1994 Resolved
MAKE PERMANENT REPAIRS IN WAY OF THE BOTTOM FRACTURE AT FRAME 184 IN THE FOREPEAK BALLAST TANK, TO THE SATISFACTION OF THE COGNIZANT [name withheld] NEXT DRYDOCKING. MAINTAIN THE EPOXY AND CEMENT BOX TEMPORARY REPAIR. REPORT ADVERSE FINDINGS FROM ROUTINE SOUNDINGS & CREW INSPECTIONS TO OCMI.
Condition: Unknown
Due 25 February 1994
Resolved 25 February 1994
Construction/Loadline
Issued 19 February 1994 Resolved
AFTER DISCHARGING STYRENE CARGO AT GALES FERRY, CT, PROCEED TO PAULSBORO TOOFFLOAD REMAINING CARGO AND MAKE A MORE EFFECTIVE REPAIR TO THE 6" BY ONE- EIGTH CRACK APPROX BETWEEN FRAMES 183/184 STBD SIDE OF KEEL LOCATED IN THE FOREPEAK TANK TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 19 February 1994
Resolved 19 February 1994
Deck/Cargo
Issued 29 July 1993 Resolved
MAKE REPAIRS TO CRACKED WELDS IN WAY OF CARGO TANKS #6P & #6CA AND #1C & #1SF PRIOR TO LOADING CARGO. AIR TEST REPAIRS AT NEXT PORT.
Condition: Unknown
Due 29 July 1993
Resolved 29 July 1993
Documentation
Issued 7 July 1993 Resolved
PROVIDE THE FOLLOWING FOR COMPLIANCE WITH THE DRUG TESTING REGULATIONS 46CFR16: DOCUMENTATION OF CREW'S TRAINING: IDENTIFYING TRAINING GIVEN IN 46CFR16.401; POST HOT-LINE PHONE NUMBER; PROVIDE TRAINING DOCUMENTATION FORINDIVIDUALS CONDUCTING COLLECTION OF SPECIMENS.
Condition: Unknown
Due 7 July 1993
Resolved 7 July 1993
Accommodation/Occupational Safety
Issued 29 June 1993 Resolved
PROVIDE DOOR LATCHES FOR ALL STAIRWAY DOORS.
Condition: Unknown
Due 12 July 1993
Resolved 12 July 1993
Lifesaving
Issued 29 June 1993 Resolved
RENEW ALL FOUR (4) LIMIT SWITCHES IN WAY OF LIFE BOAT DAVITS.
Condition: Unknown
Due 30 July 1993
Resolved 30 July 1993
Deck/Cargo
Issued 29 June 1993 Resolved
MARK "HIGH" AT HIGH LEVEL ALARM FOR CARGO ALARM IN WAY OF DECK HOUSE FRONT.
Condition: Unknown
Due 12 July 1993
Resolved 12 July 1993
Lifesaving
Issued 29 June 1993 Resolved
REPAIR HOLE IN WAY OF EMERGENCY GEAR LOCKER BULKHEAD, STBD SIDE ON MAIN DECK FWD OF MAIN HOUSE.
Condition: Unknown
Due 12 July 1993
Resolved 12 July 1993
Engineering
Issued 29 June 1993 Resolved
DEMONSTRATE PROPER OPERATION OF THE BURNER, PUMP FORCE DRAFT FAN CUTOUT FORTHE "SPANNER BOILER" WASTE HEAT/OIL FIRE BOILER #J5438._x001C_
Condition: Unknown
Due 12 July 1993
Resolved 12 July 1993
Deck/Cargo
Issued 29 June 1993 Resolved
DEMONSTRATE PROPER OPERATION OF THE LOW AIR CUTOUT FOR THE THERMAL FLUID HEATER #200SB.
Condition: Unknown
Due 12 July 1993
Resolved 12 July 1993
Electrical
Issued 29 June 1993 Resolved
MAKE PERMANENT REPAIRS TO THE DIESEL OIL SUPPLY LINE IN WAY OF THE EMERGENCY GENERATOR WHERE TEMPORARY PATCH IS IN PLACE.
Condition: Unknown
Due 30 July 1993
Resolved 30 July 1993
Deck/Cargo
Issued 29 June 1993 Resolved
PROVIDE MECHANICAL PLUGS FOR OIL TANK VENT CONTAINMENTS AFT ON BOTH PORT AND STBD SIDES OF SUPERSTRUCTURE.
Condition: Unknown
Due 30 July 1993
Resolved 30 July 1993
Documentation
Issued 29 June 1993 Resolved
PROVIDE THE FOLLOWING FOR COMPLIANCE WITH THE DRUG TESTING REGULATIONS 46CFR16: DOCUMENTATION OF CREW'S TRAINING; IDENTIFYING TRAINING GIVEN IN 46CFR16.401; POST HOT-LINE PHONE NUMBER; AND PROVIDE TRAINING DOCUMENTATIONFOR INDIVIDUALS CONDUCTING COLLECTION OF SPECIMENS.
Condition: Unknown
Due 12 July 1993
Resolved 12 July 1993
Electrical
Issued 29 June 1993 Resolved
MAKE PERMANENT REPAIRS TO EXPLOSION PROOF FITTING FOR ELECTRICAL CONNECTIONOF FWD EMERGENCY SHUTDOWN BOX FOR CARGO PUMPS.
Condition: Unknown
Due 12 July 1993
Resolved 12 July 1993
Electrical
Issued 29 June 1993 Resolved
MAKE PERMANENT REPAIRS TO EXPLOSION PROOF FITTING FOR ELECTRICAL CONNECTIONFOR CARGO PUMP 7S SWITCH BOX. CARGO PUMP MUST REMAIN SECURED UNTIL PERMANENTLY REPAIRED.
Condition: Unknown
Due 12 July 1993
Resolved 12 July 1993
Deck/Cargo
Issued 29 June 1993 Resolved
REPAIR HOLE TO 3AS P.V. VALVE VACUUM HOUSING.
Condition: Unknown
Due 12 July 1993
Resolved 12 July 1993
Fire Fighting
Issued 29 June 1993 Resolved
PROVIDE DOG FOR CLOSURE OF AIR VENT STBD SIDE, AFT OF HOT OIL HEATER HOUSE.
Condition: Unknown
Due 12 July 1993
Resolved 12 July 1993
Deck/Cargo
Issued 10 August 1992 Resolved
MARK OVERFLOW AND HIGH LEVEL ALARMS AS PER 46 CFR 153.408(d) and 153.409(d)
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Navigation
Issued 10 August 1992 Resolved
CLEAN OR RENEW PORT AND STBD NAVIGATION LIGHT LENSES
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Lifesaving
Issued 10 August 1992 Resolved
DEMONSTRATE FIRE AND BOAT DRILL IN THE PRESENCE OF A CG MARINE INSPECTOR
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Lifesaving
Issued 10 August 1992 Resolved
REMARK STBD LIFEBOAT MARKINGS
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Engineering
Issued 10 August 1992 Resolved
CONDUCT HYDRO TEST OF BUNKER FUEL OIL LINES.
Condition: Unknown
Due 3 September 1992
Resolved 3 September 1992
Fire Fighting
Issued 10 August 1992 Resolved
CONDUCT HYDROSTATIC TESTS OF OUTDATED PORTABLE CO2 FIRE EXTINGUISHERS IDENTIFIED ON SERVICING REPORT DATED 10AUG92.
Condition: Unknown
Due 3 September 1992
Resolved 3 September 1992
Construction/Loadline
Issued 10 August 1992 Resolved
RENEW DECK PLATE WHERE WASTED IN ENGINEROOM FLAT UNDER FRESH WATER TANKS FOR HEAD IN WAY OF FRAME #46.
Condition: Unknown
Due 10 August 1992
Resolved 10 August 1992
Lifesaving
Issued 10 August 1992 Resolved
CONDUCT ANNUAL LIFERAFT SERVICING OF ONE 20 MAN AND ONE 6 MAN LIFERAFT.
Condition: Unknown
Due 10 August 1992
Resolved 10 August 1992
Deck/Cargo
Issued 10 August 1992 Resolved
RENEW CARGO PIPING HOLD DOWN U-BOLTS PORTSIDE MAIN DECK AREA WHERE NUTS AREWASTED.
Condition: Unknown
Due 10 August 1992
Resolved 10 August 1992
Engineering
Issued 10 August 1992 Resolved
CONDUCT INTERNAL EXAMINATION AND REQUIRED HYDRO TEST ON WASTE HEAT/OIL FIREBOILER #J5438, IN THE STACK SPACE.
Condition: Unknown
Due 10 August 1992
Resolved 10 August 1992
Deck/Cargo
Issued 10 August 1992 Resolved
PRIOR TO LOADING A CARGO REQUIRING AN OVERFLOW ALARM DEMONSTRATE OPERATION OF AUTOMATIC CLOSING VALVES FOR CARGO TANKS 6AC, 4C AND 2FC WHILE OPERATINGOVERFLOW ALARM.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Lifesaving
Issued 7 April 1991 Resolved
CONDUCT WEIGHT TEST OF NEW INSTALLED STARBOARD LIFEBOAT FALLS. TO BE COMPLETED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR NOT LATER THAN 17 APRIL 1991.
Condition: Unknown
Due 7 April 1991
Resolved 7 April 1991
Engineering
Issued 29 September 1990 Resolved
REPAIR AND PROVE OPERATION OF AUDIBLE ALARM FOR CLAYTON STEAM GENERATOR.
Condition: Unknown
Due 29 September 1990
Resolved 29 September 1990
Documentation
Issued 4 September 1990 Resolved
PROVIDE APPROVED REVISED P & A MANUAL REFLECTING MODIFICAITONS TO CARGO TANK #4C AND RELATED PIPING AND THE INTERCONNECTION OF CARGO TANKS #3F, P & S AT THE PORT MANIFOLD.
Condition: Unknown
Due 4 September 1990
Resolved 4 September 1990
Deck/Cargo
Issued 4 September 1990 Resolved
UPON COMPLETION OF E1, SET & SEAL SAFETY VALVES AND PERFORM OPERATIONAL SAFETY TESTS OF THE CLAYTON BOILER IN PRESENCE OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 4 September 1990
Resolved 4 September 1990
Deck/Cargo
Issued 4 September 1990 Resolved
PROVE PROPER OPERATION OF CARGO HIGH LEVEL ALARMS FOR CARGO TANK #6AC PRIORTO LOADING CARGO REQUIRING THIS ALARM
Condition: Unknown
Due 4 September 1990
Resolved 4 September 1990
Deck/Cargo
Issued 4 September 1990 Resolved
CONDUCT SATISFACTORY HYDROSTATIC TEST OF CLAYTON STEAM GENERATOR PRIOR TO PLACING UNIT IN SERVICE, IN THE PRESENCE OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 4 September 1990
Resolved 4 September 1990
Electrical
Issued 22 July 1988 Resolved
REROUTE WIRE GOING INTO TOP OF CONTROL PANEL ON A/C UNIT AND MOUNT DRIP SHIELD BACK ON TOP.
Condition: Unknown
Due 22 July 1988
Resolved 22 July 1988
Electrical
Issued 22 July 1988 Resolved
REPAIR AND PROVE OPERATION OF #1 SHIPS SERVICE GENERATOR OVERSPEED TRIP.
Condition: Unknown
Due 22 July 1988
Resolved 22 July 1988
Deck/Cargo
Issued 4 March 1988 Resolved
PROVE INSTALLED FACET CARGO MONITOR WILL DETECT TOLUENE & XYLENE IN ORDER TO CARRY UNDER 33CFR151 (MARPOL,ANNEX I) -OR- INSTALL RESTRICTED GAUGING REQUIRED BY 46CFR153 FOR TOLULENE & XYLENE CARRIAGE UNDER MARPOL, ANNEX II.
Condition: Unknown
Due 4 March 1988
Resolved 4 March 1988
Lifesaving
Issued 6 December 1987 Resolved
WEIGHT TEST THE #2 MOTOR LIFEBOAT WHEN THE VESSEL IS NEXT STARBOARD SIDE TOA PIER AND PROVIDE A COPY OF THE WIRE CERTIFICATION FOR THE FALLS TO THE [name withheld].
Condition: Unknown
Due 6 December 1987
Resolved 6 December 1987
Unknown
Issued 20 August 1987 Resolved
PROVIDE A SET OF C.G. APPROVED PLANS FOR THE UNDERWATER DISCHARGE FOR TANK CLEANING RESIDUE SYSTEM AND HIGH LEVEL CARGO ALARM SYSTEM TO SATISFACTION OF THE COGNIZANT OCMI
Condition: Unknown
Due 20 August 1987
Resolved 20 August 1987
Deck/Cargo
Issued 20 August 1987 Resolved
INSTALL AND PROVE OPERATION OF STROBE LIGHT FOR HIGH LEVEL CARGO ALARM SYSTEM TO THE SATISFACTION OF THE COGNIZANT OCMI
Condition: Unknown
Due 20 August 1987
Resolved 20 August 1987
Deck/Cargo
Issued 2 August 1987 Resolved
PROVIDE, INSTALL AND TEST HIGH LEVEL ALARMS FOR CARGO TANKS NOT ALREADY INSTALLED. (REWRITTEN D1 DTD 4/25/87).
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987
Deck/Cargo
Issued 2 August 1987 Resolved
PROVIDE AND INSTALL RESTRICTED GAUGING FOR CARGO TANKS. (REWRITTEN CG835 D2 DTD 4/25/87).
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987
Lifesaving
Issued 2 August 1987 Resolved
PROVIDE 24 - 40 OUNCE UNITS OF WATER FOR THE LIFEBOATS.
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987
Navigation
Issued 2 August 1987 Resolved
REPAIR AND PROVE OPERATION OF THE ENGINE ORDER TELEGRAPH SIGNAL ON THE BRIDGE.
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987
Construction/Loadline
Issued 2 August 1987 Resolved
PAINT IN LOADLINES AND DRAFT MARKS.
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987
Deck/Cargo
Issued 2 August 1987 Resolved
TEST HIGH LEVEL CARGO ALARMS.
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987
Deck/Cargo
Issued 2 August 1987 Resolved
OPEN AND MAKE AVAILABLE FOR EXAMINATION ALL CARGO TANK PRESSURE/VACUUM VALVES.
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987
Lifesaving
Issued 2 August 1987 Resolved
REPLACE WIRE ROPES FOR BOTH LIFEBOAT DAVITS.
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987
Lifesaving
Issued 2 August 1987 Resolved
PROVIDE 3 ADDITIONAL SURVIVAL SUITS FOR A TOTAL OF 34.
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987
Fire Fighting
Issued 2 August 1987 Resolved
MAKE NECESSARY ALTERATION TO THE ON DECK HYDRANTS TO PERMIT THE CLOSING AT HOSE BOX COVERS WITH THE HOSES CONNECTED TO THE HYDRANTS AS REQUIRED BY 46 CFR 34.10-10(K).
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987
Deck/Cargo
Issued 2 August 1987 Resolved
PROVE OPERATION OF THE CARGO MONITOR WHEN NEXT IN THE PORT OF PHILADELPHIA FOR COMPLETION OF IOPP SURVEY.
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987
Engineering
Issued 2 August 1987 Resolved
MAKE AVAILABLE FOR HYDROSTATIC TESTING THE WASTE HEAT BOILER DURING NEXT DRYDOCK.
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987
Construction/Loadline
Issued 2 August 1987 Resolved
VEE OUT DRILL STOP AND REWELD 4 CRACKED WELDS IN THE RUBRAIL AT THE 29 FOOTDRAFT ON THE STARBOARD SIDE AND 1 CRACKED WELD IN THE RUBRAIL AT THE 29 FOOT DRAFT ON THE PORT SIDE.
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987
Lifesaving
Issued 2 August 1987 Resolved
SERVICE BOTH LIFERAFTS AND HUYDROSTATIC RELEASES.
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987
Fire Fighting
Issued 2 August 1987 Resolved
SERVICE ALL FIXED FIRE EXTINGUISHING SYSTEMS, SEMI PORTABLE SYSTEMS AND ALLPORTABLE EXTINGUISHERS.
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987
Deck/Cargo
Issued 25 April 1987 Resolved
PROVIDE TENSILE TEST RESULTS FOR THE TUBING USED IN THE EFFICIENT STRIPPINGSYSTEM AS PER MARINE SAFETY CENTER PLAN REVIEW LETTER #C-70063.
Condition: Unknown
Due 25 April 1987
Resolved 25 April 1987
Deck/Cargo
Issued 25 April 1987 Resolved
INSTALL RESTRICTED GAUGING ON CARGO TANKS TO PERMIT CARRIAGE OF THOSE CARGOES REQUIRED TO COMPLY WITH 46CFR153.406.
Condition: Unknown
Due 25 April 1987
Resolved 25 April 1987
Deck/Cargo
Issued 25 April 1987 Resolved
INSTALL CARGO HIGH LEVEL ALARMS TO PERMIT CARRIAGE OF THOSE CARGOES REQUIRED TO COMPLY WITH 46CFR153.409.
Condition: Unknown
Due 25 April 1987
Resolved 25 April 1987
Deck/Cargo
Issued 25 April 1987 Resolved
PROVIDE MATERIAL SPECIFICATIONS ON THE BALL VALVES USED FOR THE EFFICIENT STRIPPING SYSTEM AS PER MARINE SAFETY CENTER PLAN REVIEW LETTER #C-70063.
Condition: Unknown
Due 25 April 1987
Resolved 25 April 1987
Fire Fighting
Issued 31 July 1986 Resolved
SUBMIT THE ANNUAL FIREFIGHTING FOAM ANALYSIS REPORT TO THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION FOR REVIEW.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Lifesaving
Issued 31 July 1986 Resolved
PRIOR TO SAILING, RETURN THE SERVICED 6 MAN AND THE SERVICED 20 MAN INFLATABLE RAFTS TO THEIR STATIONS.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Deck/Cargo
Issued 26 December 1985 Resolved
MAKE NITROGEN PADDING SYSTEM AVAILABLE FOR INSPECTION AND VERIFICATION AGAINST"COMPRESSED AIR AND DECK STEAM PIPING (AND NITROGEN SYSTEM), DWG NO. SV48-5-82 REV B"APPROVED 17DEC85 BY CCGD3(MMT).
Condition: Unknown
Due 26 December 1985
Resolved 26 December 1985
Deck/Cargo
Issued 26 December 1985 Resolved
PROVIDE DOCUMENTATION THAT THE FLEXIBLE HOSES USED IN THE NITROGEN PADDING SYSTEM MEET OR EXCEED 46 CFR 56.60-25.
Condition: Unknown
Due 26 December 1985
Resolved 26 December 1985
Lifesaving
Issued 7 August 1985 Resolved
HOLD A FIRE DRILL AND A BOAT DRILL IN THE PRESENCE OF A MARINE INSPECTOR PRIOR TO LEAVING GALVESTON SHIPYARD PERIOD.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Lifesaving
Issued 7 August 1985 Resolved
PROVIDE OPERATIONAL COMBUSTIBLE GAS INDICATORS PRIOR TO LEAVING GALVESTON SHIPYARD PERIOD. (46 CFR 35.30-15)
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Fire Fighting
Issued 7 August 1985 Resolved
PROVIDE GLOVES MEETING 46 CFR 35.30-20(C)(2) FOR PROTECTIVE CLOTHING IN THEEMERGENCY GEAR LOCKER STARBOARD SIDE MAIN DECK IN THE HOUSE PRIOR TO LEAVING GALVESTON SHIPYARD PERIOD.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Lifesaving
Issued 7 August 1985 Resolved
CONDUCT WEIGHT TEST OF BOTH LIFEBOATS IN THE PRESENCE OF A MARINE INSPECTOR. (46 CFR 33.01-27). TO BE COMPLETED PRIOR TO LEAVING GALVESTON SHIPYARD PERIOD.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Fire Fighting
Issued 7 August 1985 Resolved
PROVIDE RESULTS OF FOAM SAMPLE TEST TO [name withheld], PA.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Fire Fighting
Issued 7 August 1985 Resolved
PROVIDE ONE ADDITIONAL SCBA FOR THE SAFETY EQUIPMENT LOCKER FORWARD OF THE HOUSE PRIOR TO LEAVING GALVESTON SHIPYARD PERIOD. (46 CFR 153.215)
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Lifesaving
Issued 7 August 1985 Resolved
PROVIDE ONE ADDITIONAL SURVIVAL SUIT FOR A TOTAL OF 30 PRIOR TO LEAVING GALVESTON SHIPYARD PERIOD. (46 CFR 33.37-5).
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Lifesaving
Issued 7 August 1985 Resolved
PROVIDE DETECTION TUBES FOR TOXIC VAPOR DETECTOR FOR ALL CARGOES REQUIRING TOXIC VAPOR DETECTION PRIOR TO LEAVING GALVESTON SHIPYARD PERIOD. (46 CFR 153.526).
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Lifesaving
Issued 7 August 1985 Resolved
REPAIR GENERAL ALARM BELL AT LADDER TO BRIDGE ON DECK OFFICERS FLAT PRIOR TO LEAVING GALVESTON SHIPYARD PERIOD.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Lifesaving
Issued 7 August 1985 Resolved
PROVIDE LIMIT SWITCHES FOR LIFEBOAT DAVIT ARMS FOR BOTH LIFEBOATS. (46 CFR 160.015-3(J) & (K)).
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Electrical
Issued 7 August 1985 Resolved
PROVIDE COVERS ON PORT OUTBOARD FLOURESCENT LIGHT FIXTURES IN CARGO PUMP CONTROL ROOM PRIOR TO LEAVING GALVESTON SHIPYARD PERIOD.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Deck/Cargo
Issued 7 August 1985 Resolved
SUBMIT PLANS FOR EXISTING CARGO TANK NITROGEN PADDING SYSTEM TO [name withheld] DISTRICT (MMT).
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Engineering
Issued 7 August 1985 Resolved
MAKE REPAIR TO ER OIL WATER SEPERATOR DISCHARGE OVERBOARD PUMP TO STOP PUMPING WHEN PPM IS EXCEEDED. TO BE WITNESSED BY CG MARINE INSPECTOR. (46 CFR 162.050).
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Accommodation/Occupational Safety
Issued 7 August 1985 Resolved
COMPLETE INSPECTION ON HEATING BOILER. MARINE INSPECTOR TO WITNESS FIRESIDEAND WATERSIDE INTERNALS, AND 1 1/4 TIMES MAWP HYDRO OF HEATING BOILER.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Construction/Loadline
Issued 7 August 1985 Resolved
INSTALL METAL TAGS ON BALLAST TANKS #1AP, 1AS, AND 2AP WHICH STATE, "CERTIFIED WATER BALLAST". (46 CFR 69.03-73(C)).
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Deck/Cargo
Issued 7 August 1985 Resolved
SUBMIT TO COMMANDER(MMT), THIRD COAST GUARD DISTRICT REVISED TRIM AND STABILITY BOOKLET SHOWING #6 WING P/S TANKS AS CARGO TANKS ONLY.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Engineering
Issued 7 August 1985 Resolved
DEMONSTRATE ALL SAFETY DEVICES AND CONTROLS ON HEATING BOILER TO MARINE INSPECTOR.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Fire Fighting
Issued 7 August 1985 Resolved
SERVICE ALL FIXED FIRE EXTINGUISHING SYSTEMS, AND ALL SEMI-PORTABLE AND PORTABLE FIRE EXTINGUISHERS TO SATISFACTION OF COGNIZANT OCMI. TO BE COMPLETED PRIOR TO DEPARTURE FROM GALVESTON SHIPYARD PERIOD. (46 CFR 31.10-10(B)).
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Lifesaving
Issued 7 August 1985 Resolved
SERVICE THE 6 MAN LIFERAFT PRIOR TO DEPARTURE FROM GALVESTON SHIPYARD PERIOD. PROVIDE SERVICING CERTIFICATE TO COGNIZANT OCMI.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Lifesaving
Issued 7 August 1985 Resolved
SERVICE THE HYDROSTATIC RELEASES FOR BOTH LIFERAFTS PRIOR TO DEPARTURE FROM GALVESTON SHIPYARD PERIOD. PROVIDE SERVICING CERTIFICATE TO COGNIZANT OCMI.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Lifesaving
Issued 7 August 1985 Resolved
REATTACH WATERLIGHT BRACKET FOR RINGBUOY ON PORT SIDE OF AFTER BOATDECK PRIOR TO LEAVING GALVESTON SHIPYARD PERIOD.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Lifesaving
Issued 7 August 1985 Resolved
HYDROSTATICALLY TEST THE SPARE OXYGEN CYLINDER IN THE HOSPITAL SPACE PRIOR TO LEAVING GALVESTON SHIPYARD PERIOD.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Fire Fighting
Issued 7 August 1985 Resolved
RECHARGE THE SPARE COMPRESSED AIR CYLINDER IN THE EMERGENCY GEAR LOCKER ON THE MAIN DECK STARBOARD IN THE HOUSE PRIOR TO LEAVING GALVESTON SHIPYARD PERIOD.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Fire Fighting
Issued 7 August 1985 Resolved
PROVIDE ONE ADDITIONAL SET OF PROTECTIVE CLOTHING OF MATERIAL THAT WILL PROTECT THE SKIN FROM THE HEAT OF FIRE AND BURNS FROM SCALDING STEAM AND WHICH ALSO HAS AN OUTER SURFACE THAT IS WATER RESISTANT. (46 CFR 35.30-20(C)(2)).
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Electrical
Issued 7 August 1985 Resolved
RENEW GLOBE OVER PORT OUTBOARD HYDRAULIC PUMPING FOC'SLE PRIOR TO LEAVING GALVESTON SHIPYARD PERIOD.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985

Casualty record · 6

5 May 2003Routine · role: Involved in a Marine Casualty · activity 1789976
11 November 2003Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 1965534
16 July 2005Routine · role: Involved in a Marine Casualty · activity 2444214
5 March 2007Routine · role: Involved in a Marine Casualty · activity 2882819
18 May 2008Routine · role: Involved in a Marine Casualty · activity 3212511
21 August 2008Routine · role: Involved in a Marine Casualty · activity 3304894
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.