Inspection history · 105
7 July 2026
Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8431396
25 June 2026
In-Service Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8420291
29 May 2026
Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8384059
15 April 2026
Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8320558
24 February 2026
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8314994
10 February 2026
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8309140
20 January 2026
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8298489
20 January 2026
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8298679
15 January 2026
Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8270564
6 January 2026
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8291305
6 January 2026
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8296206
2 January 2026
Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8289336
18 December 2025
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8285541
16 October 2025
Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8230446
31 August 2025
Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8225461
18 July 2025
COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8182151
17 April 2025
Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8099932
19 February 2025
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8085685
16 January 2025
Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8063405
5 December 2024
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8046614
3 October 2024
Periodic Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8014378
3 September 2024
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7996776
16 July 2024
COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7925832
1 February 2024
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7845589
19 September 2023
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7802058
7 September 2023
COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7775463
8 July 2023
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7745578
29 June 2023
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7725411
15 March 2023
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7650816
4 January 2023
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7616369
8 December 2022
Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7606048
30 September 2022
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7569201
8 September 2022
COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7546150
16 June 2022
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7480171
11 June 2022
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7476139
11 March 2022
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7410862
11 March 2022
Deficiency Check · Special
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7411192
10 March 2022
Re-Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7407313
27 December 2021
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7374959
27 December 2021
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7388259
15 December 2021
Re-Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7368103
1 December 2021
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7360510
9 September 2021
COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7301986
8 July 2021
Special
Type not classified · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7249949
7 July 2021
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7291612
10 June 2021
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7206124
19 March 2021
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7166098
11 March 2021
Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7152163
12 February 2021
Special · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7141257
27 December 2020
Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7116856
16 December 2020
Deficiency Check · MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7113334
16 December 2020
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7180540
21 October 2020
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7081438
15 July 2020
MTSA Verification · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7006884
10 June 2020
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7001014
14 April 2020
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6949265
4 December 2019
Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6867396
23 October 2019
Deficiency Check · Re-Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6840891
23 September 2019
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6822691
10 September 2019
Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6809269
17 August 2019
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6790844
17 August 2019
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6815032
19 July 2019
Administrative Inspection · Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6785433
13 July 2019
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6808729
10 July 2019
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6770688
1 June 2019
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6728574
9 May 2019
Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6680660
8 May 2019
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6695439
13 April 2019
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6666041
21 March 2019
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6690863
12 March 2019
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6642399
4 March 2019
Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6646230
4 March 2019
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6693883
29 January 2019
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6618664
30 November 2018
MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6589755
17 July 2018
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6491207
20 April 2018
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6395383
22 January 2018
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6341459
14 November 2017
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6307843
14 November 2017
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6380148
29 October 2017
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6310950
23 October 2017
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6296125
23 October 2017
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6308620
19 October 2017
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6290686
2 August 2017
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6234133
29 June 2017
MTSA/ISPS Verification · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6190863
19 April 2017
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6136463
17 March 2017
Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6114377
17 March 2017
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6114457
18 January 2017
Administrative Inspection · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6138252
17 October 2016
Deficiency Check · MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6024579
19 August 2016
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5977090
26 July 2016
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5953511
25 July 2016
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6036515
21 July 2016
MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5961567
9 July 2016
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5936573
9 July 2016
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5936707
19 May 2016
Re-Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5880617
20 April 2016
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5861764
9 March 2016
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5834629
19 February 2016
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5820534
11 February 2016
Administrative Inspection · MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5812977
7 February 2016
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5811290
27 January 2016
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5804602
27 January 2016
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5804736
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 May 2026
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Marine Vessel Rules (incorporated by reference, see § 58.03-1), except as otherwise provided by this subchapter. The starboard main diesel engine's cooling water is running high. Make necessary repairs to the starboard main diesel engine's cooling water system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2026
Resolved 1 June 2026
Resolution: Received objective evidence that the engine oil cooler and marine gear oil cooler was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 15 April 2026
Resolved
Each lifeboat, rigid liferaft, and rescue boat, unless otherwise stated in this paragraph, must carry the equipment listed in this paragraph and specified for it in table 1 to this section under the vessel's category of service. A lifeboat that is also a rescue boat must carry the equipment in the table column marked for a lifeboat. MI inspected that the Heaving line with quot attached. The quoit was dry rotted and will need to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2026
Resolved 23 April 2026
Resolution: Line heaving device was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 January 2026
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Marine Vessel Rules (incorporated by reference, see § 58.03-1), except as otherwise provided by this subchapter. The engine to the #1 generator overheated and subsequently shutdown. Complete repairs to the #1 generator.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2026
Resolution: The keel cooler valve was in the closed position. The crew opened the valve and completed satisfactory test of the #1 generator.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 6 January 2026
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Marine Vessel Rules (incorporated by reference, see § 58.03-1), except as otherwise provided by this subchapter. The # 1 generator overheated and subsequently shutdown. Complete repairs to the #1 generator. The engine to the #1 generator overheated and subsequently shutdown. The overheat alarm did not go off as it should. Proper PSTPs must be completed in the presence of a USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2026
Resolved 7 January 2026
Resolution: Winessed satisfactory PSTP for the overheat alarm sensor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 January 2026
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Marine Vessel Rules (incorporated by reference, see § 58.03-1), except as otherwise provided by this subchapter. The starboard main engine has an oil coolant leak. Complete repairs as needed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2026
Resolved 15 January 2026
Resolution: Coolant has not needed to be added to machinery. Repairs appear to be satisfactory
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 August 2025
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Marine Vessel Rules (incorporated by reference, see § 58.03-1), except as otherwise provided by this subchapter.
The crew discovered a leak in the rear void coming from the starboard rudder shaft seal. Complete repairs as needed to the satisfaction of the attending USCG marine inspector. Meanwhile ensure bilge pump is working, continue to conduct rounds of the rear void every 45 minutes and seize operations if the bilge pump is unable to keep up with the leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2025
Resolved 5 September 2025
Resolution: Operator provided evidence rectifying deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 18 July 2025
Resolved
All enclosed spaces within the vessel shall be properly vented or ventilated. Means shall be provided to close off all vents and ventilators. No.5 void goose neck vent wasted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2025
Resolved 12 August 2025
Resolution: Recieved picture evidence the gooseneck was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 July 2025
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Marine Vessel Rules. Both MDEs have on going long term jacket water leaks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2025
Resolved 12 August 2025
Resolution: Both leaks were repaired with OEM parts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 September 2023
Resolved
STBD MDE overspeed alarm not sounding in EOS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2023
Resolved 19 September 2023
Resolution: Maintenance adjusted the alarm time delay to ensure it promptly sounds in the EOS; test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 September 2023
Resolved
STBD steering ram leaking hydraulic fluid.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2023
Resolved 19 September 2023
Resolution: Steering ram was replaced; op test sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 September 2023
Resolved
STBD rudder packing gland leaking excessively. (20 gallons a day)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2023
Resolved 19 September 2023
Resolution: Failed grease line was discovered and replaced. After greasing and adjustment of the packing gland leak has slowed to acceptable amount for cooling. Rudder box to be serviced/ sleaved this upcoming dry dock period.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 8 December 2022
Resolved
There must be no cracking, softening, deterioroation, breakage, leakage, or damage of components or materials that affect the operation of the MSD. Inboard MSD tank on STBD side found with multiple leaks. Outboard MSD tank on STBD side found with 01 Leak IAW 33CFR159.101.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2023
Resolved 4 January 2023
Resolution: Recieved pictures of repairs and written report of succesful operational testing. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 September 2022
Resolved
Bilge pump system is inoperable in the port ballast space. 46CFR56.50-50(a)
Action required: 10 - Deficiency Rectified
Due 8 September 2022
Resolved 8 September 2022
Resolution: NCDOT engineering crew made repairs to the suction (check valve was seized) in the port ballast space and proved proper operation to attending MI, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 September 2022
Resolved
#1 bilge pump discharge gasket found wasted and leaking. 46CFR56.50-55(a).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2022
Resolved 30 September 2022
Resolution: Tech report and video of bigle system properly operating, SAT
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 16 June 2022
Resolved
Belt for E-gen is beginning to wear. Replace prior to failure IAW 46CFR112.05-5.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2022
Resolved 15 July 2022
Resolution: Belt replaced.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 June 2022
Resolved
Blower motor on port side engine room has failed. Repair/replace IAW 46CFR72.05-50.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2022
Resolved 15 July 2022
Resolution: motor repaired. verified ooperation.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 16 June 2022
Resolved
Rescue boat gear selector is beginning to Chaffe/fail. Replace prior to failure IAW 46CFR199.190(a).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2022
Resolved 15 July 2022
Resolution: gear selector replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 16 June 2022
Resolved
Windows in starboard side passenger lounge are cracked. Replace with new and remedy cause for vessel making contact with pylon/bumpers at docks near window area IAW 46CFR72.05-30(a).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2022
Resolved 15 July 2022
Resolution: verified windows replaced.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 June 2022
Resolved
Nozzle on hydrandt for fire control station in engine room is leaking excessively. Replace/repair as needed IAW 46CFR76.10-10(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2022
Resolved 15 July 2022
Resolution: hydrant repaired. conducted test under pressure. all sat.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 June 2022
Resolved
MI notified of dc battery charger failure and battery issues affecting the following systems; AIS, VHF RADIO, COMPASS, DEPTH SOUNDER, and GPS unit. Troubleshoot and conduct permanent repairs IAW 46CFR70.25-1. Provide tech report and CAPT attestation to attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2022
Resolution: New battery and charges installed all test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 11 March 2022
Resolved
Rescue boat davit remote control handle diconnected from cable while testing. Make repairs IAW 46CFR199.45(C)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2022
Resolution: New remote controls cable installed and operation testing sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 11 March 2022
Resolved
Emergency generator failed to start. trouble shoot and make permanent repairs IAAW 46CFR112.50-5
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2022
Resolution: New starter installed and operational test sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 March 2022
Resolved
Fire hose on number 01 fire station is worn. Replace in accordance with 46CFR76.10-10
Action required: 10 - Deficiency Rectified
Due 10 March 2022
Resolved 10 March 2022
Resolution: Fire hose replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 March 2022
Resolved
Fuel lines for EDG are missing support hangers. Bilge suction in MSD space is also missing support hangers. Replace/repair in accordance with 46CFR56.50-75.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2022
Resolved 1 April 2022
Resolution: New bolts installed.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 10 March 2022
Resolved
Both shaft alleys are missing machine guards. Install in accordance with 46CFR58.01-20.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2022
Resolved 1 April 2022
Resolution: Handrail/chains were installed
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 March 2022
Resolved
Control room must have 02 means of escape. 01 means of escape is blocked with a chair. Ensure means of escape in accordance 46CFR72.10-5.
Action required: 10 - Deficiency Rectified
Due 10 March 2022
Resolved 10 March 2022
Resolution: Chair removed from control room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 December 2021
Resolved
Vessel #2 generator is surging at volts near 300, voltage regulator fuse blown. Identify cause for surging, investigate/check fuses for related systems and test to the satisfaction of the attending CG Marine Inspector iaw 46 CFR 111.01-1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2021
Resolution: Wiring identified as chaffed and causing ground on generator #2, replaced wiring, replaced fuses and tested sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 15 December 2021
Resolved
Vessel emergency generator fuel supply line is chafed and badly worn. Minor leak identified at the time of inspection was remedied but hose need to be replaced iaw 46 CFR 112.05-1.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2021
Resolved 27 December 2021
Resolution: E-gen fuel line replaced, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 December 2021
Resolved
Vessel's #2 generator jacket water hard piping has pinhole leak at bracket support, repair or replace with new iaw 46 CFR 111.01-1.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2021
Resolved 27 December 2021
Resolution: Generator jacket water piping replaced, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 December 2021
Resolved
Vessel reported that the life boat davit converter is showing a trouble code of a capacitor fault and tripping off line. Trouble shoot and make permanent repairs to satisfaction of attending [name withheld] 46CFR70.25-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2021
Resolution: Replaced with new phase controller, tested sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 September 2021
Resolved
Vessel has improperly rated current protection for main engine. Battery charger and bow gate receptacle. IAW 46CFR111.40
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2021
Resolved 8 October 2021
Resolution: Drawings were reviewed and corrected. Correct breakers were purchased and installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 September 2021
Resolved
#4 void suction check valve found seized closed. Valve became unseized after impacts with hammer. remove components of valve and suction piping to make available for inspection. IAW 46CFR56.50-56
Action required: 705 - Other - as specified
Due 17 September 2021
Resolved 11 September 2021
Resolution: check valve serviced. Bilge suction test SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 September 2021
Resolved
#5 void suction unable to be tested due to oil residue in bilges. Remove oil and clean space in order to test suction. IAW 46CFR56.50.50
Action required: 705 - Other - as specified
Due 17 September 2021
Resolved 15 September 2021
Resolution: void cleaned and bilge suction tested
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 10 September 2021
Resolved
Rescue boat retroreflective material found deteriorated. Replace in accordance with 46CFR199.176.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2021
Resolved 5 October 2021
Resolution: replaced retro on lifeboat
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 September 2021
Resolved
Flammable and combustible material improperly stored in engine room. Properly stow in approved flame locker. IAW 46CFR71.25-45
Action required: 705 - Other - as specified
Due 14 September 2021
Resolved 10 September 2021
Resolution: flammable material removed from the vessel
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 9 September 2021
Resolved
Bridge first aid kit found with expired medication. IAW 46CFR160.041
Action required: 10 - Deficiency Rectified
Due 10 September 2021
Resolved 14 September 2021
Resolution: Expired medicine replaced
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 September 2021
Resolved
Port liferaft painter line not attached to weak link IAW manufactures instructions. IAW 46CFR149.190
Action required: 10 - Deficiency Rectified
Due 10 September 2021
Resolved 10 September 2021
Resolution: liferaft properly rigged
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 8 July 2021
Resolved
Vessel reported a loss of steering while approaching dock. Crew found the stbd ram eye bolt backed out of the coupling. Vessel is to complete permanet repairs and send the following reports CG2692, Tech Report addressing the repair, to include why the current part failed. Once repairs are completed contact Nags Head Marine Inspector prior to carring passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2021
Resolution: Ram and eye bolt inspected. Installed eye bolt and tack welded into place. Underway test completed. Test SAT.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 11 March 2021
Resolved
Found port sewage treatment plant not functioning properly. Repair treatment system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2021
Resolved 19 March 2021
Resolution: Sewage tank was cleaned; op test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 February 2021
Resolved
Starboard main engine throttle controls are not functioning as intended. Provide corrective action taken and prove proper operation to the attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 February 2021
Resolution: Throttle controls now operating sat.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 December 2020
Resolved
Installed hydostatic release is expired on both port and starboard IBA's. Replace with new hydrostatic release prior to carrying passengers on 17DEC2020.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2020
Resolved 16 December 2020
Resolution: New hydrostatic release installed on both port and starboard IBA's.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 16 December 2020
Resolved
Ensure vessel checks, tests, and inspections of lifesaving appliances are carried out iaw 46 CFR Subchapter W prior to carrying passengers on 17DEC2020.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 December 2020
Resolved 16 December 2020
Resolution: Spoke with QA, internal inspection checklist will be updated to include hydrostatic relesae, currently vague requirement for "inspecting IBA's" is inadequate.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 21 October 2020
Resolved
Starboard alarms panel that monitors the starboard main engine and #2 SSDG is displaying false alarms at random. Determine cause of alarms and provide repairs to function as intended.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2020
Resolution: Installed a new alarm panel in the EOS; op test sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 15 July 2020
Resolved
Found vessels Emergency Generator inoperable. Make repairs and have attending U.S. Coast Guard Marine Inspector verify proper operation prior to vessel carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2020
Resolution: E-Gen tested and found sat.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 14 April 2020
Resolved
Starboard main engine shuts down on low lube oil pressure but does not provide a vissual indicator. Provide visual indicator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2020
Resolved 10 June 2020
Resolution: Visual indicator funtioning properly.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 14 April 2020
Resolved
Rudder indicator in the EOS booth stops at 22 degrees to starboard when in non-followup position on system #1. Repair rudder angle indicator feeback.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2020
Resolved 10 June 2020
Resolution: Rudder and indicator funtioning properly.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 December 2019
Resolved
The owner, master, or PIC shall perform the tests and inspections of all hand portable fire extinguishers as described in 46 CFR 71.25-20. During the inspection, inspectors were unable to verify that satisfactory maintenance was performed on the portable extinguishers by a properly licensed servicing facility/individual.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2019
Resolved 19 December 2019
Resolution: Fire extinguishers have been serviced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 September 2019
Resolved
Vessel suffered a loss of propulsion controls due to failure of the control air system. Complete repairs and contuct operational test.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 October 2019
Resolved 12 September 2019
Resolution: Control air system repaired.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 19 July 2019
Resolved
Found machinery alarm repeater on bridge not functioning. Repair alarm system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2019
Resolved 23 September 2019
Resolution: Alarm system repaired and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 May 2019
Resolved
Vessel received damage to the stbd propeller resulting in two broken blades; confirmed by diver. Vessel is prohibited from carrying passengers until repairs have been completed. Vessel is permitted transit to NCDOT Shipyard in Manns Harbor, NC to effect repairs.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2019
Resolution: Witnessed blue fit of new starboard propellor on new shaft, witnessed dye pen testing of new shaft key ways, and witnessed final installation of new starboard propellor.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 13 April 2019
Resolved
Pilot house alarm repeater panel is giving a false alarm (port MDE low lube oil) following a possible power surge associated with a severe electrical storm.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2019
Resolved 26 April 2019
Resolution: Port PMC EOS Alarm Annunciator Panel was replaced and both (Port/Stbd) EOS PMC Alarm Annunciator Panels were reprogrammed to communicate with the alarm repeater panel in the pilothouse. System no working as designed without errors.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 12 March 2019
Resolved
Emergency Generator prime mover would not operate due to a failed fuel solenoid. Repair generator.
Action required: 10 - Deficiency Rectified
Due 14 March 2019
Resolved 14 March 2019
Resolution: Fuel Solenoid replaced with serviceable unit.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 March 2019
Resolved
Breaker handle for automatic switch over from normal ship's power to emergency ship's power was broken. Replace breaker handle with serviceable unit.
Action required: 10 - Deficiency Rectified
Due 14 March 2019
Resolved 14 March 2019
Resolution: Breaker handle was replaced with serviceable breaker handle.
Engineering › Steering Gear System › Linkage
Issued 14 November 2017
Resolved
Love joint connecting electrical motor to hydraulic pump on the #1 steering system failed resulting in loss of steering.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2017
Resolution: Verified repair of #1 steering system and witnessed full function test. All sat.
Engineering › Steering Gear System › Feedback Unit
Issued 24 October 2017
Resolved
Found steering system #1 unable to maneuver 35 deg. to 35 deg. on either side. repair system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2017
Resolution: Technicians replaced a bad micro switch and repaired the switch actuation cam.
Fire Fighting › Structural - A Class Divisions › Windows
Issued 19 October 2017
Resolved
Found (02) broken windows in port passenger lounge. Replace in kind.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 2 November 2017
Resolved 27 October 2017
Resolution: Installed new windows.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 19 October 2017
Resolved
Found break-glass type box adjacent to EDG space, containing pull handle for CO2 system missing glass. Glass located before MI's departed the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 November 2017
Resolved 19 October 2017
Resolution: Corrected on the spot.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 October 2017
Resolved
Found mast head light inoperable. Bulb replaced on the spot.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2017
Resolved 19 October 2017
Resolution: Bulb replaced on the spot.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 21 July 2017
Resolved
Unable to verify/test low lube oil alarms on port & starboard Main Diesel Engines.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 21 August 2017
Resolved 2 August 2017
Resolution: Witnessed verification/ testing of port and stbd MDE low lube oil pressure alarms.
Fire Fighting › Fire Pumps › Pressure
Issued 21 July 2017
Resolved
Unable to test outlet pressure from fire hoses. Provide pitot tupe tester to test.
Action required: 705 - Other - as specified
Due 4 August 2017
Resolved 2 August 2017
Resolution: Witnessed satisfactory pitot tube test.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 20 April 2017
Resolved
Renew foam strips in all ventilation dampers. Current foam is not appropriate for application.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 27 April 2017
Resolution: Foam for ventilation dampers was replaced with the correct material.
Lifesaving › Lifebuoys › Serviceable
Issued 20 April 2017
Resolved
Replace worn life ring with suitable replacement.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 27 April 2017
Resolution: Replaced life ring with new life ring.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 17 March 2017
Resolved
Repair leaking diesel filter/separator assembly to the satisfaction of the attending marine inspector before operating with passengers.
Action required: 705 - Other - as specified
Due 18 March 2017
Resolved 18 March 2017
Resolution: Filter/separator assembly was replaced with a new unit.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Emergency shutdown
Issued 17 October 2016
Resolved
Emergency generator would not shut down on low lube oil pressure. WQSB must be altered to have watchstander present when EDG operates.
Action required: 705 - Other - as specified
Due 18 October 2016
Resolved 18 October 2016
Resolution: Repaired EDG by re-routing shutdown circuit through another circuit board.
Accommodation/Occupational Safety › Ventilation › General
Issued 19 August 2016
Resolved
Port and starboard engine room ventilation fans reported inoperable. Prove proper operation of vent fans such that an adequate supply of air is provided to the engine room to maintain the operation of the machinery and for the safety, efficiency, and comfort of the crew.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 22 August 2016
Resolution: Starboard engine room vent fan was replaced. Failed capacitor on the port side engine room vent fan also replaced. Both fans tested and found fully function.
Engineering › Steering Gear System › Motor
Issued 26 July 2016
Resolved
#1 steering gear motor shorted out and caught fire due to the shorting out of a wire following its improper installation with wire nuts.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2016
Resolution: A new motor for the #1 steering system was properly installed by a marine electrician. Wire connections were made using compression type fittings and a new rubber gasket was fitted in the junction box cover where previously it was missing.
Fire Fighting › Fire Main › Valves
Issued 21 July 2016
Resolved
Found both PTO fire pumps capable of producing pressures excess of 125 psi to the firemain with no safety relief valve installed. Install relief valve during next scheduled dry dock.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 August 2018
Resolved 31 October 2019
Resolution: Sector NC issued ltr to NCDOT permitting current configuration/operation until next scheduled drydock.
Communications › Internal Communications System › Sound-powered Telephone
Issued 11 February 2016
Resolved
Provide sound powered phone headset and cable as needed for local alternate controls on the MDE's.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 19 May 2016
Resolution: Sector [name withheld] stated that they were okay without them.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 February 2016
Resolved
Wire properly automatic bilge pumps in shaft alley's (2).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 19 May 2016
Resolution: Automatic bilge pumps were wired properly as required.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 11 February 2016
Resolved
Replace missing insulation as needed in engine room.
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 19 May 2016
Resolution: Missing insulation was replaced in the engine room as required.