Records from 2002 to 2026. Most recent: inspection, 15 July 2026.
Inspection history · 165
15 July 2026
Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8421172
22 May 2026
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8378341
17 April 2026
Vessel Attendance · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8351361
13 April 2026
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8349542
2 April 2026
Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8341812
26 March 2026
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8296185
10 March 2026
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8323601
18 February 2026
Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8311930
7 January 2026
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8291392
24 December 2025
Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8287153
24 December 2025
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8295349
17 December 2025
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8284734
17 December 2025
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8291518
11 December 2025
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8271438
2 October 2025
Deadweight Survey · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8229768
1 July 2025
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8172014
1 July 2025
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8200206
17 June 2025
COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8147232
15 March 2025
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8095020
12 December 2024
Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8057305
16 August 2024
Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7991927
24 July 2024
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7967430
26 June 2024
Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7953095
29 April 2024
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7903261
21 March 2024
Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7883075
18 March 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7880852
18 March 2024
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7889904
8 March 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7876057
8 March 2024
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7879135
22 February 2024
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7855435
20 February 2024
Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7867518
22 December 2023
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7841775
30 November 2023
Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7829874
29 September 2023
Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7795891
29 September 2023
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7809748
15 September 2023
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7802424
8 August 2023
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7760213
18 May 2023
Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7690700
22 April 2023
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7676721
17 March 2023
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7660198
5 March 2023
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7646070
24 February 2023
MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7635996
22 June 2022
Deadweight Survey · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7484866
25 May 2022
Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7472930
16 May 2022
Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7451766
15 May 2022
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7522317
10 May 2022
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7447803
11 April 2022
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7428588
17 March 2022
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7408261
14 February 2022
Deficiency Check · Special
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7398303
14 February 2022
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7408300
26 January 2022
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7386013
26 January 2022
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7396908
15 January 2022
Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7386332
15 January 2022
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7396645
16 December 2021
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7368931
3 November 2021
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7343516
21 September 2021
Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7317779
18 June 2021
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7206198
18 March 2021
Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7157725
9 December 2020
MTSA/ISPS Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7104196
1 September 2020
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7065119
28 August 2020
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7046988
10 June 2020
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7042804
12 February 2020
COI Inspection · Administrative Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6907191
28 January 2020
Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6899707
19 December 2019
Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6879466
13 December 2019
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6873386
5 December 2019
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6870843
26 October 2019
Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6846634
3 October 2019
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6828297
19 September 2019
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6814280
26 July 2019
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6776897
12 June 2019
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6763023
29 April 2019
COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6672424
25 October 2018
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6574767
1 August 2018
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6497672
23 July 2018
Administrative Inspection · MTSA Verification · Re-Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6489376
12 June 2018
Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6475534
10 May 2018
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6411794
18 April 2018
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6399440
22 March 2018
COI Inspection · MTSA Verification · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6376206
21 December 2017
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6327338
28 November 2017
Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6326404
5 October 2017
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6282643
21 September 2017
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6272484
13 August 2017
Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6240693
27 July 2017
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6234375
26 July 2017
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6281199
1 June 2017
Special · Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6162846
13 March 2017
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6104101
1 January 2017
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6079508
27 December 2016
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6064986
2 December 2016
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6053322
3 October 2016
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6014951
9 September 2016
Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5999482
28 July 2016
Special
Type not classified · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5956060
26 June 2016
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5931270
27 May 2016
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5887804
29 February 2016
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5825085
17 February 2016
MTSA Verification · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5816533
9 December 2015
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5778028
17 November 2015
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5765179
19 August 2015
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5220081
22 October 2014
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5010916
15 October 2014
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5013353
21 August 2014
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4961066
10 August 2014
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4953385
19 June 2014
Spot Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4894037
17 June 2014
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4900645
15 May 2014
Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4858769
15 May 2014
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4866061
29 March 2014
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4846282
19 March 2014
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4820260
12 July 2012
MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4376626
9 July 2012
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4373123
15 February 2012
Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4230461
6 February 2012
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4241258
18 September 2011
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4149028
3 August 2011
Periodic Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4103878
18 July 2011
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4086764
19 February 2011
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3949849
17 December 2010
Periodic Inspection · Spot Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3912346
29 November 2010
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3907602
30 October 2010
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3881193
26 October 2010
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3877783
10 October 2010
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3868109
17 September 2010
Periodic Inspection · Spot Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3851602
8 February 2010
MTSA Verification · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3676893
14 December 2009
Periodic Inspection · MTSA Verification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3649774
10 December 2009
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3648131
10 May 2009
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3472430
30 March 2009
Spot Check · Periodic Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3443063
2 January 2009
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3388571
15 December 2008
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3381810
11 December 2008
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3385920
10 December 2008
Spot Check · Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3377373
2 December 2008
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3374058
28 November 2008
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3371746
2 October 2008
Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3336974
15 July 2008
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3270333
19 March 2008
COI Inspection · Internal Structural Exam · Hull Examination · MTSA Verification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3167356
27 February 2008
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3154779
10 October 2007
MTSA Verification · Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3071928
7 October 2007
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3076176
4 April 2007
MTSA Verification · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2891563
4 February 2007
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2867074
1 February 2007
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2868226
13 October 2006
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2799980
2 October 2006
Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2791601
30 September 2006
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2798694
24 April 2006
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2634544
24 January 2006
MTSA Verification · Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2572108
10 November 2005
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2532398
12 October 2005
MTSA Verification · Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2512969
13 July 2005
MTSA Verification
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2435930
9 July 2005
MTSA Verification
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2435760
4 March 2005
MTSA Verification · COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2300508
23 September 2004
Periodic Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2270175
18 March 2004
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2022229
8 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1961092
23 October 2003
Deficiency Check · Damage Survey
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1934564
23 August 2003
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1919800
4 June 2003
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1809781
2 May 2002
Initial Certification
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1693385
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 July 2026
Resolved
Doors in “A” Class bulkheads shall meet the following requirements:Doors shall have a latch with a minimum throw of 3/4 inch which can be operated from either side of the door. Class a door on A-end of passenger lounge did not latch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2026
Resolved 22 July 2026
Resolution: A-End Passenger Lounge Door latch is repaired. Maintenance cleaned, inspected and lubricated latch assembly and door hinges. Test Sat. Latch is functioning properly.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 15 July 2026
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Damage present to gel coat on keel of rescue boat at stowage cradle location.
Investigate if only gel coat damage or goes into fiberglass. Swapping of spare rescue boat authorized with notification to MSD Nags Head.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2026
Resolved 27 July 2026
Resolution: Epoxy was applied to the bottom of the hull. It has been sanded and repainted.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 July 2026
Resolved
All emergency lights shall be marked with a letter “E” at least 1/2 inch high. Emergency lights on 01 deck not properly marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2026
Resolved 1 August 2026
Resolution: Received notification that emergency lights have been properly labeled on the 01 deck
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 July 2026
Resolved
Each lifejacket container must be marked in block capital letters and numbers with the quantity, identity, and size of the equipment stowed inside the container. Lifejackets stowed on bridge were not in the marked container.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2026
Resolved 3 August 2026
Resolution: Lifejackets are now stored in the proper location
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 26 March 2026
Resolved
For nontank vessels with an oil capacity of 250 barrels or greater, a vessel owner or operator must comply with the VRP exercise requirements of 33 CFR 155.1060. A vessel owner or operator required to have a response plan shall conduct quarterly qualified individual notification exercises. The quarterly qualified individual notification exercises were not conducted. Conduct quarterly qualified individual notification exercises as required.
Action required: 10 - Deficiency Rectified
Resolved 26 March 2026
Resolution: Completed during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 January 2026
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Marine Vessel Rules (incorporated by reference, see § 58.03-1), except as otherwise provided by this subchapter. During the test of the emergency generator, it failed to automatically come on line. Complete repairs as needed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2026
Resolution: One of the phases had a blown fuse, not allowing the controls to sense power and shift the load. The fuse was replaced, and the generator worked as it should.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 December 2025
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Marine Vessel Rules (incorporated by reference, see § 58.03-1), except as otherwise provided by this subchapter. The keel cooler boot of the A end main engine ruptured. Make permanent repairs to the keel coolant boot of the A end maine engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2025
Resolution: Received objective evidence that a new keel coolant boot was installed.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 11 December 2025
Resolved
Fire control. (1) Fire control diagram showing location and type of all required fire-screen insulation, including main fire zone and subdivisions, stairway and elevator enclosures, control space enclosures, etc., and type of all doors in such subdivisions and enclosures.(2) Comprehensive typical details of fire-screen insulation of both vertical and horizontal surfaces, including deck coverings where used, keyed by reference numbers to the “fire control diagram”.(3) Ventilation diagram including dampers and other fire control features.(4) Alarm systems.(5) Detecting systems.(6) Extinguishing systems, including fire main, carbon dioxide, clean agent, foam, and sprinkling systems.(7) Supervised Patrol Route. MI observed the vessel did not have fire control plan onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2025
Resolved 2 January 2026
Resolution: Fire control plan is now on board
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 11 December 2025
Resolved
An emergency means of communication required by this subpart must—(1) Be comprised of either fixed or portable equipment; and(2) Provide common talking means
of two-way voice communication and calling among the navigating bridge, emergency control stations, muster stations, embarkation stations, and other strategic positions listed in § 113.30-5. MI observed that the A end ringer is not working as designed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2026
Resolved 2 January 2026
Resolution: Sound powered phone is repaired
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 2 October 2025
Resolved
Means shall be provided for closing all openings to the space protected from outside such space. In this respect, relatively tight doors, shutters, or dampers shall be provided for openings in the lower portion of the space. The construction shall be such that openings in the upper portion of the space can be closed off either by permanently installed means or by the use of canvas or other material which is normally carried by the vessel. MI observed the door gasket not sealing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2025
Resolved 14 October 2025
Resolution: Door gaskets were replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 July 2025
Resolved
The material, design, construction, and workmanship, and arrangement of main propulsion machinery and of each auxilary, directly connected to the engine... must be at least equivalent to the standards established by the ABS Steel Vessel Rules.
A- end main engine lost power temporarily.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 2 July 2025
Resolution: The engine speed sensor was replaced and all tachometers are functioning properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 February 2024
Resolved
Remote shut-off valve for the emergency bilge pump piping for the B-end forepeak suction is inoperable due to a snapped reach rod. Conduct permanent repairs to the satisfaction of the attending marine inspector, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2024
Resolution: Received photographic evidence of newly installed reach rod. Evidence attached.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 February 2024
Resolved
Passenger lounge door on the 01 deck (A-end) will not close due to excess paint on door jam. Conduct repairs to ensure space is weather tight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2024
Resolved 26 March 2024
Resolution: Inspected operation of A-end pax lounge door; sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 February 2024
Resolved
Life jacket stowage number on 01 deck IVO passenger lounge is peeling. Relabel stowage compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2024
Resolved 26 March 2024
Resolution: Inspected 01 deck lifejacket storage locker markings; sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 February 2024
Resolved
Each self-propelled vessel must have at least two electric generating sources in addition to the emergency generator required by 112 of this chapter. The #1 Genset of the W. STANFORD WHITE is inoperable due to a leak on the vessel's keel cooler. Effect permanent repairs to the satisfaction of the attending Marine Inspector, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 February 2024
Resolved 26 February 2024
Resolution: Received photographic evidence of repaired keel cooler and captain's attestaation.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 November 2023
Resolved
Bulkheads or decks of the "A" Class shall... be capable of preventing the passage of smoke or flame for 1 hour. The gasket has failed on the EDG space sliding door.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2023
Resolved 22 December 2023
Resolution: Gasket on EDG door replaced. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 30 November 2023
Resolved
Each machinery space must be ventilated to ensure that,...an adequate supply of air is maintained for the operation of the machinery and the safety, efficiency, and comfort of the crew. MSD space fan is OOC.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2023
Resolved 22 December 2023
Resolution: Fan in MSD space repaired. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 April 2023
Resolved
Vessel's A-end main engine would not go in reverse power. Complete permanent repairs to prior to carriage of passengers. Vessel's repairs must be cleared by a marine inspector from DD Nags Head IAW 46CFR77.01.
Please conduct sea trials after repair prior to operations in addition, please provide the Masters attestation to the repairs and sea trial, and his/her comfort in running the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2023
Resolution: Cause identified as broken control shaft in Voith steering linkage. Connection welded. Sea Trials conducted with Captains attestation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 March 2023
Resolved
Voith unit losing oil into the water. Vessel may transit to yard for repairs. All repairs are to be made prior to carrying passenger and prior to using voith unit due to pollution potential. All repairs are to be made to satisfaction of attending [name withheld] 46CFR71.25-35
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2023
Resolved 17 March 2023
Resolution: NCDOT technicians overhauled the vessel's B End Voith, replaced appropriate parts and re-installed the unit. QA oversight was performed during the entire overhaul.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2023
Resolved
Submit updated PSTPs to MSC for review and approval. IAW 46CFR61
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2023
Resolved 31 March 2023
Resolution: NCDOT QA has submitted updated PSTPs to MSC for review.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 24 February 2023
Resolved
Radiotelephony Certificate and Bridge-to-Bridge Radiotelephony certificate are expired. IAW 47CFR80
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2023
Resolved 28 February 2023
Resolution: Received email from [name withheld] with updated FCC Communication Act Safety Radiotelephony Certificate and FCC Vessel Bridge-To-Bridge Radiotelephony Certificate
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 May 2022
Resolved
Operator reported that the B end voith unit started making a loud knocking noise and they took the unit off line to prevent further damage during their trip back to Hatteras. Provide causal factors attributing to cause and corrective actions taking to rectify. Vessel must be cleared by a marine inspector from this office before returning to service.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2022
Resolved 17 May 2022
Resolution: Deficeincy cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 April 2022
Resolved
The main steering gear must be operable from the pilothouse by means of mechanical, hydraulic, electrical or other means accepted by the Commanding Officer, Marine Safety Center. Vessel's master reported that the steering lever in the pilothouse is causing the vessel to "pull," but is still able to maintain control of the vessel. Make repairs and prove proper operation of the steering system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2022
Resolved 11 April 2022
Resolution: Shoreside maintenance recalibrated steering levers and conducted satisfactory sea trials.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 17 March 2022
Resolved
Rescue boat grab handle on hull port forward broken in half replace IAW 46CFR71.25-20.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2022
Resolved 21 March 2022
Resolution: New handle installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 March 2022
Resolved
A-end MDE oil differential pressure hose damaged replace IAW 46CFR71.25-35.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2022
Resolved 21 March 2022
Resolution: New approved hose installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 17 March 2022
Resolved
Gasket on A & B end forward peak is leaking, replace with new IAW 46CFR71.25-25.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2022
Resolved 21 March 2022
Resolution: New gasket installed and tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 February 2022
Resolved
Vessel crew reporting engine knock on A-end MDE, believed to be hydraulic electronic unit injection system. NCDOT to verify HEUI system is cause/damaged equipment and make repairs to the satisfaction of the attending Marine Inspector iaw 46 CFR 58.05-1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2022
Resolution: Engine knock rectified, HEUI pump replaced and cam shaft gears replaced and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 January 2022
Resolved
Make permanent repairs to A End MDE and conduct satisfactory sea trials in the presence of a Coast Guard Marine Inspector IAW 46CFR50.05-10.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2022
Resolution: MI reviewed tech report, CAPT statement and crew sea trials report. A new actuator valve and wiring harness was installed and tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 January 2022
Resolved
Identify cause for engine casualty on A-End MDE, make permanent repairs and conduct sea trials prior to carrying passengers, IAW 46CFR50.05-10.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2022
Resolution: Received tech report attesting to repairs, sea trials conducted sat.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 December 2021
Resolved
Vessel liferafts are not properly secured to the vessel. liferaft cradles are also loose. Mount on liferaft #3 is loose. Life raft #5 has wasted bolt. Liferaft #5 and #22 have loose straps (fixed on spot). Spacers are missing on all liferaft mounts. Repair/modify in accordance with 46CFR70.28-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2022
Resolved 13 January 2022
Resolution: Replaced and adjusted nylon straps as required. Replaced missing rubber spacers. Removed wasted pedestal bolts on #1, #3 and #5 and replaced with new bolts, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 December 2021
Resolved
Various cracks found through out liferaft mounts. Will monitor on future inspections. Will be repaired in accordance with 46CFR70.28-1 during drydock in May 2022
Action required: 705 - Other - as specified
Resolved 20 February 2023
Resolution: All brackets welded and visually inspected SAT with raft #2 bracket needing additional weldment. All repairs are SAT with no cracks.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 16 December 2021
Resolved
Cracked ore on rescue boat. Repair/replace in accordance with 46CFR70.28-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2022
Resolved 13 January 2022
Resolution: Replaced ore, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 December 2021
Resolved
B end voith unit has various hydraulic oil leaks at fittings. Repair in accordance with 46CFR70.20-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2022
Resolved 13 January 2022
Resolution: Fabricated a new gasket for access plate on top of Voith unit, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 December 2021
Resolved
Fuel tank supply valve is leaking. Repair in accordance with 46CFR70.20-1
Action required: 10 - Deficiency Rectified
Due 16 December 2021
Resolved 16 December 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 December 2021
Resolved
#5 fixed CO2 bottle found loose. Repair in accordance with 46CFR76.15-20
Action required: 10 - Deficiency Rectified
Due 16 December 2021
Resolved 16 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 3 November 2021
Resolved
Rescue boat davit wire is corroded and beginning to deteriorate. replace wire and conduct weight test in accordance with 46CFR199.45(b)(1)
Action required: 17 - Rectify deficiencies prior to departure
Due 3 November 2021
Resolved 3 November 2021
Resolution: Wire replaced and tested, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 3 November 2021
Resolved
Watertight Door on Main Deck leading to engine room is miss aligned with open/close indicator. Indicator is not registering alarm. Ensure proper alignment and indicator works in accordance with 46CFR170.270(a).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2021
Resolved 4 November 2021
Resolution: Door serviced and dogs properly aligned, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 3 November 2021
Resolved
Vessel's public restroom doors do not fasten, createing a hazard for passengers/crew. Ensure door latches/secures in accordance with 46CFR71.25-40
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2021
Resolved 15 November 2021
Resolution: Latches and closers replaced on head doors, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 November 2021
Resolved
Remove new Co2 fire extinguishers that do not meet updated standards in accordance with 46CFR71.25-20.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2021
Resolved 4 November 2021
Resolution: UNSAT fire extinguishers removed from the vessel.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 November 2021
Resolved
Fixed Co2 bottles are loose in mounting brackets. Tighten to prevent shifting in accordance with 46CFR71.25-20.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2021
Resolved 4 November 2021
Resolution: Tightened brackets for Co2 cylinder, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 November 2021
Resolved
A-end voith space emergency lighting is inoperable. Replace/repair to ensure proper operation in accordance with 46CFR111.75-15(c)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2021
Resolved 16 November 2021
Resolution: Emergency lighting repaired, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 November 2021
Resolved
A-end engine room hand rail is missing course. replace with new/existing in accordance with 46CFR72.40-20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2021
Resolved 4 November 2021
Resolution: Course replaced, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 November 2021
Resolved
Lifering throwline is deteriorated and lifering waterlight line is deteriorated. Both on portside main deck. Replace with new in accordance with 46CFR199.70(a)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2021
Resolved 16 November 2021
Resolution: Lifering throw lines replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 November 2021
Resolved
Main engine control room alarm panel has fault on blank causing false alarm replace circuit to prevent repeat in accordance with 46CFR61.40-6
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2021
Resolved 16 November 2021
Resolution: Alarm card reconfigured for blank alarm point. No nuisance alarms, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 November 2021
Resolved
B-end ladder leading from main deck to 01 deck deteriorated at connection. repair to ensure properly connected, crop and renew in accordance with 46CFR71.25-10
Action required: 17 - Rectify deficiencies prior to departure
Due 3 November 2021
Resolved 3 November 2021
Resolution: Connection repaired with weld, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 September 2021
Resolved
B-end voith unit has high oil temp and bearing temp. NCDOT removed vsl from service to rebuild voith unit with CG oversite.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 November 2021
Resolution: Voith unit rebuild and tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2021
Resolved
Replace leaking shaft input seal on A and B end voith unit iaw 46 CFR 46 CFR 58.05-1.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2021
Resolution: During sea trails shaft seal was properly adjusted and installed with no issues. Test SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 June 2021
Resolved
Replace expired batteries on lifering lights iaw 46 CFR 199.211(b).
Action required: 10 - Deficiency Rectified
Resolved 18 June 2021
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 March 2021
Resolved
Vessel is unable to deploy lifeboat for MOB recovery due to davit seized. Repair and test underway prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2021
Resolution: Rescue boat davit repaired; op test sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 March 2021
Resolved
CO2 system is not operating when using remote activation. Vessel crew and NCDOT were able to identify cause as failed/deteriorated O-ring/seals on the time delay. Parts replaced with new, tested sat.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 18 March 2021
Resolution: Corrected and tested sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 March 2021
Resolved
Vessels main engines are giving both low lube oil and overspeed alarm during testing of low lube oil alarm. System/engines sill provide audible/visual alarm and shut engine down. Identify cause for additional (overspeed) alarm in EOS and rectify.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 24 March 2021
Resolution: Alarm circuits have been separated; op test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2021
Resolved
Replace petcock valves with valve plug on lube oil system for MDE and generators.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 24 March 2021
Resolution: All petcock valves on low lube oil test fittings have been replaced with plugs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 March 2021
Resolved
Troubleshoot and repair sound powered phone on Bravo end of vessel. Phone lines were miss matched and did not call selected line.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 24 March 2021
Resolution: Identified problem as shifted identification plate; circuits tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 August 2020
Resolved
Voith unit on both A and B ends have minor leaks and deteriorated fastener bolts. Replace deteriorated bolts and mitigate water ingress iaw 46 CFR 72.01-15.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2020
Resolved 1 September 2020
Resolution: Vessel replaced the bolts on the Voith Units and corrected the water ingress problem.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 28 August 2020
Resolved
Weathertight hatch at FR 44A is leaking. Tighten/Replace to prevent iaw 46 CFR 72.30-1.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2020
Resolved 1 September 2020
Resolution: Weathertight hatch was adjusted and tested satisfactory.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 August 2020
Resolved
Ensure all portable fire extinguishers are weighed and recordings are accurate iaw NFPA 10 and 46 CFR 76.05-25 / 76.01-2.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2020
Resolved 1 September 2020
Resolution: Vessel provided documentation for weighing and recording the portable fire extinguishers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 August 2020
Resolved
Provide high temp alarm verification and calibration certificate for Calibrator MTC 320-A cal.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2020
Resolved 1 September 2020
Resolution: Vessel provided High Temp Alarm Verification and Calibration Certificate as required.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 28 August 2020
Resolved
Sound powered phone on "A" End main deck is not working properly, repair iaw 46 CFR 78.35-1.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2020
Resolved 1 September 2020
Resolution: Vessel repaired "A-End" sound powered phone and tested satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 March 2020
Resolved
Each credentialed crewmember must become familiar with the relevant characteristics of the vessel appropriate to his or her duties and responsibilities prior to assuming those duties and responsibilites. Vessel engineers present for the Certificate of Inspection were unfamiliar with bilge suction configuration.
Action required: 10 - Deficiency Rectified
Resolved 18 March 2020
Resolution: Corrected on the spot.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 18 March 2020
Resolved
Drills, musters, and training sessions shall be properly logged IAW 46 CFR 199.180(h).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2020
Resolved 6 April 2020
Resolution: All drills now properly logged.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 March 2020
Resolved
Number one bilge pump power supply is inoperable.
Action required: 10 - Deficiency Rectified
Resolved 18 March 2020
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 March 2020
Resolved
Properly configure CO2 fixed system to comply with onboard diagram. Currently valve release is after ventilation shutdown pressure switch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2020
Resolved 6 April 2020
Resolution: CO2 system now properly configured.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 12 February 2020
Resolved
During dockside testing the rescue boat davit accumulator bladder ruptured. Replace accumulator bladder and test davit.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 February 2020
Resolved 13 February 2020
Resolution: A new accumulator was installed; op test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 December 2019
Resolved
Steering system does not respond to helm commands correctly. Recalibrate system and prove proper operation.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 December 2019
Resolved 20 December 2019
Resolution: Steering pump controls were recalibrated and vessel conducted a sea trial with no issues and failure could not be repeated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 November 2019
Resolved
Both local digital displays at the A and B voith units read ahead when the vessel is traveling astern and read astern when the vessel is traveling ahead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2019
Resolved 13 December 2019
Resolution: Voith units display now reading correctly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2019
Resolved
Found A/C cooling water discharge pipe leaking iwo ovbd check valve. Repair leak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 3 October 2019
Resolution: A new pipe nipple has been installed; op test sat.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 19 September 2019
Resolved
Found control oil pressure alarm constantly active/ inop. Repair alarm circuit; gauges reflect actual pressure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 3 October 2019
Resolution: The alarm circuits have been adjusted; op test sat.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 19 September 2019
Resolved
Upon entering the sewage space a significant vacuum was observed and both CG Marine Inspector's gas detectors alarmed for low O2 levels; the spaces vent fan seems to be exhausting more air than the vents can keep up with causing a negative pressure environment. Identify and repair condition; ensure crew safety measures are in place while working to correct condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2019
Resolved 3 October 2019
Resolution: Fan has been re-wired as a supply fan iaw vessel plans; op test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 1 August 2018
Resolved
Identified area of minor damage on fiberglass rescue boat and approved request for repair of gel coast ONLY to be conducted by NCDOT Hatteras Field Maintenance Shop Supervisor in accordance with manufacturer (Fassmer) repair instructions. Provide proof that repair has been examined and assessed for future repairs by authorized repair facility within 30 days.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 27 November 2018
Resolution: Verified proper fiberglass repairs were completed and rub rail installed by certified repair facility IAW manufacturers specifications.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 March 2018
Resolved
Found incorrect batteries installed in both floating waterlights. Install correct batteries.
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 28 March 2018
Resolution: Installed correct batteries.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 March 2018
Resolved
Found the B-end masthead and A-end stern lamps out. Repair navigation lights.
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 28 March 2018
Resolution: Repaired navigation lights.
Engineering › Fuel Oil Service System › Valve
Issued 22 March 2018
Resolved
Found the B-end remote fuel shut-off valve leaking at the packing gland. Adjust or replace valve.
Action required: 705 - Other - as specified
Due 21 April 2018
Resolved 18 April 2018
Resolution: Valve was properly repaired.
Communications › Alarms/Indicators › High Water Alarm
Issued 22 March 2018
Resolved
Unable to test MDE high J/W temp alarms. Prove proper operation of high temp alarm.
Action required: 705 - Other - as specified
Due 21 April 2018
Resolved 18 April 2018
Resolution: Alarms were tested IAW PSTPs.
Construction/Loadline › Structures › Door
Issued 21 September 2017
Resolved
Found the EOS door handle/latch missing. Install door handle.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 October 2017
Resolved 5 October 2017
Resolution: Installed new door handle/latch.
Engineering › Non-conventional Propulsion/Steering › Base (cycloidal)
Issued 13 August 2017
Resolved
Vessel suffered a loss of voith control system 1. Complete repairs to the voith control system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2017
Resolved 16 August 2017
Resolution: A new battery charger and batteries were installed; all sat.
Accommodation/Occupational Safety › Ventilation › General
Issued 27 July 2017
Resolved
Found the engine room ventilation supply fan inoperable. Repair/ replace fan.
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 10 August 2017
Resolution: A new E/R ventilation supply fan has been installed.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 9 December 2015
Resolved
Vessel's "B-end" MDE is hunting at all RPM levels excessively. Repair and prove proper operation of "B-end" MDE to the satisfaction of the attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 16 December 2015
Resolution: NCDOT maintenance personnel replaced the B-end MDE's fuel injectors and proved proper operation to the attending CG Marine Inspector.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 21 August 2014
Resolved
NCDOT is required to develop a plan for the installation of required emergency lighting for rescue boat launching station.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 September 2014
Resolved 22 October 2014
Resolution: E lighting at and around this area meets the intent of the requirement and cleared.
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 15 February 2012
Resolved
Repair passenger accommodation space heater and pilot hosue heater.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2012
Resolved 9 May 2012
Engineering › Fuel Oil Service System › Valve
Issued 3 August 2011
Resolved
Address procedures for prevention of blocking fuel shut-off valves while loaded.
Action required: 705 - Other - as specified
Due 3 September 2011
Resolved 3 August 2011
Resolution: A memo was written up stating the procedures to prevention blocking of the fuel shut off valves. Memo was to be sent to all Captains and posted at the Office for wide
Lifesaving › Rescue Boat › Propulsion Engine
Issued 3 August 2011
Resolved
Provide kill-switch lanyard for rescue boat.
Action required: 705 - Other - as specified
Due 3 September 2011
Resolved 3 August 2011
Resolution: A kill-switch lanyard for the rescue boat was provided.
Engineering › Fuel Oil Service System › Hose
Issued 17 December 2010
Resolved
Make Repairs to Leaks on #2 Ship Service Generator, #1 and #2 Fuel Nozzle.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2010
Deck/Cargo › Cargo Stowage › General
Issued 17 December 2010
Resolved
Remove all flamables from Engine Room Lockers.
Due 17 December 2010
Resolved 17 December 2010
Resolution: Items removed from Engine Room Lockers.
Engineering › Lubricating Oil Storage/Transfer System › Vent Pipe
Issued 17 September 2010
Resolved
Install flame screen in E/R oil tank vent pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2010
Resolved 19 September 2010
Resolution: Installed flame screens on oil tank vent.
Engineering › Fuel Oil Service System › Valve
Issued 17 September 2010
Resolved
Install steel fuel valves as per Sector NC letter at next yard period or drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2011
Resolved 2 May 2011
Resolution: Steel valves installed, Hydrostatic test completed, found all satisfactory.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 17 September 2010
Resolved
Repair lavatory drain valves in "A" end aux. space IVO mufflers
Action required: 705 - Other - as specified
Due 24 September 2010
Resolved 19 September 2010
Resolution: Drain was tightened and is leak free.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 17 September 2010
Resolved
Fix seat backs for 03 Passenger seats in 01 deck passenger lounge
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2010
Resolved 19 September 2010
Resolution: New sea backs were installed.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 30 March 2009
Resolved
Renew COFR (expired)
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 27 April 2009
Stability › Weathertight Integrity › General
Issued 30 March 2009
Resolved
Repair 01 deck doors (not closing).
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 27 April 2009
Engineering › Fuel Oil Service System › Hose
Issued 30 March 2009
Resolved
Install a suitable, J standard, fuel oil flex hose (x4).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2009
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 30 March 2009
Resolved
Install a suitable plug for oil tank.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2009
Stability › Watertight Integrity › General
Issued 30 March 2009
Resolved
Adjust watertight doors from the main deck down (28A, 12B, and 28B)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2009
Stability › Weathertight Integrity › General
Issued 10 December 2008
Resolved
Repair "A" end lobby weather tight door.
Action required: 705 - Other - as specified
Due 17 December 2008
Resolved 16 December 2008
Resolution: A end lobby door has been adjusted and now fully closes without slamming.
Electrical › Electric Generation Source (service) › Switch
Issued 10 December 2008
Resolved
Renew fuel pressure switch, "B" ship service generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2008
Resolved 16 December 2008
Resolution: Fuel pressure switch renewed.
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 December 2008
Resolved
Remote fuel shut-down on "B" end leaks, repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2008
Resolved 16 December 2008
Resolution: B end remote fuel shut-down has been re-packed, checked operation with no leaks.
Stability › Watertight Integrity › General
Issued 5 October 2006
Resolved
Adjust engine room WTD (main deck access).
Due 6 October 2006
Resolved 13 October 2006
Communications › Alarms/Indicators › High Water Alarm
Issued 12 October 2005
Resolved
Provide approved automation test procedures
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 November 2005
Resolved 14 November 2005
Resolution: Provided.
Navigation › Piloting/Steering › Marine Charts
Issued 12 October 2005
Resolved
Provide updated navigation publications IAW 46 CFR 78.05-5
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 November 2005
Resolved 10 November 2005
Resolution: Provided
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 12 October 2005
Resolved
Secure microwave and refrigerator for sea.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 November 2005
Resolved 10 November 2005
Fire Fighting › Nozzles › Condition
Issued 12 October 2005
Resolved
Renew captive chains IWO fire nozzles.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 November 2005
Resolved 13 October 2005
Resolution: Installed.
Construction/Loadline › Structures › Machinery Space Opening
Issued 12 October 2005
Resolved
Adjust watertight door IWO engine room main deck access.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2005
Resolved 13 October 2005
Resolution: Adjusted.
Engineering › Fuel Oil Service System › Pump
Issued 12 October 2005
Resolved
Repair fuel oil leak IWO emergency generator fuel oil transfer pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2005
Resolved 13 October 2005
Resolution: Repaired.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 12 October 2005
Resolved
Provide complete instructions IWO local engine room CO2 system.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 November 2005
Resolved 10 November 2005
Resolution: Installed.
Lifesaving › Rescue Boat Equipment › Painter
Issued 12 October 2005
Resolved
Install a painter cleat aboard the vessel in a suitable location (providing for proper fairlead while the rescue boat is along side) and provide proper rescue boat equipment IAW 46 CFR table 199.620(j) to include: bailer, boathook, painter, and towline.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 November 2005
Resolved 6 April 2006
Resolution: All equipment was installed.
Documentation › Certificates/Documents › FCC SSL
Issued 23 September 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 October 2004
Resolved 7 October 2004
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Construction/Loadline › Structures › Door
Issued 23 September 2004
Resolved
DOOR LEADING TO PASSENGER LOUNGE WOULD NOT CLOSE COMPLETELY.
Action required: 705 - Other - as specified
Due 23 October 2004
Resolved 7 October 2004
Electrical › Lighting (emergency) › Lighting Fixture
Issued 23 September 2004
Resolved
BURNED OUT BULB ON EXIT SIGN IN PASSENGER LOUNGE.
Action required: 705 - Other - as specified
Due 23 October 2004
Resolved 7 October 2004
Resolution: REPLACED BULB.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 23 September 2004
Resolved
CORROSION ON TOPS OF ALL EXTERIOR PORTABLE FIRE EXTINGUISHERS ON MAIN DECK.
Action required: 705 - Other - as specified
Due 23 October 2004
Resolved 7 October 2004
Resolution: REPLACED ALL EXTERIOR MAIN DECK PORTABLE CO2 FIRE EXTINGUISHERS.
Operations/Management › Drills/Instruction › Fire
Issued 23 September 2004
Resolved
POOR EXECUTION OF FIRE DRILL
Due 23 October 2004
Resolved 7 October 2004
Resolution: Conducted additional trng which was logged in the ships log.
Operations/Management › Drills/Instruction › Fire
Issued 23 September 2004
Resolved
POOR EXECUTION OF FIRE DRILL
Due 23 October 2004
Resolved 7 October 2004
Resolution: Conducted additional trng which was logged in the ships log.
Engineering › Steering Gear System
Issued 23 October 2003
Resolved
Repair steering systems prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 October 2003
Resolved 23 October 2003