ROANOKE

ROANOKE is a 1994 passenger vessel (inspected). The Coast Guard has recorded 151 inspections since 1994, most recently in March 2026, along with 100 deficiencies and 60 casualty investigations between 2005 and 2022.

Records from 1994 to 2026. Most recent: inspection, 12 March 2026.

Built
1994
Last inspected
12 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8645258 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDP6840
393663
Flag
UNITED STATES
368376280
Maury page id
psix-393663

Inspections, by type

…with no type recorded51
Years with a record 27 calendar years (1994–2026)
The 151 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)143.6 ft × 34.0 ft × 8.2 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)143.6 ft × 34.0 ft × 8.2 ft
ITC tonnagegross 270 / net 86
BuilderSTEINER SHIPYARD INC · BAYOU LA BATRE, AL, UNITED STATES · built 1994
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBRISTOL, RI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it270 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
86 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP6840MMSI 368376280 · active · compulsorily equipped · granted 29 June 2024, expires 29 June 2034
WCE2420MMSI 366921050 · expired · compulsorily equipped · granted 7 January 2014, cancelled 27 April 2024
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ALBEMARLE Towing Vessel · MISLE 149837 · 30 January 2016 · activity 5807239W STANFORD WHITE Passenger (Inspected) · MISLE 594163 · 17 June 2014 · activity 4900645CROATOAN Passenger (Inspected) · MISLE 603211 · 17 June 2014 · activity 4900645BUXTON, JR. Towing Vessel · MISLE 452828 · 26 January 2011 · activity 3933281

Inspection history · 151

12 March 2026 Drydock Extension
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8325031
9 December 2025 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8279903
23 December 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8050439
18 July 2024 Deadweight Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7954071
20 July 2023 Administrative Inspection · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7740453
11 August 2022 Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7530014
11 July 2022 Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7504010
10 July 2022 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7548169
26 May 2022 Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7460117
30 April 2022 Deficiency Check · Special
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7442237
30 April 2022 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7447394
6 April 2022 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7428591
5 April 2022 Special · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7425695
9 February 2022 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7390784
29 October 2021 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7341831
5 September 2021 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7304819
5 September 2021 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7308590
19 August 2021 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7288187
27 May 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7208680
27 May 2021 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7238431
27 May 2021 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7316693
20 May 2021 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7201574
16 May 2021 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7198472
16 May 2021 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7201896
3 May 2021 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7188359
3 May 2021 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7189418
22 February 2021 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7142876
10 February 2021 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7142662
7 February 2021 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7136983
7 February 2021 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7142835
21 December 2020 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7158656
26 November 2020 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7119290
13 November 2020 MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7093369
24 February 2020 Examination of Repairs · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6915914
30 October 2019 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6844565
22 July 2019 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6756801
16 June 2019 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6933209
4 June 2019 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6706461
1 June 2019 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6706607
10 April 2019 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6659277
15 January 2019 Deficiency Check · Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6610452
24 October 2018 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6553993
4 October 2018 Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6563859
2 October 2018 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6555010
25 July 2018 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6497894
20 July 2018 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6485132
13 April 2018 Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6391062
1 February 2018 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6334743
16 November 2017 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6307555
10 August 2017 Re-Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6234386
2 July 2017 Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6199407
20 May 2017 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6152488
21 April 2017 COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6129798
28 November 2016 Internal Structural Exam · Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6058962
29 September 2016 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6014531
12 September 2016 Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5999601
8 August 2016 Re-Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5968250
29 July 2016 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5959162
28 July 2016 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5956094
28 April 2016 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5864057
20 February 2016 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5820546
31 January 2016 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5807372
30 January 2016 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5807239
15 January 2016 Special · Deficiency Check · Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5799690
18 November 2015 Deficiency Check · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5765290
9 November 2015 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5761492
9 November 2015 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5761917
21 October 2015 Examination of Repairs
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5757123
16 October 2015 Examination of Repairs
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5760797
22 September 2015 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5727003
3 August 2015 MTSA Verification · Special · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5205404
20 August 2014 Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4961625
19 August 2014 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4961193
19 June 2014 Spot Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4893980
17 June 2014 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4900645
22 May 2014 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4866075
1 May 2014 Deficiency Check · Examination of Repairs · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4836536
26 July 2012 Periodic Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4390835
11 June 2012 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4341523
10 June 2012 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4340465
9 May 2012 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4307694
7 May 2012 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4305209
5 May 2012 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4303341
4 May 2012 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4303332
3 May 2012 COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4288071
28 February 2012 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4254075
27 February 2012 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4252343
26 February 2012 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4251597
16 February 2012 Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4246121
12 December 2011 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4206771
10 December 2011 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4206762
17 August 2011 Periodic Inspection · Examination of Repairs · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4131708
27 July 2011 Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4095705
13 July 2011 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4080896
24 February 2011 Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3951439
11 February 2011 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3943606
28 January 2011 Spot Check · Periodic Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3934376
26 January 2011 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3933281
10 January 2011 Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3924159
5 November 2010 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3887430
19 October 2010 Spot Check · Periodic Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3872990
9 March 2010 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3693215
24 February 2010 Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3685213
10 February 2010 Periodic Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3677932
10 February 2010 Spot Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3680361
29 January 2009 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3401869
23 January 2009 MTSA Verification · Initial Certification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3398800
7 October 2008 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3340752
3 September 2008 DAPI Audit
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 3316732
16 July 2008 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3270776
21 May 2008 Spot Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3214268
14 February 2008 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3147978
18 December 2007 MTSA Verification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3118000
10 April 2007 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2905412
29 September 2006 Hull Examination · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2789951
17 September 2006 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2787178
26 July 2006 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2727618
11 July 2006 Spot Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2716922
7 June 2006 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2677736
6 September 2005 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2486252
24 July 2005 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2452675
9 July 2005 MTSA Verification
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2435814
7 July 2005 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2423185
11 December 2004 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2259767
8 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1961101
6 June 1997 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1109580
20 March 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1098454
13 January 1997 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1099015
15 October 1996 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1157546
31 July 1996 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1086159
23 June 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 122172
19 June 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2946
9 May 1996 Re-Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1380507
17 January 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 56863
16 January 1996 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1187881
18 October 1995 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1181538
14 July 1995 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1183279
18 April 1995 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1165364
12 April 1995 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1166605
17 January 1995 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1139516
16 November 1994 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 867671
14 October 1994 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 861335
29 August 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 141344
10 August 1994 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 869677
11 July 1994 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1178000
16 June 1994 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1021273
14 June 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1325527
27 February 1994 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1163472
22 February 1994 Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1407267
19 February 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 86325
14 February 1994 Hull Examination · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 853321

Deficiency record · 100

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 July 2022 Resolved
Received report the ROANOKE has a line wrapped around the STBD prop and STBD MDE has a broken rocker arm. Make permanent repairs to the satisfaction or attending Marine Inspector. MI notified vessel master to make report to Sector Command Center. Submit CG-2692 to DD Nags Head IO.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 July 2022
Resolved 13 July 2022
Resolution: New rocker arm assy installed and tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 April 2022 Resolved
The operator reported a leak in the #2 SSDG system causing a mixture of oil in the generators lube oil system requiring it to be shutdown and change over to the #1 SSDG. Provide casual factors to causing leak and corrective actions to fix the leak. Vessel is not permitted to carry passengers until cleared by a Marine Inspector from this office.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2022
Resolution: Leak identified on transfer pump and pump was replaced in kind. Engine had an oil change and tested satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 April 2022 Resolved
Vessel #1 steering system is malfunctioning, NCDOT mechanic/electrician to troubleshoot and make repairs to the satisfaction of the Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2022
Resolution: Received objective evidence of repair and sea trials tested sat, all clear.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 November 2021 Resolved
A survey either general shall be made every time a defect is discovered. A damaged and wasted hose on the #1 SSDG air sep system. Additionally, identified two hoses on the #2 SSDG air sep that was leaking. Replace in-kind.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2021
Resolved 15 November 2021
Resolution: Received documentation proving the hoses were replaced in-kind.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 November 2021 Resolved
A survey either general shall be made every time a defect is discovered which affects the completeness of fire-fighting equipment. Marine inspector identified two (2) fire-extinguishers onboard not properly labeled per requirements of the certificate of inspection.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2021
Resolved 15 November 2021
Resolution: Received documentation proving both extinguishers were replaced with proper type.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 August 2021 Resolved
The regulations in this part provide a means to minimize the of intoxicants by merchant marine personnel and to promote a drug free and safe work enviroment. Vessel is not complaint with drug and alcohol program after DAPI conducted. Provide policy statement onboard, proper training conducted, and knowledge of DER.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2021
Resolved 8 September 2021
Resolution: DAPI policies are now onboard all vessels, the crews were educated on EAP information, designation of DER, and Masters were enrolled in training for drug awareness.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 August 2021 Resolved
Lifebuoy must be so distributed as to be readily available on each side of the vessel and as far as practicable on each side of the open deck extending to the side of the vessel. MI noted aft starboard lifebuoy dryrotted. Properly renew.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 August 2021
Resolved 27 August 2021
Resolution: Life Ring Buoy was renewed and properly marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 August 2021 Resolved
A survey shall be made everytime a defect is discovered when any important reapir or renewals are made. Oily residue found on portside amin engine outboard jacket water system. Make effective repairs.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2021
Resolution: Jacket water expansion tank drained and re-filled to notice no oily residue in sight glass.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 May 2021 Resolved
Provide anylyze report on voltage relay that was removed from #1 steering system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2021
Resolution: Completed testing to the satisfaction of the coast guard. The relay was not found defective during testing.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 May 2021 Resolved
MI was notified of #1 steering system failure while carrying passengers. Capt. reported control power loss alarm in pilot house and switched to #2 steering pump with no issues. Failure could not be repeated. Trouble shoot and repair #1 steering system.
Action required: 10 - Deficiency Rectified
Resolved 27 May 2021
Resolution: See Narritive for full details of trouble shooting. "Control Power U.V. Relay" replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 May 2021 Resolved
Properly secure CO2 discharge hose in EDG space.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 May 2021
Resolved 20 May 2021
Resolution: Hose was properly tightened
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 May 2021 Resolved
Missing one adult sized life jacket from 25 capacity stowage bin in the passenger compartment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2021
Resolved 27 May 2021
Resolution: Verified the presence of the missing adult life jacket.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 May 2021 Resolved
Pilot valve on second CO2 bottle in MSD space was loose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 May 2021
Resolution: Pilot valve was secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 May 2021 Resolved
Fuel return line on EDG was found loose.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 20 May 2021
Resolution: Return line was tightened.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 20 May 2021 Resolved
Missing hardware on portside engine room exhaust ventilation closure bolt.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 May 2021
Resolution: Hardware was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2021 Resolved
Loss of the #1 steering system and motor. Trouble shoot and determine the cause of the casualty.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2021
Resolved 17 May 2021
Resolution: Completed to the satisfaction of the Coast Guard. See AN 7198472 for details.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 May 2021 Resolved
Steering system out of calibration to port side rudder stop. Port side stops approx 6 inch prior to hitting rudder stop.
Action required: 10 - Deficiency Rectified
Resolved 3 May 2021
Resolution: Electrican adjusted angle indicator card, underway testing SAT as per CAPT statement.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 22 February 2021 Resolved
The EDG shutdown when tested for operation. Lube oil fault was indicated. Crew found three way valve was in the wrong position. Provide/create procedure, training, and sign to show proper position. To satisfaction of the marine inspection.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2021
Resolved 16 March 2021
Resolution: Label was installed for the lube oil gauge line to show different positions.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 22 February 2021 Resolved
Rescue boat fuel line is wasted/worn. Replace in-kind.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2021
Resolved 24 February 2021
Resolution: Fuel line for rescue boat was replaced.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Lashing material
Issued 22 February 2021 Resolved
Cargo nets on both ends need replacement.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 17 March 2021
Resolution: New cargo nets were properly installed.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 22 February 2021 Resolved
#5 fire station spanner wrench was missing. To be replaced by 23 February 2021.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 February 2021
Resolved 22 February 2021
Resolution: Received and accepted evidence the spanner wrench was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 February 2021 Resolved
Adult PFD's found stowed with Children's. Corrected on the spot.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 22 February 2021
Resolved 22 February 2021
Resolution: Corrected on the spot
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 22 February 2021 Resolved
During man overboard the davit required three crew to swing out for launching. Trouble shoot cause and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2021
Resolved 5 March 2021
Resolution: Davit was cleaned and lubricated. The davit is working properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 February 2021 Resolved
Received report of a vibration on port shaft. Coast Guard Sector NC has approved a one time transit to Cherry Branch for diver inspection,troubleshooting and permanent repairs. Once permanent repairs are conducted, test all related systems and contact CG MI for attendance of final operational testing prior to carrying passengers. Requested reports: CG-2692 Divers Report All repairs and testing are to be made to the satisfaction of attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2021
Resolution: Vessel replaced both port shaft, tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 February 2019 Resolved
Found E/R bilge suction valve on the aft manifold leaking by. Repair valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2019
Resolved 13 February 2019
Resolution: Valve was opened and cleaned; op test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 February 2019 Resolved
Found center E/R emergency bilge suction not operating. repair system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2019
Resolved 13 February 2019
Resolution: Operator error; op test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 20 July 2018 Resolved
Found the rescue boat davit winch corroded and in need of service or replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2018
Resolved 25 July 2018
Resolution: A new winch has been installed and tested.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 April 2018 Resolved
Found steering pump motor controllers (1 & 2) missing wire diagram inside door.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2018
Resolved 27 April 2018
Resolution: O/O installed required diagrams.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 18 April 2018 Resolved
#1 steering pump alarmed for "loss of phase." VMP entered since 27 Oct 2017.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2018
Resolved 27 April 2018
Resolution: Maintenance replaced the steering card.
Engineering › Steering Gear System › Linkage
Issued 18 April 2018 Resolved
Found worn/wasted bushing in the steering tie bar, port side. Renew bushing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2018
Resolved 27 April 2018
Resolution: New bushings were installed.
Communications › Alarms/Indicators › General Alarm
Issued 18 April 2018 Resolved
Found general alarm bell in passenger cabin inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2018
Resolution: Crew fixed general alarm; deficiency rectified on the spot.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 18 April 2018 Resolved
Found exhaust leaks on port MDE (in E/R) and stbd MDE (in void #5).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2018
Resolved 27 April 2018
Resolution: Exhaust flanges were tightened.
Construction/Loadline › Penetrations › Gasket
Issued 16 November 2017 Resolved
The stbd forward engine room and forward msd compartment bulkhead is missing unused wire run plugs/gaskets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 November 2017
Resolved 1 February 2018
Resolution: M/I verified peeenetrations had been properly sealed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 November 2017 Resolved
Port and Stbd MDE's control wiring from engine to engine control room was installed without insulation as designed by mfg. Proper insulation must be installed as approved.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 1 February 2018
Resolution: Attending M/I verified wiring was had been properly shielded during this inspection.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 November 2017 Resolved
Passenger cabin has unapproved cover over junction box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 November 2017
Resolved 1 February 2018
Resolution: Attending inspector verified deficiency had been corrected this date.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 16 November 2017 Resolved
The number seven fire extinguisher was missing the pin.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 November 2017
Resolved 1 February 2018
Resolution: Attending inspector verified deficiency had been corrected this date.
Lifesaving › Launching Appliances › Gate/Opening for Manual Launch
Issued 10 August 2017 Resolved
Found rescue boat embarkation door missing a retention device to latch the door open.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 September 2017
Resolved 24 August 2017
Resolution: Retention device has been installed.
Engineering › Steering Gear System › Solenoid Valve
Issued 12 September 2016 Resolved
Found directional control valve on #2 steering system leaking excessive amounts of hydraulic oil. This is the second CG-835 for this issue; previous CG-835 was cleared but the root problem remains.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2016
Resolution: Directional control valve and all associated o-ring were replaced. Operational test sat.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 12 September 2016 Resolved
Found MSD system not operating properly. Discharge OVBD Prohibited.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2016
Resolved 29 September 2016
Resolution: MSD system was cleaned and training was held to ensure proper operation. Sample obtained was sat.
Communications › Public Address System › Announcing Station
Issued 28 July 2016 Resolved
Found PA system inoperable. Repair PA system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2016
Resolved 29 July 2016
Resolution: Proved proper operation of PA system.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Injector (fuel injection)
Issued 28 July 2016 Resolved
Temporary repairs were made by installing a generic fuel injector line on the #1 MDE. Install the correct fuel line.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 August 2016
Resolved 8 August 2016
Resolution: Installed OEM high pressure fuel injector line.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 28 July 2016 Resolved
Found fuel oil pressure gauge leaking excessively.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2016
Resolved 29 July 2016
Resolution: Fixed leaking gauge.
Engineering › Steering Gear System › Pump
Issued 28 July 2016 Resolved
Found major hydraulic oil leak on the #2 steering pump at the DCV.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2016
Resolved 29 July 2016
Resolution: Renewed o-rings on DCV.
Engineering › Bilge Water Management System › Strainer
Issued 28 January 2016 Resolved
Prove proper operation of the bilge strainer by the side of the #1 SSG.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 February 2016
Resolved 24 February 2016
Resolution: Proper operation of this bilge strainer was demonstrated.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 28 January 2016 Resolved
Replace, as needed, missing insulation in the Machinery Space.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 February 2016
Resolved 24 February 2016
Resolution: Missing insulation was added as needed.
Communications › Audible Communications › SPD (Other)
Issued 28 January 2016 Resolved
Cord and headset missing for sound powered phone system for local throttle and clutch controls.
Action required: 705 - Other - as specified
Due 11 February 2016
Resolved 24 February 2016
Resolution: Missing SSP headset and cord was place on board as required and tested.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 18 November 2015 Resolved
Prove Proper operation of vessels Rescue Boat prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2015
Resolved 19 November 2015
Resolution: Proved proper operation as required.
Electrical › Electric Supply System (service) › Cable
Issued 21 October 2015 Resolved
Vessels Tachometer wire from the Engineering Control Console to the Pilot House was found un-shielded. Replace cable with shielded cable according to the manufactures instructions.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 November 2015
Resolved 28 January 2016
Resolution: Wire was replaced as required and walked entire lenth to prove proper installation. All testing completed on the COI renewal showed no issues with the system.
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 August 2015 Resolved
Install a bilge alarm system in accordance with 46 CFR Part 62 (Table 62.35-50) no later than the next dry-dock.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 28 November 2016
Resolution: As per CVC's letter (Serial No. 1199) vessel is not required to have bilge high level alarms.
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 11 August 2015 Resolved
Provide the vessel with Periodic Safety Test Procedures (PSTPs) for the control and monitoring systems associated with 46 CFR Part 62 in accordance with 46 CFR 61.40.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 September 2017
Resolved 12 June 2017
Resolution: PSTPs have been approved by MSC (E2-1702194).
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 1 May 2014 Resolved
Prove proper operation of fixed fire suppression system to engine room. Time delay not operating at or above 30 seconds as stamped on bottle.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2014
Resolution: Tested time delay and it went off at 42.05 seconds and considered satisfactory within reason.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 1 May 2014 Resolved
Prove proper operation of #1 SSG and required shutdowns.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2014
Resolution: #1 SSG was tested and ran for proper operation as required to include shutdowns.
Fire Fighting › Fire Main › Condition
Issued 1 May 2014 Resolved
STBD PTO fire pump is out of balance and needs to be adjusted for proper operation. Vessel has Port PTO fire pump which appears to be operating satisfactory. Minimum required is one by the regulations.
Action required: 705 - Other - as specified
Due 5 June 2014
Resolved 9 May 2014
Resolution: STBD PTO pump was replaced and tested satisfactory for service.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 1 May 2014 Resolved
Wire for red gear oil temp is not connected or operating properly. Repair as required and prove proper operation.
Action required: 705 - Other - as specified
Due 8 May 2014
Resolved 3 May 2014
Resolution: Red Gear oil temp gauge was connected and tested satisfactory.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2014 Resolved
(General) Wires need to be secured by metal bands or hangers every 24". Make adjustments as needed to wire runs not meeting this requirement.
Action required: 705 - Other - as specified
Due 8 May 2014
Resolved 3 May 2014
Resolution: Wires in all spaces appear to be secured as required.
Stability › Watertight Integrity › General
Issued 1 May 2014 Resolved
Adjust and demonstrate proper operation of all WTH's for water tightness and ease of operation.
Action required: 705 - Other - as specified
Due 8 May 2014
Resolved 3 May 2014
Resolution: Tested all WTH''s and all functioned properly as required.
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 May 2014 Resolved
Demonstrate fire and boat drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2014
Resolution: Completed satisfactory boat and fire drills as required.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 26 July 2012 Resolved
Demonstrate proper opeation of emabarkation light for IBA on STBD side
Action required: 705 - Other - as specified
Resolved 26 July 2012
Resolution: Marshall coleman called and stated light bulb was replaced and worknig properly.
Electrical › Electrical Distribution System (emergency) › Distribution Panel Bus
Issued 26 July 2012 Resolved
Provide at least one shaft cooling pump on emergency circuit and demonstrate proper operation. There are two existing defs for emergency power distribution that have an agreed repair date of Dec 2012. Allowance for this repair will be NLT Dec 2012.
Due 31 December 2012
Resolved 31 December 2012
Resolution: Shaft cooling pump placed on emergency circuit.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 26 April 2012 Resolved
Demonstrate operation of automatic discharge activation of CO2 in Bow Thruster Room. Vesel will provide live Fire Watch to monitor Bow Thruster Room while in operation till corrected.
Action required: 705 - Other - as specified
Resolved 26 July 2012
Resolution: Demonstrated proper operation
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 26 April 2012 Resolved
Relocate Fire Detector heads for CO2 Activation system in accordance with Kidde Safety Alert issued 20 April 2012.
Action required: 705 - Other - as specified
Due 25 July 2012
Resolved 26 July 2012
Resolution: Detector Heads moved and tested satisfactory.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 26 April 2012 Resolved
Review kidde Safety Alert issued 20 April 2012 and determine if proper HAD ( Heat activated devices) and being used for vessel.
Action required: 705 - Other - as specified
Resolved 26 July 2012
Electrical › Lighting (emergency) › Lighting Fixture
Issued 27 February 2012 Resolved
VSL must repair & demonstrate proper operation of the Port & STBD aft emergency embarkation lights for the inflatable life rafts.
Action required: 705 - Other - as specified
Resolved 7 March 2012
Resolution: Repaired and demonstrated.
Communications › Public Address System › Loudspeaker
Issued 16 February 2012 Resolved
Demonstrate proper operation of public address system.
Action required: 705 - Other - as specified
Due 16 March 2012
Resolved 12 March 2012
Resolution: Proper operation demonstrated.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 21 November 2011 Resolved
Repair fuel leak on Port MDE injector manifold.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2011
Resolution: Fuel leak repaired.
Electrical › Electric Generation Source (emergency) › Panelboard
Issued 21 November 2011 Resolved
Demonstrate proper operation of the audible alarm in the emergency generator room indicating low L/O pressure on the emergency generator.
Action required: 705 - Other - as specified
Due 21 December 2011
Resolved 12 December 2011
Electrical › Electric Generation Source (emergency) › Generator
Issued 21 November 2011 Resolved
Provide documentation or demonstrate compliance with requirement for emergency generator to function at full rated power when inclined to 22.5 degrees.
Action required: 705 - Other - as specified
Due 21 December 2011
Resolved 22 November 2011
Resolution: Documentation of compliance provided.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 November 2011 Resolved
Provide rubber mat in front of electrical switchboard.
Action required: 705 - Other - as specified
Due 15 December 2011
Resolved 21 November 2011
Resolution: Rubber mat provided.
Electrical › Electric Generation Source (emergency) › Generator
Issued 15 November 2011 Resolved
Demonstrate proper operation of newly installed emergency diesel generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2011
Resolution: Proper operation demonstrated.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 15 November 2011 Resolved
Repair fuel leak on Port MDE fuel pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2011
Resolution: Fuel leak repaired.
Engineering › Fuel Oil Service System › Hose
Issued 15 November 2011 Resolved
Port MDE fuel lines from secondary fuel filter to fuel pump are too long and not secured properly. Replace with approved fuel lines and secure properly.
Action required: 705 - Other - as specified
Due 15 December 2011
Resolved 21 November 2011
Resolution: Fuel lines replaced and secured properly.
Electrical › Electrical Distribution System (service) › Cable
Issued 17 August 2011 Resolved
Ref MSC Letter E2-1002042 item #1(a)- Cable for the Ship Service Generators is undersized and does not meet regulation of being rated at least 115% of capability of generator output. Replace cable with satisfactory size cable with proper rating. Draft proposal to OCMI for review and approval to replace cable.
Action required: 705 - Other - as specified
Due 31 December 2012
Resolved 12 February 2013
Resolution: Vessel made necessary repairs.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 17 August 2011 Resolved
Demonstrate operation of IBA embarkation lights on separate emergency branch circuits
Action required: 705 - Other - as specified
Due 31 December 2012
Resolved 31 December 2012
Resolution: IBA embarkation lights placed on separate emergency branch circuit.
Communications › Public Address System › Loudspeaker
Issued 27 July 2011 Resolved
Provide PA speaker that can be heard in Engine Control Booth.
Action required: 705 - Other - as specified
Due 27 August 2011
Resolved 28 September 2011
Resolution: PA speaker provided.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 27 July 2011 Resolved
Provide plans for prevention of loss of electrical power to propulsion control system.
Action required: 705 - Other - as specified
Due 27 August 2011
Resolved 28 September 2011
Resolution: Stickers that read "In Case Of Battery Failure, Switch Selector To Opposite Side!" posted in ENG room.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 28 January 2011 Resolved
Replace the number one fuel line on Starboard Main Engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 January 2011
Resolved 28 January 2011
Resolution: Fuel line renewed, engine was test ran with no issues noted.
Documentation › Certificates/Documents › Stability Letter
Issued 22 October 2010 Resolved
Record draft marks as required; prior to operating and prior to departing or when the deck load or liquid load of the vessel changes. These required recordings shall be placed in the deck log.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2010
Resolution: NCDOT provided logs to show draft marks are now being properly recorded.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 October 2010 Resolved
Renew "protective" glass for port main diesel engine shutdown.
Action required: 705 - Other - as specified
Due 29 October 2010
Resolved 22 October 2010
Resolution: Replaced protective glass covering.
Engineering › Fuel Oil Service System › Hose
Issued 10 February 2010 Resolved
Renew with continous single hose, prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2010
Resolution: Renewed with continous single hose
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 10 February 2010 Resolved
Fire extinguishers need to be installed in Engine Room. Evaluate Fire and Safety Plan on all "Old Kinnakeet Ferries". Submit Plans with recommendations to Coast Guard.
Action required: 705 - Other - as specified
Resolved 27 July 2011
Resolution: Inspected new fire extinguishers in Engine Room and verified updates to the Fire Control Plan.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 10 February 2010 Resolved
Demonstrate proper operation of Emergency Generator, prior to saling.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2010
Resolution: Showed proper operation of the Emergency Generator.
Lifesaving › Lifebuoys › Serviceable
Issued 24 July 2009 Resolved
Renew retro tape on life ring (starboard aft)
Action required: 705 - Other - as specified
Due 31 July 2009
Resolved 26 August 2009
Resolution: All retroreflective tape renewed.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 24 July 2009 Resolved
Install board to seperate child and Adult PFDs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2009
Resolved 24 August 2009
Resolution: Seperation board for adult and child pfd''s installed.
Communications › Radio Communications › VHF Radiotelephone
Issued 24 July 2009 Resolved
Provide vessel "bridge to bridge"
Action required: 705 - Other - as specified
Due 31 July 2009
Resolved 4 August 2009
Resolution: Bridge to bridge certificate issued.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 24 July 2009 Resolved
Correct electrical ground.
Action required: 705 - Other - as specified
Due 31 July 2009
Resolved 28 August 2009
Resolution: Electrical ground located and repaired.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 July 2009 Resolved
Install cover over pressure switch in lifejacket locker.
Action required: 705 - Other - as specified
Due 31 July 2009
Resolved 28 August 2009
Resolution: Pressure switch cover installed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 24 July 2009 Resolved
Install updated CO2 operations placard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2009
Resolved 3 August 2009
Resolution: Updated operating instructions installed.
Engineering › Fuel Oil Service System › Valve
Issued 24 July 2009 Resolved
Label fuel oils shutdowns for emergency generator
Action required: 705 - Other - as specified
Due 31 July 2009
Resolved 28 August 2009
Resolution: Fuel oil shutdown labeled.
Lifesaving › Rescue Boat › Capacity
Issued 24 July 2009 Resolved
Install a Coast Guard approved Rescue Boat with authorized Launching and Recovery Davit with Winch.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 December 2009
Resolved 24 September 2009
Resolution: Rescue Boat and Rescue Boat Davit installed and tested.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 3 September 2008 Resolved
No Proof of MIS report submission. No proof of contract with consortium.
Due 2 October 2008
Resolved 24 September 2008
Resolution: Documents and Information sent, company now in compliance.
Fire Fighting
Issued 16 January 1996 Resolved
PROVIDE PERMANENT PLACARD TO IDENTIFY MANUAL PULL FOR VALVE RELEASE TO FIXED CO2 SYSTEM FOR ENGINE ROOM (WHERE MISSING). ITEM TO BE COMPLETED NO LATER THAN 16 FEB 96 AND TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 19 January 1996
Resolved 23 January 1996
Navigation
Issued 16 June 1994 Resolved
REPAIR SOUND POWERED TELEPHONE FROM THE ENGINEROOM TO THE WHEELHOUSE, VERY WEAK SIGNAL._x001C_
Condition: Unknown
Due 16 June 1994
Resolved 16 June 1994
Fire Fighting
Issued 16 June 1994 Resolved
REPAINT/RESTENCIL ALL EXTERIOR MOUNTED FIRE AXES.
Condition: Unknown
Due 16 June 1994
Resolved 16 June 1994
Construction/Loadline
Issued 22 February 1994 Resolved
EFFECT PERMANENT REPAIRS TO THE BENT/DISTORTED TRANSVERSE DECK SUPPORTS. SIX TO BE REPLACED IN KIND AND ADDITIONAL TO BE STRAIGHTENED._x001C_ LOCATION: PORT SIDE FORWARD ADJACENT TO FOREPEAK TANK AND #1 VOID SPACE.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Construction/Loadline
Issued 22 February 1994 Resolved
EFFECT PERMANENT REPAIRS TO THE DISTORED STEEL PLATING IN WAY OF VEHICLE/PASSENGER RAIL. LOCATION: PORT SIDE FORWARD MOST AREA ADJACENT TO VEHICLE GUARD.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Construction/Loadline
Issued 22 February 1994 Resolved
EFFECT PERMANENT REPAIRS TO THE SIDE SHELL PLATING IN WAY OF A 6"X6"X3/4" INSET. INSET ADJACENT TO WATERTIGHT BULKHEAD BETWEEN FOREPEAK TANK AND #1 VOID SPACE.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Lifesaving
Issued 14 February 1994 Resolved
CONDUCT FIRE AND BAOT DRILL IN PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 14 February 1994
Resolved 14 February 1994
Engineering
Issued 14 February 1994 Resolved
PROVIDE ASTM INFO ON GREY CAST VALVES AS REQUIRED BY MSC-2 LETTER M-40060 DATED 26JAN94.
Condition: Unknown
Due 14 February 1994
Resolved 14 February 1994
Documentation
Issued 14 February 1994 Resolved
PROVIDE ON BOARD STABILITY LETTER.
Condition: Unknown
Due 14 February 1994
Resolved 14 February 1994
Engineering
Issued 14 February 1994 Resolved
PROVIDE APPROVED QUALITATIVE FAILURE ANALYSIS AS REQUIRED BY MSC LETTER E- 30666 DATED 02DEC93.
Condition: Unknown
Due 14 February 1994
Resolved 14 February 1994

Casualty record · 60

7 July 2005Routine · role: Involved in a Marine Casualty · activity 2423185
24 July 2005Routine · role: Involved in a Marine Casualty · activity 2452675
6 September 2005Routine · role: Involved in a Marine Casualty · activity 2486252
7 June 2006Routine · role: Involved in a Marine Casualty · activity 2677736
26 July 2006Routine · role: Involved in a Marine Casualty · activity 2727618
17 September 2006Routine · role: Involved in a Marine Casualty · activity 2787178
10 April 2007Routine · role: Involved in a Marine Casualty · activity 2905412
14 February 2008Routine · role: Involved in a Marine Casualty · activity 3147978
16 July 2008Routine · role: Involved in a Marine Casualty · activity 3270776
7 October 2008Routine · role: Involved in a Marine Casualty · activity 3340752
29 January 2009Routine · role: Involved in a Marine Casualty · activity 3401869
9 March 2010Routine · role: Involved in a Marine Casualty · activity 3693215
22 May 2010Routine · role: Involved in a Marine Casualty · activity 3745948
5 November 2010Routine · role: Involved in a Marine Casualty · activity 3887430
26 January 2011Routine · role: Involved in a Marine Casualty · activity 3933281
11 February 2011Routine · role: Involved in a Marine Casualty · activity 3943606
13 July 2011Routine · role: Involved in a Marine Casualty · activity 4080896
10 December 2011Routine · role: Involved in a Marine Casualty · activity 4206762
12 December 2011Routine · role: Involved in a Marine Casualty · activity 4206771
26 February 2012Routine · role: Involved in a Marine Casualty · activity 4251597
28 February 2012Routine · role: Involved in a Marine Casualty · activity 4254075
28 March 2012Routine · role: Involved in a Marine Casualty · activity 4275398
29 March 2012Routine · role: Involved in a Marine Casualty · activity 4275541
7 April 2012Routine · role: Involved in a Marine Casualty · activity 4282290
4 May 2012Routine · role: Involved in a Marine Casualty · activity 4303332
5 May 2012Routine · role: Involved in a Marine Casualty · activity 4303341
7 May 2012Routine · role: Involved in a Marine Casualty · activity 4305209
9 May 2012Routine · role: Involved in a Marine Casualty · activity 4307694
10 June 2012Routine · role: Involved in a Marine Casualty · activity 4340465
11 June 2012Routine · role: Involved in a Marine Casualty · activity 4341523
10 August 2012Routine · role: Involved in a Marine Casualty · activity 4409498
10 September 2012Routine · role: Involved in a Marine Casualty · activity 4437257
13 September 2012Routine · role: Involved in a Marine Casualty · activity 4439939
18 September 2012Routine · role: Involved in a Marine Casualty · activity 4444754
22 September 2012Routine · role: Involved in a Marine Casualty · activity 4449542
29 September 2012Routine · role: Involved in a Marine Casualty · activity 4454640
4 October 2012Routine · role: Involved in a Marine Casualty · activity 4457895
21 October 2012Routine · role: Involved in a Marine Casualty · activity 4469236
27 November 2012Routine · role: Involved in a Marine Casualty · activity 4491109
27 November 2012Routine · role: Involved in a Marine Casualty · activity 4491114
15 December 2012Routine · role: Involved in a Marine Casualty · activity 4503296
1 August 2013Routine · role: Involved in a Marine Casualty · activity 4686643
4 August 2013Routine · role: Involved in a Marine Casualty · activity 4686604
26 November 2013Routine · role: Involved in a Marine Casualty · activity 4760813
22 May 2014Routine · role: Involved in a Marine Casualty · activity 4866075
9 November 2015Routine · role: Involved in a Marine Casualty · activity 5761917
30 January 2016Routine · role: Involved in a Marine Casualty · activity 5807239
2 October 2018Routine · role: Involved in a Marine Casualty · activity 6555010
1 June 2019Routine · role: Involved in a Marine Casualty · activity 6706607
16 June 2019Routine · role: Involved in a Marine Casualty · activity 6933209
26 November 2020Routine · role: Involved in a Marine Casualty · activity 7119290
21 December 2020Routine · role: Involved in a Marine Casualty · activity 7158656
7 February 2021Routine · role: Involved in a Marine Casualty · activity 7142835
3 May 2021Routine · role: Involved in a Marine Casualty · activity 7189418
16 May 2021Routine · role: Involved in a Marine Casualty · activity 7201896
27 May 2021Routine · role: Involved in a Marine Casualty · activity 7238431
5 September 2021Routine · role: Involved in a Marine Casualty · activity 7308590
6 April 2022Routine · role: Involved in a Marine Casualty · activity 7428591
30 April 2022Routine · role: Involved in a Marine Casualty · activity 7447394
10 July 2022Routine · role: Involved in a Marine Casualty · activity 7548169
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.