Records from 2003 to 2026. Most recent: inspection, 26 May 2026.
Inspection history · 150
26 May 2026
Re-Inspection · Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8369088
18 April 2026
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8351837
9 February 2026
COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8276103
30 January 2026
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8303988
22 January 2026
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8300777
29 November 2025
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8275000
28 November 2025
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8274805
6 November 2025
Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8230473
17 October 2025
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8256163
21 September 2025
Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8238250
21 September 2025
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8245610
26 August 2025
Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8218272
15 August 2025
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8186523
6 August 2025
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8203669
1 July 2025
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8173097
1 July 2025
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8200203
13 June 2025
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8162017
28 May 2025
Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8146330
28 May 2025
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8157035
20 May 2025
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8139927
18 February 2025
COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8066896
21 August 2024
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7985996
6 June 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7929174
13 May 2024
In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7911779
18 April 2024
Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7897379
31 January 2024
Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7858401
31 October 2023
COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7815194
9 September 2023
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7789493
8 August 2023
Damage Survey · Examination of Repairs · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7763950
18 May 2023
Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7690639
2 February 2023
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7630474
23 December 2022
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7612461
22 December 2022
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7612495
29 November 2022
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7601055
30 October 2022
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7586306
29 October 2022
Special
Type not classified · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7585800
6 October 2022
MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7572950
10 May 2022
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7447865
1 April 2022
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7423096
25 October 2021
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7339183
22 October 2021
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7344978
9 October 2021
Special
Type not classified · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7331053
9 October 2021
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7344697
21 September 2021
Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7317768
21 September 2021
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7322432
16 September 2021
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7313754
16 September 2021
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7322037
30 August 2021
Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7300727
26 August 2021
Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7296556
2 June 2021
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7206112
10 February 2021
MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7137339
25 November 2020
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7104162
24 August 2020
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7048575
19 August 2020
Re-Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7037264
20 May 2020
Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6957977
19 February 2020
COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6910988
19 September 2019
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6814292
26 June 2019
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6927871
11 June 2019
Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6709671
7 January 2019
Administrative Inspection · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6613510
21 August 2018
Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6519701
21 August 2018
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6538963
13 August 2018
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6510056
16 July 2018
Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6483227
16 July 2018
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6521492
21 June 2018
Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6456325
1 June 2018
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6456851
18 May 2018
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6434564
18 May 2018
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6441322
7 May 2018
MTSA Verification · Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6405988
15 April 2018
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6402229
30 March 2018
Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6381911
29 March 2018
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6390145
21 February 2018
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6358767
7 February 2018
Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6336346
16 January 2018
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6338911
6 December 2017
Examination of Repairs · Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6314743
17 August 2017
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6259854
11 May 2017
MTSA Verification · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6144752
2 February 2017
MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6077311
3 October 2016
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6014986
3 August 2016
Examination of Repairs
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5961734
22 July 2016
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5953498
20 April 2016
Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5858731
11 April 2016
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 5852790
28 January 2016
Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5803518
1 December 2015
In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5773237
3 November 2015
Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5757184
26 October 2015
COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5750683
21 October 2015
Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5748372
1 September 2015
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5232914
24 August 2015
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5225746
12 August 2015
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5213105
29 October 2014
COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5009436
7 October 2014
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5002810
25 June 2014
Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4905630
19 June 2014
Spot Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4893979
17 June 2014
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4900645
20 May 2014
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4863017
5 May 2014
Re-Inspection · Construction Oversight
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4850658
30 June 2012
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4364600
23 June 2012
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4355758
23 May 2012
Periodic Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4319507
2 May 2012
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4302049
26 January 2012
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4231977
3 August 2011
Periodic Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4103883
16 July 2011
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4085853
4 February 2011
Periodic Inspection · Spot Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3938815
25 January 2011
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3933284
14 January 2011
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3926758
5 November 2010
MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3858348
1 November 2010
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3882942
28 September 2010
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3858847
15 September 2010
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3850460
7 September 2010
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3844931
4 March 2010
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3690296
12 February 2010
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3679072
10 February 2010
Periodic Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3677930
10 February 2010
Spot Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3680365
26 January 2010
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3670262
17 January 2010
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3665816
14 January 2010
Spot Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3664023
4 January 2010
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3658281
25 July 2009
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3547177
17 February 2009
MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3419587
18 September 2008
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3327343
21 August 2008
Spot Check · Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3304565
5 June 2008
MTSA Verification · Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3224798
28 February 2008
COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3155030
18 September 2007
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3060468
28 February 2007
COI Inspection · MTSA Verification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2880544
18 October 2006
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2804454
18 October 2006
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2806933
5 September 2006
MTSA Verification · Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2769675
23 August 2006
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2757190
16 August 2006
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2755756
18 July 2006
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2719245
5 June 2006
Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2670685
24 February 2006
COI Inspection · MTSA Verification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2591319
3 August 2005
Spot Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2456634
9 July 2005
MTSA Verification
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2435842
22 June 2005
Damage Survey · Examination of Repairs
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2399462
7 June 2005
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2382485
3 June 2005
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2377907
9 March 2005
Deficiency Check · MTSA Verification · COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2302895
5 November 2004
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2305236
6 April 2004
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2040613
19 March 2004
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2022237
23 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1991469
30 January 2003
Initial Certification · Deadweight Survey · Hull Examination · Internal Structural Exam · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1859773
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 26 May 2026
Resolved
Appliances to insure watertight integrity include watertight doors, hatches, scuttles, bolted manhole covers, or other watertight closures for openings in watertight decks and bulkheads. During the Firemain/sprinkler system test was found that the emergency escape scuttle in the CO2 space was leaking water. Conduct repairs and test to the satisfaction of attending CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2026
Resolved 22 June 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 November 2025
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Marine Vessel Rules (incorporated by reference, see § 58.03-1), except as otherwise provided by this subchapter.
"B End" primary steering system would not engage and automatically switched to secondary steering. Repairs and operation must be completed to the satisfaction of USCG Marine Inspector.
46 CFR 58.05-1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 November 2025
Resolution: Deficiency rectified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 November 2025
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Marine Vessel Rules (incorporated by reference, see § 58.03-1), except as otherwise provided by this subchapter.
"B End" primary steering system would not engage and automatically switched to secondary steering. Repairs and operation must be completed to the satisfaction of USCG Marine Inspector.
46 CFR 58.05-1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 November 2025
Resolution: Received notification from NCDOT Maintenance during troubleshooting, a loose wire connection from the alarm input to the control cabinet was found. Once the wire was resecured the alarm cleared and the steering system was able to operate properly. tested
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 7 November 2025
Resolved
Means shall be provided for closing all openings to the space protected from outside such space. In this respect, relatively tight doors, shutters, or dampers shall be provided for openings in the lower portion of the space. The construction shall be such that openings in the upper portion of the space can be closed off either by permanently installed means or by the use of canvas or other material which is normally carried by the vessel. MI observed the door gasket not sealing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2025
Resolved 12 January 2026
Resolution: Gasket hardware was replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 November 2025
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Marine Vessel Rules (incorporated by reference, see § 58.03-1), except as otherwise provided by this subchapter. MI observed that the B-end engine was having a fault code for a high J/W temp alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2025
Resolved 12 January 2026
Resolution: The harness connections were repaired
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 7 November 2025
Resolved
An emergency means of communication required by this subpart must—(1) Be comprised of either fixed or portable equipment; and(2) Provide common talking means of two-way voice communication and calling among the navigating bridge, emergency control stations, muster stations, embarkation stations, and other strategic positions listed in § 113.30-5. MI observed that the call/ringer spin handle broke on the A end sound powered phone. Call station will not be able to notify any other stations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2025
Resolved 10 December 2025
Resolution: Sound powered phone handle has been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 October 2025
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Marine Vessel Rules (incorporated by reference, see § 58.03-1), except as otherwise provided by this subchapter. The #1 generator lost power. Complete all repairs to the #1 generator as needed to the satisfaction of the Coast Guard.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 October 2025
Resolution: NCDOT replaced #1 generator in kind. Generator was tested under full load for 45 min. All systems tested satisfactory and confirmed by the attending CG Marine Inspector.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 15 August 2025
Resolved
This subpart prescribes regulations governing the design and construction of marine sanitation devices. MI observed the MSD blower fan not working as designed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2025
Resolved 25 August 2025
Resolution: Repaired pump and check valve in system. Deficiency rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 July 2025
Resolved
B main engine overheated and was secured during transit.
Complete repairs to the satisfaction of the Coast Guard ensuring the engine no longer over heats.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2025
Resolved 3 July 2025
Resolution: NCDOT replaced both thermostats on the Croatoan B Main Engine. NCDOT test ran U/W for an hour at normal operating rpm's and up to 1200 rpm's. After repairs on the Croatoan was complete, the vessel underwent sea trials for over an hour.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 May 2025
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Marine Vessel Rules (incorporated by reference, see § 58.03-1), except as otherwise provided by this subchapter.
The vessel's "B" end Voith propulsion unit is experiencing fluctuating oil pressure and vibrations. Conduct repairs as appropriate to bring to the unit to full operating capacity to the satisfaction of the attending USCG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2025
Resolved 6 June 2025
Resolution: B end Voith was replaced. MI Witnessed PSTP's; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 20 May 2025
Resolved
Each space used by passengers or crew must be fitted with lighting that provides for a safe habitable and working environment under normal conditions. Light located in the Engine Room behind the ECR is out.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 6 June 2025
Resolution: Inspected lighting; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 May 2025
Resolved
Electric installations on vessels must ensure maintenance of services necessary for safety under normal and emergency conditions. Battery terminal loose on multiple battery installation, check all battery terminal connections and ensure proper connection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 6 June 2025
Resolution: Inspected battery installations; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 May 2025
Resolved
Electric installations on vessels must ensure maintenance of services necessary for safety under normal and emergency conditions. B end generator- Customer Connection Panel is secured by duct tape, apply proper latching devices to secure panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 6 June 2025
Resolution: Inspected B end generator- Customer Connection Panel; all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 May 2025
Resolved
In general, compliance with the standards established by the American Bureau of Shipping, see subpart 70.35 of this subchapter, will be considered satisfactory evidence of the structural efficiency of the vessel. The escape hatches located in both the A and B end Voith spaces are not watertight and leaking water into the Voith rooms. Adjust escape hatches to make water tight and empty out existing oily bilge water in both spaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 6 June 2025
Resolution: Inspected water tight escape hatches; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2024
Resolved
Auxiliary machinery vital to the main propulsion system must be provided in duplicate. Vessel experienced high coolant temperature alarm on the "B" end main engine, with water spewing from the expansion tank. Operator reported vessel must operate at reduced RPMs to maintain appropriate temperatures and avoid overheating. Identify and correct auxiliary machinery issues to the satisfaction of the Coast Guard prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2024
Resolved 14 May 2024
Resolution: Vessel replaced water pump and completed successful sea trials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 September 2023
Resolved
MSD Nags Head was informed by the master of the M/V CROATOAN that while underway from Ocracoke to Hatteras the vessel experienced a loss of propulsion on the B End Voith. This was caused by a faulty coupling on the shaft leading from the engine to the B End Voith unit. Ensure permanent repairs are performed to the satisfaction of USCG Marine Inspector prior to taking passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2023
Resolved 13 September 2023
Resolution: Shaft coupling replaced. SAT Sea Trial performed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 December 2022
Resolved
While underway the vessel's number 01 generator experienced a reduction in voltage, requiring the generator to be shut down and the number 02 generator to be brought on line. Conduct permanent repairs to the vessel's number 01 generator prior to carrying passengers. All repairs are to be made to satisfaction of attending MI. 46CFR70.25-1
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 December 2022
Resolved 23 December 2022
Resolution: NCDOT maintenance crews replaced the voltage regulator on #1 SSDG. Conducted test of SSDG. Test SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 December 2022
Resolved
Vessel Reported the #1 generator was not able to carry the electrical load when switched over from the #2 generator, forcing the the emergency generator to activate. Vessel requested to dead head from Ocracoke to Hatteras for repairs under the #2 generator, approved. All repairs are to be made prior to carrying passenger and all repairs are to be made to satisfaction of attending MI. 46 CFR 70.25-1.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 December 2022
Resolved 22 December 2022
Resolution: NCDOT maintenance crews replaced a bent shaft on the throttle assembly. Conducted sea trails. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 November 2022
Resolved
Arrangement of auxiliary machinery must meet inspection standards. Marine Inspectors were notified via vessel master that the CROATOAN'S No. 1 generator is inoperable. Effect permanent repairs to satisfaction of attending Marine Inspector.46CFR58.05-1
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2022
Resolved 29 November 2022
Resolution: Conducted proper repairs to generator throttle and replaced fuse on voltage sensor. Test SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 October 2022
Resolved
A-end voith unit loss of oil pressure. Make repairs and verify other voith system oil system. Conducted sea trails and submit maintenance report and Capts statement for SAT sea trails. All repairs are to be completed to satisfaction of attending Marine Inspector as per 46CFR58.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2022
Resolution: Direction indictor found to be loose causing the system to give a loss of oil PSI. indicator reinstalled and voith unit tested SAT. B-end was also check with no issues.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 October 2022
Resolved
Operator reported that the A end main engine had a keel cooler supply house failure and shut the MDE down and returned to Hatteras Dock . Provide corrective actions taken to rectify issue via maintenance tech report and CG-2692. Vessel must be cleared by a USCG marine inspector from this office before returning to service as per 46CFR56.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 October 2022
Resolution: New hose installed and tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 October 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 October 2022
Resolution: Voith unit removed and rebuilt. Operational test SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 October 2021
Resolved
Operator reported that the B end propulsion unit had a bad actuator and not functioning as intended. Provide tech report attesting to casual factor that led to failure and corrective actions completed. Vessel must undergo sea trials to prove proper operation prior to carrying passengers.
Action required: 60 - Rectify deficiencies prior to movement
Due 12 October 2021
Resolved 14 October 2021
Resolution: Broken control arms welded and new pin installed. All test SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 September 2021
Resolved
Received report of steering system failure and controlled allision. Reported that the B-end voith longitudinal actuator failed. Trouble shot and made permmanent repairs.
Action required: 10 - Deficiency Rectified
Resolved 22 September 2021
Resolution: New B-end longitudinal actuator installed and tested with sea trials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 September 2021
Resolved
NCDOT reported a leak in the keel cooler associated with the B-end MDE. Identify cause and location of the damage and make repairs iaw 46 CFR 71.15-1.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 September 2021
Resolution: New keel cooler installed and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2021
Resolved
NCDOT reported a leak in the keel cooler associated with the B-end MDE. Identify cause and location of the damage and make repairs iaw 46 CFR 71.15-1.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 September 2021
Resolution: Keel cooler replaced and tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 26 August 2021
Resolved
Rescue boat control cable wasted. Rescue boat cradle snap rings for pin missing and wasted IAW 46CFR70.28-1. / 705C Vessel permitted one time transit to Hatteras.
Action required: 705 - Other - as specified
Due 26 August 2021
Resolved 26 August 2021
Resolution: NCDOT made repairs to equipment on site after transitting to Hatteras.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 26 August 2021
Resolved
Rescue boat gel coat repairs in numerous areas as discussed IAW 46CFR70.28-1.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2021
Resolved 14 September 2021
Resolution: Gel Coat repairs completed with exception of final touch up paint.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 August 2021
Resolved
Both MDE Breather hoses cracked and leaking 46CFR70.20-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2021
Resolved 14 September 2021
Resolution: New air box hoses installed both MDEs.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 August 2021
Resolved
CO2 Bottle mount loose IAW 46CFR76.15-20(d)
Action required: 10 - Deficiency Rectified
Due 26 August 2021
Resolved 26 August 2021
Resolution: Mount adjusted and tightened on scene.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 August 2021
Resolved
CO2 room A end and void room B end hatches leaking IAW 46CFR72.30-1./ 705C one time transit to Hatterass
Action required: 705 - Other - as specified
Due 26 August 2021
Resolved 26 August 2021
Resolution: Adjusted hatches and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 26 August 2021
Resolved
A-End #1 generator murphy switch inoperable IAW 46CFR77.03-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2021
Resolved 26 August 2021
Resolution: New Switch installed sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 February 2021
Resolved
Found two permanently installed extension cords in the engine room. Remove the cords.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2021
Resolved 11 February 2021
Resolution: Extension cords have been removed.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 10 February 2021
Resolved
Found portable sound powered phone headset ooc. Repair/ replace headset.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2021
Resolution: Headset repaired; op test sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 February 2021
Resolved
Found broken latch securing drawer containing security documents. Replace latch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2021
Resolved 11 February 2021
Resolution: Latch has been replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 February 2021
Resolved
Found all flush deck "Freeman" hatch covers no longer watertight. Replace gaskets and prove tightness.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2021
Resolution: New gaskets have been installed on all flush deck hatch covers; op test sat.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 February 2021
Resolved
Found aftermost overhead light on vehicle deck ooc. Replace burned out light bulbs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2021
Resolved 11 February 2021
Resolution: New lightbulb has been installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 August 2020
Resolved
During on-board testing, crew was unfamiliar with properly aligning bilge suction for prime and suction for minimum PSI at fire hose. Ensure all crew are familiar with characteristics of vessel assigned.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 24 August 2020
Resolution: Attended vessel, conducted onboard drills relating to dewatering and valve alignment, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 August 2020
Resolved
Fire hose failed while under inspection. Replace with new spare on-board, old hose destroyed.
Action required: 10 - Deficiency Rectified
Resolved 19 August 2020
Resolution: Corrected on the spot using on board spare.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 19 August 2020
Resolved
Voith unit on both ends have small leaks, bolts rusted. Replace bolts and mitigate water ingress.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 2 September 2020
Resolution: Received photos of replaced bolts and seal to prevent water ingress.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 February 2020
Resolved
Found A-end and B-end emergency fuel shut-off valves leaking at the packing gland. Adjust packing gland.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2020
Resolved 9 March 2020
Resolution: Fuel shut-off valves repaired.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 19 February 2020
Resolved
Found sound powered phone on B-end main deck inoperable. Repair phone.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2020
Resolved 9 March 2020
Resolution: Sound powered phones tested and found sat.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 February 2020
Resolved
Found emergency shutdown for engine room ventilation fan missing the hammer. Attach hammer to break glass.
Action required: 10 - Deficiency Rectified
Resolved 19 February 2020
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 February 2020
Resolved
Found vessel to be missing six required life preservers. Reduced passenger count from 300 to 294.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2020
Resolved 9 March 2020
Resolution: New life preservers added and properly marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 February 2020
Resolved
Unable to verify proper operation of two pressure vessel safety relief valves during inspection. Prove proper operation of relief valves.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2020
Resolved 9 March 2020
Resolution: Relief valves tested and found sat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 19 February 2020
Resolved
Found manual release pin on the #6 IBA cradle corroded. Replace pin.
Action required: 10 - Deficiency Rectified
Resolved 19 February 2020
Resolution: Corrected on the spot.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 19 September 2019
Resolved
Found EDG battery dead due to loose battery charger cable. Replace battery.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2019
Resolved 19 September 2019
Resolution: Corrected on the spot; installed new battery. Operational test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 August 2018
Resolved
B-end steering system (voith) failing when helm is turned hard over. Complete proper repairs and full function test in the presence of a USCG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2018
Resolution: Found B-end transverse hydraulic actuator replaced and witnessed full function test of system to include applicable portions of PSTPs. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 July 2018
Resolved
#2 ship service diesel generator suffered an oil cooler failure. Complete proper repairs and demonstrate full function test to the satisfaction of an attending CG Marine Inspector prior to the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2018
Resolution: Hatteras maintenance installed a new L/O cooler; operational test sat.
Operations/Management › Vessel Activity › Loading
Issued 7 May 2018
Resolved
Found a vehicle parked on the A-end emergency fuel shut-off valve.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 May 2018
Resolved 7 May 2018
Resolution: Master held discussion with all deckhands and vehicles were properly loaded.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 7 May 2018
Resolved
Found the gasket to short on the void 2A WTD. Replace gasket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2018
Resolved 1 June 2018
Resolution: New WTD gasket has been installed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 7 May 2018
Resolved
Found multiple motor controllers missing the required schematics. Post schematics.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 1 June 2018
Resolution: Schematics have been posted.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 30 March 2018
Resolved
Prior to passenger operations, perform repairs to the B End main engine jacket water cooling system and keel cooler to the satisfaction of the Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 2 April 2018
Resolution: A new keel cooler was tested and installed.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 7 February 2018
Resolved
Emergency generator vent louvers not closing 100% with out manual assistance. CAPT has designated one person to ensure vent will be closed in the event of a fire.
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 26 February 2018
Resolution: NCDOT sent video of dampners properly operating.
Lifesaving › Launching Appliances › Davit
Issued 7 February 2018
Resolved
Rescue boat davit lever is wasted and needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 14 March 2018
Resolution: New lever installed.
Lifesaving › Launching Appliances › Davit
Issued 7 February 2018
Resolved
Rescue boat remote control, lower sheave pin wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 26 February 2018
Resolution: NCDOT provided video of new pin
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 7 February 2018
Resolved
#6 Portable fire ext. pin missing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 26 February 2018
Resolution: Pin installed
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 February 2018
Resolved
Main deck B side second ladder rung loose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 26 February 2018
Resolution: Rung tightened
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 7 February 2018
Resolved
CO2 Fixed system bottle brackets loose. Which could allow the bottles to turn and kink CO2 hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2018
Resolved 7 February 2018
Resolution: All brackets tighened.
Communications › Public Address System › Announcing Station
Issued 6 December 2017
Resolved
The vessels PA system started smoking during periodic and was not working as designed.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2017
Resolved 6 December 2017
Resolution: M/I verified newly installed PA amplifier and conducted operational test of system and componets. System and operational checks were verified satisfactory this date by attending M/I.
Engineering › Steering Gear System › Bracket/Clamp
Issued 6 December 2017
Resolved
The emergency intructions for local steering operation is missing orange and yellow tags for pins.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 December 2017
Resolved 7 May 2018
Resolution: Pins have been properly marked.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 6 December 2017
Resolved
Unknown subtance in a flammable container was found in the flammable locker in the engine rooom.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 December 2017
Resolved 6 December 2017
Resolution: Crew removed the container from vessel during attendance this date.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Discharge Hose
Issued 6 December 2017
Resolved
Install missing fire extinguisher pins on the #6 and #8.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2017
Resolved 6 December 2017
Resolution: Install pins on the fire extinguishers (#6 and #8)
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 April 2016
Resolved
Replace the expired eye wash bottle in the first aid kit in the pilothouse.
Due 4 May 2016
Resolved 6 February 2017
Resolution: Expired eye wash bottle was replaced.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 20 April 2016
Resolved
Replace the flame screen on the "A" end fuel tank vent pipe with one of proper 30 X 30 mesh.
Due 4 May 2016
Resolved 6 February 2017
Resolution: Verrified the installation of new flame screens.
Documentation › Manuals/Policy Documentation › Steering Gear Changeover Instructions
Issued 20 April 2016
Resolved
Provide instructions, in the steering gear room, for changing steering gear controls to local control.
Due 4 May 2016
Resolved 6 February 2017
Resolution: Verified posting of emergency steering procedures.
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 28 January 2016
Resolved
Flame screen on "A" end has a hole where the check ball has been vibrating.
Due 6 February 2016
Resolved 5 February 2016
Resolution: Flame screen properly installed.
Lifesaving › Launching Appliances › Davit
Issued 1 December 2015
Resolved
Make proper repairs to davit and prove proper operation prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 December 2015
Resolved 3 December 2015
Resolution: Vessel replaced davit gear box and cables. Witnessed satisfactory test of davit systems in accordance with MSM Vol II, Section B Chap 1.P.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 28 October 2015
Resolved
Vessel is over 400 GT ITC and is currently on a route which charges a fee, therefore it does not meet the definition of a public vessel and must have a NTVRP.
Due 28 December 2015
Resolved 19 January 2016
Resolution: Verified in MISLE that the vessel has been added to the companies VSP (NT) for Sector NC.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 26 January 2012
Resolved
Install cap IWO main SWBD shore power availible light.
Action required: 705 - Other - as specified
Due 2 March 2012
Resolved 23 May 2012
Resolution: Cap was installed on shore power light.
Fire Fighting › Fire Pumps › Pressure
Issued 26 January 2012
Resolved
Correct marginal fire main pressure issue. The fire pump pressure is 61 PSI. The vessel still has an effective stream @ the two highest outlets, but the issue needs correction.
Action required: 705 - Other - as specified
Due 9 February 2012
Resolved 23 May 2012
Resolution: Fire pump was tested with two fire hoses, one high one low, all sat.
Stability › Watertight Integrity › General
Issued 3 August 2011
Resolved
Demonstrate proper operation of Water Tight Door Alarm indictor for Entrance to Engine Room.
Action required: 705 - Other - as specified
Due 3 September 2011
Resolved 15 August 2011
Resolution: Water tight door alarm functioning properly
Lifesaving › Lifebuoys › Serviceable
Issued 3 August 2011
Resolved
Provide approved UV Resistant line for Life Rings.
Action required: 705 - Other - as specified
Due 3 September 2011
Resolved 15 August 2011
Resolution: Received documentation from manufacturer that line on life rings is UV resistant.
Communications › Public Address System › Broadcast Location
Issued 3 August 2011
Resolved
Provide Additional PA Speaker for Engine Room Control Booth.
Action required: 705 - Other - as specified
Due 3 September 2011
Resolved 3 August 2011
Resolution: Entered in error.
Communications › Alarms/Indicators › General Alarm
Issued 3 August 2011
Resolved
Provide Alarm Placard for Engine Room Light.
Action required: 705 - Other - as specified
Due 3 September 2011
Resolved 16 September 2011
Resolution: Alarm placard provided.
Engineering › Fuel Oil Service System › Valve
Issued 3 August 2011
Resolved
Provide Fuel Oil Shut Off direction for "off".
Action required: 705 - Other - as specified
Due 3 September 2011
Resolved 16 September 2011
Resolution: Fuel oil shut off labeled.
Engineering › Fuel Oil Service System › Valve
Issued 5 November 2010
Resolved
Install approved Fuel Oil valves at the next drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 November 2011
Resolved 5 November 2010
Electrical › Electrical Distribution System (service) › Busway
Issued 17 February 2009
Resolved
Adjust wire penetrations on bulkhead in the Emrgency Generator Room, above the electrical panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2009
Resolved 3 March 2009
Resolution: Wire penetrations were adjusted.
Fire Fighting › Nozzles › Condition
Issued 17 February 2009
Resolved
Repair chain on fire nozzle at fire station #3.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2009
Resolved 3 March 2009
Resolution: Replaced Nozzle Chain with new one.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 17 February 2009
Resolved
Properly label location of additional childs life jackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 March 2009
Resolved 3 March 2009
Resolution: All locations of childs lifejackets were properly labeled.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 17 February 2009
Resolved
A-end engine turbo lagging needs to be tightened and tighten bolts connecting turbo to stop exhaust leak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2009
Resolved 3 March 2009
Resolution: Turbo bolts have been tightened and the lagging has been reapplied.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 17 February 2009
Resolved
Install cap on spare lube oil tank discharge drain
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2009
Resolved 3 March 2009
Resolution: A plug was installed on the oil discharge drain.
Personnel › Training › Fire Fighting Basic
Issued 17 February 2009
Resolved
Implement training manual for each class of vessel with specifics on fire, abandon ship and man overboard procedures
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2009
Resolved 4 March 2009
Resolution: Operation Manager inserted training specifics into NCDOT SIP Manual, all vessels issued this Manual, which outlines responsibility.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 17 February 2009
Resolved
Renew placard at the CO2 tank location (placard is incorrect)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 March 2009
Resolved 3 March 2009
Resolution: A new placard was installed by the crew.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 17 February 2009
Resolved
Move the eye washing station in the engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 March 2009
Resolved 3 March 2009
Resolution: Eye wash station has been moved to another location.
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 February 2009
Resolved
Remove all liquids and decbris from battery trays throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2009
Resolved 3 March 2009
Resolution: All liquids have been removed and battery boxes have been cleaned.
Stability › Watertight Integrity › General
Issued 17 February 2009
Resolved
Adjust watertight doors 2 & 3 on the A end.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2009
Resolved 3 March 2009
Resolution: Adjustments were made to the watertight doors.
Electrical › Electric Generation Source (service) › Generator
Issued 17 February 2009
Resolved
Repair fuel leak on the B end generators racor fuel filter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2009
Resolved 3 March 2009
Resolution: Repaired fuel leak.
Fire Fighting › Portable CO2 Fire Extinguisher › Discharge Hose/Tube
Issued 28 February 2008
Resolved
Cracked discharge hose, replaced on the spot
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2008
Resolved 28 February 2008
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 28 February 2008
Resolved
Rescue boat winch would not lower boat after drill, switched replace on the spot. operation satisfactory.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2008
Resolved 28 February 2008
Fire Fighting › Ventilation Systems › Operating Controls
Issued 28 February 2007
Resolved
Several vent closures (fire) require PMS; several louvers did not properly close by use of the lever - perform maintenance on all louvers (louver were able to be closed manually one by one)
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 4 March 2007
Resolution: NCDOT performed required maintenance to vent closures (fire).
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 28 February 2007
Resolved
Fire extinguisher are loose in the mounts located on the super structure. Tighten securing band to prevent the extinguisher from movement.
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 4 March 2007
Resolution: NCDOT tightened mounts to secure fire extinguishers.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 28 February 2007
Resolved
Main Diesel Engine located on A-end; replace existing test valve (ball valve) for low lube oil alarm with the proper three way testing valve (See B-end for example); existing valve in the off position does not allow oil pressure to reach the sending unit for alarm, and in the on mode, relies on a pipe plug to prevent oil discharge.
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 4 March 2007
Resolution: NCDOT installed proper three way testing valve.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 5 September 2006
Resolved
Handle is missing from CO2 hose reel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 September 2006
Resolved 7 September 2006
Resolution: Installed
Lifesaving › Inflatable Liferafts › Float Free
Issued 5 September 2006
Resolved
Liferaft on "A" end is to be secured.
Action required: 705 - Other - as specified
Due 13 September 2006
Resolved 6 September 2006
Resolution: Resolved.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 5 September 2006
Resolved
One adult lifejacket to have retrorefletive tape fixed.
Action required: 705 - Other - as specified
Due 13 September 2006
Resolved 6 September 2006
Resolution: Installed
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 5 September 2006
Resolved
Provide lifejackets for watchstanders on bridge (2).
Action required: 705 - Other - as specified
Due 13 September 2006
Resolved 6 September 2006
Resolution: Provided
Fire Fighting › Fire Main › Valves
Issued 5 June 2006
Resolved
Install missing pressure relief valve IWO fire main system IAW 76.10-5. Provide approved plans for the relief valve installation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 23 August 2006
Resolution: Installed.
Lifesaving › Launching Appliances › Davit
Issued 24 February 2006
Resolved
Renew rescue boat davit winch. Winch does not meet the 59' per minute speed requirement.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 12 September 2007
Resolution: Davit to be renewed w/ an approved arrangement at the next DD.
Operations/Management › Drills/Instruction › Fire
Issued 8 August 2003
Resolved
Conduct satisfactory fire and abandon ship drills as required by 46 CFR 199.180(c). LEGACY COMPONENT DESC: Fire and Abandon Ship Drills
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 September 2003
Resolved 9 March 2005