Records from 2006 to 2025. Most recent: inspection, 25 August 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 61
25 August 2025
Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8218717
5 June 2024
Administrative Inspection · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7927649
23 March 2024
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7895711
18 February 2024
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7867038
16 February 2024
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7866717
13 October 2023
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7808188
22 November 2022
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7602080
28 October 2022
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7585362
14 September 2021
Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7312178
14 September 2021
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7316177
12 September 2021
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7311056
23 June 2021
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7233467
22 June 2021
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7234978
22 June 2021
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7238484
10 June 2021
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7221326
30 May 2021
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7213157
30 May 2021
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7238595
2 May 2021
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7188331
2 May 2021
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7199013
12 March 2021
Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7155200
4 February 2021
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7135910
4 February 2021
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7145029
9 December 2020
Administrative Inspection · Re-Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7108826
19 November 2020
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7098340
23 September 2020
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7064399
24 June 2020
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6956714
23 March 2020
COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6897302
6 March 2020
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6979303
28 January 2020
Examination of Repairs · Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6899724
8 January 2020
MTSA Verification · Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6836276
15 October 2019
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6834580
2 October 2019
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6821628
27 September 2019
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6824227
27 September 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6863274
27 September 2019
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6888253
26 September 2019
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6822067
26 September 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6893782
14 June 2019
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6770645
9 April 2019
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6698151
18 March 2019
COI Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6644442
3 October 2018
Internal Structural Exam · Hull Examination · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6562161
26 August 2018
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6531612
14 June 2018
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6403450
21 March 2018
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6354472
21 February 2018
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6358758
9 January 2018
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6335442
8 January 2018
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6336571
1 November 2017
MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6299047
20 September 2017
COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6233557
6 September 2017
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6261589
24 August 2017
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6250737
22 June 2017
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6154239
21 April 2017
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6132025
16 March 2017
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6084651
13 February 2017
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6088755
8 February 2017
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6085073
11 January 2017
Periodic Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6056896
20 October 2016
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6085692
12 October 2016
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6021065
20 September 2016
MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6005104
26 May 2016
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5887717
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 14 September 2021
Resolved
A survey either general or partial, according to the circumstances shall be made every time an accident occurs or defect is discovered which affects the safety of the vessel. The master reported the vessel's rescue boat davit, controller will not work in the down position. Determine the cause of failure, make proper repairs to the satisfaction of the Coast Guard. Prior to the carriage of passengers or cargo.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2021
Resolved 14 September 2021
Resolution: Found broken wire in davit junction box, preventing the proper operation of the davit as designed. Repairs made to the satisfaction of the Coast Guard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 September 2021
Resolved
A survey either general or partial, according to the circumstances shall be made every time an accident occurs or a defect is discovered which affects the safety or the vessel. The master reported a fuel leak from fuel sending unit on #1 generator. Troubleshoot to determine cause of casualty and repair to the satisfaction of the Coast Guard.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2021
Resolved 12 September 2021
Resolution: The fuel oil sending unit was replaced and operationally tested to the satisfaction of the Coast Guard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 June 2021
Resolved
Aft portside CO2 fire extinguisher bracket is wasted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2021
Resolved 23 June 2021
Resolution: Bracket was replaced with new.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 June 2021
Resolved
Attach 2 existing security chains for stanchions IVO portside IBA
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2021
Resolved 23 June 2021
Resolution: Chains were properly attached.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 June 2021
Resolved
Install clip on security chain on starboard side IBA stanchion
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2021
Resolved 23 June 2021
Resolution: Clip installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 June 2021
Resolved
Aft starboard CO2 fire extinguisher discharge hose is showing signs of cracking.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2021
Resolved 2 July 2021
Resolution: Hose replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 June 2021
Resolved
Rudder angle indicator in EOS is 5 degrees difference from pilothouse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2021
Resolved 23 June 2021
Resolution: Electrician adjusted the amplifier and conducted satisfactory test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 June 2021
Resolved
Port generator F/O return line is damaged, replace in kind.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 23 June 2021
Resolved 23 June 2021
Resolution: The fuel line was renewed and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 June 2021
Resolved
Port MDE F/O strainer was loose
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 June 2021
Resolved 23 June 2021
Resolution: F/O strainer was tightened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 June 2021
Resolved
Starboard generator strainer assembly was found loose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 June 2021
Resolved 23 June 2021
Resolution: Strainer assembly was tightened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 June 2021
Resolved
Starboard main engine F/O return line is damaged. Renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2021
Resolution: F/O line was renewed and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 June 2021
Resolved
Starboard main engine high pressure line inboard missing hold down clamp.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2021
Resolution: Clamp was added to properly secure the line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 June 2021
Resolved
Starboard main engine local gauge assembly needs replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2021
Resolved 30 June 2021
Resolution: The local gauge assembly was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 23 June 2021
Resolved
Replace rescue boat fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2021
Resolved 30 June 2021
Resolution: Fuel tank was replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 23 June 2021
Resolved
Remove or secure microwave in MSD space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2021
Resolved 30 June 2021
Resolution: Microwave is properly secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 June 2021
Resolved
Port and starboard main engine clutch have loose and missing hardware on cover.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2021
Resolved 2 August 2021
Resolution: Main engine clutch control was added with hardware and secured.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 23 June 2021
Resolved
Perform sea trials and emergency drills to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2021
Resolution: Performed sea trials and emergency drills.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 June 2021
Resolved
Replace starboard main engine (outboard) hose to governor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2021
Resolved 30 June 2021
Resolution: Hose was replaced and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 22 June 2021
Resolved
The vessels rescue boat davit controller malfunctioned during testing with passengers onboard. Determine cause and make proper repairs to the satisfaction of the Coast Guard.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2021
Resolved 23 June 2021
Resolution: Repairs completed to the satisfaction of the attending inspector. CPrev briefed. See narrative for details. AN 7234978
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 10 June 2021
Resolved
The vessels rescue boat davit malfunctioned. Troubleshoot and determine the cause of the malfunction, prior to passengers or cargo ops.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2021
Resolved 10 June 2021
Resolution: The controller was found corroded and replaced. The davit was inspected and operationally tested after installation of new wire rope.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 30 May 2021
Resolved
MI notified that while underway with no passengers the crew was conducting boat drills between Minnesott and Cherry Branch with the rescue boat in the water. During this operation the rescue boat would start but would not come up to speed. [name withheld] reported that, it is possible the fuel tank had water in it due to the vent being left open. Maintenance is scheduled changing the portable fuel tank with and engine with the spare at Cherry Branch.
Once fuel tank and engine is installed conduct sea trails and send objective evidence to Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 May 2021
Resolution: Spare engine and fuel tank installed tested SAT underway.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 24 March 2021
Resolved
Light lens in engine room control booth is damaged.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 7 April 2021
Resolution: Lens was renewed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 March 2021
Resolved
Both MDE expansion tank hoses need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 23 June 2021
Resolution: Expansion tank hoses were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 March 2021
Resolved
Outboard MDE fuel hose is damaged/worn
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 29 March 2021
Resolution: Fuel hose was renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 March 2021
Resolved
Port MDE air acuator hose damaged/worn
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 29 March 2021
Resolution: Actuator hose was renewed and properly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 March 2021
Resolved
Fuel leak discovered on EDG filter; corrected on the spot
Action required: 10 - Deficiency Rectified
Due 24 March 2021
Resolved 24 March 2021
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 March 2021
Resolved
Renew submersible pump hose IWO starboard shaft bilge well.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 29 March 2021
Resolution: The hose was renewed and properly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 March 2021
Resolved
Water heater safety relief valve missing pipe.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 29 March 2021
Resolution: Pipe installed on the safety relief valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 February 2021
Resolved
Determine source of excessive oil leak on both port and stbd MDE. Make effective repairs and prove proper operation to the attendeding MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2021
Resolution: Both F/O pumps were rebuilt with new o-rings and tested with sat results.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 February 2021
Resolved
Received report of a unusual noise in astern propulsion on the STBD engine. Noise is coming appears to be coming from STBD Marine Gear. Coast Guard Sector NC has approved a one time transit to Cherry Branch for troubleshooting and permanent repairs. Once permanent repairs are conducted, test all related systems and contact CG MI for attendance of final operational testing prior to carrying passengers.
All repairs and testing are to be made to the satisfaction of attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2021
Resolution: New M/G installed and tested due to clutch failure internal.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 December 2020
Resolved
Replace fire extinguisher on rescue boat.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2020
Resolved 14 December 2020
Resolution: Fire extinguisher was renewed and properly installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 10 December 2020
Resolved
Properly plug EDG F/O vent containment
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2020
Resolved 11 December 2020
Resolution: The plug and threads were clean up and properly secured.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 December 2020
Resolved
Expired medical kit (aspirin)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2020
Resolved 4 January 2021
Resolution: The medical kit was updated with new aspirin.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 10 December 2020
Resolved
Stbd MDE lagging is loose
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2020
Resolved 11 December 2020
Resolution: The lagging was tightened up.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 10 December 2020
Resolved
#1 SSDG tachometer is not reading correctly.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2021
Resolved 29 March 2021
Resolution: Tachometer was fixed to the satisfaction of the CG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 December 2020
Resolved
EDG CO2 bottle was loose.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 10 December 2020
Resolution: To the satisfcation of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 November 2020
Resolved
Master reported the #2 ships service generator (SSDG) was found leaking through a soft patch repair, on the jacket water cooling elbow during checks. Make proper repairs (utilize in-kind parts) and carry out operation tests to ensure proper operation in accordance with manufactures specification, to the satisfaction of the coast guard inspector. Prior to carriage of passengers.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2020
Resolved 20 November 2020
Resolution: Received, reviewed, and accepted the documentation from maintenance and objective evidence. See narrative AN 7098340
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 23 March 2020
Resolved
The rescue boat davit locking tab is damaged and cracked.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2020
Resolved 30 March 2020
Resolution: Received and accepted objective evidence from company satisfying the requirement.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Lashing material
Issued 23 March 2020
Resolved
Replace forward and aft cargo netting.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2020
Resolved 30 March 2020
Resolution: Received and accepted objective evidence from company satisfying the requirement.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 23 March 2020
Resolved
The outboard rescue boat bunk is damaged.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2020
Resolved 30 March 2020
Resolution: Received and accepted objective evidence from company satisfying the requirement.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 23 March 2020
Resolved
The emergency diesel generator room door hinge pins are missing clips and loose.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2020
Resolved 30 March 2020
Resolution: Received and accepted objective evidence from company satisfying the requirement.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 March 2020
Resolved
The pilot house electrical panel, breaker #8 has a 20 amp rating. The door indicates 15 amp rating, provide clarification of proper rating.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2020
Resolved 30 March 2020
Resolution: Received and accepted objective evidence from company satisfying the requirement.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 8 January 2020
Resolved
Port fwd bulkhead engine room had a 1.5 inch hole wasted at hull plating from water sitting in the bilges.
Temp repaired discussed to be permante repaired NLT 22 Jan 2020.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 January 2020
Resolved 4 February 2020
Resolution: Witnessed final weld test of 12"x31" bulkhead insert.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 January 2020
Resolved
#1 MDE fuel return line chaffed inboard side.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 January 2020
Resolved 13 January 2020
Resolution: VSL REP provided photos of new hose installed.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 8 January 2020
Resolved
fuel bowl leaking diesel fuel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2020
Resolution: Drian plug tightened and leak stopped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 October 2019
Resolved
STBD shaft tach. not properly operating.
Action required: 705 - Other - as specified
Due 21 October 2019
Resolved 16 October 2019
Resolution: Received, reviewed, and accepted notification from company satisfying the requirement.
Engineering › Compressed Air System (control) › Fitting
Issued 6 September 2017
Resolved
On 06 September 2017 the vessels Master reported that the starboard main engine was stuck in neutral with 86 passengers onboard. The passengers were unloaded at Cherry Branch Terminal. Troubleshoot and make permanent repairs to the satisfaction of the attending marine inspector. A mechanic/technician report shall be provided attesting to the cause.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 14 September 2017
Resolution: Replaced throttle card, mother board, three air solenoids, clutch controller, multiple air tubes, drained system of water, and pressure regulator. All SAT.
Engineering › Diesel Engine (propulsion-direct drive) › Valve Actuating Gear
Issued 24 August 2017
Resolved
Company reported the starboard engine loss of RPM, during transit to the ferry terminal. Provide corrective action and proper repairs.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2017
Resolved 24 August 2017
Resolution: Recieved, reviewed, and accepted findings from master and maintenance personnel, that the throttle card and transmission valve were changed out and tested satisfactory in all modes of operation.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 22 June 2017
Resolved
Rescue Boat Davit cable crushed last 8 ft approx. Replace cable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Replaced cable with new, weight tested cable. All SAT
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 22 June 2017
Resolved
Grease and Lube davit so that it doesnt require 4 people to launch rescue boat
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Grease and lubed davit.
Engineering › Fuel Oil Service System › Filter
Issued 22 June 2017
Resolved
E-gen fuel filter leaking from lower drain.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 20 September 2017
Resolution: Installed new drain all SAT
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 22 June 2017
Resolved
Vent cover gasket needs replacing port and stbd side engine vents. (Missing and falling off)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 20 September 2017
Resolution: new gasket installed
Electrical › Electric Generation Source (service) › Generator
Issued 21 April 2017
Resolved
Air box will not close due to faulty solenoid and signal box.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 April 2017
Resolved 21 April 2017
Resolution: replaced solenoid and signal box all air box shut downs tested SAT.
Engineering › Shafting/Propeller Arrangements › Coupling Bolt
Issued 8 February 2017
Resolved
The Port Main Engine Head Bolt connected to the jackshaft failed which allowed the tailshaft to shift aft 4".
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2017
Resolved 17 February 2017
Resolution: Intermediated shaft was inspected and repaired (MISLE #6088755).
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 8 February 2017
Resolved
The Port Main Engine shaft seal failed.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2017
Resolved 17 February 2017
Resolution: Shaft seal was replaced.
Electrical › Electric Generation Source (service) › Panelboard
Issued 11 January 2017
Resolved
Port MDE alarm panel visual alarm for Low Clutch oil PSI is always alarming. Pressures are fine and audible works but visual is stuck on alarm.
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 11 January 2017
Resolution: Replaced LOW pressure switch on clutch, All SAT
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 20 October 2016
Resolved
Vessels jackshaft to tailshaft coupling was not fitted properly.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2016
Resolved 21 October 2016
Resolution: NCDOT re-fitted coupling.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 20 October 2016
Resolved
The starboard shaft seal failed due to movement in coupling.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2016
Resolved 21 October 2016
Resolution: NCDOT replaced shaft seal bellows.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 20 September 2016
Resolved
Found hole in #1 SSDG exhaust silencer at flange. Temporary repairs have been authorized and completed allowing vessel to operate with affected SSDG as standby/back up until silencer can be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2016
Resolved 12 October 2016
Resolution: Existing muffler was replaced and lagging re-installed.