Records from 1984 to 2010. Most recent: inspection, 28 September 2010.
Inspection history · 65
28 September 2010
ISPS I Exam · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3855459
1 September 2010
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3839772
7 December 2009
MARPOL Annex I Examination · NPV Safety Exam · Ballast Water Examination · ISPS I Exam · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3642869
29 July 2009
MARPOL Annex VI Survey · MARPOL Annex I Examination · NPV Safety Exam · ISPS I Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3544531
11 May 2009
ISPS I Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3472501
5 April 2009
PI Safety Exam · MARPOL Annex V Examination · ISPS I Exam · MARPOL Annex VI Survey · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3442272
2 March 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3426176
1 March 2009
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3426236
18 February 2009
MARPOL Annex V Examination · ISPS I Exam · MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3417407
14 January 2009
ISPS I Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3386975
1 January 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3387344
26 November 2008
MARPOL Annex V Examination · ISPS I Exam · MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3363964
16 November 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3364053
29 September 2008
MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · PI Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3332546
23 August 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3306306
23 August 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3308911
23 August 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3349409
22 August 2008
MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3301102
18 August 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3302459
18 August 2008
Type not recorded
No type recorded · USCGC STURGEON (WPB 87336) · USCG Northeast District (CGD-NE) · Activity 3424054
17 August 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3301104
10 July 2008
PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3214465
20 June 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3242249
11 June 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3233670
9 June 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3231992
24 May 2008
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3215146
25 April 2008
MARPOL Annex V Examination · ISPS III Exam · Deficiency Check · PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3192029
23 April 2008
ISPS III Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3190532
13 February 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3146589
12 February 2008
PI Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3146617
12 February 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3146651
24 September 2007
PI Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3064816
25 February 2007
NPV Safety Exam · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2876985
24 February 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2876976
22 February 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2876201
6 February 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2867863
29 January 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2863145
28 January 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2906022
29 July 2006
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2728757
19 June 2006
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2684917
29 July 2005
Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2444094
22 July 2005
ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2434390
6 October 2003
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1922426
31 August 2003
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1892960
13 March 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1490576
27 September 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 420853
4 January 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 411593
5 April 1997
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 402059
17 October 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 396382
29 March 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 716774
28 March 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 389398
27 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 377800
7 March 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 364996
17 June 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 520289
4 January 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 355339
26 April 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 452287
16 January 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 348282
25 September 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 346028
20 September 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 341959
15 February 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 335428
17 November 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 333575
17 November 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 326857
5 October 1987
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 318793
17 January 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 443385
13 June 1984
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 297098
Engineering › Sea-water System (primary cooling) › Piping
Issued 1 September 2010
Resolved
Vessel has pipe, not indicated on orginal class drawing, coming off fuel oil purifier cooling overboard line. Def to be rectified to satisfaction of class.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 October 2010
Resolution: Received class report attesting to the removal of the pipe from the fuel oil purifier to return the system as per original class drawing.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 1 March 2009
Resolved
The vessel reported a lost anchor at MM 90 of The Lower Mississippi River.
Action required: 705 - Other - as specified
Due 1 March 2009
Resolved 4 March 2009
Resolution: The missing anchor has been replaced with the vessels spare anchor and has been tested in all operational modes. The anchor is now fully operational as designed.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 18 February 2009
Resolved
The manhole cover, starboard side aft, on the #1 cargo hatch cover appears to have been sealed over with some form of cement. Provide attestation from classification society of repairs and proper operation.
Action required: 705 - Other - as specified
Due 25 February 2009
Resolved 4 March 2009
Resolution: The #1 cargo hold hatch cover has been unsealed, re-fitted and hose tested with satisfactory results. The hold cover is now maintaining its water tight integrity as designed.
Deck/Cargo › Holds/Tanks › Hatch
Issued 18 February 2009
Resolved
While in static operating condition, the #4 cargo hatch control device is leaking hydraulic fluid at a rate of 1 drop every five seconds. The ship's crew has taken appropriate measures to prevent pollution by soaking-up the hydraulic fluid with saw dust IAW their SOPEP manual. Make permanent repairs to the satisfaction of class.
Action required: 705 - Other - as specified
Due 4 March 2009
Resolved 4 March 2009
Resolution: The #4 cargo hold hatch control device and the #5 cargo hold forward hydraulic ram have been overhauled with all seals being changed. The hatch cover and hydraulic ram were both tested under a static operational condition with satisfactory results. They
Deck/Cargo › Holds/Tanks › Hatch
Issued 18 February 2009
Resolved
While in static operating condition, the starboard side forward hydraulic ram for the #5 cargo hatch is leaking hydraulic fluid at a rate of one drop every second. The ship's crew has taken appropriate measures to prevent pollution by soaking-up the hydraulic fluid with saw dust IAW their SOPEP manual. Make permanent repairs to the satisfaction of class.
Action required: 705 - Other - as specified
Due 4 March 2009
Resolved 4 March 2009
Resolution: The #4 cargo hold hatch control device and the #5 cargo hold forward hydraulic ram have been overhauled with all seals being changed. The hatch cover and hydraulic ram were both tested under a static operational condition with satisfactory results. They
Fire Fighting › Fire Main › Condition
Issued 14 January 2009
Resolved
The firemain was leaking between cargo holds No.1 and No.2. The pipe was deteriorated in three places, however the C/E was in the process of making repairs.
Action required: 705 - Other - as specified
Due 21 January 2009
Resolved 18 February 2009
Resolution: Received class report satisfying the requirement.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 January 2009
Resolved
The auxiliary engine sea water cooling discharge pipe had a temporary pipe patch and was leaking IWO the sewage discharge pump.
Action required: 705 - Other - as specified
Due 14 February 2009
Resolved 18 February 2009
Resolution: Received class report satisfying the requirement.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 26 November 2008
Resolved
The vessel's three generators were deigned to have a high pressure fuel leak alarm piping installed at the top of each high pressure fuel pump, connecting the leak oil tank via the high pressure leak fuel oil main pipe as per DAIHATSU Operating & Maintenance Manual (sec. 4, sheet 7). All piping connecting the high pressure leak fuel oil main pipe have been removed on all three generators. Issued 0
Action required: 705 - Other - as specified
Due 3 December 2008
Resolved 10 December 2008
Resolution: Received class report from NKK satisfying requirement.
Documentation › Certificates/Documents › IOPP Certificate
Issued 26 November 2008
Resolved
The IOPP certificate states that the vessel has a MEPC 107(49) Oil Content Meter. The Vessel had a MEPC 60(33) Oil Content Meter installed on 08 July 2008, the same day the IOPP was issued by NKK.
Action required: 705 - Other - as specified
Due 26 December 2008
Resolved 14 January 2009
Resolution: The vessel installed the MEPC 107(49) Oil Content Meter.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 29 September 2008
Resolved
The Fourth Engineer was promoted on July 27,2008, but does not have documentary proof of application for Malta flag state endorsement. Provide documentary proof of application for endorsement has been submitted to the Administration prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2008
Resolved 1 October 2008
Resolution: Received Fourth Engineer''s Endorsement from Malta Flag State for national license dated 01OCT2008.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 29 September 2008
Resolved
The incinerator could not start during the examination. The Oil [name withheld] indicated the incinerator was last used on 13SEP08, which is also the last entry on the Oil Record Book. The vessel has enough capacity to retain dirty oil on board for it's intended voyage.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2008
Resolved 30 September 2008
Resolution: Received class report from NKK satisfying the requirement.
Documentation › Logs/Records › Oil Record Book
Issued 29 September 2008
Resolved
The last entry on the Oil Record Book was on 13 SEP 08. The Oil Record Book Part I should be recorded on each occasion, in accordance with (MARPOL Annex I Reg 17).
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 October 2008
Resolved 26 November 2008
Resolution: Oil Record Book inspected satisfactory.
Engineering › Diesel Engine (propulsion-direct drive) › Valve, Pilot (air start)
Issued 23 August 2008
Resolved
Pneumatic cylinder number two of the M/E reversing system was in poor condition and dirty.
Action required: 705 - Other - as specified
Resolved 25 August 2008
Resolution: Received report from Classification Society rectifying the deficiency.
Navigation › Piloting/Steering › Gyro Compass
Issued 20 June 2008
Resolved
Vessel granted deviation for inop Gyro Compass.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 June 2008
Resolved 20 June 2008
Resolution: Received Tech report satisfying requirement.
Construction/Loadline › Hull › Hull Plating
Issued 25 April 2008
Resolved
Inspection occured while vessel was conducting extensive repairs as a result of a marine casualty and prior to dry dock in Tampa, FL. Vessel must have attending classification society attest to satisfaction of repairs prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 April 2008
Resolved 26 April 2008
Resolution: Received documentation from NKK satisfying requirements.
Construction/Loadline › Hull › Hull Plating
Issued 12 February 2008
Resolved
Following breakaway from dock, vessel collided with another vessel causing damage to port side of transom. There is an opening in the hull approx. 2 foot by 4 foot 30 feet above the waterline.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 25 April 2008
Resolution: Received class report satisfying the requirement.
Construction/Loadline › Hull › Side Shell
Issued 12 February 2008
Resolved
Following breakaway from dock, vessel collided with another vessel causing damage to port side between frames 10 and 20. There are several tripped frames and drain pipes involved.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 25 April 2008
Resolution: Received class report satisfying the requirement.
Construction/Loadline › Hull › Hull Plating
Issued 12 February 2008
Resolved
Following breakaway from dock, vessel grounded bow first into levee revetment causing damage to the bulbous bow. There are several insets and a hole on the port side of bulbous bow near midline approx. 10 inches by 2 inches one foot above waterline.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 25 April 2008
Resolution: Received class report satisfying the requirement.
Construction/Loadline › Hull › Hull Plating
Issued 12 February 2008
Resolved
Vessel must provide complete damage survey and repair proposal prior to movement from Andry St. Warf.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2008
Resolution: Received class report satisfying the requirement.
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 12 February 2008
Resolved
During severe weather, vessel broke away from repair dock. There were seven mooring lines forward and seven mooring lines aft that all parted.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 24 May 2008
Resolution: Cleared with proper documentation.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 27 February 2007
Resolved
The bilges were full of oily water and that the high level alarms were silenced.
Action required: 705 - Other - as specified
Due 27 February 2007
Resolved 28 February 2007
Resolution: Received class report from NKK satisfying requirement.
Operations/Management › Drills/Instruction › Fire
Issued 25 February 2007
Resolved
While conducting fire drill the crew was unable to demonstrate proficiency with firefighting procedures during an initial and follow-up drill. The team leader was also unable to provide a muster sheet for the fire and abandon ship drills.
Action required: 705 - Other - as specified
Due 25 February 2007
Resolved 27 February 2007
Resolution: The crew provided muster list and demonstrated proficiency in firefighting.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 25 February 2007
Resolved
The incinerator is not operating as designed.
Action required: 705 - Other - as specified
Due 25 February 2007
Resolved 28 February 2007
Resolution: Received class report from NKK satisfying requirement.
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 July 2005
Resolved
The starboard side of the sea water / air cooer outlet pipe has a temporary patch. Make permanent repairs to the satisfaction of the classification society.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 29 July 2005
Resolution: Received class report from NKK satisfying requirement.
Engineering › Freshwater Generation System › Piping
Issued 22 July 2005
Resolved
The freshwater generator has a temporary patch on the dischare line under the generator. Make permanent repairs to satisfaction of classification society.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 29 July 2005
Resolution: Received class report from NKK satisfying requirement.
Lifesaving
Issued 28 March 1996
Resolved
Provide dimension markings and a means of identifying each lifeboat for both the port and starboard lifeboats IAW SOLAS chapter III, regulation 41.9.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Lifesaving
Issued 28 March 1996
Resolved
Properly mount all self igniting lights. Vessel has a total complement of 8 lifebuoys. 4 are required to have self igniting IAW SOLAS chapter III, regulation 7.1.3. One was mounted to a hand rail but not attached to the life buoy, the other was stored in a locker in a non-operational mode.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Documentation
Issued 28 March 1996
Resolved
The M/V AURORA EMERALD was in violation of 33 CFR 151.25(h) when several completed pages of the oil record book were not signed by the Master.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Documentation
Issued 17 November 1989
Resolved
VESSEL FAILED TO MEET THE REQUIREMENTS OF 33 CFR 151.25(D)(3) NO ENTRIES WERE MADE IN PART 1 OF THE OIL RECORD BOOK OF DISPOSAL OF OILY RESIDUE RETAINED ONBOARD FOR DISPOSAL TO RECEPTION FACILITY OR BURNED THROUGH INCENERATOR. VSL'S GROSS TONS ARE 19,882.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Documentation
Issued 17 November 1989
Resolved
VESSEL'S OIL TRANSFER PROCEDURES DID NOT CONTAIN THE PROCEDURES FOR REPORTING OIL DISCHARGES INTO THE WATER AS REQUIRED BY 33 CFR 155.750(A)(9)OIL CAPACITY IS 11881.1 BBLS.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Documentation
Issued 17 November 1989
Resolved
VESSEL'S OIL TRANSFER PROCEDURES WERE MISSING PROCEDURES FOR TOPPING OFF TANKS AS REQUIRED BY 33 CFR 155.750(A)(7). OIL CAPACITY IS 11881.1 BBLS.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Documentation
Issued 17 November 1989
Resolved
VESSELS OIL TRANSFER PROCEDURES DID NOT CONTAIN THE NUMBER OF PERSONS REQUIRED TO BE ON DUTY DURING OIL TRANSFER OPERATIONS AS REQUIRED BY 33CFR 155.750(A)(3). OIL CAPACITY IS 11881.1 BBLS.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Documentation
Issued 17 November 1989
Resolved
VESSEL'S OIL TRANSFER PROCEDURES DID NOT CONTAIN THE PROCEDURES AND DUTY ASSIGNMENTS FOR TENDING VESSEL'S MOORINGS DURING THE TRANSFER OF OIL AS REQUIRED BY 33 CFR 155.750(A)(5). OIL CAPACITY IS 11881.1 BBLS.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Documentation
Issued 17 November 1989
Resolved
VESSEL'S OIL TRANSFER PROCEDURES DID NOT CONTAIN CARGO INFORMATION DESCRIBED IN 33 CFR 154.310(A)(5)(II) AS REQUIRED BY 33 CFR 155.750(A)(1)- (II). OIL CAPACITY IS 11881.1 BBLS.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Documentation
Issued 17 November 1989
Resolved
VESSEL'S OIL TRANSFER PROCEDURES DID NOT CONTAIN PROCEDURES FOR ENSURING ALL VALVES USED DURING OIL TRANSFER ARE CLOSED UPON COMPLETION OF TRANSFER AS REQUIRED BY 33 CFR 155.750(A)(8). OIL CAPACITY IS 11881.1 BBLS.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Navigation
Issued 17 November 1989
Resolved
VESSEL TRANSITED PUGET SOUND WATERS UTILIZING CHARTS NOT CURRENTLY CORRECTED WITH CHANGES CONTAINED IN NOTICE TO MARINERS AS REQUIRED BY 33CFR164.33(A)(1)(II) OR EQUIVALENT FOREIGN GOVERNMENT CHARTS IN ACCORDANCE WITH 33 CFR 164.33(B).
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Documentation
Issued 17 November 1989
Resolved
VESSEL'S OIL TRANSFER PROCEDURES DID NOT CONTAIN THE PROCEDURES FOR OPERATING THE MEANS OF COMMUNICATIONS AS REQUIRED BY 33 CFR 155.750(A)(6). OIL CAPACITY IS 11881.1 BBLS.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Documentation
Issued 17 November 1989
Resolved
VESSEL'S OIL TRANSFER PROCEDURES DID NOT CONTAIN DUTIES BY TITLE OF EACH PERSON REQUIRED FOR TRANSFER OPERATIONS AS REQUIRED BY 33 CFR 155.750(A)- (4). OIL CAPACITY IS 11881.1 BBLS.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Navigation
Issued 17 November 1988
Resolved
VESSEL TRANSITED PUGET SOUND WATERS WITH COAST GUARD LIGHT LIST NOT CURRENTLY CORRECTED WITH CHANGES CONTAINED IN NOTICE TO MARINERS AS REQUIRED BY 33 CFR 164.33(A)(2)(II) OR AN EQUIVALENT FOREIGN GOVERNMENT PUBLICATION IAW 33 CFR 164.33(B)
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Documentation
Issued 17 November 1988
Resolved
VESSEL FAILED TO MEET THE REQUIREMENTS OF 33 CFR 151.25(K) IN THAT THE OIL RECORD BOOK WAS NOT MAINTAINED ON BOARD FOR A PERIOD OF NOT LESS THAN 3 YEARS.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Navigation
Issued 17 November 1988
Resolved
VESSEL TRANSITED PUGET SOUND WATERS WITH US COAST PILOT #7 NOT CURRENTLY CORRECTED WITH CHANGES CONTAINED IN NOTICE TO MARINERS AS REQUIRED BY 33 CFR 164.33(A)(2)(I) OR EQUIVALENT FOREIGN GOVERNMENT PUBLICATION IN ACCORDANCE WITH 33 CFR 164.33(B)
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Navigation
Issued 17 November 1988
Resolved
VESSEL TRANSITED PUGET SOUND WATERS UTILIZING CHARTS NOT CURRENTLY CORRECTED WITH CHANGES CONTAINED IN NOTICE TO MARINERS AS REQUIRED BY 33 CFR 164.33(A)(1)(II) OR EQUIVALENT FOREIGN GOVERNMENT CHARTS IN ACCORDANCE WITH 33 CFR 164.33(B)
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Navigation
Issued 5 October 1987
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE US CHARTS 12230, 12264, & 12281 USED BY THE VSL, WERE NOT CURRENTLY CORRECTED VIA NTMS, WHICH WERE REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPOLICABLE TO THE VSLS ROUTE FROM SMITH POINT VA, TO BALTIMORE HARBOR. NO FOREIGN EQUIV O/B.
Condition: Unknown
Due 5 October 1987
Resolved 5 October 1987
Navigation
Issued 5 October 1987
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE USCG LIGHT LIST USED BY THE VSL WAS NOT CURRENTLY CORRECTED VIA NTMS, WHICH WERE REASONABLY AVAILABLE AND CONTAINEDCORRECTIONS APLLICABLE TO THE VSLS ROUTE FROM SMITH POINT, VA TO BALTIMORE HARBOR. NO CORRECTED FOREIGN EQUIVALENT ON BOARD.
Condition: Unknown
Due 5 October 1987
Resolved 5 October 1987
Documentation
Issued 5 October 1987
Resolved
A VIO OF 33 CFR 155.720 IN THAT THE OIL TRANSFER PROCEDURES ON BOARD DID NOT MEET THE REQUIREMENTS OF 33 CFR 155.750. OIL CAPACITY 11881.1 BBLS
Condition: Unknown
Due 5 October 1987
Resolved 5 October 1987