Records from 1989 to 2014. Most recent: inspection, 6 March 2014.
Inspection history · 43
6 March 2014
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4811091
14 February 2012
Drydock Exam · Examination of Repairs · Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4245483
1 February 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4235891
2 December 2010
MTSA Verification · Administrative Inspection · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3902852
19 April 2008
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3194269
13 February 2008
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3147047
14 January 2008
MTSA Verification · Annual Inspection · Examination of Repairs · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3130352
17 January 2007
Hull Examination · Ballast Water Examination · MTSA Verification · Examination of Repairs · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2857110
25 May 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2658903
8 December 2005
MTSA Verification · COI Inspection · Ballast Water Examination · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2548108
1 November 2005
Deadweight Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2526508
23 December 2004
Ballast Water Examination · Hull Examination · MTSA Verification · Examination of Repairs · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2263974
30 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1982287
22 December 2003
Re-Inspection · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1968254
1 May 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1961461
24 February 2003
Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1748704
22 February 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1750832
6 February 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1740667
5 November 2001
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1475995
8 June 2001
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437909
17 January 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 84597
24 October 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457839
22 October 1999
Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1449238
7 October 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449107
22 December 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428874
28 October 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1359295
11 October 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 841074
1 September 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387843
1 September 1994
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358508
10 March 1994
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1165310
16 September 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1356421
14 September 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1256826
11 September 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 945926
10 October 1991
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1243610
23 September 1991
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 937652
6 August 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 670569
20 October 1990
Re-Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1214776
4 October 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1230282
20 July 1990
Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238431
7 May 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1216769
22 February 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927708
17 January 1990
Deficiency Check · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1240198
22 August 1989
Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899241
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 February 2012
Resolved
Complete man overboard, fire, abandon ship drill to the satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Resolved 28 March 2012
Resolution: completed.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 14 February 2012
Resolved
Prove proper operation of generator overspeed trip.
Action required: 705 - Other - as specified
Resolved 28 March 2012
Resolution: completed.
Stability › Freeing Ports › General
Issued 8 December 2005
Resolved
Master to demonstrate ability to perform stability calc's as required by vessel's ops manual.
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 16 January 2007
Resolution: Provided
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 8 December 2005
Resolved
Provide automation test procedures to local OCMI for approval.
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 16 January 2007
Resolution: Provided
Documentation › Manuals/Policy Documentation › Operations Manual (Incinerator)
Issued 8 December 2005
Resolved
Provide updated operations manual to reflect vessel as currently outfitted.
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 16 January 2007
Resolution: Provided
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 23 December 2004
Resolved
Provide remote propulsion controls as required by NVIC 1-78.
Action required: 705 - Other - as specified
Due 23 January 2005
Resolved 8 December 2005
Stability › Intact Stability (when using lifting gear) › General
Issued 22 December 2003
Resolved
Stability and Structure calculations shall be made on the newly installed stbd deck crane. Calculations shall be forwarded to MSC for final approval. The cranes shall remain in the stowed position at all times while the vessel is underway or jacked-up until approval is received by MSC. LEGACY COMPONENT DESC: stbd deck crane
Due 20 February 2004
Resolved 23 December 2004
Stability › Intact Stability (when using lifting gear) › General
Issued 22 December 2003
Resolved
The vessel's operating manual shall be updated and approved prior to using the new crane. LEGACY COMPONENT DESC: liftboat operations manual
Due 20 February 2004
Resolved 23 December 2004
Resolution: MSC approved operations manual dated 22DEC04 on board.
Deck/Cargo › Mooring/Anchoring
Issued 24 February 2003
Resolved
Anchor chain broke (wasted) and anchor was lost. Issued CG-835 for vsl to obtain an anchor prior to departure. LEGACY COMPONENT DESC: Anchor
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2003
Resolution: Vsl obtained anchor and chain. Cleared for departure.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 6 February 2003
Resolved
PROVIDE OILY WASTE FIXED PIPING AND PUMP AS REQUIRED BY 33 CFR 155.420.
Action required: 705 - Other - as specified
Due 6 March 2003
Resolved 23 December 2004
Navigation › Piloting/Steering
Issued 24 October 2001
Resolved
Rudder angle indicator inop. LEGACY COMPONENT DESC: Steering Magnetic Compass
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2001
Lifesaving › Rescue Boat
Issued 24 October 2001
Resolved
No retroreflective tape on btm. of rescue boat. LEGACY COMPONENT DESC: Markings
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2001
Communications › Alarms/Indicators
Issued 24 October 2001
Resolved
Rudder angle indicator inop. LEGACY COMPONENT DESC: Rudder Angle Indicator
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2001
Engineering › Fuel Oil Service System
Issued 24 October 2001
Resolved
Stbd. fuel oil reach rod inop. LEGACY COMPONENT DESC: Valve, Control
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2001
Construction/Loadline › Hull
Issued 24 October 2001
Resolved
2'x2'x1/4" btm. plate renewed amid. at the headlog. LEGACY COMPONENT DESC: Bottom Plating
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2001
Construction/Loadline › Hull
Issued 24 October 2001
Resolved
Stbd. sponson btm. pl. holed; renew 18"x18"x1/4". LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2001
Construction/Loadline › Hull
Issued 24 October 2001
Resolved
Cargo deck wasted. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2001
Electrical
Issued 22 October 1999
Resolved
HARDWIRE MSD PUMP MOTOR AND WELDING MACHINE.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Engineering
Issued 22 October 1999
Resolved
RENEW ALL CRACKED/CHAFED HOSES ON P/S MAIN ENGINES, GENERATORS, AND HYDRAULIC PUMP ENGINE.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Unknown
Issued 22 October 1999
Resolved
PROPERLY REPAIR/RENEW MSD TANK AND PIPING.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Lifesaving
Issued 22 October 1999
Resolved
RENEW/REPLACE DRYER VENT EXHAUST WITH METAL TUBING.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Lifesaving
Issued 22 October 1999
Resolved
RENEW/PROVIDE ON BOARD VESSEL A RESCUE BOAT IN ACCORDANCE WITH REQUIREMENTSOUTLINED IN D8 POLICY LETTER (16613) DATED 12NOV98.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Electrical
Issued 22 October 1999
Resolved
PROPERLY STRAP ALL LOOSE ELECTRICAL WIRES/CABLES.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Fire Fighting
Issued 22 August 1989
Resolved
PROVIDE B-V FIRE EXTINGUISHERS FOR HELO PORT & MAKE REPAIRS TO ALL WIRING FOR LIGHTS ON HELO PORT - HELO PORT IS NOT TO BE USED UNTIL ITEMS COMPLETED.
Condition: Unknown
Due 22 August 1989
Resolved 22 August 1989
Lifesaving
Issued 22 August 1989
Resolved
PROVIDE 500 FEET OF AUXILARY LINE AS REQUIRED BY 46 CFR 94.45-15(B)(6) FOR LINE THROWING GUN.
Condition: Unknown
Due 22 August 1989
Resolved 22 August 1989
Documentation
Issued 22 August 1989
Resolved
SUBMIT OPERATING MANUAL FOR APROVAL.
Condition: Unknown
Due 22 August 1989
Resolved 22 August 1989
Lifesaving
Issued 22 August 1989
Resolved
INSTALL A SUITABLE RESCUE BOAT AND UPON COMPLETION, MAKE INSTALLATION AVAILABLE FOR INSPECTION BY AN ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 22 August 1989
Resolved 22 August 1989
Lifesaving
Issued 22 August 1989
Resolved
INSTALL A SUITABLE MEANS OF ESCAPE.
Condition: Unknown
Due 22 August 1989
Resolved 22 August 1989
Documentation
Issued 22 August 1989
Resolved
SUBMIT FOR APPROVAL PLANS SHOWING GENERAL ARRANGEMENT, INBOARD/OUTBOARD PROFILE, FIRE CONTROL PLAN AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS TO THE [name withheld].
Condition: Unknown
Due 22 August 1989
Resolved 22 August 1989