Records from 1985 to 2012. Most recent: inspection, 16 February 2012.
Inspection history · 33
16 February 2012
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4245565
12 December 2011
ISPS II Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4208035
23 September 2008
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3331096
4 October 2007
PI Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3070674
4 October 2007
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3072983
19 July 2007
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3001649
29 June 2007
MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2977890
25 May 2006
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2658586
24 November 2004
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2247512
4 November 2004
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2235051
30 August 2004
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2182235
12 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1982752
9 October 2003
Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1924961
27 August 2003
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1889647
18 November 2002
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1708523
13 September 2002
Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1695056
13 June 2002
Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1630585
1 June 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471768
17 January 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 84597
27 April 2000
Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1444316
24 February 2000
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 816186
8 July 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 179592
3 June 1999
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1411891
6 August 1998
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1442734
21 January 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1113997
13 January 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 37796
13 June 1997
Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1448922
19 December 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 754885
18 December 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 197811
25 May 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 668346
22 May 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 136844
10 July 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1014269
1 November 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1293096
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 23 September 2008
Resolved
Owner/operator failed to prepare and submit a nontank vessel response plan IAW 33 U.S.C 1321(j)(5).
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 October 2008
Resolved 26 October 2009
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 7 October 2007
Resolved
SMS not implemented. Concur with Administrations request for audit to be carried out within four weeks of 06OCT2007. Audit shall be conducted by ISM issuing authority. SOLAS 2004 CH IX
Due 4 November 2007
Resolved 26 October 2009
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 4 October 2007
Resolved
The master is unfamiliar with the ship's safety management procedures and responsibilities. Since issuance of the SMC (8JUN07) the safety management system has not been implemented as evidenced by the lack of documentation to address required maintanence and repairs to critical equipment aboard the vessel as required by the ISM Code 5 and Code 10. SOLAS 2004 Cons. Ch IX Reg 5. To Admin.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2007
Resolution: A representative from DNV conducted an ISM audit and provided documentation to the CG clearing the deficiency.
Construction/Loadline › Penetrations › Gasket
Issued 4 October 2007
Resolved
Six of Seven (86%) of the watertight doors do not seal properly due to mis-allignment, imporperly installed gaskets, and lack of preventative maintenance. The port main deck hatch is not watertight as evidenced by light leaks from the hatch cover/coaming interface and installation of an air conditioner unit through a hole cut into the outboard side of the coaming. SOLAS60 Ch. II Reg 17 To Admin
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2007
Resolution: A DNV class representative submitted a class report rectifying the def. on behalf of the Honduras Admin.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 4 October 2007
Resolved
Three of Four engine room ventilation closures do not seal properly due to wasted and corroded knife edges and missing gasket material. The engine room ventilation cannot be sealed in the event of a fire. SOLAS 60 Ch II Reg 47 (A) Rectify to the sat of the Administration.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2007
Resolution: A DNV class representative submitted a class report rectifying the def. on behalf of the Honduras Admin.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 4 October 2007
Resolved
Installation of the 5 foot by 3 foot transformer for underwater research sound equipment in crew berthing is an electrical hazard. SOLAS 60 Ch II Reg 23 Rectify to the satisfaction of the Coast Guard Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2009
Engineering › Steering Gear System › Ram
Issued 4 October 2007
Resolved
The steering gear components appear to be worn causing jerky operation. Suspect RAM pad-eye wastage. SOLAS 60 Ch. II Reg 29 (a)(i) Rectify to the satisfaction of the administration.
Due 4 November 2007
Resolved 26 October 2009
Engineering › Feedwater/Condensate Water System › Piping
Issued 4 October 2007
Resolved
A wooden dowel is used in place of a mechanical fitting and gauge in the fresh water ballast water cross-piping in the engine room. Piping no longer meets design standards. SOLAS 2004 Cons. Ch II-1 Reg 26.1 Rectify to the sat of the Administration.
Condition: Placed in Improper Service
Due 4 November 2007
Resolved 26 October 2009
Electrical › Electrical Distribution System (service) › Switchboard
Issued 4 October 2007
Resolved
There are exposed circuits on the face of the main electrical distribution panel. SOLAS 60 Ch II Reg 27
Rectify to the satisfaction of the Coast Guard Inspector.
Condition: Improper/Lack of Maintenance
Due 4 November 2007
Resolved 26 October 2009
Electrical › Electric Supply System (service) › Battery Installation
Issued 4 October 2007
Resolved
The starting battery for the port generator is resting unprotected and unsecured on the engineroom passageway. SOLAS 60 Ch. II Reg 23 (a) (i) Rectify to the sat of the Coast Guard Inspector.
Due 4 November 2007
Resolved 26 October 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 4 October 2007
Resolved
Three light installations in the engine room and one in the stbd toilet are missing protective globes. SOLAS 60 Ch II Reg 27(a)(v) Rectify to the sat of the Coast Guard Inspector.
Condition: Improper/Lack of Maintenance
Due 4 November 2007
Resolved 26 October 2009
Engineering › Freshwater System (intermediary cooling) › Storage Tank
Issued 4 October 2007
Resolved
The engine water cooling tank above the port main engine is bulging on top and the front and is severely pitted on the aft bottom face. SOLAS 2004 Cons. Ch I Reg 11(a) Rectify to the sat of the Administration.
Condition: Unknown
Due 4 November 2007
Resolved 26 October 2009
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 October 2007
Resolved
The port generator foward machinery guard is missing. SOLAS 2004 Cons. Ch I Reg 11 (a)
Rectify to the sat of the Coast Guard Inspector.
Condition: Unknown
Due 4 November 2007
Resolved 26 October 2009
Fire Fighting › Fire Hydrants › Material
Issued 4 October 2007
Resolved
The fire station spanner wrenches are improperly sized for the nozzles. SOLAS 60 Ch II Reg 55(f)
Rectify to the sat of the Coast Guard Inspector
Condition: Unknown
Due 4 November 2007
Resolved 26 October 2009
Engineering › Steering Gear System › Chain
Issued 19 July 2007
Resolved
EMERGENCY STEERING TACKLE NOT IN GORKI9NG ORDER VESSEL CANNOT SAIL UNTIL REPLACED
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2009
Resolved 26 October 2009
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 29 June 2007
Resolved
SHIP SAFETY RADIO CERTIFICATE EXPIRED MAY 2007.
Action required: 15 - Rectify deficiencies by next port
Due 5 July 2007
Resolved 19 July 2007
Resolution: NEW SSRC ONBOARD VESSEL
Communications › Radio Communications › Satellite Communications Capability
Issued 29 June 2007
Resolved
GMDSS UNIT NOT INSTALLED
Action required: 15 - Rectify deficiencies by next port
Due 5 July 2007
Resolved 19 July 2007
Resolution: GMDSS INSTALLED AND APPROVED BY FLAG
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 29 June 2007
Resolved
RESCUE BOAT FOUND ON DECK WITH NO ENGINE, MEANS OF LAUNCH, OR PROVISIONS.
Action required: 15 - Rectify deficiencies by next port
Due 5 July 2007
Resolved 19 July 2007
Resolution: RESCUE BOAR FOUND TO BE IN COMPLIANCS WITH LSA CODE
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 29 June 2007
Resolved
DID NOT HAVE COMPLETE SET FOR FIRESUIT REQUIREMENTS.
Action required: 15 - Rectify deficiencies by next port
Due 5 July 2007
Resolved 19 July 2007
Resolution: VESSEL OUTFITTED WITH ALL FFE REQUIRED
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 29 June 2007
Resolved
VESSEL DID NOTHAVE PROPER COMMUNICATIONS BETWEEN BRIDGE AND EMERGENCY STEERING. VESSEL DID NOT HAVE COMPLETE SET OF CHAIN FALLS FOR EMERGENCY STEERING.
Action required: 15 - Rectify deficiencies by next port
Due 5 July 2007
Resolved 19 July 2007
Resolution: COMMS BETWEEN BRIDGE AND STEERING GEAR ROOM ESTABLISHED AND ACCEPTABLE
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 29 June 2007
Resolved
NO WRITTEN CORRESPONDENCE WITH COMPANY OF DPA FOR OPERATIONAL MAINTENANCE.
Action required: 15 - Rectify deficiencies by next port
Due 5 July 2007
Resolved 19 July 2007
Construction/Loadline › Markings › Load Line Assigning Authority Mark
Issued 29 June 2007
Resolved
ACTUAL LOADLINE MARKINGS DID NOT MATCH CERTIFICATE ISSUED MARKS. NO DECKLINE FOUND.
Action required: 15 - Rectify deficiencies by next port
Due 5 July 2007
Resolved 19 July 2007
Resolution: LOADLINE MARKINGS IN COMPLIANCE WITH LOADLINE CERT
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 29 June 2007
Resolved
Fire control plan is not approved by flag and not kept with muster list
Action required: 15 - Rectify deficiencies by next port
Due 17 August 2007
Resolved 26 October 2009
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 29 June 2007
Resolved
NO BALLAST WATER PLAN ONBOARD.
Action required: 15 - Rectify deficiencies by next port
Due 5 July 2007
Resolved 19 July 2007
Resolution: BWP ONBOARD AND APPROVED BY FLAG
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 29 June 2007
Resolved
NO MEDICAL EXAM FORMS FOR ANY CREWMEMBERS ONBOARD.
Action required: 15 - Rectify deficiencies by next port
Due 5 July 2007
Resolved 19 July 2007
Resolution: ALL PERSONNEL HAVE MEDICAL FORMS AND ARE CLEAR TO SAIL
Operations/Management › Pollution › Retention of Oily Mixture
Issued 30 August 2004
Resolved
Remove excess oil from engine room bilge.
Due 28 September 2004
Resolved 27 September 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 August 2004
Resolved
Repair Anchor Light.
Due 27 September 2004
Resolved 27 September 2004
Engineering › Steering Gear System › Rudder Stock
Issued 30 August 2004
Resolved
Re-pack port rudder post to prevent the ingress of water.
Due 28 September 2004
Resolved 27 September 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 30 August 2004
Resolved
Replace missing/damaged light covers in engine/generator rooms.
Due 28 September 2004
Resolved 27 September 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 27 August 2003
Resolved
Prior to sailing repair leaking lube oil supply line to turbocharger.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2003
Resolution: Turbo lube oil supply line was replaced.
Engineering › Fuel Oil Service System › Piping
Issued 27 August 2003
Resolved
Prior to sailing repair fuel oil leak outboard side low pressure pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2003
Resolution: Fuel oil line was loose which was corrected prior to departure.
Engineering › Bilge Water Management System
Issued 27 August 2003
Resolved
Prior to sailing have bilges in engineroom, bow thruster room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2003
Resolution: Environmental equipment company removed all excess bilge slops.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 27 August 2003
Resolved
Repair minor Jacket water leak inboard number one main.
Action required: 705 - Other - as specified
Due 27 September 2003
Resolved 25 September 2003
Resolution: Repaired jacket water leak according to technicians report.
Engineering › Steering Gear System
Issued 27 August 2003
Resolved
Repair Starboard rudder packing.
Action required: 705 - Other - as specified
Due 27 September 2003
Resolved 25 September 2003
Resolution: Written statement form the master of the vessel attesting to the repacking of the satrboard rudder.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 15 July 2002
Resolved
PROVE PROPER OPERATION OF JACKET WATER AND LUBE OIL GUAGES FOR MAIN DIESEL ENGINES. GUAGES ARE ON BRIDGE.
Due 15 August 2002
Resolved 18 November 2002
Electrical › Electrical Distribution System (service)
Issued 15 July 2002
Resolved
REMOVE DEAD END WIRES UNDER BRIDGE CONSOLE AND IN OVERHEAD. LEGACY COMPONENT DESC: Wiring
Due 15 August 2002
Resolved 18 November 2002
Electrical › Lighting (service)
Issued 15 July 2002
Resolved
PROVIDE LIGHT COVERS FOR OVERHEAD LIGHTS ON BRIDGE AND LOWER RACK STBD FWD.
Due 15 August 2002
Resolved 18 November 2002
Fire Fighting › Miscellaneous Items
Issued 15 July 2002
Resolved
RENEW INSTRUCTIONS FOR ALL FIXED FIRE PORTECTED SPACES TO INCLUDE "CLOSE VENT"
Due 15 August 2002
Resolved 18 November 2002
Construction/Loadline › Hull
Issued 15 July 2002
Resolved
REPAIR HOLE INBOARD OF STARBOARD EXHAUST STACK.
Due 15 August 2002
Resolved 18 November 2002
Engineering › Freshwater System (jacketwater cooling)
Issued 15 July 2002
Resolved
MAKE PERMANENT REPAIRS TO PORT MDE FRESH WATER SYSTEM ON TANK AND PIPING, IN WAY OF TEMPORARY REPAIRS. LEGACY COMPONENT DESC: Piping
Due 15 August 2002
Resolved 18 November 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 15 July 2002
Resolved
RENEW LAGGING ON PORT MDE NEAR TURBOCHARGER.
Due 15 August 2002
Resolved 18 November 2002
Engineering › Generator (propulsion-electric)
Issued 15 July 2002
Resolved
REPAIR TACHOMETER ON STBD GENERATOR.
Due 15 August 2002
Resolved 18 November 2002
Engineering › Fuel Oil Service System
Issued 15 July 2002
Resolved
REMOVE PETCOCK FROM FUEL FILTER ON THE BOW THRUSTER ENGINE. LEGACY COMPONENT DESC: Filter
Due 15 August 2002
Resolved 18 November 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 15 July 2002
Resolved
PROVE PROPER OPERATION OF STBD MDE SHUTDOWN ON BRIDGE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 July 2002
Construction/Loadline › Hull › Hull Plating
Issued 15 July 2002
Resolved
REPAIR CRACK NEAR INSERT AT TURN ON 14 STARBOARD.
Due 15 July 2002
Resolved 15 July 2002
Documentation
Issued 1 June 2001
Resolved
PROVIDE APPROVED VESSEL PLANS TO THE COAST GUARD TO THE SATISFACTION OF THECOGNIZANT OFFICER IN CHARGE MARINE INSPECTIONS.
Condition: Unknown
Due 1 November 2001
Resolved 18 November 2002
Construction/Loadline
Issued 24 February 2000
Resolved
MAKE PERMANENT REPAIRS TO PORTSIDE FORWARD BULWARK AND FORE MAST. AS AGREEDBY OPERATIONS MANAGER VESSEL WILL BE IN DRYDOCK NOT LATER THAN 30 MARCH 00 FOR CREDIT DRYDOCK EXAM.
Condition: Unknown
Due 24 February 2000
Resolved 24 February 2000
Lifesaving
Issued 13 June 1997
Resolved
PROVIDE COPY OF EPIRB REGISTRATION STICKER.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Lifesaving
Issued 13 June 1997
Resolved
PROVIDE LIFESAVING SIGNAL PLACARD (CG-811).
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Construction/Loadline
Issued 13 June 1997
Resolved
REPAIR/REPLACE WASTED RAIL POST LOCATED ON 2ND DECK, AFT, STBD SIDE.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Construction/Loadline
Issued 13 June 1997
Resolved
PROVIDE BALL CHECK VALVE FOR FOREPEAK VENT, STARBOARD SIDE, FORWARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Construction/Loadline
Issued 13 June 1997
Resolved
CROP AND RENEW WASTED TRANSVERSE UNDERDECK STIFFENER IN WAY OF HATCH, STARBOARD SIDE, FRAME 12.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Lifesaving
Issued 13 June 1997
Resolved
PROVIDE LIFE RAFT EMBARKATION LADDERS.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Fire Fighting
Issued 13 June 1997
Resolved
FINALIZE, AND SUBMIT FOR CG APPROVAL, FIRE AND SAFETY PLAN.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Construction/Loadline
Issued 13 June 1997
Resolved
SUBMIT PROPOSAL FOR CHAIN LOCKER DRAIN MODIFICATION.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997