Records from 1981 to 2016. Most recent: inspection, 9 May 2016.
Inspection history · 51
9 May 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5872339
17 August 2015
Deficiency Check · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5218499
22 February 2011
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3949846
14 February 2011
Examination of Repairs · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3945317
5 October 2010
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3864648
12 September 2006
Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2776716
23 August 2006
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2757592
7 June 2006
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2674037
5 November 2005
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2532168
3 November 2005
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2530154
16 June 2005
Ballast Water Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2392235
13 September 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2194577
12 June 2003
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1815564
24 September 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1679635
18 June 2001
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1384731
17 January 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 84597
19 June 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403169
28 June 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 724328
27 May 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399136
1 March 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 214998
1 March 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 692488
25 September 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 692487
13 July 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 174189
13 July 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 214103
17 June 1998
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473228
27 May 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214977
17 July 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450055
29 June 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1113149
9 April 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447569
16 March 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 34592
27 February 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401993
23 August 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 870693
25 March 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1432805
15 March 1993
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415802
11 October 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 188581
1 July 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 654427
23 April 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 654426
2 March 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 947828
24 April 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1225821
28 March 1991
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 911167
1 March 1990
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1230177
23 February 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1196819
17 January 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1208141
2 March 1988
Deficiency Check · Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1347028
19 February 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015541
12 May 1986
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 989223
15 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983971
16 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279488
10 November 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971103
18 February 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969528
6 August 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964541
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 May 2016
Resolved
Found multiple spliced wiring in pilot house underneath consoles. Splices need to be made in accordance with stated cite (46 CFR 111.60-13(b)(c))
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 9 May 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 May 2016
Resolved
Found multiple twist on type connectors in pilot house underneath console. Termination of connectors need to be made in accordance with stated cite (46 CFR 111.60-17(b)(c)).
Condition: Improper Installation
Due 6 June 2016
Resolved 9 May 2016
Engineering › Fuel Oil Service System › Piping
Issued 15 February 2011
Resolved
Stbd fule piping IWO emergency fuel shut off valve was leaking fuel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 February 2011
Resolution: Vessel replaced valve.
Stability › Watertight Integrity › General
Issued 14 February 2011
Resolved
Found water leaking into E/R bilge from a crack approx 4 inches below port shaft log. Crack was 2" x 1/4". Port Capt to provide temp repair prior to transiting to Morgan City for drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2011
Resolved 19 February 2011
Resolution: Vessel replaced bulkhead around the shaft.
Engineering › Bilge Water Management System › Manifold
Issued 14 February 2011
Resolved
Inspection revealed a 1" dia hole in bilge pump suction piping. Port Capt to provide temp repair prior to transiting to Morgan City for drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2011
Resolved 19 February 2011
Resolution: Vessel replaced the damaged piping
Lifesaving › Lifefloat › Serviceable
Issued 14 February 2011
Resolved
A crack was found penetrating into the core material.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2011
Resolved 15 February 2011
Resolution: New lifefloat was installed.
Communications › Radio Communications › EPIRB
Issued 14 February 2011
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2011
Resolved 15 February 2011
Resolution: EPIRB hydro release was renewed and expiration date identified.
Accommodation/Occupational Safety › Ventilation › General
Issued 14 February 2011
Resolved
Ventilation closures for E/R did not fit properly. Crew to adjust each closure and provide fasteners for each stud.
Condition: Improper/Lack of Maintenance
Due 15 February 2011
Resolved 15 February 2011
Resolution: Both E/R ventilation covers were fit tested sat and fasteners installed.
Electrical › Electrical Distribution System (service) › Cable
Issued 14 February 2011
Resolved
An extention cord was found wired into a junction box under P/H console.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 19 February 2011
Resolution: Vessel removed the extension cord
Lifesaving › Lifebuoys › Serviceable
Issued 14 February 2011
Resolved
Port Aft lifering was missing retro, line, and vessel's name. [name withheld] stated lifering will be replaced.
Condition: Improper/Lack of Maintenance
Due 15 February 2011
Resolved 15 February 2011
Resolution: New lifering was placed onboard.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 14 February 2011
Resolved
Vessel has approx 100-150 gals of oil water in E/R bilges. Port Capt was instructed to pump to approved facility prior to departing port.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 February 2011
Resolved 19 February 2011
Resolution: Vessel cleaned bilges
Fire Fighting › Nozzles › Approval
Issued 5 October 2010
Resolved
Found nozzles on E/R and port main deck fire hoses missing.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2010
Resolved 5 October 2010
Resolution: [name withheld] reported item is corrected.
Fire Fighting › Fire Hoses › Condition
Issued 5 October 2010
Resolved
Spanner wrench on aft pilot house fire station missing.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2010
Resolved 5 October 2010
Resolution: [name withheld] reported itme is corrected.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 October 2010
Resolved
Aft port life ring needed marked with vessels name and lined attached.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2010
Resolved 5 October 2010
Resolution: [name withheld] reported item corrected.
Lifesaving › Lifebuoys › Quantity
Issued 5 October 2010
Resolved
Vessel had only five liferings available for inspection. Vessel requires a total of six.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2010
Resolved 5 October 2010
Resolution: [name withheld] reported item has been corrected.
Communications › Radio Communications › EPIRB
Issued 5 October 2010
Resolved
Hydro release on EPIRB was renewed but had no expiration date.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2010
Resolved 5 October 2010
Resolution: [name withheld] reported item has been corrected.
Lifesaving › Lifefloat › Painter
Issued 23 August 2006
Resolved
Painter - Missing
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2006
Resolved 18 September 2006
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 23 August 2006
Resolved
2 e-light located in engine room inop.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2006
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 23 August 2006
Resolved
All PML's had expired dates.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2006
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 23 August 2006
Resolved
Provide full body harness for use with MOB platform.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 August 2006
Resolved
Perform all required drills prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2006
Stability › Watertight Integrity › General
Issued 5 November 2005
Resolved
Make all repairs IWO bow area prior to sailing.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 25 November 2005
Resolution: All repairs completed with satisfactory results.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 5 November 2005
Resolved
Remove, Inspect and Repair stbd shaft, IWO cracked key way, recondition and or renew propellers prior to sailing.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 17 November 2005
Resolution: Renewed shaft and replced propellers.
Lifesaving › Lifefloat › Netting
Issued 13 September 2004
Resolved
Renew webbing on one life float prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 October 2004
Resolved 13 September 2004
Resolution: Replaced float
Construction/Loadline › Structures › Superstructure
Issued 13 September 2004
Resolved
Renew starboard bridge door window prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 October 2004
Resolved 13 September 2004
Resolution: Replaced window.
Engineering › Lubricating Oil Service System
Issued 12 June 2003
Resolved
REPAIR OR RENEW STARBOARD MAIN ENGINE LUBE OIL GAUGE AT OPERATING STATION. LEGACY COMPONENT DESC: Gauge
Action required: 705 - Other - as specified
Due 12 July 2003
Resolved 13 June 2003
Resolution: REPLACED STARBOARD ENGINE LUBE OIL GAUGE AT OPERATING STATION.
Communications › Alarms/Indicators
Issued 12 June 2003
Resolved
PROVIDE SEPARATE VISUAL INDICATORS FOR EACH BILGE ALARM. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2003
Resolved 13 June 2003
Resolution: INSTALLED SEPARATE VISUAL INDICATORS FOR EACH BILGE ALARM.
Engineering › Steering Gear System
Issued 12 June 2003
Resolved
CALIBRATE OR RENEW FORWARD OPERATING STATION RUDDER ANGLE INDICATOR. LEGACY COMPONENT DESC: Rudder Angle Indicator
Action required: 705 - Other - as specified
Due 12 July 2003
Resolved 13 June 2003
Resolution: CALIBRATED FORWARD OPERATING STATION RUDDER ANGLE INDICATOR.
Accommodation/Occupational Safety › Potable Water System
Issued 12 June 2003
Resolved
PROVIDE INSECT SCREENS FOR POTABLE WATER VENTS. LEGACY COMPONENT DESC: Insect Screens
Action required: 705 - Other - as specified
Due 12 July 2003
Resolved 13 June 2003
Resolution: INSTALLED INSECT SCREENING ON POTABLE WATER VENTS.
Lifesaving › Buoyant Apparatus
Issued 12 June 2003
Resolved
ATTACH WEAK LINK FROM VESSEL TO LIFE FLOATS FOR STRAIGHT PULL OPERATION. LEGACY COMPONENT DESC: Weak Link
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2003
Resolved 13 June 2003
Resolution: RE-RUN WEAK-LINK LINE FOR STRIGHT PULL FROM VESSEL TO LIFEFLOATS.
Engineering › Compressed Air System (control)
Issued 12 June 2003
Resolved
RENEW PRESSURE RELIEF VALVE FOR PRESSURE VESSEL. LEGACY COMPONENT DESC: Relief Valve
Action required: 705 - Other - as specified
Due 12 July 2003
Resolved 13 June 2003
Resolution: REPLACED PRESSURE RELIEF VALVE ON PRESSURE VESSELS.
Engineering › Fuel Oil Service System
Issued 12 June 2003
Resolved
RENEW FUEL HOSE ON PORT MAIN ENGINE. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 12 July 2003
Resolved 13 June 2003
Resolution: REPLACED FUEL HOSE ON PORT MAIN ENGINE.
Lifesaving › Buoyant Apparatus
Issued 12 June 2003
Resolved
RE-STENCIL BOTH LIFE FLOATS WITH VESSEL NAME AND HOMEPORT. LEGACY COMPONENT DESC: Life Floats
Action required: 705 - Other - as specified
Due 12 July 2003
Resolved 13 June 2003
Resolution: STENCILED BOTH LIFE FLOATS WITH VESSEL NAME AND HOMEPORT.
Lifesaving › Lifebuoys
Issued 24 September 2002
Resolved
RENEW RETRO-REFLECTIVE TAPE ON TWO LIFE BUOYS. LEGACY COMPONENT DESC: RETRO-REFLECTIVE TAPE
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2002
Resolved 24 September 2002
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 September 2002
Resolved
REPAIR BILGE ALARM.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2002
Resolved 24 September 2002
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 24 September 2002
Resolved
RENEW LUBE OIL FLEXIBLE HOSE ON STARBOARD GENERATOR PRESSURE SWITCH. LEGACY COMPONENT DESC: FLEXIBLE HOSE
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2002
Resolved 25 September 2002
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 September 2002
Resolved
REPAIR ONE LIFE FLOAT LIGHT.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2002
Resolved 24 September 2002
Engineering › Fuel Oil Service System › Piping
Issued 24 September 2002
Resolved
REPAIR FUEL OIL PIPING ON PORT MAIN ENGINE.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2002
Resolved 25 September 2002
Construction/Loadline › Hull › Stringer
Issued 24 September 2002
Resolved
MAKE PERMANENT REPAIRS TO DEEP FRAMS INBOARD OF BOTH MAIN ENGINES.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2002
Resolved 25 September 2002
Electrical › Electrical Distribution System (service) › Switchboard
Issued 24 September 2002
Resolved
REPAIR SWITCH BOARD INTERLOCK.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 October 2002
Resolved 25 September 2002
Construction/Loadline
Issued 18 June 2001
Resolved
PROVIDE PROOF THAT VESSEL WAS CONSTRUCTED TO APPROVED PLANS TO THE OFFICER IN CHARGE MARINE INSPECTION, MORGAN CITY.
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Navigation
Issued 17 June 1998
Resolved
Swing magnetic compass and provide deviation table.
Condition: Unknown
Due 17 June 1998
Resolved 17 June 1998
Deck/Cargo
Issued 25 March 1994
Resolved
PROVIDE ON BOARD VESSEL CARGO TRANSFER PROCEDURE IAW 33 CFR 155.750.
Condition: Unknown
Due 25 March 1994
Resolved 25 March 1994
Navigation
Issued 28 March 1991
Resolved
PROVIDE ONBOARD CURRENT REQUIRED NAVIGATION PUBLICATIONS.
Condition: Unknown
Due 28 March 1991
Resolved 28 March 1991
Engineering
Issued 1 March 1990
Resolved
INSTALL METAL SHIELDS ON RACOR FILTERS ON PORT AND STARBOARD MAIN DIESEL ENGINES AND PORT AND STARBOARD SHIP SERVICE GENERATORS.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Documentation
Issued 1 March 1990
Resolved
PROVIDE ON BOARD CURRENT FCC RADIO STATION LICENSE.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Navigation
Issued 1 March 1990
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF SINGLE SIDE BAND RADIO.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Fire Fighting
Issued 1 March 1990
Resolved
REPLACE/SERVICE FOUR B-II PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Engineering
Issued 1 March 1990
Resolved
RECONNECT AND DEMONSTRATE PROPER OPERATION OF OVERSPEED PROTECTION DEVICES ON PORT AND STARBOARD MAIN DIESEL ENGINES.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Navigation
Issued 19 February 1987
Resolved
REINSTALL AND OPERATE ALL REQUIRED ELECTIONIC EQUIPMENT PRIOR TO VESSEL GETTING UNDERWAY FROM LAYUP STATUS
Condition: Unknown
Due 19 February 1987
Resolved 19 February 1987