USNS SGT. MATEJ KOCAK

Built
1983
Last inspected
18 July 2024
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 July 2024
…with no type recorded6
…past their stated due date2
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7802706
239016
Flag
UNITED STATES
Maury page id
psix-239016

Documentation record

Tonnage as PSIX records it45408 - Convention (Subpart B), Gross Ton
29091 - Regulatory (Subpart C or D), Gross Ton
13622 - Convention (Subpart B), Net Ton
18895 - Regulatory (Subpart C or D), Net Ton
24460 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 39 inspections, each with its date, unit and type; 191 deficiencies with the resolution recorded against each, 3 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 39

18 July 2024 Load Line/Change of Employment · Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7956912
16 February 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7141330
24 August 2020 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7032230
5 August 2020 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7019897
21 July 2020 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7018257
20 November 2019 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6859384
30 September 2019 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6826443
5 August 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6773701
13 June 2019 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6713152
12 June 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6712264
24 May 2019 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6696180
1 May 2019 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6675796
17 April 2019 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6664487
6 April 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6657095
14 March 2019 ACP Periodic Oversight · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6642113
14 March 2019 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6644272
27 February 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6633128
18 December 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6600107
13 December 2018 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6597329
27 November 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6587821
2 November 2018 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6573587
6 October 2018 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6556526
20 September 2018 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6544521
17 August 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6518004
9 August 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6512001
3 July 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6469853
3 July 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6495048
17 May 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6430783
26 April 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6400720
24 April 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6398383
14 December 2017 In-Service Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6326577
6 December 2017 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6319116
21 January 2017 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6293218
10 January 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6080607
28 December 2016 Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6063543
17 December 2016 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6110068
8 December 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6056499
23 September 2016 ACP COI Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6007449
2 February 2016 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 5816074

Deficiency record · 191

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 August 2020 Resolved
The condition of the ship and equipment shall be maintained to conform with the provisions of the present regulations. Vessels Emergency Diesel Generator failed to consistently take load. Make permanent repairs to the generator and prove proper operation to the satisfaction of ABS and to the satisfaction of the attending marine inspector. 74 SOLAS 14 I/11
Action required: 10 - Deficiency Rectified
Due 26 August 2020
Resolved 27 August 2020
Resolution: EDG took and maintained load two consecutive times.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 August 2020 Resolved
Fire detection and fire alarm systems shall be kept in good order to ensure required performance. Vessels fire detection panel could not be proven at time of inspection. Crew was unfamiliar with which smoke detectors were working and which were in ROS. Smoke detector in weld shop was disassembled. No smoke detectors that were tested in the presence of a marine inspector indicated on the fire control panel. Demonstrate proper operation to the satisfaction of ABS and the attending Coast Guard marine inspector. 74 SOLAS 14 II-2/14.2.1.1.2
Action required: 10 - Deficiency Rectified
Due 26 August 2020
Resolved 27 August 2020
Resolution: Tested 5 smoke detectors. Crew was familiar with testing and detectors. All sat.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 24 August 2020 Resolved
he condition of the ship and equipment shall be maintained to conform with the provisions of the present regulations. Vessel could not prove proper operation of water tight door. Prove proper operation of water tight door to satisfaction of attending marine inspector. 74 SOLAS 14 I/11
Action required: 10 - Deficiency Rectified
Due 26 August 2020
Resolved 27 August 2020
Resolution: Watertight door operationally tested all sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 24 August 2020 Resolved
The admin may entrust inspections and surveys to the RO. Vessel does not have certified cargo gear. Obtain certification of cargo gear to the satisfaction of ABS prior to using cargo gear. 74 SOLAS 14 I/6
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 2 September 2020
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 August 2020 Resolved
Fire protection, including fire-resisting divisions, and protection of openings and penetrations shall be kept in good order. Penetrations under main bridge control console and in gyro compass room on bridge were found not to be of proper structural fire protection. Make permanent repairs to the satisfaction of ABS. 74 SOLAS 14 II-2/14.2.1.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 2 September 2020
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 August 2020 Resolved
Fire protection, including fire-resisting divisions, and protection of openings and penetrations shall be kept in good order. Verify location of "class A" fire boundaries and correct fire protection in accordance with the vessel's approved fire plans to the satisfaction of ABS. 74 SOLAS 14 II-2/14.2.1.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 2 September 2020
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 24 August 2020 Resolved
The condition of the ship and equipment shall be maintained to conform with the provisions of the present regulations. 1JV sound powered phone on bridge had no audible on bridge when it was called from the steering gear space. Make permanent repairs to the satisfaction of ABS. 74 SOLAS 14 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 2 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 August 2020 Resolved
The condition of the ship and equipment shall be maintained to conform with the provisions of the present regulations. Reach rod forward of the port boiler is not supported. Make permanent repairs to the satisfaction of ABS. 74 SOLAS 14 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 2 September 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 August 2020 Resolved
The condition of the ship and equipment shall be maintained to conform with the provisions of the present regulations. The engine room port side lower communications booth has disconnected and loose wiring. Make permanent repairs to the satisfaction of ABS. 74 SOLAS 14 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 2 September 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 August 2020 Resolved
The condition of the ship and equipment shall be maintained to conform with the provisions of the present regulations. Numerous dead end wires were found on the STBD side bridge wing, and above and aft of the bridge on vessel's stack. Remove all dead end wires to the satisfaction of ABS. 74 SOLAS 14 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 2 September 2020
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 24 August 2020 Resolved
The condition of the ship and equipment shall be maintained to conform with the provisions of the present regulations. Multiple plumbing, electrical, and general habitability issues were noted throughout "surge" berthing. Correct issues to the satisfaction of ABS prior to using surge berthing.74 SOLAS 14 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 2 September 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 24 August 2020 Resolved
The condition of the ship and equipment shall be maintained to conform with the provisions of the present regulations. Window above and FWD of #3 lifeboat on the house had a cover taped over it. Remove cover, inspect and make permanent repairs if needed to the satisfaction of ABS. 74 SOLAS 14 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 2 September 2020
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 24 August 2020 Resolved
The condition of the ship and equipment shall be maintained to conform with the provisions of the present regulations. Exhaust louver on E3-50-1 did not fully open, make permanent repairs to the satisfaction of ABS. 74 SOLAS 14 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 2 September 2020
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 August 2020 Resolved
The condition of the ship and equipment shall be maintained to conform with the provisions of the present regulations. Firefighting piping serving the STBD helicopter landing pad was heavily corroded just forward of fire team locker. Prove piping is within wastage limits or crop and renew to the satisfaction of ABS. 74 SOLAS 14 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 2 September 2020
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 24 August 2020 Resolved
In all classes of water tight doors indicators shall be fitted at all operating stations from which the doors are not visible, whether the doors are open or closed. Open indicator light on the bridge was not operating. Make permanent repairs to the satisfaction of ABS. 60 SOLAS II/13(f)(v)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2020
Resolved 2 September 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 August 2019 No resolution recorded
After any survey of the ship, no change shall be made in the structural arrangements, machinery, equipment, etc. covered by the survey, without the sanction of the Administration. Vessel Master reported primary low pressure CO2 compressor inoperable. SOLAS 74 I/11
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 24 May 2019 Resolved
Weather tight door #10 has a crack in the flange of upper inboard, inside of the door. Locking pins are unable to be engaged. Make door weather tight prior to departure.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2019
Resolved 14 June 2019
Resolution: Received ABS report that weather tight door has been temp repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 March 2019 Resolved
#4 Davit has wastage at the lower forward deck connection. Provide gauging report with OEM attesting to acceptable limits or repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2019
Resolved 30 May 2019
Resolution: Metal was replaced and 1.1 conducted
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 March 2019 Resolved
Stern skeg has severe wastage on number 4 lifeboat. provide gauging report with OEM attesting to wastage limits or repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2019
Resolved 30 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 March 2019 Resolved
#4 lifeboat hose connection to the shaft log from the packing gland is delaminating and cracking, replace hose to OEM recommendations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2019
Resolved 30 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 March 2019 Resolved
Fiberglass on #4 lifeboat aft hook recess area was delaminating, make repairs to OEM recomendations.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2019
Resolved 30 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 March 2019 Resolved
#4 lifeboat had severe wastage on a through bolt that connects the hook attachment to the skeg. Replace bolt to OEM specifications.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2019
Resolved 30 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 March 2019 Resolved
#4 lifeboat has a fuel leak at the number one cylinder injector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2019
Resolved 18 April 2019
Resolution: Injector was replaced and leak has stopped.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 March 2019 Resolved
#1 and #3 life boats are not in the davits and all life boats have there inventory of required equipment stowed in staterooms. place all appliances in proper ready for sea locations prior to oceans route.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2019
Resolved 13 June 2019
Resolution: LBs #1 & 3 in davits w/required equipment on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 March 2019 Resolved
#3 lifeboat is not in place and #4 lifeboat is not fit for service. Maximum persons onboard is limited to 48.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2019
Resolved 30 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. Engine room main control console controls to include the throttle control module has undergone substantial electrical trouble shooting and is not yet fully reliable. Provide tech report for full repairs. 74 SOLAS (14 Cons.)I/11
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 March 2019
Resolution: Received technician report from ICI attesting to full repair. Uploaded into documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. Bilge pumping arrangement from the port bilge pump is unable to pull/dewater from the aft bilge pocket beneath the reduction gear. Demonstrate proper operation. 74 SOLAS (14 Cons.)I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2019
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 14 March 2019 Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed. Engine room exhaust fan damper on the port side is inoperable. Repair. 60 SOLAS II/47
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 14 March 2019 Resolved
The means for securing and maintaining weathertightness shall ensure tightness can be maintained in any sea condition. Ammo hold #3 hatchway does not properly secure and the gasket is twisted. 66 ICLL I/16(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 14 March 2019 Resolved
The means for securing and maintaining weathertightness shall ensure tightness can be maintained in any sea condition. Ammo hold #2 hatchway has a twisted gasket. 66 ICLL I/16 (4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 14 March 2019 Resolved
The normal equipment of every lifeboat shall consist of a food ration for each person the lifeboat is certified to carry. Lifeboat #2 only has 17 serviceable food rations. Total persons on board limited to 17. 60 SOLAS III/(a)(xii)
Action required: 705 - Other - as specified
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 14 March 2019 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Lifeboat #4 cooling water suction is not functioning properly. Total persons on board limited to 48(pending LB#2 food correction). 74 SOLAS (14) III/20.2
Action required: 705 - Other - as specified
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 14 March 2019 Resolved
The company and the ship shall comply with requirements of ISM. Provide an internal audit of the vessel’s preventative maintenance system. 74 SOLAS (14) IX/3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 18 April 2019
Resolution: Received copy of CG-835 from vessel signed, stamped, and dated by ABS as cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. MOV power panel P51 12’0” Flat Stbd are improperly labeled. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 4 April 2019
Resolution: Received copy of CG-835 from vessel signed, stamped, and dated by ABS as cleared.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. Fuel oil valve MOV for port side P3 fuel tank is missing. Replace. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 31 May 2019
Resolution: Received copy of CG-835 from vessel signed, stamped, and dated by ABS as cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. Engine driven lube oil pump for the ALCO pressure switch is missing electrical nut packing. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. Main circulation valve MOV for suction side is missing electrical packing nut. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. Deck plating by main circulation valve MOV is not supported. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 June 2019
Resolution: Received copy of CG-835 from vessel signed, stamped, and dated by ABS as cleared.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 March 2019 No resolution recorded
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. Main circulation pump suction at the sea chest appears heavily corroded as well as below main condenser scoop. Provide UT report where heavily pitted for these two areas. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 March 2019 Resolved
All inlets and discharges in the shell plating shall be fitted with efficient and accessible arrangements for preventing the accidental admission of water into the ship. During maintenance of main and emergency fire pumps, water was seen coming out in excess even though the isolation valves were closed. Demonstrate valve tightness. 60 SOLAS II/14(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 June 2019
Resolution: Received copy of CG-835 from vessel signed, stamped, and dated by ABS as cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. Remove flammables from the starboard workshop. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. Main condenser overboard discharge MOV open light is out. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. SSDG ALCO jacket water pressure gauge is inoperable. 74 SOLAS (14)I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. EDG 480V Bus ground detector bulb is burnt out. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 March 2019 Resolved
All electrical apparatus shall be so constructed and so installed that danger of injury in ordinary handling shall not exist. Electrical junction box forward of starboard generator found with wires improperly bundled. 60 SOLAS II/27
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. SSTG MOV steam inlet indicator and mechanical indicator is inoperable. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 March 2019 Resolved
All electrical apparatus shall be so constructed and so installed that danger of injury in ordinary handling shall not exist. Overhead light above main fire pump is improperly supported. 60 SOLAS II/27
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. General alarm bell above hot water tank is taped and label is painted. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. Port head tank gauge glass for the steering gear leaks. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. Port and starboard steering hydraulic pumps leak. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. GE SSDG leaks excessively at L/O pre-lube pump and beneath sump. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 4 April 2019
Resolution: Received copy of CG-835 from vessel signed, stamped, and dated by ABS as cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. Port pump discharge (steering gear) gauge is broken. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. In motor room, salt water pump coupling is missing. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. Double bottom tank #5 inboard sounding tube self-closing spring is broken. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 4 April 2019
Resolution: Received copy of CG-835 from vessel signed, stamped, and dated by ABS as cleared.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. JP5 deep tank #2P fill/suction indicator is out. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. JP5 deep tank #2S fill/suction indicator is out. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. DS-2 tank fill valve indicator light is out. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. MOGAS tank fill light is out. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. JP5 wing tank #2s fill/suction light is out. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. Main turbine axial displacement indicator at main console push button is stuck in. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. One smoke and one heat detector in stack are improperly mounted. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 18 April 2019
Resolution: Received copy of CG-835 from vessel signed, stamped, and dated by ABS as cleared.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. MIs observed engineers not properly implementing the lockout/tag out procedures per vessel’s SMS. Conduct internal audit and provide corrective actions. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 18 April 2019
Resolution: Received copy of CG-835 from vessel signed, stamped, and dated by ABS as cleared.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 March 2019 Resolved
Emergency power in cargo ships 5,000GT and upwards shall power every boat station on deck and oversides, in all alleyways, stairways and exits. Escape route from Hold 3A on second deck is not properly illuminated by emergency lighting. 60 SOLAS II/26(a)(ii)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 March 2019 Resolved
Fire detection system alarms shall operate both audible and visible signals at the main stations, cargo systems need not have audible alarms. The smoke detection panel on the bridge has an inoperable light/indicator for the space identified as 58’ Flat FR 57-N. 60 SOLAS II/61(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 14 March 2019 Resolved
The normal equipment of every lifeboat shall consist of one approved cover of a highly visible color capable of protecting the occupants against injury by exposure. All four lifeboat canopies have deteriorated hardware. 60 SOLAS III/11(a)(xxvi)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 18 April 2019
Resolution: Received copy of CG-835 from vessel signed, stamped, and dated by ABS as cleared.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 14 March 2019 No resolution recorded
No change shall be made in the structural arrangements, machinery, equipment and other items covered by a survey after its completion. JV1 and JV3 sound powered phones on the bridge are not ringing when called. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by a survey after its completion. Escape scuttle located main deck starboard side has wasted handle/wheel. Replace handle/wheel. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by a survey after its completion. Escape hatches on the main deck are not properly marked. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 March 2019 Resolved
Launching instructions shall be posted in the vicinity of the survival craft and be easily seen under emergency lighting conditions. Forward liferaft instructions not illuminated by emergency lighting. 74 SOLAS (14) III/8.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 7 June 2019
Resolution: Received copy of CG-835 from vessel signed, stamped, and dated by ABS as cleared.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by a survey after its completion. Bosun store low pressure CO2 bottles are not properly secured for sea. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 14 March 2019 Resolved
Where air pipes to ballast and other tanks extend above the freeboard or superstructure decks, the exposed parts of the pipes shall be of substantial construction. The #1 deep tank gooseneck vent on the starboard side is substantially wasted. Crop and renew wasted steel. 66 ICLL I/20
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by a survey after its completion. Smoke detection panel on the bridge is registering reoccurring error code. Permanently clear error codes and provide servicing report attesting to the proper operation of the smoke detection system and panel. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by a survey after its completion. Stowage locations for lifejackets and immersion suits kept in crew accommodations are not properly labeled. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by a survey after its completion. Drain pipe from the sink in crew accommodation AB 4-8 is missing. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 March 2019 Resolved
Openings in freeboard decks shall be protected by an enclosed superstructure and made weathertight. Dead end cable running through main deck penetration near stairway on the vessels stern is not properly sealed. Remove electrical hazard and properly seal deck penetration. 66 ICLL I/18(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 March 2019 Resolved
Openings in freeboard decks shall be protected by an enclosed superstructure and made weathertight. Dead end cable running through main deck penetration on the vessels stern near outlet is not properly sealed. Remove electrical hazard and properly seal deck penetration. 66 ICLL I/18(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 14 March 2019 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by a survey after its completion. Acetylene and oxygen cylinders on the main deck located at the stern of the vessel are out of compliance with hydrostatic testing dates. Service cylinders in compliance with regulatory requirements or remove from the vessel. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 March 2019 Resolved
Fire doors in main vertical zone bulkheads other than watertight doors shall be of the self-closing type. Bridge stair and galley deck fire doors are not self-closing. 60 SOLAS II/38(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 5 April 2019
Resolution: Cleared by ABS Survey Report # NN3648599
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 14 March 2019 Resolved
Where “A” class divisions are pierced for the passage of electrical cables arrangements shall be made to ensure that the fire resistance is not impaired. One cable penetration into the stairtower at surge crew berthing has dissimilar sealant. Seal cable penetrations with approved installation. 60 SOLAS II/38(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 18 April 2019
Resolution: Received copy of CG-835 from vessel signed, stamped, and dated by ABS as cleared.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 14 March 2019 Resolved
Upon activation, vessel is to provide MMC's for all crew when vessel is fully manned IAW COI to the satisfaction of the attending Marine Inspector. STCW
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 June 2019
Resolution: Marine Inspector reviewed MMCs and verified proper manning per vessel's COI.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 March 2019 Resolved
Vessel does not keep up to date charts and publications while in ROS. Upon activation, provide up to date charts and publications to the satisfaction of the attending Marine Inspector. 33CFR164.33
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 June 2019
Resolution: Marine Inspector verified the presence of adequate and up to date charts and publications.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 14 March 2019 Resolved
Every crew member shall participate in at least one abandon ship drill and one fire drill every month. When a new crew is engaged, these drills shall be held before sailing. Upon activation, vessel is to conduct abandon ship and fire drills to the satisfaction of the attending Marine Inspector. 74 SOLAS (14) III/19.3.2
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 June 2019
Resolution: Marine Inspector witnessed crew conduct satisfactory fire drill.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 14 March 2019 Resolved
Each boat shall be launched and maneuvered in the water by its assigned operating crew at least once every three months. Upon activation, each boat shall be launched and maneuvered in the water by its assigned operating crew. 74 SOLAS (14) III/19.3.3.3
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 June 2019
Resolution: Marine Inspector witnessed the crew lower, release, maneuver in the water, and recover the #1 LB.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 March 2019 Resolved
Missing IMO symbol for parachute flares located near the bridge. Replace.
Action required: 10 - Deficiency Rectified
Resolved 14 March 2019
Resolution: IMO symbol placed on stowage container for bridge parachute flares.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 14 March 2019 Resolved
Lifeboat #2 davit system operated from incorrect control station. Demonstrate proper operation of #2 lifeboat davit system.
Action required: 10 - Deficiency Rectified
Resolved 15 March 2019
Resolution: #2 lifeboat davit system operated successfully from the proper control station after replacement of forward limit switch.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 March 2019 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Main fire pump was observed smoking at the packing during operation. Upon adjustment, the fire pump was leaking excessively. 74 SOLAS (14) II-2/14
Action required: 10 - Deficiency Rectified
Resolved 15 March 2019
Resolution: Corrected prior to completion of inspection.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 March 2019 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Emergency fire pump was observed to be leaking excessively. 74 SOLAS (14) II-2/14
Action required: 10 - Deficiency Rectified
Resolved 15 March 2019
Resolution: Repaired prior to completion of inspection.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 14 March 2019 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Emergency fire pump MOV closed instead of opening when actuated remotely from the E/R main console. 74 SOLAS (14) II-2/14
Action required: 10 - Deficiency Rectified
Resolved 15 March 2019
Resolution: Repaired prior to completion of inspection.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 March 2019 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Main fire pump suction valve was nearly seized and extremely difficult to open/close. 74 SOLAS (14) II-2/14
Action required: 10 - Deficiency Rectified
Resolved 15 March 2019
Resolution: Repaired prior to completion of inspection.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 14 March 2019 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Port side E/R foam station isolation ball valve was seized closed. 74 SOLAS (14) II-2/14
Action required: 10 - Deficiency Rectified
Resolved 15 March 2019
Resolution: Repaired prior to completion of inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 13 December 2018 Resolved
Complete Open Lifeboat Concentration Inspection Campaign on all lifeboats. #1 and #3 have not yet been operated in the water. All inventories completed and only #3 needs a material inspection.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2018
Resolved 30 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 November 2018 Resolved
Vessel's #2 bilge pump is not operating at proper capacity. Vessel is required to have 2 full operational bilge pumps. Repair and show proper operation to the satisfaction of attending ABS surveyor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2018
Resolved 27 February 2019
Resolution: Resolved by ABS Class report #8301856
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 9 August 2018 Resolved
THE EMERGENCY FIRE PUMP WAS OBSERVED TO BE LEAKING FORM THE HOUSING AND ONLY PROVIDING 24 PSI AT THE LOCAL DISCHARGE GAUGE. REPAIR THE EMERGECNY FIRE PUMP AND PROVE ITS PROPER OPERATION. SOLAS 74 II/2 REG 14 2.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2018
Resolution: Recieved documenation attesting to ABS clearing this requirment.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 August 2018 Resolved
THE MAIN SWITCHBOARD 120V EMERGENCY CIRCUIT HAS A GROUND. DETERMINE THE SOURCE OF THE GROUND AND REPAIR THE GROUND. SOLAS 60 II/2 REG 26
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2018
Resolution: Received documentation attesting to ABS clearing this requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 August 2018 Resolved
THE AUXILARY SALT WATER PIPE TO THE MAIN CONDENSOR HAS A LEAK AT A WELD AND HAS A SOFT PATCH. REPAIR THE MAIN CONDENSOR AUXILARY SALT WATER PIPE. SOLAS 60 I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2018
Resolution: Received documentation attesting to ABS clearing this requirement.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 9 August 2018 Resolved
THE #10 CARGO HOLD WATER TIGHT DOOR HAS SEVERAL NON-METALLIC HOSES WHICH ARE ROTTED AND SERVE THE DOORS HYDRAULIC CYLINDERS. REPLACE THE HYDRAULIC HOSES WITH APPROVED HOSES. SOLAS 60 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2019
Resolved 27 February 2019
Resolution: Corrected by ABS Report #8301856
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 August 2018 Resolved
AN ISOLATION VALVE IN THE STERN TUBE OIL SYSTEM IS LEAKING. THE LOCATION OF THE VALVE IS IN THE OVERHEAD OF HTE EMERGECNY FIRE PUMP SPACE. REPAIR OF REPLACE THE VALVE. SOLAS 60 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2019
Resolution: Corrected by ABS Class Report #8301856
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 August 2018 Resolved
THIS IS AN AMENDED CG-835 REQUIREMENT ORIGINALLY ISSUED ON 6 DEC 2017. THE ATTENDING MARINE INSPECTORS OBSERVED A LEAK COMING FROM THE PROPULSION SHAFT SEAL. MONITOR THE SHAFT SEAL FOR OIL LEAKS DURING THE NEXT UNDERWAY PERIOD AND PROVIDE A REPAIR PROPOSAL TO THE SATISFACTION OF THE ATTENDING CGMI AND ABS SURVEYOR. SOLAS 60 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 December 2018
Resolution: ABS recorded that seal is to be renewed during next tailshaft inspection. Condition of Class
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 9 August 2018 Resolved
THIS IS AN AMENDED CG-835 REQUIREMENT ORIGINALLY ISSUED ON 6 DEC 2017. THE #3 AND #4 LIFEBOAT LAUNCHING APPLIANCES ARE CORRODED. DE-SCALE, GAUGE, AND REPAIR IAW THE MANUFACTURER'S INSTRUCTIONS AS NEED TO THE SATISFACTION OF THE ATTENDING CGMI AND ABS SURVEYOR. VESSEL REPRESENTATIVES MUST CONTACT THE LOCAL OCMI WITH A PROPOSAL DETAILING A LIFESAVING APPLICANCE ARRANGMENT THAT PROVIDES AN EQUIVALENT LEVEL OF SAFETY AS THE #3 AND #4 LIFEBOATS PRIOR TO VESSEL MOVEMENTS.
Action required: 705 - Other - as specified
Resolved 27 February 2019
Resolution: Cleared by ABS Report #8301856
Engineering › Steam Turbine (propulsion) › Valve, Throttle
Issued 26 April 2018 Resolved
Electrical throttle controls for the propulsion system is malfunctioning. Propulsion can only be controlled by emergency manual throttle valves. Make repairs and test to the satisfaction of the attending ABS surveyor. Additional manning is required for vessel underway and to be verified by the attending CG inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2018
Resolved 17 August 2018
Resolution: Received documentation from ABS Surveyor [name withheld] attesting to the rectification of the CG-835 requirement.
Engineering › Feedwater/Condensate Water System › Pump
Issued 14 December 2017 Resolved
# 1 FEED PUMP BEARING IS LEAKING OIL. REPAIR THE FEED PUMP PRIOR TO DEPARTURE TO THE SATISFACTION OF ABS AND THE ATTENDING MARINE INSPECTOR. SOLAS 60 I/11
Condition: Improper/Lack of Maintenance
Due 14 January 2018
Resolved 20 December 2017
Resolution: Witnessed the operation of the #1 Feed pump; all sat.
Engineering › Feedwater/Condensate Water System › Valve
Issued 14 December 2017 Resolved
# 1 FEED PUMP SUCTION VALVE HAS AN ACTIVE STEAM LEAK. REPAIR THE VALVE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. SOLAS 60 1/11.
Condition: Improper/Lack of Maintenance
Due 14 January 2018
Resolved 20 December 2017
Resolution: Witnessed the # 1 feed pump suction valve while the steam plant was operational and # 1 feed pump were operational; all sat.
Engineering › Feedwater/Condensate Water System › Pump
Issued 14 December 2017 Resolved
# 2 FEED PUMP THROTTLE VALVE HAS A STEAM LEAK AT THE BOTTOM OF THE ASSEMBLY. REPAIR THE THROTTLE VALVE TO THE SATISFACTION OF ABS AND THE ATTENDING MARINE INSPECTOR. SOLAS 60 I/11
Condition: Improper/Lack of Maintenance
Due 14 March 2018
Resolved 25 April 2018
Engineering › Feedwater/Condensate Water System › Pump
Issued 14 December 2017 Resolved
# 1 CONDENSATE PUMP IS LEAKING AT THE PUMP SHAFT SEAL. REPAIR THE CONDENSATE PUMP TO THE SATISFACTION OF ABS AND THE ATTENDING MARINE INSPECTOR. SOLAS 60 I/11
Condition: Improper/Lack of Maintenance
Due 14 January 2018
Resolved 20 December 2017
Resolution: Witnessed the operation of the # 1 condensate pump; all sat.
Engineering › Feedwater/Condensate Water System › Pump
Issued 14 December 2017 Resolved
HOT WATER CIRC PUMP IS LEAKING AT THE PUMP SHAFT SEAL. REPAIR THE HOT WATER CIRC PUMP TO THE SATISFACTION OF ABS AND THE ATTENDING MARINE INSPECTOR. SOLAS 60 I/11
Condition: Improper/Lack of Maintenance
Due 14 March 2018
Resolved 25 April 2018
Engineering › Feedwater/Condensate Water System › Valve
Issued 14 December 2017 Resolved
THE MAIN CONDENSOR RECIRC REGULATING VALVE HAS A SOFT PATCH ON THE VALVE BODY. REPLACE OR REPAIR THE MAIN CONDENSOR REGULATING VALVE TO THE SATISFACTION OF ABS AND THE ATTENDING MARINE INPSECTOR. SOLAS 60 I/11.
Condition: Improper/Lack of Maintenance
Due 14 March 2018
Resolved 17 May 2018
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 14 December 2017 Resolved
NUMEROUS LIGHTS WERE OBSERVED TO BE NOT FUNCTIONAL ON THE ENGINE ROOM MAIN CONSOLE. REPAIR CONSOLE LIGHTS AND DEMONSTRATE THE PROPER OPERATION OF THE CONSOLE TO THE SATISFACTION OF ABS AND THE ATTENDING MARINE INSPECTOR. SOLAS 60 I/11
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 March 2018
Resolved 1 March 2019
Resolution: Received ABS report NN3465902 clearing def.
Engineering › Steam System (main) › Valve
Issued 14 December 2017 Resolved
40TC DRAIN REGULATING VALVE HAS A STEAM LEAK. REPAIR THE 40TC STEAM DRAIN REGULATING VALVE TO THE SATISFACTION OF ABS AND THE ATTENDING MARINE INSPECTOR. SOLAS 60 I/11.
Condition: Improper/Lack of Maintenance
Due 14 March 2018
Resolved 18 December 2018
Electrical › Lighting (service) › Lighting Fixture
Issued 6 December 2017 Resolved
Cargo deck, port side, three deck lights hanging by wires; tank #3 fwd light, tank #4 fwd light, tank #4 aft light. Repair as original to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 16 February 2018
Resolution: Inspected deck lighting repairs; all sat, cleared CG-835.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 6 December 2017 Resolved
Fantail, superstructure ladders, two ladder rungs wasted. Renew rungs to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 30 May 2018
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 6 December 2017 Resolved
Focsle, port ladder, second rung wasted. Renew rung to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 30 May 2018
Lifesaving › Immersion Suits › General
Issued 6 December 2017 Resolved
Focsle, wood immersion suit storage box is deteriorated beyond repair. Provide alternative means to stow immersion suits to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 20 December 2017
Resolution: Verifed the installation of a new immerision suit stowage box on the focsle; all sat.
Deck/Cargo › Holds/Tanks › Watertight Door
Issued 6 December 2017 Resolved
Cargo deck, port side, watertight door to forecastle does not operate as intended. Maintain and adjust dogs and demonstrate door operation to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 12 March 2018
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 6 December 2017 Resolved
Port anchor chain bitter end access plate is missing eight bolts. Install bolts to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 14 December 2017
Resolution: Verfied all hardware was installed on the port anchor chain bitter end access plate; all sat.
Communications › Internal Communications System › Sound-powered Telephone
Issued 6 December 2017 Resolved
Pilot ladder telephone bell housing is hanging by electrical cable. Permanently install as original to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 16 February 2018
Resolution: Inspected installation of pilot ladder telephone bell housing; all sat, cleared CG-835.
Lifesaving › Liferaft Equipment › Instructions (immediate action)
Issued 6 December 2017 Resolved
All liferaft launching instructions are illegible. Post legible liferaft instructions specific to the liferaft and vessel’s configuration to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Due 8 January 2018
Resolved 14 December 2017
Resolution: Verfied legible liferaft launching instruction were installed; all sat.
Lifesaving › Launching Appliances › Davit
Issued 6 December 2017 Resolved
#1 Lifeboat embarkation deck, single point davit power switch broken. Repair as original to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 16 February 2018
Resolution: Inspected installation of single point davit power switch; all sat, cleared CG-835.
Construction/Loadline › Structures › Deck Plating
Issued 6 December 2017 Resolved
#1 Lifeboat embarkation deck, numerous wire penetrations are not weather tight, have dead ends, or are penetrating window bolts. Properly install wires to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 12 March 2018
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 December 2017 Resolved
Cargo deck, starboard side, just forward of the superstructure missing 3 rails between stations. Repair as original to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 14 December 2017
Resolution: Verifed handrails were installed; all sat
Lifesaving › Lifeboat › Lamp (outside)
Issued 6 December 2017 Resolved
Port and starboard lifeboat launching lights extinguished (04). Repair or replace lights to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 16 February 2018
Resolution: Witnessed 04 lifeboat launching lights burning brightly; all sat, cleared CG-835.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 6 December 2017 Resolved
Upper low pressure CO2 tank gauge calibration has expired. Gauge is displaying 97%. Manufacture instructions recommend maintaining tank level at 98%. Calibrate gauge, determine accurate tank level, and adjust tank level IAW the manufacturer’s instructions as needed to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 14 August 2018
Resolution: Verifed that the upper LPCO2 tank level gauge was calibrated and reading 99% full; all sat.
Deck/Cargo › Holds/Tanks › Weathertight Door
Issued 6 December 2017 Resolved
Door #10 is missing a bottom hydraulic pin. Install hydraulic pin IAW the manufacturer’s instructions to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 9 August 2018
Resolution: Verified all hydraulic pin were installed for cargo door number #10. Witnessed the operation of cargo door #10; all sat.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 6 December 2017 Resolved
Bridge smoke detection panel is displaying an error: “Error: Stores Flat Fwd”. Troubleshoot and rectify error IAW the manufacturer’s instructions to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 12 March 2018
Engineering › Steering Gear System › Power Unit
Issued 6 December 2017 Resolved
Port steering pump power failure alarm cannot be silenced in hand steering mode and is only displaying a visual alarm in NFU mode. Rectify alarm issues and demonstrate proper operation of the entire steering system to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2018
Resolution: Witnessed port steering pump power failure alarm testing; all sat.
Accommodation/Occupational Safety › Ventilation › General
Issued 6 December 2017 Resolved
Eleven fire dampers and closures inoperable due to lack of maintenance, broken hinges, wasted gasket channels, or dry rotted gaskets. Repair all fire dampers and closures to the satisfaction of attending CGMI; a.Forepeak centerline fire damper inoperable due to lack of maintenance. b.Engine room port and starboard supply will not close and are missing screens. c.Focsle port and starboard fire damper hinges wasted – renew hinges. d.Focsle centerline fire damper gasket channel wasted – renew, repair, or replace to the satisfaction of attending CGMI and ABS Surveyor. e.Cargo deck, port side fire damper adjacent to tank #3 – renew gasket. f.4A Hold, 2nd deck, the two aft most fire dampers inoperable due to lack of maintenance. g.S3-49-2 fire damper does not close, cover and hardware removed – reinstall and demonstrate operation. h.E2-61-1 Exhaust – closure lying on deck – properly install closure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 March 2018
Resolved 16 February 2018
Resolution: Witnessed operation of all repaired fire dampers; all sat, cleared CG-835.
Construction/Loadline › Structures › Door
Issued 6 December 2017 Resolved
The Class 3 watertight door would not close using the local or remote manual controls. Found the remote indicator stuck in the closed position. Prove proper operation of the Class 3 watertight door using both manual controls. Prove proper operation of remote indicator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2018
Lifesaving › Lifeboat › Propulsion Engine
Issued 6 December 2017 Resolved
#2 lifeboat engine’s lube oil cooler repaired with epoxy. Make permanent repair IAW the manufacturer’s instructions to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 March 2018
Resolved 16 February 2018
Resolution: Witnessed operational test of #2 Lifeboat's engine and inspected installation of new lube oil cooler; all sat, cleared CG-835.
Operations/Management › Drills/Instruction › Fire
Issued 6 December 2017 Resolved
Vessel was not fully crewed during inspection. Demonstrate crew’s proficiency in firefighting, abandon ship drill, vessel control systems, and engineering upon activation to the satisfaction of CGMI.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2018
Resolution: Witnessed satisfactory fire and abadon ship drill; all sat.
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 6 December 2017 Resolved
Provide crew’s licenses and documents, updated charts, and publications upon activation to the satisfaction of CGMI upon activation.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2018
Resolution: Verified Officer MMC's, vessel documents, and updated charts; all sat.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 6 December 2017 Resolved
Found cooling water piping to the starboard steering gear missing mounting hardware or brackets and/or mounted with rope. Properly mount piping using appropriate metallic hardware to the satisfaction of attending CGMI and ABS Surveyor.
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 19 January 2018
Resolution: Verified installation of new pipe hangers for the starboard steering gear cooling water piping; all sat.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 December 2017 Resolved
Oily Water Separator (OWS) automatic three-way valve is not properly shifting from overboard to re-circ. Manufacture recommended testing solution for the Oil Content Meter (OCM) was not onboard. Prove proper operation of the OWS automatic three-way valve. Provide manufacture recommended testing solution OCM. To the satisfaction of attending CGMI and ABS Surveyor.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 20 December 2017
Resolution: Witnessed the operation of calibration of the ows; all sat.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 December 2017 Resolved
Found a soft patch on the overboard piping for the OWS. Renew pipe to original to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 20 December 2017
Resolution: Verifed that ows ovbd pipe with a soft patch had been replaced; all sat.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 6 December 2017 Resolved
Found a coffee can mounted under the vessels shaft seal used to catch oil leaking from the seal. The can is overflowing with oil and draining into the shaft alley bilge. Properly dispose of oil collected in the can and the shaft alley bilge. Monitor shaft seal for oil leaks during next underway period and provide a repair proposal to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 August 2018
Resolution: Cleared the original CG-835 to ammend and reissue the requirement.
Construction/Loadline › Structures › Door
Issued 6 December 2017 Resolved
Port side hull access door aft of frame 47 has a hydraulic leak. Repair hydraulic leak and clean hydraulic oil out of door frame to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 9 August 2018
Resolution: Witnessed the operation of the port side hull access door; all sat.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 6 December 2017 Resolved
Provide Owners Annual Preventative Maintenance Report and procedures for conducting condition monitoring measures for required equipment to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 12 March 2018
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 6 December 2017 Resolved
Lighting in the emergency escape trunk in the emergency fire pump room is inoperable. Prove proper operation of lighting. 2nd Deck, stbd side, aft of frame 42, emergency escape trunk has no emergency lighting. Install emergency lighting so that the means of escape is clearly visible. To the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 25 April 2018
Lifesaving › Lifeboat › Propulsion Engine
Issued 6 December 2017 Resolved
#4 Lifeboat engine has a dry rotted cool water hose and the turbo filter has fallen into the bilge. Repair IAW the manufacturer’s instructions to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 19 January 2018
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Control Valves
Issued 6 December 2017 Resolved
The AFF tank port side aft lower level engineroom is missing its vent, the sight glass valve is not operable, and the level of agent can’t be determined using the sight glass. Install an approved vent, prove proper operation of sight glass valve and prove the level of agent using the sight glass. To the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 19 January 2018
Resolution: Verified installation of AFF tank vent and sight glass level of AFF in the tank; all sat.
Lifesaving › Launching Appliances › Davit
Issued 6 December 2017 Resolved
#3 Lifeboat launching appliance aft-most sheave bracket is severely corroded. De-scale, gauge, and repair IAW the manufacturer’s instructions as needed to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 9 August 2018
Resolution: Cleared the CG-835 to ammend the 835 to include the #4 lifeboat davit. A new CG-835 requirement will be reissued.
Lifesaving › Lifeboat › Propulsion Engine
Issued 6 December 2017 Resolved
#1 Lifeboat engine hydraulic starter fitting is leaking. Repair fitting IAW the manufacturer’s instructions to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 16 February 2018
Resolution: Witnessed operational test of #1 lifeboat's engine and inspected installation of new hydraulic starter piping; all sat, cleared CG-835.
Electrical › Lighting (service) › Outlet Box
Issued 6 December 2017 Resolved
Port side aft lower level engine room work bench has an overhead mounted lighting fixture installed that’s plugged into an electrical outlet. Permanently wire the light to a lighting panel or remove lighting fixture to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 19 January 2018
Resolution: Verified temporarily installed light over engine room workbench was removed; all sat.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 6 December 2017 Resolved
Found an opening in the lower machinery port power panel 7. Install breaker filler plate to the satisfaction of attending CGMI and ABS Surveyor.
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 19 January 2018
Resolution: Verified breaker filler plate is installed; all sat.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 6 December 2017 Resolved
Couldn’t determine if the main switchboard mats were dielectric. Provide documentation that installed mats are dielectric or replace with dielectric matting suitable for high voltage application to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 19 January 2018
Resolution: Verified installation of new matting at the main switchboard; all sat.
Fire Fighting › Fire Main › Material
Issued 6 December 2017 Resolved
#1 Lifeboat embarkation deck, fire station #11 fire main bracket is broken. Repair bracket to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 25 April 2018
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 6 December 2017 Resolved
Found excessive exhaust leaks on the port side SSDG. There’s a portable fan temporarily mounted and providing cooling to the engine. The general emergency light is covered with exhaust soot. Troubleshoot, find, and repair exhaust leaks. Remove portable fan, clean and prove operation of general emergency light. To the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 12 March 2018
Engineering › Fuel Oil Service System › Piping
Issued 6 December 2017 Resolved
Various piping systems in the engineroom are missing support brackets and associated hardware. Repair/replace with appropriate metallic hardware to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 25 April 2018
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 6 December 2017 Resolved
Found evidence of exhaust leaks on the starboard side SSDG. Troubleshoot, find, and repair exhaust leaks. Or provide documentation of repairs and clean all soot covered surfaces. To the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 12 March 2018
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 6 December 2017 Resolved
Starboard side engine room workshop is missing insulation overhead and on the bulkhead. Research and determine if Structural Fire Protection is required in those areas. If required install approved Structural Fire Protection insulation to the satisfaction of attending CGMI and ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 25 April 2018
Engineering › Sea-water System (primary cooling) › Valve
Issued 28 March 2017 Resolved
36" sea water suction valve to the main circ pump inoperative due to froctured ring gear. renew vavle actuator and prove proper operation prior to sailing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2017
Resolution: Actuator renewed.
Engineering › Sea-water System (primary cooling) › Valve
Issued 28 March 2017 Resolved
Crew unable to isolate main condenser from the sea indicating malfunction of one or more of the three 36" sea valves. Prove ability to isolate condenser for emergency repairs if needed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 April 2017
Resolution: Received a report from Port Engineer that the condenser had been sucessfully isolated from the sea. photos of the back side of the scoop and injection pump valves in the closed position and of crew inside the water boxes.OCMI approved def cleared by photo
Engineering › Steam System (main) › Piping
Issued 28 March 2017 Resolved
Warm up bypass on stbd boiler main steam stop wasted through where attached to the valve body and leaking steam. Make proper repairs to satisfaction of ABS/USCG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2017
Resolution: Repairs completed to the satisfaction of attending ABS surveor.
Engineering › Steam System (main) › Piping
Issued 28 March 2017 Resolved
Gasketed flange between main steam stop and bulkhead stop (stbd boiler) leaking. replace gasket and make mainsteam line tight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2017
Resolution: Repairs completed to the satisfaction of attending ABS surveor.
Lifesaving › Lifeboat › Hull
Issued 21 January 2017 Resolved
VSL needs to service its two smaller lifeboats. VSL can still sail utilizing two larger lifeboats located on port and stbd side, each rated for 135 persons. VSL may sail with a reduced ammount of total persons onboard, not to exceed 135 persons.
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 30 November 2017
Resolution: Received report of survey from ABS for condition of lifeboats. 835 has been cleared, and vsl may sail with maximum PAX ammount as alloted on COI.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 January 2017 Resolved
Bilge alarms in ammo holds 1 & 3 are not functioning. make additional rounds as agreed to in Crowley letter dated 07JAN2017 untill repaired. ABS 7-6-2 1.1.6
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 11 April 2017
Resolution: Corrected.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 7 January 2017 Resolved
Engineer's Assistance Needed Alarm system not functional. Repair. ABS 4-9-3 9.5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 11 April 2017
Resolution: Corrected.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 January 2017 Resolved
Sea-water service crossover piping to the main condenser wasted through and sealed with a soft patch. Properly repair piping system. 74SOLAS(14) CH 1REG 11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 23 March 2017
Resolution: Piping replaced.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 January 2017 Resolved
Gantry crain catwalk wasted through. Repair prior to use. 74SOLAS(14) CH 1REG 11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 23 March 2017
Resolution: Catwalk repaired.
Engineering › Feedwater/Condensate Water System › Scoop
Issued 7 January 2017 Resolved
Check valve on Scoop system is pinned open with chain fall. Unable to test scoop valve in thins condition. Repair check valve and prove proper automatic function of scoop sea-water injection system. 7-1-1 7.1.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 11 April 2017
Resolution: Corrected.
Electrical › Electric Generation Source (service) › Generator
Issued 7 January 2017 Resolved
Complete testing of various alarms and limits (low lube oil, overspeed, high temp, ect.) for all three generators. to the satisfaction of the attending classification surveyor. ABS 7-1-1 7.1.3
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 11 April 2017
Resolution: Corrected
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 5 January 2017 Resolved
Sprinkler valves for the container holds do not function remotely and 2 are missing handles. Repair/op test for ABS/USCG. Update: Compliance date changed to 07FEB2017 vessel prohibited from carrying combustables in cargo holds until repaired. ABS 4-7-2 7.3.1 (c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 11 April 2017
Resolution: Item corrected.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 5 January 2017 Resolved
Sample points 27-32 on gas detection system have flow failure alarm. Repair to ABS/USCG satisfaction. Update: Compliance period changed to 07FEB2017 with extra rounds of the effected spaces required until repaired. 74SOLAS(14) CH 1REG 11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 11 April 2017
Resolution: Converted to Class Outstanding Recommendation IAW ACP guidance.
Engineering › Steam Boiler (propulsion) › Pump
Issued 3 January 2017 Resolved
Standby condensate pump is not operational. 74SOLAS(14) I/11 *PRIOR TO DEPARTURE* ABS 4-6-6 5.9.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2017
Resolution: Nonmetalic expansion joint delaminated and clogged inlet to pump. Clog removed, joint replaced, pump tested sat.
Construction/Loadline › Structures › Door
Issued 3 January 2017 Resolved
Port side bunkering station door did not close. 74SOLAS(14) I/11 *PRIOR TO DEPARTURE* ILLC(66) REG 21
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2017
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 3 January 2017 Resolved
Sprinkler pump motor operated suction valve (MOV) is not wired for remote operation. 74SOLAS(14) I/11 *PRIOR TO DEPARTURE* ABS 4-7-2 7.3.1(c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2017
Resolution: Sprinkler pump suction valve remote control restored.
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 January 2017 Resolved
GE generator had raw water leak. 74SOLAS(14) I/11 *PRIOR TO DEPARTURE*
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2017
Resolution: Piping section replaced.
Engineering › Fuel Oil Service System › Pump
Issued 3 January 2017 Resolved
Fuel oil standby pump will not start from engine room console (engine room is approved for minimal manning on COI). 74SOLAS(14) I/11 PRIOR TO DEPARTURE ABS 4-6-6 7.1.3 & ABS 4-6-6 7.3.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2017
Resolution: Pump function from the consol restored.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 30 December 2016 Resolved
Bridge steering alarm panel and audible alarm did not function/sound. 74SOLAS(14) I/11 *PRIOR TO DEPARTURE*ABS 4-3-4 15
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2017
Resolution: Item corrected.
Engineering › Fuel Oil Service System › Hose
Issued 30 December 2016 Resolved
Emergency diesel generator fuel and lube oil hoses and ALCO generator fuel supply/return flex loops are worn beyond repair. 74SOLAS(14) I/11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2017
Resolved 11 April 2017
Resolution: Hoses replaced but still require fire sleeve. item converted to class outstanding recommendation IAW ACP guidance.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 30 December 2016 Resolved
GE generator has exhaust leak. 74SOLAS(14) I/11 & ABS 7-6-2 1.1.1 (a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2017
Resolved 11 April 2017
Resolution: Item converted to Class Outstanding Recommandation IAW ACP Guidance. Item to be corrected prior to carrying cargo.
Engineering › Fuel Oil Service System › Valve, Control
Issued 29 December 2016 Resolved
Fuel oil regulators on both boilers not functioning in automatid mode and leaking. 46 CFR 91.25-45 *prior to departure*. Update: leakage reduced, auto function restored, compliance period changed to 7FEB2017 to renew seals. ABS 4-6-6/ 7.13
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 11 April 2017
Resolution: Regulators replaced.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 29 December 2016 Resolved
Fuel leaks found in way of fuel oil skid: fuel oil meter and fuel oil strainers. 46 CFR 9.24-45 *PRIOR TO DEPARTURE* Update: leakage reduced, compliance period changed from prior to sailing to 07FEB2017. ABS 4-6-6/ 7.3.3 & ABS 4-6-6/7.1.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 11 April 2017
Resolution: F/O skid continues to have various components weeping fuel, however, significant accumulations are no longer evident. Some additional maintenance is needed therefore the item will remain open as an outstanding recommendation.
Engineering › Steam Boiler (propulsion) › Valve, Vent
Issued 29 December 2016 Resolved
Port and starboard boiler control de-superheater drain valves (both) are closed, but still allow steam to pass by. 74SOLAS(14) I/2 *PRIOR TO DEPARTURE* ABS 7-6-2 1.1.1 (a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2017
Engineering › Steam Boiler (propulsion) › Water Level Indicator
Issued 29 December 2016 Resolved
Lower sight glass on port and starboard boilers not back-lit, all gauge glasses are unreadable, water level is not visible in glass. 46 CFR 52.01-10 *PRIOR TO DEPARTURE* ABS 4-4-1 11.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 January 2017
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 29 December 2016 Resolved
Consolidated local throttle control back-up PLC has failed. 74SOLAS(14) I/2 *PRIOR TO DEPARTURE* NVIC 1-69
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 January 2017
Engineering › Steam Boiler (propulsion) › Pump
Issued 29 December 2016 Resolved
Remote feed pump controls not functional/#1 Feed pump will not start. 74SOLAS(14) I/2 *PRIOR TO DEPARTURE* Update: Crew denibstrated ability to cut in all three pumps in manual. Compliance period for remote controls modified to 07FEB2017. NVIC 1-69 ABS 4-9-3 7(iii)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 1 May 2017
Resolution: All three main feed pumps tested successfully.
Engineering › Steam Boiler (propulsion) › Valve, Drain
Issued 29 December 2016 Resolved
Steam leak on the atomizing steam valve adjacent to fuel regulator on #1 Boiler. 74SOLAS(14)I/2 *PRIOR TO DEPARTURE* ABS 7-6-3 1.1.1 (a)
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 7 January 2017
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 29 December 2016 Resolved
Fuel oil transfer pump is leaking fuel. 74SOLAS(14) I/2 -corrected on the spot- ABS 7-6-2 1.1.1 (a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 11 April 2017
Resolution: Original ettempt to tighten packing failed. packing replaced and leakage reduced to a minor weep.
Construction/Loadline › Hull › Hull Plating
Issued 29 December 2016 Resolved
Cathodic protection system not functional. 74SOLAS(14) I/2 *PRIOR TO DEPARTURE*
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 January 2017
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 29 December 2016 Resolved
#1 distiller sea chest MOV (motor operated valve – lower engine room, starboard) not connected. 74SOLAS(14) I/2 *PRIOR TO DEPARTURE* ABS 7-6-2 1.1.1(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2017
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 29 December 2016 Resolved
Severe exhaust leaks on ALCO generator (#1 SSDG). 74SOLAS(14) I/2 *PRIOR TO DEPARTURE*
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 January 2017
Engineering › Feedwater/Condensate Water System › Pump
Issued 29 December 2016 Resolved
#1 main turbo feed pump steam inlet packing gland leaking excessively, pump could not be started manually or automatically. 74SOLAS(14)I/2 *PRIOR TO DEPARTURE* ABS 7-1-1 7.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2017
Resolution: Packing replaced/adjusted.
Operations/Management › Drills/Instruction › Not Conducted
Issued 29 December 2016 Resolved
Complete Periodic Safety Test Procedures. 74SOLAS(14)I/2 *PRIOR TO DEPARTURE* ABS 7-1-1 7.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2017
Resolution: Procedures completed to the extent possible in port.
Engineering › Fuel Oil Service System › Flange
Issued 29 December 2016 Resolved
Fuel oil leaks on GE (#2 SSDG) – inboard side, forward. 74SOLAS(14)I/2 *PRIOR TO DEPARTURE* Update: leakage reduced to very alight weep, compliance period changed to 07FEB2017. ABS 7-6-2 1.1.1(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 11 April 2017
Resolution: leaks repaired.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 29 December 2016 Resolved
Replace 2 missing 10 lb dry chem fire extinguishers in engine room. 60SOLAS CH 2REG66
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 7 January 2017
Resolution: item replaced
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 29 December 2016 Resolved
5 fuel oil leak detection fettings on ALCO generator are loose and wearing into the nut below to varying degrees. Repair to ABS or USCG. ABS 4-6-5 3.3.7(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 February 2017
Resolved 23 March 2017
Resolution: System repaired.
Engineering › Steam System (auxiliary) › Piping
Issued 28 December 2016 Resolved
Flanged connection in steam line from STBD Boiler to SSTG downstream of generator steam stop failed. Renew and repair to original code/rule of construction. If this section of system cannot be isolated so that both boilers can be cut in these repairs must be completed prior to departure of port. If isolation can be accomplished compliance date is 2/19/2017.Repairs to ABS Surveyor satisfaction.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2017
Resolved 23 March 2017
Resolution: Repaired.
Electrical › Electrical Distribution System (service) › Cable
Issued 28 December 2016 Resolved
Electrical cable damaged by steam leak to be identified and systems vital to the safe operation of the vessel repaired/restored prior to departure. Non-vital systems repair by 2/19/2017. Repairs to the satisfaction of attending ABS Surveyor. 74SOLAS(14)Ch.I Reg. 11
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 February 2017
Resolved 23 March 2017
Resolution: Cable renewed.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 28 December 2016 Resolved
Drip shield over switchboard has opening which allowed water to enter breaker panel causing damage. Repair/restore drip shield to original condition prior to departure. Repairs to the satisfaction of attending ABS Surveyor. 74SOLAS(14)Ch. I Reg. 11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2017
Resolved 23 March 2017
Resolution: Dripshield repaired.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 28 December 2016 Resolved
Breaker panel damaged by water intrusion. Restore vital systems prior to departure and on-vital systems by 2/19/2017.Repairs to the satisfaction of attending ABS Surveyor. 74SOLAS(14)Ch. I Reg. 11
Condition: Damaged By Earlier Event
Due 19 February 2017
Resolved 23 March 2017
Resolution: Repaired/renewed.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 28 September 2016 Resolved
Vessel was not fully crewed during inspection. Demonstrate crew's proficiency in firefighting, abandon ship drill, vessel control systems, and engineering upon activation to the satisfaction of a Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 12 December 2016
Resolved 12 December 2016
Resolution: Vessel was examined with fully crew during activation. Fire fighting and abandon ship drills were conducted,vessel control and engineering systems were examined for crew competency, all sat.
Navigation › Piloting/Steering › Marine Charts
Issued 28 September 2016 Resolved
Provide crew's licenses and documents, updated charts, and publications upon activation to the satisfaction of a Coast Guard Marine Inspector upon activation.
Action required: 705 - Other - as specified
Due 12 December 2016
Resolved 12 December 2016
Resolution: Examined all crew licenses and documents, updated charts and publications during activation, all sat.

Recorded names · 1

SGT. MATEJ KOCAK (2001–2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.