Records from 1985 to 2024. Most recent: inspection, 30 September 2024.
Inspection history · 194
30 September 2024
Load Line/Change of Employment
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8011581
16 February 2021
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7141193
17 August 2020
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7035368
22 June 2020
ACP COI Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6983503
1 October 2019
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6826146
30 September 2019
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6826448
28 March 2019
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6689779
21 March 2019
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6650293
18 March 2019
Periodic Inspection · ACP COI Oversight · ACP Handover Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6645387
28 February 2019
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6634643
22 February 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6630559
22 February 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6630578
11 February 2019
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6623985
1 February 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6619526
29 November 2018
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6588942
13 November 2018
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6579738
6 November 2018
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6575789
5 November 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6690459
2 November 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6573127
1 November 2018
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6572823
15 October 2018
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6561420
15 October 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6561615
13 October 2018
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6560637
12 October 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6559986
11 October 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6559224
26 September 2018
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6549726
18 September 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6543425
17 September 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6546076
13 September 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6539334
19 July 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6484501
22 June 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6453722
13 June 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6443128
7 June 2018
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6436573
6 June 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6590049
4 June 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6435152
17 May 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6422238
4 May 2018
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6405777
4 May 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6547041
24 April 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6398363
24 April 2018
ACP Periodic Oversight · Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6400929
24 April 2018
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6407953
23 April 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6397302
14 April 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6400439
13 April 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6391191
5 April 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6408318
5 April 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6408848
5 April 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6408947
23 February 2018
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6360292
30 October 2017
ACP Additional Oversight – Risk Assessment
Administrative · Commandant (CG-5P-TI) · Activity 6299436
29 August 2017
ACP Additional Oversight – Risk Assessment · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6261502
10 August 2017
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6236652
24 May 2017
ACP COI Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6150069
23 January 2017
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6075473
5 October 2016
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6017013
12 May 2016
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5910839
1 April 2016
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5844903
9 March 2016
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 5922149
27 February 2016
Deficiency Check · Administrative Inspection · ACP Periodic Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5823646
26 February 2016
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 5823648
25 February 2016
ACP Periodic Oversight · Administrative Inspection · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5821563
27 January 2016
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 5804940
27 January 2016
ACP Periodic Oversight · Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 5805835
24 November 2015
Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5769085
17 November 2015
ACP Annual Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5756981
14 August 2014
ACP COI Oversight · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4954398
31 May 2014
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4878182
18 March 2014
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4818830
18 July 2012
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4383199
9 July 2012
Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4372944
20 December 2011
Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4214273
28 February 2011
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3953756
19 November 2010
ACP Annual Oversight
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3898031
4 September 2010
Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 3843754
27 December 2009
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3720132
29 July 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3549697
6 May 2009
Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3469257
8 December 2008
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3377930
2 October 2008
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3337690
22 August 2008
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 3443326
23 June 2008
ACP Annual Oversight · MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3247001
3 March 2008
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3157183
15 January 2008
MTSA/ISPS Verification · MARPOL Annex I Examination · ISM Oversight
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3131092
7 January 2008
Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3131075
3 January 2008
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3124444
5 June 2007
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2952396
10 August 2006
Annual Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2751456
9 June 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2677718
18 February 2006
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2601934
21 July 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2434105
2 July 2005
ACP Annual Oversight
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2424876
3 November 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2233883
7 June 2004
MTSA/ISPS Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2090620
13 May 2004
ACP COI Oversight · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2065379
23 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1975580
20 November 2003
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1990080
15 October 2003
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1929193
5 September 2003
In-Service Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1897881
15 August 2003
In-Service Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1879405
24 July 2003
Administrative Inspection
Administrative · Activities Europe · Activity 1867088
1 June 2003
Periodic Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1830562
26 February 2003
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1749720
26 February 2003
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1750129
11 February 2003
Type not recorded
No type recorded · Activities Europe · Activity 1759955
14 August 2002
Type not recorded
No type recorded · Activities Europe · Activity 1663694
14 August 2002
Type not recorded
No type recorded · Activities Europe · Activity 1695853
29 January 2002
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1482282
31 March 2001
COI Inspection
Physical examination · Activities Europe · Activity 1447063
2 May 2000
Type not recorded
No type recorded · Activities Europe · Activity 60280
25 April 2000
Type not recorded
No type recorded · Activities Europe · Activity 281617
25 April 2000
Re-Inspection
Physical examination · Activities Europe · Activity 1369814
28 October 1999
Administrative
Administrative · Activities Europe · Activity 1128771
1 September 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1115715
23 July 1999
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 496214
22 July 1999
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1103930
29 April 1999
Type not recorded
No type recorded · Activities Europe · Activity 275524
28 April 1999
COI Inspection
Physical examination · Activities Europe · Activity 1365212
21 January 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1122338
8 January 1999
Type not recorded
No type recorded · Activities Europe · Activity 709124
22 July 1998
Type not recorded
No type recorded · Activities Europe · Activity 809649
9 July 1998
Type not recorded
No type recorded · Activities Europe · Activity 709125
26 May 1998
Deficiency Check
Physical examination · Activities Europe · Activity 791582
16 April 1998
Re-Inspection
Physical examination · Activities Europe · Activity 789814
27 January 1998
Type not recorded
No type recorded · Activities Europe · Activity 704
5 November 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 158761
16 May 1997
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 403841
16 May 1997
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1096285
15 May 1997
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 403846
28 April 1997
Deficiency Check · COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1434547
27 March 1997
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1095706
30 June 1996
Re-Inspection
Physical examination · Activities Europe · Activity 1405930
2 November 1995
Deficiency Check
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1447504
24 August 1995
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1187393
30 June 1995
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1185908
18 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 166575
14 December 1994
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 836955
28 October 1994
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 868035
26 August 1994
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 868733
23 August 1994
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 862648
10 August 1994
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1422406
10 July 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 508376
8 July 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 865947
6 July 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1183040
27 June 1994
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1443481
8 September 1993
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1153553
4 August 1993
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1156305
14 July 1993
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1154810
27 January 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 105083
13 December 1992
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 828035
13 December 1992
Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 848265
8 September 1992
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 497637
4 September 1992
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 935132
3 September 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 942123
29 July 1992
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1321387
24 July 1992
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1264363
21 July 1992
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 953198
2 July 1992
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1261237
23 June 1992
Examination of Repairs
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1439326
22 June 1992
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1262279
27 May 1992
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1417452
22 May 1992
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1262271
18 November 1991
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 937551
9 October 1991
Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 932201
9 October 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 932203
3 October 1991
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 939558
31 July 1991
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1353266
22 July 1991
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 535070
13 August 1990
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 904892
28 July 1989
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 456504
28 July 1989
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1210144
21 July 1989
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1352814
20 July 1989
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1040548
20 July 1989
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1041642
19 July 1989
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1038615
19 July 1989
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1039556
13 June 1989
Permit to Proceed
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1033679
3 June 1989
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 510750
1 June 1989
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1039306
24 August 1988
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1039603
11 July 1988
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 894098
14 August 1987
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1030265
7 August 1987
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1335089
15 July 1987
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1325648
25 June 1987
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1331256
17 June 1987
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1315762
12 June 1987
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1007226
9 June 1987
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1004987
3 June 1987
Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1323190
18 April 1987
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1018314
3 April 1986
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 998417
2 April 1986
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1306129
12 September 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 985525
26 June 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 983712
1 May 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1288045
29 March 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1288861
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 June 2020
Resolved
Before the ship leaves port and at all times during the voyage all lifesaving appliances shall be in working order and ready for immediate use. LB #1 rudder needs repaired, loose handhold, unsecured exhaust cover and loose through-hull flange. Total persons allowed reduced to 135. 74 SOLAS (14) III/20.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 2 July 2020
Resolution: Accepted by ABS.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 June 2020
Resolved
The low pressure CO2 pre-discharge time delays are not adjusted to delay settings iaw OCMI approval letter for KOCAK class vessels. Resolve prior to carrying cargo. 74 SOLAS (14) I/11(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2020
Resolution: Accepted by ABS.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 25 June 2020
Resolved
Safety Management Certificate shall be issued to every ship. Vessel does not have a valid SMC; provide a valid SMC to the satisfaction ot the attending CG Marine Inspector. 74 SOLAS (14) IX/4.3
Action required: 702 - Prior to embarking on international voyage
Resolved 17 August 2020
Resolution: Vessel provided valid ABS issued Safety Management Certificate.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 June 2020
Resolved
Condition of the ship and equipment shall be maintained to provisions of present regulations to ensure ship is fit to proceed to sea without danger to ship or persons onboard. Troubleshoot smoke system power failure alarm on bridge. 74 SOLAS (14) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 2 July 2020
Resolution: Accepted by ABS.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 June 2020
Resolved
Condition of ship and equipment maintained to ensure no danger to ship or crew. Wasted kick pipes at aft bulkhead of LP CO2 space. Port shore power box outside LP CO2 space has wasted mounts. Wasted potable water line outside 2nd deck engine room space. 74 SOLAS (14) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 2 July 2020
Resolution: Accepted by ABS.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 25 June 2020
Resolved
Condition of the ship and equipment shall be maintained to provisions of present regulations to ensure ship is fit to proceed to sea without danger to ship or persons onboard. Deck iwo lifeboat #4 at boat deck level is wasted. Wastage on deck around and under "C" switchboard in engine room. 74 SOLAS (14) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 2 July 2020
Resolution: Accepted by ABS.
09 - Working and Living Conditions › 092 - Working Conditions › Stowage of cargo
Issued 25 June 2020
Resolved
Condition of the ship and equipment shall be maintained to provisions of present regulations to ensure ship is fit to proceed to sea without danger to ship or persons onboard. Number 8 cargo hold door inboard ram leaking hydraulic fluid. 74 SOLAS (14) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 2 July 2020
Resolution: Accepted by ABS>
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 25 June 2020
Resolved
Condition of the ship and equipment shall be maintained to provisions of present regulations to ensure ship is fit to proceed to sea without danger to ship or persons onboard. Watertight exhaust closure to shaft alley cannot be operated remotely, it's to remain closed u/w until auto control is restored. 74 SOLAS (14) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 2 July 2020
Resolution: Accepted by ABS.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 25 June 2020
Resolved
Condition of ship and equipment maintained to ensure no danger to ship or crew. Sound powered phone on bridge did not audibly sound. 74 SOLAS (14) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 25 June 2020
Resolution: Sound powered phone on bridge wing was repaired by ship's electrician.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 June 2020
Resolved
Lifesaving appliances and arrangements shall be approved by the Administration. Bridge wing self-activating smoke signals are not Coast Guard approved. 74 SOLAS (14) III/4.1
Action required: 10 - Deficiency Rectified
Resolved 25 June 2020
Resolution: Coast Guard approved self-activating smoke signals were procured and installed on bridge wing lifebuoys.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 June 2020
Resolved
Posters or signs shall be provided in the vicinity of survival craft to illustrate procedures for operating the appliance and give instructions or warnings. Port, aft liferaft launching station had no instructions posted. 74 SOLAS (14) III/9.2.3
Action required: 10 - Deficiency Rectified
Resolved 25 June 2020
Resolution: Vessel crew installed new poster with instructions for launching liferafts.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 June 2020
Resolved
Condition of ship and equipment maintained to ensure no danger to ship or crew. Missing and wasted handrails iwo firestation Nos. 45 & 49. 74 SOLAS (14) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 25 June 2020
Resolution: Ship's crew installed new handrails at firestation Nos. 45 & 49.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 June 2020
Resolved
Condition of ship and equipment maintained to ensure no danger to ship or crew. Wasted deck mounts for ladder outside LP CO2 space. 74 SOLAS (14) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 25 June 2020
Resolution: Deck mounts for ladder were renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 November 2018
Resolved
All open lifeboats are to be inspected IAW MISB-004-18 Job Aid.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2019
Resolved 30 April 2019
Resolution: CIC started with defs noted
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 November 2018
Resolved
#4 Lifeboat shaft union sheared a pin and the hose between packing gland and shaft log is delaminating and cracking. Replace to OEMs recommendations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2019
Resolved 25 June 2020
Resolution: Cleared at COI inspection; Activity 6983503.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 November 2018
Resolved
#4 Lifeboat has an exhaust leak in the bellow from the turbo, replace to OEM recommendation.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2019
Resolved 25 June 2020
Resolution: Cleared at COI inspection; Activiy 6983503.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 November 2018
Resolved
#2 Lifeboat has an exhaust leak aft of the manifold that is leaking cooling water too. repair to OEM specs.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2019
Resolved 25 June 2020
Resolution: Cleared at COI inspection; Activity 6983503.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 November 2018
Resolved
#3 lifeboat's hose between packing gland and shaft log is delaminating and cracking. Replace to OEMs recommendations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2019
Resolved 25 June 2020
Resolution: Cleared at COI inspection; Activity 6983503.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 29 November 2018
Resolved
Lifeboats had only 5% of thermal protective aids, all boats should be outfitted with 10%.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2019
Resolved 25 June 2020
Resolution: Cleared at COI inspection; Acitvity 6983503.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 November 2018
Resolved
Place all primary lifesaving equipment into ready for sea positions
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 30 May 2019
Resolved 25 June 2020
Resolution: Cleared at COI inspection; Activity 6983503.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 November 2018
Resolved
Vessel had a flare back in starboard boiler uptake causing damage and making it inoperable. Repair and show proper operation to the satisfaction of the attending ABS Surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2019
Resolution: Received Surveyor's Report #NN3604773 attesting to satsifactory repairs were made.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 1 November 2018
Resolved
Vessel reported emergency generator would not start. Show proper operation of emergency generator to satisfaction of attending ABS Surveyor prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2019
Resolution: ABS & USCG were in attendance jointly & witnessed satisfactory operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 September 2018
Resolved
The main and auxiliary machinery, electrical installations and other equipment are in all respects satisfactory for the service the ship was intended. One of the ships primary electrical generators has an inoperable turbo. Complete repairs to the satisfaction of the class society. At least one diesel generator and the steam turbine generator shall be proven operable prior to departure. 74 SOLAS Chpt 1/ reg 11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 November 2018
Resolution: Received ABS Surveyor [name withheld]3577517.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 4 May 2018
Resolved
Vessel reported bus tie between main switchboard and emergency switchboard not functioning correctly. Repair bus tie to the satisfaction of class. (SOLAS 60 I/11.)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2018
Resolved 20 March 2019
Resolution: ABS & USCG were in attendance jointly & witnessed satisfactory operation.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 4 May 2018
Resolved
LPCO2 tank level is less than required. Check for leaks and top off system to the satisfaction of ABS Surveyor and prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2018
Resolved 6 February 2019
Resolution: Received Surveyor's Report #NN3604773 attesting to satisfactory repairs.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 25 April 2018
Resolved
Upon activation vessel to provide MMCs for all crew members when vessel is fully crewed iaw COI manning to USCG inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2019
Resolution: Vessel met minimum safe manning IAW their COI.
Navigation › Piloting/Steering › Marine Charts
Issued 25 April 2018
Resolved
Vessel doesn't keep up to date charts and pubs due to ROS. Vessel is to provide charts and pubs prior to activation to USCG inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2019
Resolution: Vessel provided up to date charts and publications.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 25 April 2018
Resolved
Vessel is to conduct drills to USCG inspector prior to activation.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2019
Resolution: Vessel completed satisfactory fire and abandon ship drill.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 25 April 2018
Resolved
In all cases of watertight doors, indicators shall be fitted which show whether the doors are open or closed. Watertight door indicator bulbs on bridge are inoperable. Repair to the satisfaction of class. SOLAS 74 I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 12 September 2018
Resolution: Cleared to satisfaction of attending Marine Inspector.
Fire Fighting › Structural - A Class Divisions › Control Stations
Issued 25 April 2018
Resolved
Open pipe penetrations through the deck within the electronics room below the speed log panel and the CO2 pull station on the bridge were found. Verify there is a sufficient amount of fire stop to enclose structural fire protection boundary penetrations to the satisfaction of class. SOLAS 74 I/11
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 25 April 2018
Resolution: Crew placed additional approved fire stop material in the boundary penetrations.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 April 2018
Resolved
The screen guard for the upper CO2 bottle storage space exhaust fan was wasted away, presenting a rotating machinery hazard to the crew. Rectify to the satisfaction of class. SOLAS 74 I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 10 September 2018
Resolution: Exhaust Fan screen was replaced to satisfaction of class.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 25 April 2018
Resolved
Firefighting systems and appliances shall be kept in good working order. The primary release station for the bosuns stores, located within the CO2 bottle storage space, was missing its safety glass. Rectify to the satisfaction of class. 74 SOLAS (12) II-2/14.2.2.1.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 25 April 2018
Resolution: Crew placed type approved glass in the pull station.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 25 April 2018
Resolved
Muster and embarkation stations shall be adequately illuminated. Number 1 lifeboat embarkation station light is broken off its mount. Repair to the satisfaction of class. SOLAS 74 III/19
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 25 April 2018
Resolution: Embarkation light was reinstalled as designed and for its intended use.
Lifesaving › Lifejacket/PFD (Type II) › Storage
Issued 25 April 2018
Resolved
The lifejacket donning instruction placards found throughout the vessel were not updated for the type II lifejackets in use. 74 SOLAS III/25
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 25 April 2018
Resolution: Crew posted the required up to date donning instructions throughout the vessel.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 25 April 2018
Resolved
Ship service generator crank case breather vent on number 3 lifeboat deck found to be wasted. Repair to the satisfaction of class. SOLAS 74 I/11.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 10 September 2018
Resolution: Repaired to the satisfaction of class
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 24 April 2018
Resolved
Numerous breakers on the emergency switchboard were identified as not working properly. Repair to the satisfaction of class. 74 SOLAS II-1/26
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 10 September 2018
Resolution: Emergency switchboard breakers were over hauled to the satisfaction of class
Electrical › Lighting (emergency) › Lighting Fixture
Issued 24 April 2018
Resolved
Emergency lighting at the e-gen switchboard was inoperable. Repair to the satisfaction of class.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 10 September 2018
Resolution: Was Repaired to the satisfaction of class.
Fire Fighting › Remote Fuel Shutoff › General
Issued 24 April 2018
No resolution recorded
Remote operated fuel valves were observed to not function properly. Repair & demonstrate proper operation to the satisfaction of class. 74 SOLAS II-1/26
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018 — due date passed with no resolution recorded
Engineering › Bilge Water Management System › Interface Detector
Issued 24 April 2018
Resolved
Shaft alley bilge high level alarm was not operational. Repair & demonstrate proper operation to the satisfaction of class. 74 SOLAS I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 17 May 2018
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 24 April 2018
Resolved
Engine room automatic fire dampers were not ready for inspection. Demonstrate proper operation of all dampers to the satisfaction of class & USCG prior to getting underway. 74 SOLAS I/11
Action required: 17 - Rectify deficiencies prior to departure
Due 25 May 2018
Resolved 1 June 2018
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 24 April 2018
Resolved
Mechanical watertight door indicator on the 2nd deck is inoperable. Repair & demonstrate to the satisfaction of class. 74 SOLAS I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 12 October 2018
Resolution: Received documentation attesting that the CG-835 requirement was cleared ABS surveyor [name withheld] on 9 October 18.
Engineering › Steering Gear System › Pump
Issued 24 April 2018
Resolved
Starboard steering gear pump was found leaking hydraulic oil excessively. Repair and demonstrate proper operation to the satisfaction of class. 74 SOLAS I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 10 September 2018
Resolution: Repaired and cleared to the satisfaction of class.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 24 April 2018
Resolved
Steering gear room was found with excessive amounts of oil on the deck. Clean up for inspection to the satisfaction of class. MARPOL Annex 1 Reg. 6.4.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 10 September 2018
Resolution: Room was degreased and found satisfactory to Class Surveyor
Engineering › Freshwater System (air cooling) › Level Control
Issued 24 April 2018
Resolved
Emergency generator radiator was missing its cap. Replace to the satisfaction of class. 74 SOLAS I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 10 September 2018
Resolution: Cap was replaced tpo the satisfaction of class.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 24 April 2018
Resolved
MSD overboard discharge was found unsecured. Secure overboard discharge to the satisfaction of class. 33 CFR 159.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 10 September 2018
Resolution: Verified by ABS Surveyor
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 April 2018
Resolved
OWS was not avaailable for inspection by USCG. Make OWS available for inspection to the satisfaction of class & USCG.
MARPOL Annex 1 Reg 14
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 11 October 2018
Resolution: Witnessed full operation of the OWS.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 24 April 2018
Resolved
Oil wast tanks were at full capacity. Remove/pump oil wast to a reception facility or have OWS repaired & inspected to the satisfaction of class prior to getting underway. MARPOL Annex 1 Reg 6.4.1
Action required: 17 - Rectify deficiencies prior to departure
Due 25 May 2018
Resolved 10 September 2018
Resolution: No. 5P and No.5S were verified in slack condition
Electrical › Electrical Distribution System (service) › Panelboard
Issued 24 April 2018
Resolved
Lower machinery space, starboard power panel, breaker #6 was found broken. Repair to the satisfaction of class. 74 SOLAS I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 10 September 2018
Resolution: Repaired and tested to the satisfaction of class
Electrical › Electrical Distribution System (service) › Panelboard
Issued 24 April 2018
Resolved
Workshop power panel P4 #6 breaker for the cargo hold A/C compressor was found broken. Repair to the satisfaction of class. 74 SOLAS I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 10 September 2018
Resolution: Repaired and tested to the satisfaction of class
Electrical › Lighting (emergency) › Lighting Fixture
Issued 24 April 2018
Resolved
Emergency escape lighting in way of the emergency fire pump was broken. Repair to the satisfaction of class. 74 SOLAS I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 17 May 2018
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 24 April 2018
No resolution recorded
Extensive amounts of work tools are scattered throughout the engine room. Secure tools for sea prior to getting underway to the satisfaction of the CGMI. 74 SOLAS I/11
Action required: 17 - Rectify deficiencies prior to departure
Due 25 May 2018 — due date passed with no resolution recorded
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 24 April 2018
Resolved
Excessive amounts of water was observed in the shaft alley and engine room. Remove water from bilges to the satisfaction of class. MARPOL Annex 1 Reg 6.4.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 17 May 2018
Fire Fighting › Fire Main › Material
Issued 27 February 2018
Resolved
Vessel has dime-sized hole in the fire main pipe near frame 65 on the 2nd deck. Repair fire main pipe to the satisfaction of class and the U.S. Coast Guard. 74 SOLAS 14 II-2/10.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 March 2018
Lifesaving › Lifeboat › Propulsion Engine
Issued 23 February 2018
Resolved
Vessel's no. 4 lifeboat is inoperable. Before the ship leaves port and at all times during the voyage all life-saving appliances shall be in working order and ready for immediate use. Repair lifeboat to the satisfaction of class and the USCG. 74 SOLAS 14 III/20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2018
Resolved 24 April 2018
Resolution: Witnessed a satisfactory test of the #4 lifeboat engine during the ACP targeted oversight inspection.
Lifesaving › Lifeboat › Propulsion Engine
Issued 23 February 2018
Resolved
Vessel's No. 1 lifeboat has a water leak from a cracked lube oil cooler. Repair lifeboat to the satisfaction of class and the U.S. Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 5 March 2018
Resolved 17 May 2018
Lifesaving › Lifeboat › Propulsion Starting System
Issued 23 February 2018
Resolved
Vessel's No. 2 lifeboat has a hydraulic leak on the pressure accumulator for the starting mechanism. Repair lifeboat to the satisfaction of class and the U.S. Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 April 2018
Construction/Loadline › Structures › Door
Issued 1 December 2017
No resolution recorded
Means for securing and maintaining weather tightness shall be to the satisfaction of the administration. The arraignment shall ensure that the tightness can be maintained in any sea condition. 13 dogs for cargo hatch covers not operating, (2) 3AS, (3) 3CS, (3) 2AC, (2) AS and (3) 1S. Prove proper operation of all hatch dogs to attending Coast Guard Marine Inspector prior to carrying cargo. L/L CH II Reg 16 (4)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018 — due date passed with no resolution recorded
Construction/Loadline › Structures › Ventilators
Issued 30 November 2017
Resolved
All access openings in bulkhead at ends of enclosed superstructures shall be fitted with doors of steel and weather tight when closed. Make repairs to the WTD's for cargo ramp stern door, LP CO2 room and port and starboard focsle. L/L CH II Reg 12 (1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 November 2017
Construction/Loadline › Structures › Ventilators
Issued 30 November 2017
Resolved
Ventilators passing through superstructure other than enclosed superstructure shall have substantial constructed comings of steel or other equivalent material at the freeboard deck. Make repairs to ventilation ducting through bulkhead port side weather deck by accom. ladder aft of LP CO2 room. L/L CH II Reg 19 (2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 November 2017
Construction/Loadline › Structures › Door
Issued 30 November 2017
Resolved
Cargo ports and other similar openings in the sides of ships below the freeboard deck shall be fitted with doors so designed as to ensure weather tightness. Make repairs to starboard side bunkering side shell door gasket and knife edge. L/L CH II Reg 21 (1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 November 2017
Construction/Loadline › Structures › Deck Plating
Issued 30 November 2017
Resolved
Openings in freeboard decks shall be protected by enclosed superstructure and weather tightness Make repairs to deck penetration under accom. ladder console, cement temp repair installed for transit. L/L CH II Reg 18 (2) PRIOR TO CARGO OPS
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 12 March 2018
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 30 November 2017
Resolved
All ventilation systems shall be capable of being closed from outside the space, make repairs to engine room STB exhaust, port supply and starboard supply ventilation louvers. 74 Solas CH II-2 25 (c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 November 2017
Construction/Loadline › Structures › Ventilators
Issued 30 November 2017
Resolved
Ventilators passing through superstructure other than enclosed superstructure shall have substantial constructed comings of steel or other equivalent material at the freeboard deck. Make repairs to ventilation ducting through bulkhead in upper LP CO2 compartment. L/L CH II Reg 19
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 November 2017
Lifesaving › Lifeboat › Propulsion Engine
Issued 30 November 2017
Resolved
On each side of the vessel at least one boat with compression ignited engine capable of carrying each person onboard. Lifeboat #3 engine not operating. Solas 74 CH III Reg 9 (a) (i), not to carry more than 48 persons. PRIOR TO CARGO OPS
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 11 April 2018
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 30 November 2017
Resolved
Where class "A" divisions are pierced for the passage of electrical cables, arraignments shall be made to ensure fire resistance not impaired, Properly run cable from engine room to engineering state rooms, temp fire stop installed. Solas 74 CH II-2 Reg 23 (a) PRIOR TO CARGO OPS
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 25 April 2018
Resolution: Deficiency was cleared by [name withheld] on 24 April 2018.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 30 November 2017
Resolved
When carbon dioxide is used as an extinguishing medium both for cargo and machinery spaces of class A the quantity of gas need not be more than the maximum required. Correct discharge time delay bottle for hold #2. Solas 74 CH II-2 Reg 8 (d) (iv) PRIOR TO CARGO OPS
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 27 February 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 November 2017
Resolved
Cables and wiring shall be installed and supported in such a manner to avoid chafing or other damage. Mount electrical boxes for engine room supply ventilation port and starboard actuators, use approved boxes. Solas Ch II-2 Reg 45 5.5 PRIOR TO CARGO OPS
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 25 April 2018
Resolution: Deficiency was cleared by [name withheld] on 25 April 2018.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 30 November 2017
Resolved
Each lifeboat shall be provided with an appliance which is capable of launching and recovering the lifeboat. Prove launching and recovery of Lifeboat #3 break/clutch/bearing, not to carrying more than 48 passengers. Solas CH III Reg 16.2 PRIOR TO CARGO OPS
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 13 April 2018
Construction/Loadline › Structures › Ventilators
Issued 30 November 2017
Resolved
Ventilators passing through superstructure other than enclosed superstructure shall have substantial constructed comings of steel or other equivalent material at the freeboard deck. Make weather tight natural ventilation covers port and starboard side focsle, temp seal for transit. L/L CH II Reg 19 PRIOR TO CARGO OPS
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 25 April 2018
Resolution: Deficiency was cleared by [name withheld] on 25 April 2018.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 24 May 2017
Resolved
As the vessel is in an ROS status, vessel crew must demonstrate fire and abandon ship drills to the satisfaction of the CG MI prior to port departure.
Action required: 705 - Other - as specified
Resolved 10 August 2017
Resolution: Drill performed to the satisfaction of attending CGMI.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 24 May 2017
Resolved
As the vessel is in an ROS Status and minimally manned, vessel crew must present all licenses and endorsements as required by the COI to the satisfaction of the CGMI prior to port departure.
Action required: 705 - Other - as specified
Resolved 10 August 2017
Resolution: All MMC valid for crew.
Navigation › Piloting/Steering › Marine Charts
Issued 24 May 2017
Resolved
As the vessel is in an ROS status, vessel crew must present current and corrected charts and publications to the satisfaction of the attending CG MI prior to port departure.
Action required: 705 - Other - as specified
Resolved 10 August 2017
Resolution: All charts for voyage verfied to be good.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 23 January 2017
Resolved
Vessel's Annual ACP Oversight Exam was due to be completed prior to 29 Nov 2016. Complete all Administration surveys req'd by applicable IMO Conventions to the satisfaction of an attending ABS surveyor, and complete an Annual ACP Oversight Exam to the satisfaction of an attending USCG Marine Inspector, prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 January 2017
Resolved 24 May 2017
Resolution: Vessel completed ACP Annual survey.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 17 November 2015
Resolved
Due to ROS status, vessel was unable to provide licenses and endorsements of the capatain and crew. Vessel is to provide all licenses and endorsements to the satisfaction of a marine inspector prior to activation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 November 2015
Resolution: Vessel provided satisfactory licenses and endorsements of the captain and crew.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 17 November 2015
Resolved
Due to ROS status, vessel was unable to demonstrate a fire and abandon ship drill to the satisafaction of a marine inspector. Vessel is to demonstrate these drills prior to activation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 November 2015
Resolution: Vessel conduct satisfactory fire and abandon ship drills.
Navigation › Piloting/Steering › Marine Charts
Issued 17 November 2015
Resolved
Due to ROS status, vessel was unable to provide up to date charts and publications. Vessel is to provide updated charts and publications to the satisfaction of a marine inspector prior to activation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 November 2015
Resolution: Vessel provided updated charts and navigation publications.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 17 November 2015
Resolved
Starter hand crank for lifeboat #3 does not work as designed. Prove proper operation of #3 lifeboat with repaired hand crank to the satisfaction of a class surveyor.
Action required: 705 - Other - as specified
Resolved 24 November 2015
Resolution: ABS provided class report stating that the handcrank engagement and operation was verified to the staisfaction of an attending surveyor.
Electrical › Electrical Distribution System (emergency) › Circuit Breaker
Issued 17 November 2015
Resolved
Found Personnel Elevator, IC Battery Charger, and Aft Air Compressor #2 breakers on Emergency Switchboard to be overrated. Replace with appropriately sized breakers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 24 November 2015
Resolution: ABS provided class report stating suspect breakers were repalced and found to be satisfactory by and attending surveyor.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 17 November 2015
Resolved
Found watertight shaft alley ventilation closure to remain open after operation. Repair or adjust to provide watertight boundary.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 November 2015
Resolution: ABS provided class report stating that butterfly valve was replaced and limit torgue actuator stops were adjusted. Ventilation system was teasted and found satisfactory to an attending surveyor.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 17 November 2015
Resolved
Found main bus frequency meter to be removed. Replace with functioning meter.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 24 November 2015
Resolution: ABS provided class report stating that vessel installed new frequency meter and accuracy was verified by an attaending surveyor.
Fire Fighting › Fire Pumps › Pressure
Issued 17 November 2015
Resolved
Found local pressure gauge for emergency fire pump to be inoperable. Replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 November 2015
Resolution: ABS provided class report stating that vessel installed new pressure guage and pump was operationally tested to the satisfaction of attending surveyor.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 November 2015
Resolved
Crew was unable to test Oily Water Separator. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 November 2015
Resolution: ABS provided class report stating that OWS system was retested and found to be functional to that satisfaction of an attending surveyor.
Engineering › Pressure Vessel › Pressure Gauge
Issued 17 November 2015
Resolved
Found pressure gauge of Emergency Diesel Generator hydraulic starting system to be broken and inoperable. Replace in kind.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 24 November 2015
Resolution: ABS provided class report staing pressure guage was renewed and operation verified by an attending surveyor.
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (hydraulic)
Issued 17 November 2015
Resolved
Emergency generator hydraulic start system has hoses with bulges and leaks. Replace all hoses to the satisfaction of class, prior to getting underway.
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 24 November 2015
Resolution: ABS provided class report stating that all suspect hoses were replaced and tested for tightness and operation to the satisfaction of an attending surveyor.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 19 August 2014
Resolved
Due to ROS status, vessel was unable to provide licenses and endorsements of the captain and crew. Vessel is to provide all licenses and endorsements to the satisfaction of a marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2015
Resolution: Vessel is fully manned in compliance with Certificate of Inspection; verified all licenses/endorsements - sat.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 19 August 2014
Resolved
Due to ROS status, vessel was unable to demonstrate a fire and abandonship drill to the satisfaction of a marine inspector. Vessel is to demonstrate these drills prior to activation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2015
Resolution: Witnessed satisfactory fire and abandon ship drill.
Navigation › Piloting/Steering › Marine Charts
Issued 19 August 2014
Resolved
Due to ROS status, vessel was unable to provide up to date charts and publications. Vessel is to provide charts and pubs to the satisfaction of a marine inspector prior to activation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2015
Resolution: Verified all charts and publications were current and up-to-date - sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 August 2014
Resolved
Vessel does not have a valid fire fighting servicing report. Provide a copy of the servicing report attesting to the satisfactorily inspection of the firefighting equipment and low pressure CO2 system to the satisfaction of a marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2014
Resolution: Vessel provided to marine inspector a completed fire fighting servicing report attesting the completion of servicing all fixed fighting equipment onboard the vessel.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 6 May 2009
Resolved
Disposable hydrostatic releases on liferafts expired FEB09. Prior to departure the Port of Guam, provide and install serviceable/current hydrostatic releases on liferafts for a minimum aggregate capacity of 100% of the total persons onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2009
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 6 May 2009
Resolved
All remaining expired hydrostatic releases installed on liferafts required by the vessels COI and/or SOLAS Cargo Ship Safety Equipment Certificate must be replaced upon completion of current voyage from Guam to the U.S.
Action required: 15 - Rectify deficiencies by next port
Due 7 May 2009
Resolved 12 June 2009
Resolution: Complete.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 June 2008
Resolved
Replace cracked lifebuoy light port side aft and prove proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2008
Resolved 23 June 2008
Resolution: Light was replaced and tested satisfactory.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 June 2008
Resolved
Install batteries and prove proper operation of starboard aft lifebuoy light.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2008
Resolved 23 June 2008
Resolution: Batteries installed and light tested satisfactory.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 June 2008
Resolved
Install batteries in port bow lifebuoy light and prove proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2008
Resolved 23 June 2008
Resolution: Batteries installed and light tested satisfactory.
Electrical › Lighting (service) › Lighting Fixture
Issued 23 June 2008
Resolved
Replace missing lighting fixture lens over starboard steering motor.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2008
Resolved 23 June 2008
Resolution: Lens was replaced.
Electrical › Lighting (service) › Lighting Fixture
Issued 23 June 2008
Resolved
Repair or replace lighting fixture lens cover mounting on centerline lighting fixture in steering gear room.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2008
Resolved 23 June 2008
Resolution: Lens cover repaired.
Communications › Alarms/Indicators › General Alarm
Issued 23 June 2008
Resolved
Prove proper operation of general alarm bell in surge lounge.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2008
Resolved 23 June 2008
Resolution: Alarm was replaced and tested satisfactory.
Engineering › Bilge Water Management System › Piping
Issued 15 January 2008
Resolved
Make permanent repairs to supply piping to oily water separator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2008
Resolution: Piping replaced from OWS to tank connection piping, pressure tested at 20psi for 30 minutes, test satisfactory.
Engineering › Bilge Water Management System › Valve
Issued 15 January 2008
Resolved
Make permanent repairs and prove proper operation of oil discharge solenoid on oily water separator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2008
Resolution: ABS surveyor and USCG inspector witnessed satisfactory test.
Engineering › Bilge Water Management System › Valve
Issued 15 January 2008
Resolved
Repair reach rod for number five (5) port oily water holding tank suction valve to oily water separator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2008
Resolution: Reach rod repaired and operates satisfactory.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 15 January 2008
Resolved
Provide non-conductive deck covering in front of electrical panel (F.O. service pump#1) in engine control room.
Action required: 705 - Other - as specified
Due 15 February 2008
Resolved 30 January 2008
Documentation › Logs/Records › Oil Record Book
Issued 15 January 2008
Resolved
Provide proper entries in oil record book in accordance with MARPOL 73/78 Annex I/Reg. 20. Ensure entries are logged in accordance with instructions given in the beginning of the book and in MARPOL 73/78 Annex 1/Appendix III, especially concerning C11, C12, D15.3, and E17 for all tanks listed in IOPP Form B part 3.1. Extended due date to date for annual ACP examination.
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 23 June 2008
Resolution: Vessel Chief Engineer ensures all entries are in accordance with MARPOL and oil record book instructions.
Documentation › Certificates/Documents › IOPP Certificate
Issued 15 January 2008
Resolved
Amend IOPP Form B, part 3 to clarify identification of tanks and their respective locations and capacities.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2008
Resolved 13 February 2008
Resolution: ABS issued a new full term form B with tanks and locations identified.
Operations/Management › Pollution › Compliance with Transfer Procedures
Issued 15 January 2008
Resolved
Provide transfer procedures for tank to tank transfers in accordance with 33 CFR 155.720(b).
Action required: 705 - Other - as specified
Due 15 February 2008
Resolved 6 February 2008
Resolution: Reviewed procedures, procedures are IAW 33 CFR 155.720(b).
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 15 January 2008
Resolved
Provide an external ISM audit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2008
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 January 2008
Resolved
Prove proper operation of oily water separator.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2008
Resolved 12 February 2008
Resolution: ABS surveyor and USCG inspector witnessed satisfactory test.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 15 August 2003
Resolved
THE CO2 ACTUATOR SYSTEM FOR THE BOSUN STORE IS NOT OPERATING PROPERLY. UNTIL CLASS VERIFIES NORMAL OPERATION, THE SPACE MUST EITHER BE A) LOCKED, OR B) HAVE A WATCH OUTSIDE THE SPACE WHEN CREWMEMBERS ARE INSIDE TO NOTIFY THEM OF POSSIBLE FIRE DANGERS. LEGACY COMPONENT DESC: Operating Controls
Action required: 705 - Other - as specified
Due 25 August 2003
Resolved 22 September 2003
Resolution: Received ABS Survey report stating the requirement had been completed and witnessed by ABS in the shipyard in Mobile, Alabama. Vessel is enrolled in the USCG/ACP.
Engineering › Fuel Oil Service System
Issued 24 July 2003
Resolved
Vessel granted 90 day extension to SOLAS II-2 regulation 15.2.9 and 11; high pressure fuel line spray shields, leak off collection and alarms. Regulation must be meet by 01OCT03. See activity for details. LEGACY COMPONENT DESC: Piping
Due 1 October 2003
Resolved 22 September 2003
Resolution: Received ABS Survey report stating the requirement had been completed and witnessed by ABS in the shipyard in Mobile, Alabama. Vessel is enrolled in the USCG/ACP.
Engineering › Steering Gear System
Issued 26 February 2003
Resolved
AFTER REPAIRS TO STEERING SYSTEM TO ELIMINATE MINOR INTERRUPTION IN MOVEMENT FROM MIDSHIP TO RIGHT RUDDER BETWEEN 0 AND 5 DEGREEES - DEMONSTRATE TO LOCAL [name withheld]: Follow-up Assembly
Condition: Unknown
Due 26 March 2003
Resolved 2 March 2003
Resolution: WITNESSED SATISFACTORY OPERATION OF STEERING GEER IN ALL MODES OF OPERATION WITH NO INTERRUPTION OF RUDDER MOVEMENT WITH EITHER PUMP OPERATING.
Engineering
Issued 28 April 1999
Resolved
PROVIDE CONTAINMENT AROUND CARGO TANK VENTS (PV VALVES) 2 EA FORWARD OF THEHOUSE MIDSHIPS AND PORT SIDE IN ACCORDANCE WITH 33 CFR 155.310. TO BE COMPLETED AT NEXT DRYDOCK.
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999
Construction/Loadline
Issued 22 July 1998
Resolved
created for MV detection case...
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Engineering
Issued 16 April 1998
Resolved
Make proper permanent repairs to water wall tubes in port and stbd boilers (1 in each) which have temporary weld repairs, to satisfaction of an attending marine inspector at next drydocking. Alternatively, provide appropriate documentation from manufacturer allowing repairs as permanent.
Condition: Unknown
Due 16 April 1998
Resolved 16 April 1998
Fire Fighting
Issued 16 April 1998
Resolved
Repair or renew inoperative cargo hold vent breaker P-29. Breaker is needed for manual remote and LP CO2 emergency ventilation trips. Re-test to satisfaction of attending Coast Guard Marine Inspector or ABS surveyor [name withheld] witnesses re-test, provide appropriate survey report via telefax.
Condition: Unknown
Due 16 April 1998
Resolved 16 April 1998
Lifesaving
Issued 30 June 1995
Resolved
COMPLETED SERVICING OF ALL LIFERAFT AND PROPERLY INSATAL ONBOARD VSL BEFORESAILING.
Condition: Unknown
Due 19 July 1995
Resolved 19 July 1995
Deck/Cargo
Issued 30 June 1995
Resolved
CONDUCT ANNUAL HYDROSTATIC TESTS ON ALL CARGO/OIL TRANSFER HOSES.
Condition: Unknown
Due 19 July 1995
Resolved 19 July 1995
Engineering
Issued 30 June 1995
Resolved
CONDUCT BOILER FIRESIDE AND WATER SIDE EXAM NOT LATER THAN 31DEC95. COAST GUARD INSPECTOR MUST BE PERSENT
Condition: Unknown
Due 30 June 1995
Resolved 30 June 1995
Construction/Loadline
Issued 30 June 1995
Resolved
CONDUCTED WATER TEST OF ALL DECK DEPARTMENT WATER TIGHTDOORS AT NEXT DRYDOCK.
Condition: Unknown
Due 30 June 1995
Resolved 30 June 1995
Navigation
Issued 30 June 1995
Resolved
PROVIDE PROPER OPERATION OF BOTH VSL'S RADARS BEFORE SAILING.
Condition: Unknown
Due 30 June 1995
Resolved 30 June 1995
Fire Fighting
Issued 30 June 1995
Resolved
CONDUCTED TEST OF CARGO HOLD WATER SPRINKLER SYSTEM NOT LATER THAN NEXT DRYDOCK.
Condition: Unknown
Due 30 June 1995
Resolved 30 June 1995
Accommodation/Occupational Safety
Issued 30 June 1995
Resolved
PERMANENTLY REPAIR SEWAGE TANK VENT PIPING.
Condition: Unknown
Due 30 June 1995
Resolved 30 June 1995
Accommodation/Occupational Safety
Issued 30 June 1995
Resolved
PROVE PROPER OPERATION OF DECKHOUSE VENTILATION CIRCUIT BREAKERS DURING REMOTE SHUTDOWN OPS.
Condition: Unknown
Due 30 June 1995
Resolved 30 June 1995
Lifesaving
Issued 30 June 1995
Resolved
INSTALL ELETRICAL GRADE MATTING IN FRONT OF ALL MACHINE SHOP SWITCH GEAR ELETRICAL PANELS.
Condition: Unknown
Due 30 June 1995
Resolved 30 June 1995
Engineering
Issued 23 August 1994
Resolved
Repair & demonstrate repair to leaking expansion bellows joint on port boiler drum safety steam escape discharge piping.
Condition: Unknown
Due 23 August 1994
Resolved 23 August 1994
Lifesaving
Issued 27 June 1994
Resolved
CARGO A/C UNITS #1 AND #2 RELIEF VALVE DISCHARGE PIPING CONTAINS STOP VALVES WHICH ARE NOT I.A.W. 46 CFR 56.50-20(C). REMOVE VALVES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Engineering
Issued 27 June 1994
Resolved
PROVIDE MANUFACTURING DATE OF MAIN CONDENSOR S/W FLEX LINE CONNECTOR ADJACENT TO SEA SCOOP INTAKE_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Engineering
Issued 27 June 1994
Resolved
MAKE PERMANENT REPAIRS TO PORT BOILER MAIN DISCHARGE LINE, IN WAY OF LEAKING 3/4" CONDENSATE DRAIN LINE NIPPLE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 July 1994
Resolved 14 July 1994
Fire Fighting
Issued 27 June 1994
Resolved
REPLACE DAMAGED HOSE IN WAY OF HORNS ON ENGINEROOM CO2 HOSE REEL UNIT.
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Engineering
Issued 27 June 1994
Resolved
RENEW, OR PROVE ABILITY OF THE FUEL OIL SUCTION LINE IN THE ENGINEROOM UNDER THE MAIN CONDENSER TO MAINTAIN TIGHTNESS UNDER HYDROSTATIC PRESSURE TEST, I.W.O. HEAVILY CORRODED BUTT JOINT_x001C_ _x001C_
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Electrical
Issued 27 June 1994
Resolved
CORRECT WATER ACCUMULATION PROBLEM AROUND THE BACKSIDE AND UNDERNEATH AUX. SWBD. BHD SWEATING CREATING SUFFICIENT WATER TO CREATE AN ELECTRICAL SAFETY HAZARD._x001C_ _x001C_
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Construction/Loadline
Issued 27 June 1994
Resolved
REPAIR/REPLACE/REINSTALL REMOTE OPERATORS ON BALLAST DISCHARGE MANIFOLD FOR#2DBT FILL, #3DBT FILL, AFT PEAK
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Engineering
Issued 27 June 1994
Resolved
REPAIR LEAKING BELLOWS EXPANSION JOINT ON PORT BOILER DRUM SAFETY DISCHARGELINE
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Electrical
Issued 27 June 1994
Resolved
PROVE PROPER OPERATION OF #2 GEN L/O ALARMS AND SHUTDOWN DEVICES, NO WAY TOSIMILATE LOSS OF PRESSURE IN SENSING LINES
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Lifesaving
Issued 27 June 1994
Resolved
CARGO A/C UNITS #1 AND #2 R.V. DISCHARGE PIPING CONTAINS IMPROPER FLEX HOSES. REPLACE WITH HOSES MEETING 46 CFR 45.60-25.
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Engineering
Issued 27 June 1994
Resolved
REPLACE MISSING LIFTING GEAR ON THE FOLLOWING COMPRESSED AIR SYSTEM RELIEF VALVES, #1 START, #2 START, RED. STATION, #3 COMP. DIS.
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Lifesaving
Issued 14 July 1993
Resolved
INSTALL FLEXIBLE CONNECTION ON ALL THREE(03) AIR COMPRESSOR DISCHARGES.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Lifesaving
Issued 14 July 1993
Resolved
INSULATE #3 AIR COMPRESSOR DISCHARGE.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Engineering
Issued 14 July 1993
Resolved
RENEW OWS SALT WATER PIPING.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Electrical
Issued 14 July 1993
Resolved
INSTALL COVERS ON PRESSURE AND TEMPERATURE SWITCHES ON ALCO DIESEL GENERATOR.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Accommodation/Occupational Safety
Issued 14 July 1993
Resolved
INSTALL NEW RUPTURE DISC ON AFTER HOUSE A/C UNIT.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Fire Fighting
Issued 14 July 1993
Resolved
INSTALL NEW FLEX HOSES ON ENGINEROOM CO2 HOSE REEL.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Electrical
Issued 14 July 1993
Resolved
RENEW EMERGENCY BATTERY B1.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Engineering
Issued 14 July 1993
Resolved
REPAIR PORT FORCE DRAFT BLOWER EMERGENCY TRIPS.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Engineering
Issued 14 July 1993
Resolved
INSTALL NEW TIME DELAY CARD ON PORT BOILER CONSOLE.
Condition: Unknown
Due 22 July 1993
Resolved 22 July 1993
Engineering
Issued 14 July 1993
Resolved
RENEW BOILER BLOW SKIN VALVE TO SIDE SHELL.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Lifesaving
Issued 14 July 1993
Resolved
REPAIR BROKEN WIRE ON #3 LIFEBOAT FALLS LIMIT SWITCH.
Condition: Unknown
Due 22 July 1993
Resolved 22 July 1993
Construction/Loadline
Issued 14 July 1993
Resolved
REPAIR BROKEN PRIME CONNECTION ON ENGINEROOM PORT BILGE PUMP.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Construction/Loadline
Issued 14 July 1993
Resolved
INSTALL NEW MAIN CONDENSOR END BELL MAN HOLE COVERS IAW DRAWING CW2300CD USING CORRECT MATERIAL.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Fire Fighting
Issued 14 July 1993
Resolved
REPAIR/FREE UP EMERGENCY GENERATOR ROOM CO2 PULL BOX.
Condition: Unknown
Due 22 July 1993
Resolved 22 July 1993
Engineering
Issued 14 July 1993
Resolved
REPAIR AS NECESSARY THE PORT & STBD MAIN FEED STOP AND STOP CHECK VALVES.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Engineering
Issued 14 July 1993
Resolved
RENEW/REPAIR ROTTED PIPE ENGINEROOM AFT BULKHEAD STBD SIDE CONDENSATE RETURN.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Fire Fighting
Issued 24 July 1992
Resolved
PROVE PROPER OPERATION OF THE FOLLOWING FIRE DETECTION ZONES: SMOKE DETECTION FOR CARGO HOLD 3A 3RD DECK AND HEAT DETECTION FOR CARGO HOLDS 3A 3RD DECK & 4 3RD DECK.
Condition: Unknown
Due 31 July 1992
Resolved 31 July 1992
Accommodation/Occupational Safety
Issued 2 July 1992
Resolved
PROVIDE PLANS FOR APPROVAL AND VERIFY INSTALLATION AND MATERIALS FOR SURGE CREW QUARTERS MODIFICATIONS EFFECTED DURING JUNE 1992 YARD AVAILABILITY AT NORSHIPCO, NORFOLK, VA.
Condition: Unknown
Due 2 July 1992
Resolved 2 July 1992
Construction/Loadline
Issued 22 June 1992
Resolved
PROVE 1.5" PLUG VALVES FOR MAIN CIRCULATION PUMP, EMERGENCY FIRE PUMP, AND AUXILIARY SEA WATER CIRCULATION SUCTION SEA CHESTS CLEAN OUTS (3 TOTAL) EMPLOYING TEFLON PLUG MATERIAL COMPLY WITH THE REQUIREMENTS OF 46 CFR 56.50-95 AND 56.60 OR REPLACE WITH ACCEPTABLE VALVES.
Condition: Unknown
Due 22 June 1992
Resolved 22 June 1992
Lifesaving
Issued 31 July 1991
Resolved
PROVIDE ONE (1) ADDITIONAL CLASS "S" EPIRB; TOTAL OF TWO REQUIRED ABOARD VESSEL.
Condition: Unknown
Due 7 August 1991
Resolved 7 August 1991
Electrical
Issued 31 July 1991
Resolved
PROVE PROPER OPERATION OF THE HIGH WATER TEMPERATURE ALARM AND HIGH WATER TEMPERATURE SHUT-DOWN ON NUMBER TWO (2) SHIPS SERVICE DIESEL GENERATOR.
Condition: Unknown
Due 31 July 1991
Resolved 31 July 1991
Electrical
Issued 31 July 1991
Resolved
PROVE PROVER OPERATION OF THE LOW LUBE OIL ALARM ON NUMBER TWO (2) SHIPS SERVICE DIESEL GENERATOR.
Condition: Unknown
Due 31 July 1991
Resolved 31 July 1991
Lifesaving
Issued 21 July 1989
Resolved
MAKE PROPER REPAIRS TO NO. 4 LIFEBOAT WINCH BRAKE SO BRAKE DOES NOT BOUNCE EXCESSIVELY. HAVE TESTED UNDER THE FULLY LOADED CONDITION IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 21 July 1989
Resolved 21 July 1989
Engineering
Issued 20 July 1989
Resolved
DEMONSTRATE PROPER OPERATION OF THE LUBE OIL SERVICE PUMP AND THE MAIN CONDENSATE PUMP AS PER CG APPROVED AUTOMATION PROCEDURE PAGE 5 ITEM 1.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Engineering
Issued 20 July 1989
Resolved
MAKE SATISFACTORY REPAIRS TO THE LOW PRESSURE TURBINE
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Unknown
Issued 19 July 1989
Resolved
CONDUCT FIRE AND BOAT DRILL IN THE PRESENCE OF A COAST GUARD MARINE INSPEC-TOR
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
RENEW EMERGENCY LIGHTS THAT ARE EXTINGUISHED LOCATED ON THE WATER GAUGE GLASSES ON THE PORT BOILER.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
DEMONSTRATE PROPER OPERATION OF THE SSTG LOW LUBE OIL ALARM.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Lifesaving
Issued 19 July 1989
Resolved
CONDUCT DAVIT WEIGHT TEST FOR THE PORT DAVITS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Unknown
Issued 19 July 1989
Resolved
DEMONSTRATE PROPER OPERATION OF THE E.R. OILY DISCHARGE MONITOR
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Engineering
Issued 19 July 1989
Resolved
DEMONSTRATE PROPER OPERATION OF THE AUTOMATION SYSTEM AS PER CG APPROVED PROCEDURE PAGES 4-5, PAGE 6 ITEMS 3 & 6 & PAGE 7 ITEM 7
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Engineering
Issued 19 July 1989
Resolved
REPAIR OR REPLACE THE PORT BOILER DRUM PRESSURE GAUGE ON THE MAIN CONSOLE.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Engineering
Issued 19 July 1989
Resolved
CALIBRATE OR REPLACE THE SUPERHEATER GAUGES ON THE PORT & STBD BOILERS
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 3 June 1987
Resolved
INSTALL AN APPROVED EXPLOSION-PROOF GENERAL ALARM BELL IN THE PUMPROOM AND TEST TO THE SATISFACTION OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Fire Fighting
Issued 3 June 1987
Resolved
EFFECT PERMANENT REPAIRS TO MOTOR OPERATED VALVE #9 SERVICING VEHICLE HOLD FOAM SYSTEM AND TEST TO SATISFACTION OF A COAST GUARD MARINE INSPECTOR PRIOR TO DEPARTURE VESSEL'S NEXT PORT OF CALL, JACKSONVILLE, FLORIDA.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Fire Fighting
Issued 3 June 1987
Resolved
CALIBRATE BOTH LIQUID LEVEL GAUGES ON LOW PRESSURE CO2 STORAGE TANKS TO SATISFACTION OF CG MARINE INSPECTOR. PROVIDE [name withheld] BREAK- DOWN ON REQUIRED DISCHARGE TIME FOR MACHINERY SPACE & PERCENTAGE OF LIQUID FILL WHICH MUST BE MAINTAINED AT ALL TIMES IN CO2 STORAGE TANKS.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Engineering
Issued 3 June 1987
Resolved
INSTALL RELIEF VALVE ON CONTROL AIR RECEIVER WITH PROPER OPERATING RANGE AND CAPACITY (100 PSI).
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Engineering
Issued 3 June 1987
Resolved
RENEW B-110/24V POWER SUPPLY FOR THE ANNUNCIATOR (ALARMS) TO THE AUTOMA- TION CENTRAL CONSOLE.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Engineering
Issued 3 June 1987
Resolved
RENEW INOPERATIVE CIRCUIT BOARDS TO SOUND ALARMS AND DEMONSTRATE PROPER OPERATION. REESTABLISH VITAL AND NON-VITAL ALARMS.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Electrical
Issued 3 June 1987
Resolved
REPAIR AUTOMATIC STARTING ON STANDBY DIESEL GENERATOR AS DESCRIBED IN THE AUTOMATION PROCEDURE.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Electrical
Issued 3 June 1987
Resolved
CLEAN INTERIOR AND ASSOCIATED COMPONENTS WITHIN THE MAIN SWITCHBOARD.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Engineering
Issued 3 June 1987
Resolved
INSTALL ACTUATOR ASSEMBLY FOR DISCHARGE VALVE TO MAIN CIRCULATION PUMP.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987