Records from 1985 to 2011. Most recent: inspection, 12 October 2011.
Inspection history · 54
12 October 2011
Annual Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4167345
30 June 2011
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4063911
16 November 2010
MTSA Verification · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3890065
10 February 2010
Annual Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3681552
7 September 2009
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3588304
5 February 2009
Annual Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3403831
8 October 2008
Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3335696
19 February 2008
MTSA Verification · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3144085
11 December 2007
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3113684
5 January 2007
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2850583
20 November 2006
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2825525
12 September 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2776338
12 September 2006
Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2781291
21 November 2005
COI Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2535671
20 June 2005
MTSA Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2396687
7 March 2005
Annual Inspection · Cargo Tank Internal
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2350662
24 September 2004
Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2210079
11 March 2004
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2022475
27 October 2003
Internal Structural Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1932687
10 April 2003
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1771623
21 April 2002
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1608867
21 November 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 482338
8 November 2001
Hull Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1462279
15 December 2000
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1439125
16 March 2000
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1048189
20 January 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 472710
13 January 2000
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1393311
21 December 1998
Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1424675
10 February 1998
Re-Inspection · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1428898
18 December 1996
Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1095673
30 July 1996
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 492292
4 January 1996
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1186552
18 December 1995
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 882304
15 November 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 875976
2 November 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1422592
26 October 1995
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1184497
19 January 1995
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1190015
24 September 1994
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1454144
9 April 1992
Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 949026
24 January 1992
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 956681
18 December 1991
Permit to Proceed
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1262325
2 January 1991
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 907115
29 August 1990
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1229619
28 March 1990
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 905368
23 January 1990
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 917161
6 November 1989
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1228593
15 March 1989
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 894378
18 January 1989
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1200770
15 January 1988
MARPOL Annex II Examination · Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1014522
25 February 1987
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1320817
29 January 1987
COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1320319
24 January 1986
Deficiency Check
Physical examination · THE UNKNOWN UNIT · Activity 1304527
30 December 1985
Re-Inspection
Physical examination · THE UNKNOWN UNIT · Activity 1296029
11 January 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1286421
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 12 October 2011
No resolution recorded
# 4 stbd insert bottom shell @ frame 26 (spiget pacth found during ISE) due next Dry- Dock 2014
Action required: 705 - Other - as specified
Construction/Loadline › Hull › Hull Plating
Issued 12 October 2011
No resolution recorded
descale stren rake repalce Ladder due to wastege, repace K bracket center support left side of ladder Due next Dry-Dock
Action required: 705 - Other - as specified
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 October 2011
No resolution recorded
Cradle for bottle tank at frame 17 & 18 buckled at bottom, reweld ladder stbd side due next dry-dock
Action required: 705 - Other - as specified
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 21 July 2009
Resolved
-Per 33 CFR 155.1040(a), the Areas of Operation List must be amended to reflect the addition of the Great Lakes COTP zones.
-Per 33 CFR 155.1040(j), the geographic-specific appendix for each COTP zone must include notifications to the appropriate state authorities, including boundary states.
Due 21 August 2009
Resolved 14 December 2009
Resolution: VRP for TMI-101 does not authorize Great Lakes COTP zones.
Construction/Loadline › Hull › Side Shell
Issued 8 October 2008
Resolved
Crop and renew corner knuckle on starboard side in bow rake by the end of drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 March 2009
Resolution: 16ft of the knuckle was replaced
Construction/Loadline › Hull › Longitudinal Frame
Issued 8 October 2008
Resolved
Crop and renew #1 & #2 side long in way of frame 5 & 6 in the #1 port void by the end of drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 March 2009
Resolution: Side longs renewed
Construction/Loadline › Hull › Hull Plating
Issued 8 October 2008
Resolved
Crop and renew hull plating on the top knuckle were clad weld is present in the #1 void prior to the end of drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 March 2009
Resolution: The plating was renewed
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 October 2008
Resolved
Crop and renew bulkhead 16 & 23 in way of buckled areas along the side shell in the # 3 port void by the end of drydock.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 25 March 2009
Resolution: The bulkheads were renewed
Construction/Loadline › Hull › Hull Plating
Issued 8 October 2008
Resolved
Crop and renew top knuckle were clad welding is present in the #3 port void by the end of drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 March 2009
Resolution: The knuckle plate was renewed
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 October 2008
Resolved
Crop and renew frames 18, 20, & 22 in the #3 port void by the end of drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 March 2009
Resolution: Frames renewed
Construction/Loadline › Hull › Transverse Frame
Issued 8 October 2008
Resolved
Repair frame 19 in the #3 port void by the end of drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 March 2009
Resolution: Frame was renewed
Construction/Loadline › Hull › Side Shell
Issued 8 October 2008
Resolved
Remove backing plate on the top knuckle in way of frame 28 in the #4 port void. Make ready for inspection/repair. Complete before the end of drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 March 2009
Resolution: The knuckle was repaired
Construction/Loadline › Structures › Deck Plating
Issued 8 October 2008
Resolved
Remove the backing plate over the insert in the overhead center of stern rake and make ready for inspection. Due by drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 April 2009
Resolution: The overhead plating was renewed
Construction/Loadline › Hull › Stiffener
Issued 8 October 2008
Resolved
Repair the cracked stiffners as marked in the cargo containment tank by the end of drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 March 2009
Resolution: Stiffners were repaired
Construction/Loadline › Hull › Hull Plating
Issued 8 October 2008
Resolved
Crop and renew the wasted area around the insert in the bottom aft starboard side of the cargo containement tank by the end of drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 March 2009
Resolution: The plate was replaced
Construction/Loadline › Hull › Stringer
Issued 8 October 2008
Resolved
Crop and renew wasted metal on the forward tank cradle port and starboard side in the cargo containment tank by the end of drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 March 2009
Resolution: The cradle was repaired
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 October 2008
Resolved
Crop and renew forward bulkhead in way of buckled areas areas along the side shell in the #1 starboard void by the end of drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 March 2009
Resolution: The bulkhead was renewed
Construction/Loadline › Hull › Weld
Issued 8 October 2008
Resolved
Gouge and properly weld cracked weld on frame 6 in the #1 starboard void by the end of drydock.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 25 March 2009
Resolution: The frame was replaced
Stability › Watertight Integrity › General
Issued 8 October 2008
Resolved
Gauge and provide belt gauging report to the Coast Guard. Due at drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 March 2009
Resolution: Gauging report provided. All belts were found sat
Operations/Management › Streamlined Inspection Program › CAP Review and Revision
Issued 8 October 2008
Resolved
Survey vessel and provide comprehensive side shell and frame replacement proposal by drydock.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 February 2009
Resolution: Proposal was provided
Construction/Loadline › Hull › Weld
Issued 21 November 2006
Resolved
Fractured weld in fwd rake in way of frame #1 and 1st underdeck long from port side shell.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 February 2007
Resolved 27 November 2006
Resolution: Fractured weld repaired.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 November 2006
Resolved
Aft bulkhead in bow rake wasted in way of 4th vertical stiffner from the stbd sideshell near upper deck.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 November 2006
Resolution: Wasted area cropped and renewed w/insert.
Stability › Watertight Integrity › General
Issued 21 November 2006
Resolved
Access hatch to the fwd rake is wasted.
Condition: Unknown
Due 21 February 2007
Resolved 27 December 2006
Resolution: Witnessed proper repair/replacement of access hatch.
Construction/Loadline › Hull › Weld
Issued 21 November 2006
Resolved
Fractured welds in stbd void in way of 1st sideshell long from bottom and frames 10 and 12.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 February 2007
Resolved 27 November 2006
Resolution: Fractured welds repaired.
Construction/Loadline › Hull › Transverse Frame
Issued 21 November 2006
Resolved
Frames 4 and 10 wasted away inboard from port and stbd sideshell. Correct during next drydock.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 March 2009
Resolution: Frames are replaced.
Construction/Loadline › Hull › Weld
Issued 21 November 2006
Resolved
Fractured weld on frame 27 in way of 6th bottom long from port bulkhead. Correct at next drydock.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 March 2009
Resolution: Fractured is repaired
Construction/Loadline › Hull › Longitudinal Frame
Issued 21 November 2006
Resolved
Frame 28 wasted in way of 3rd bottom long from port bulkhead. Correct at next drydock.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 March 2009
Resolution: Frame is replaced
Construction/Loadline › Hull › Side Shell
Issued 21 November 2006
Resolved
Doubler found in #2 port void between frame 9 and 10. Correct at next drydock.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 March 2009
Resolution: Doubler was removed and the hull plate was replaced
Stability › Watertight Integrity › General
Issued 21 November 2006
Resolved
Gaskets on all void access hatches are wasted.
Condition: Unknown
Due 31 December 2006
Resolved 27 December 2006
Resolution: Verified new gaskets placed in access hatches to voids.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 21 November 2006
Resolved
RPM gauge on cargo pump is not operational.
Condition: Unknown
Due 31 December 2006
Resolved 27 December 2006
Resolution: Witnessed proper operation of RPM Gauge on cargo pump.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 21 November 2006
Resolved
Aft ladder to cargo pump area is wasted.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 December 2006
Resolved 27 November 2006
Resolution: New ladder placed on vessel.
Construction/Loadline › Hull › Longitudinal Frame
Issued 21 November 2006
Resolved
The aft 18" of the 3rd sideshell long from the bottom in the aft void wasted. Repair at next drydock.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 March 2009
Resolution: Side long is repaired
Construction/Loadline › Hull › Weld
Issued 21 November 2006
Resolved
Fractured welds in the way of 4th and 5th sideshell longs from the bottom, at the aft portion of the long.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 February 2007
Resolved 27 November 2006
Resolution: Fractured welds repaired.
Construction/Loadline › Hull › Weld
Issued 21 November 2006
Resolved
Fractured welds in 6th sideshell long from the bottom in way of starboard sideshell, at aft portion of the long.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 February 2007
Resolved 27 November 2006
Resolution: Fractured welds repaired.
Construction/Loadline › Hull › Hull Plating
Issued 21 November 2006
Resolved
Voids not completely descaled for inspection. Descale all void spaces as necessary prior to next ISE.
Action required: 705 - Other - as specified
Resolved 21 October 2008
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 21 November 2006
Resolved
Aft emergency shutdown pull not operating properly.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 December 2006
Resolved 27 November 2006
Resolution: Emergency shutdown repaired/made operational.
Construction/Loadline › Hull › Hull Plating
Issued 12 September 2006
Resolved
Vessel has fractured hull plate in starboard bow rake corner wrapper.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2006
Resolution: Welded fracture in Starboard Bow Rake Wrapper.
Construction/Loadline › Hull › Hull Plating
Issued 12 September 2006
Resolved
Vessel hit concrete railroad bridge and sustained damage to starboard bow. Unable to determine extent of damage from exterior, required all void on the forward half of the vessel to be gas freed for futher examination.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2006
Resolution: Vessel attended by [name withheld] to conduct internal examination, [name withheld] issued another CG-835 to make permanent repairs to fracture in Starboard Bow Rake corner wrapper.
Engineering
Issued 13 January 2000
Resolved
PROVIDE A TACHOMETER (RPM INDICATOR) FOR THE GMC 6-71 CARGO PUMP DIESEL ENGINE.
Condition: Unknown
Due 13 January 2000
Resolved 13 January 2000
Fire Fighting
Issued 10 February 1998
Resolved
Portable extinguisher mounted on the stern cargo tank bulkhead, originally part of the cargo pump emergency shutdown, is out of service and disconnected from the system. Required to remove emergency shutdown sign and the extinguisher by 10MAR98.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Deck/Cargo
Issued 2 November 1995
Resolved
RENEW BALL IN FORWARD CARGO TANK VENT.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Navigation
Issued 2 January 1991
Resolved
RELOCATE HAZARDOUS CARGO LIGHT AND AMBER PUSHING AHEAD LIGHT OUTSIDE OF THEHAZARDOUS LOCATION ZONE, A MINIMUM OF TEN (10) FEET FROM CARGO TANK VENTS, ULLAGE OPENINGS, FLANGES OR CONNECTIONS.
Condition: Unknown
Due 2 January 1991
Resolved 2 January 1991
Construction/Loadline
Issued 23 January 1990
Resolved
RENEW BADLY WORN MOORING CLEAT LOCATED AT CENTERLINE ON STERN.
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Electrical
Issued 23 January 1990
Resolved
RENEW ELECTRICAL JUNCTION BOXES FOR NAVIGATION LIGHTS LOCATED AT DECK HOUSEPORT SIDE FORWARD.
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Construction/Loadline
Issued 23 January 1990
Resolved
VEE AND WELD CRACKED WELDS AND INTERNAL FRAMING AS MARKED AND DISCUSSED WITH OWNER'S REPRESENTATIVE.
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Deck/Cargo
Issued 23 January 1990
Resolved
REPAIR LEAKING PIPE FITTING ON THE CARGO RETURN LINE IN THE PORT CARGO TANK VOID SPACE.
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Construction/Loadline
Issued 23 January 1990
Resolved
DRILL STOP, VEE AND WELD CRACKS IN MAIN DECK AND SIDE SHELL PLATING AT THE SHEAR KNUCKLE AS MARKED AND DISCUSSED WITH OWNER'S REPRESENTATIVE.
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Deck/Cargo
Issued 6 November 1989
Resolved
PROVIDE THE INFORMATION REQUIRED BY 46 CFR 54.01-5(C)(3) FOR NEW PRESSURE VESSEL OR REMOVE.
Condition: Unknown
Due 6 November 1989
Resolved 6 November 1989
Construction/Loadline
Issued 18 January 1989
Resolved
REPAIR 3"X1/2" HOLE IN MAIN DECK AT FORWARD,STBD CORNER OF TANK HOUSING. INSERT TO APROX 10"X15"
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Deck/Cargo
Issued 18 January 1989
Resolved
TEST OPERATION OF PUMP ENGINE AND EMERGENCY SHUTDOWN.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Deck/Cargo
Issued 18 January 1989
Resolved
REPLACE 2 BOLTS IN ULLAGE OPENING FLAME SCREEN.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Construction/Loadline
Issued 18 January 1989
Resolved
REPLACE SECURING DOG ON VOID ACCESS ON FORWARD,PORT CORNER OF TANKTOP.
Condition: Unknown
Due 18 January 1989
Resolved 18 January 1989
Deck/Cargo
Issued 29 January 1987
Resolved
CONDUCT A HYDROSTATIC TEST OF ALL CARGO HOSES TO 225 PSI.
Condition: Unknown
Due 29 January 1987
Resolved 29 January 1987
Construction/Loadline
Issued 30 December 1985
Resolved
REPAIR FRACTURE IN STERN AT STARBOARD CORNER.
Condition: Unknown
Due 30 December 1985
Resolved 30 December 1985
Deck/Cargo
Issued 30 December 1985
Resolved
REPLACE FLAME SCREEN IN CARGO PUMP ENGINE DIESEL FUEL TANK VENT.
Condition: Unknown
Due 30 December 1985
Resolved 30 December 1985
Deck/Cargo
Issued 30 December 1985
Resolved
REPLACE FLAME SCREEN IN NUMBER 1 CARGO TANK GOOSENECK VENT.
Condition: Unknown
Due 30 December 1985
Resolved 30 December 1985
Construction/Loadline
Issued 30 December 1985
Resolved
REPAIR FRACTURE IN GUNWALE AT NUMBER 2 STARBOARD CARGO TANK.
Condition: Unknown
Due 30 December 1985
Resolved 30 December 1985