Records from 1994 to 2025. Most recent: inspection, 1 August 2025.
Inspection history · 34
1 August 2025
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8200164
23 September 2024
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8007694
12 July 2023
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7723973
19 July 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7510713
19 July 2021
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7238575
1 April 2021
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7173343
20 July 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7011472
15 April 2020
Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6939464
11 July 2019
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6848456
1 July 2019
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6732152
29 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6526299
16 July 2018
Initial Certification · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6481046
14 March 2018
Industry Initiated Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6371562
27 June 2012
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4412452
23 January 2012
Industry Initiated Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4229803
9 May 2011
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4020516
7 November 2006
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2816345
2 November 2006
Administrative Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2813082
14 September 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2778094
12 September 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2776338
12 September 2006
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2777520
21 June 2005
MTSA Verification · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2398139
21 April 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2339878
23 October 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979725
29 June 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 191711
29 June 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 771090
21 July 1998
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 102510
10 October 1997
Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 773891
7 May 1997
MARPOL Annex I Examination · MARPOL Annex V Examination · Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1099840
29 April 1996
MARPOL Annex V Examination · MARPOL Annex I Examination · Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1082386
16 May 1995
Uninspected Towing Vessel · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1234156
6 April 1995
MARPOL Annex I Examination · MARPOL Annex V Examination · Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 875350
28 October 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 101891
25 June 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 23193
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 September 2024
Resolved
Each lifebouy on a towing vessel must: Be approved under approval series 160.050 or 160.150.
Port and starboard lifebouys retroreflective tape is faded. Renew/repalce.
Action required: 10 - Deficiency Rectified
Due 27 September 2024
Resolved 8 November 2024
Resolution: Vessel replaced life ring bouys with new retro
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 September 2024
Resolved
Paints, coatings, or other flammable or combustible products onbaord a towing vessel must be stored in a designated storage room or cabinet when not in use.
There is a coffee can with oil in it under the bridge steering console, and excessive oil containers stored in the engine room. Remove or properly store. Correct within 7 days.
Action required: 10 - Deficiency Rectified
Due 27 September 2024
Resolved 8 November 2024
Resolution: All products were removed from eng room
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 July 2022
Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of § 141.370 for specified areas where the vessel operates (3 day and 3 night). Vessel is missing three night flares. Restricted to day operations.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 26 July 2022
Resolution: Recieved Flares
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 July 2022
Resolved
Flexible connections and discharge hoses on all semi-portable extinguishers and fixed extinguishing systems must be inspected and tested in accordance with § 147.65 of this chapter. The cone/nozzle on the semi-portable extinguisher is cracked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 26 July 2022
Resolution: O/O replaced Horn on holes
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 19 July 2022
Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. The navigation assessment must incorporate the requirements of pilothouse resource management of § 140.640, assess operational risks, and anticipate and manage workload demands. Navigational assessments were not being conducted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 26 July 2022
Resolution: O/O recieved the Assessmnet
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 July 2022
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure storage areas are kept free from accumulation of combustible and flammable materials insofar as practicable. Oily rags were stored in plastic bucket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 26 July 2022
Resolution: Vessel recieved new oily rag cans
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 July 2022
Resolved
The following systems must be equipped with gauges at the machinery location:
(1) Main engine lubricating oil pressure and main engine RPM;
(2) Main engine cooling water temperature;
(3) Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM;
(4) Auxiliary generator engine cooling water temperature
Missing gauges on all main engines.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 30 August 2022
Resolution: O/O installed Tach
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 7 October 2021
Resolved
Towing vessels must meet the requirements of 33CFRpart 26, both DSC radios on bridge did not have MMIS stored. Installed MMIS
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2021
Resolved 7 October 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 October 2021
Resolved
Each towing vessel must be equipped with a means to detect smoke in berthing spaces. Vessel did not have smoke detection
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2021
Resolved 7 October 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 July 2020
Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light under the approval series 161.010 or 161.110. Attach approved water lights to ring buoys.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2020
Resolved 28 July 2020
Resolution: Vessel rep sent pictures showing approved water lights have been installed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 July 2020
Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370. Vessel is required to have 3 floating orange smoke signals for the route.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2020
Resolved 21 July 2020
Resolution: Vessel sent pictures of 3 floating orange smoke distress signals.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 July 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and shock hazards. A shield needs to be installed to cover battery charger exposed electrical hazards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2020
Resolved 20 July 2020
Resolution: Corrected on the spot. Added plexiglass cover.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 July 2020
Resolved
Each lifejacket must be fitted with Type I retro-reflective material. Replace worn retro-reflective tape on lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2020
Resolved 28 July 2020
Resolution: Vessel sent pictures showing newly replaced retro-reflective tape on lifejackets.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 29 August 2018
Resolved
NAME: Vsl is broadcasting incorrect Name(Abbreviation), ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 3 December 2018
Resolution: def cleared
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 7 November 2006
Resolved
1. Collectors of urine specimens were not qualified as per 49 CFR Part 40. 2. Persons conducting screening tests did not have required training as per 46 CFR Part 4.
Due 2 December 2006
Resolved 22 January 2007
Resolution: Company will not have in house urine collectors. Persons designated to conduct screening test for alcohol were given required training with testing device.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 7 November 2006
Resolved
Drug Testing Program policy must be revised to include reasons for testing as per 46 CFR Part 16.
Due 2 December 2006
Resolved 22 January 2007
Resolution: Drug Testign Program policy updated to reflect reasons for testing as per 46 CFR Part 16.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 7 November 2006
Resolved
EAP material must be displayed as per 46 CFR 16.401.
Due 2 December 2006
Resolved 22 January 2007
Resolution: Unit DAPI Coordinator visited company site and confirmed compliance of EAP requirements.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 7 November 2006
Resolved
MIS report must be submitted annually to G-MOA by March 15.
Due 2 December 2006
Resolved 22 January 2007
Resolution: Company was provided with a copy of MIS report form and has been given training by unit DAPI Coordinator of how to complete and when to submit. Company representative is fully aware of responsibility to submit report by March 15th of every year.
Operations/Management › Drug and Alcohol Testing › MRO Specified
Issued 7 November 2006
Resolved
MRO not specified in Drug Testing Policy.
Due 2 December 2006
Resolved 22 January 2007
Resolution: Drug Testing Policy updated with MRO information.
Unknown
Issued 6 April 1995
Resolved
Vessel Name on Tug must be spelled the same as on the Document.
Condition: Unknown
Due 20 April 1995
Resolved 2 June 1995
Unknown
Issued 6 April 1995
Resolved
mark official number clearly on interior structure (frame)
Condition: Unknown
Due 20 April 1995
Resolved 2 June 1995
Lifesaving
Issued 6 April 1995
Resolved
Lifering needs reflective tape placed at four equal spaces on both sides.
Condition: Unknown
Due 20 April 1995
Resolved 2 June 1995
Navigation
Issued 6 April 1995
Resolved
Replace Green (STBD) sidelight lens, and install two (02) 225 degree white masthead towing lights.
Condition: Unknown
Due 20 April 1995
Resolved 2 June 1995
Accommodation/Occupational Safety
Issued 6 April 1995
Resolved
remove toilet from vessel untill approved MSD installed.
Condition: Unknown
Due 20 April 1995
Resolved 2 June 1995
Electrical
Issued 6 April 1995
Resolved
replace globe on Port side aft deck light.
Condition: Unknown
Due 20 April 1995
Resolved 2 June 1995
Lifesaving
Issued 6 April 1995
Resolved
Provide one CG approved Type 1 PFD per crewmember
Condition: Unknown
Due 20 April 1995
Resolved 2 June 1995