Inspection history · 40
22 May 2025
Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8141642
17 April 2024
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7888639
23 May 2023
Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7694570
23 August 2022
Periodic Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7541763
11 August 2021
Drydock Exam · Cargo Tank Internal · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7301087
2 July 2020
Annual Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7004728
23 April 2019
COI Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6662918
3 April 2018
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6384024
9 May 2017
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6134697
29 April 2016
Internal Structural Exam · Deficiency Check · Administrative Inspection · Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5865058
30 March 2015
Administrative Inspection · MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5093188
14 April 2014
Administrative Inspection · Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4836001
25 October 2013
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4741389
18 August 2012
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4417823
12 April 2012
MTSA Verification · Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4261959
1 November 2011
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4180185
8 September 2011
DAPI Audit
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4139990
9 April 2010
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3712991
10 June 2009
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3500157
27 April 2009
COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3453682
3 December 2008
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3373753
29 April 2008
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3195321
10 April 2008
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3181485
7 March 2008
Internal Structural Exam · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3160397
2 March 2007
MTSA Verification · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2880841
7 December 2006
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2835853
4 December 2006
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2833764
14 November 2006
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2821580
11 May 2006
Administrative Inspection · In-Service Inspection · MTSA Verification · Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2612971
11 May 2005
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2351219
3 May 2005
Annual Inspection · MTSA Verification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2334553
11 January 2005
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2272753
11 January 2005
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2272778
23 April 2004
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2051212
17 October 2003
Administrative Inspection
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1930528
9 July 2003
Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1840985
29 May 2002
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1625313
15 October 2001
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 491019
7 September 2001
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1071308
4 June 2001
Hull Examination · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1376619
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2024
Resolved
All electrical installations in hazardous locations must comply with the general requirements of section 33 of IEEE 45-1998 and with either article 500-505 of NFPA NEC2002 or with the IEC 60079 series. Vessel has electrical heating wrap installed that does not meet construction standards for a Class 1, Division 1 hazardous location. Heating wrap was removed and corrected before leaving the vessel.
46 CFR 111.105-3
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 17 April 2024
Resolved 17 April 2024
Resolution: Removed before departing the vessel
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 August 2022
Resolved
Your vessel must undergo a periodic inspection within 3 months before or after the second or third anniversary of the date of your vessel's Certificate of Inspection. This periodic inspection will take the place of an annual inspection. The vessel did not complete a periodic inspection within the specified time. Vessel is restricted from movement and cargo operations until a periodic inspection is completed satisfactory to an attending marine inspector. Inspection was completed prior to departing the vessel and deficiency was corrected on the spot.
46 CFR 31.10-17(b)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 23 August 2022
Resolved 23 August 2022
Resolution: Periodic inspection was completed.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 May 2016
Resolved
Power supply wire connection to lighting fixture loose, exposing internal wiring to chaffing and potentially a circiut short/shock hazard. Required proper connection IAW 46CFR183.340.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2016
Resolved 5 May 2016
Resolution: Lighting wire properly connected to fixture.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 2 May 2016
Resolved
Vessel's COFR, required by 33 CFR 138.140 expired 31MAR2016. Vessel owner/operator required to provide evidence of financial responsibility as required by 33 CFR 138 Subpart A prior to operating.
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 3 May 2016
Resolution: New COFR with expiration date of 03MAY2016 issued by NPFC.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 6 May 2015
Resolved
Two junction boxs each had one opening which was open and not properly plugged. Unsupervised openings on electrical enclosures result in potential elecrical hazards to the vessel and crew.
Action required: 705 - Other - as specified
Resolved 8 May 2015
Resolution: Openings were properly plugged.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 6 May 2015
Resolved
All required portable fire extinguishers were on board during inspection, however, unapproved mounting bracket used at one station.
Action required: 705 - Other - as specified
Resolved 8 May 2015
Resolution: Approved mounting bracket installed.
Engineering › Pressure Vessel › Relief Valve
Issued 24 April 2014
Resolved
Vessel's service air receiver had two pressure relief valves that were not tested.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2014
Resolved 15 May 2014
Resolution: Received email verification from O/O that relief valves were tested to operate w/ 10% of MAWP. O/O was previously unaware of manual operation capability of compressor system and was therefore unable to test point at which relief valves opened.
Communications › Visual Communication › Warning Sign (gangway)
Issued 27 April 2009
Resolved
Properly install warning sign as required (46 CFR 35.30-1)
Action required: 705 - Other - as specified
Due 2 May 2009
Resolved 29 April 2011
Resolution: Noted warning signs were properly installed.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 21 October 2008
Resolved
-The VRP must be amended to state that training regimens apply to the qualified and alternate qualified individuals, and members of the spill management team per Reg 33 CFR 155.1055
-The geographic-specific appendices in the VRP must be amended to align with the 33 CFR Part 3 technical amendments to reflect the introduction of Sector Commands
Due 21 November 2008
Resolved 16 December 2008
Resolution: Deficiencies fixed with revision submitted 12/4/08. Vessel approved for resubmission. Vessel expiration date 12/23/2013 (VRP #00154)
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 21 October 2008
Resolved
-Per Reg 33 CFR 155.1040(k), the barge-specific appendices must be amended to include the individual capacities of all ballast tanks.
Due 21 November 2008
Resolved 16 December 2008
Resolution: Deficiencies fixed with revision submitted 12/4/08. Vessel approved for resubmission. Vessel expiration date 12/23/2013 (VRP #00154)
Engineering › Fuel Oil Service System › Hose
Issued 10 April 2008
Resolved
Flex hose used on engine for barge generator not SAE J-1942 rated.
Action required: 705 - Other - as specified
Due 10 May 2008
Resolved 29 April 2008
Resolution: New metalic flex hose purchased and installed.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 10 April 2008
Resolved
No deck covering.
Action required: 705 - Other - as specified
Due 10 May 2008
Resolved 29 April 2008
Resolution: New mats purchased and installed.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 10 April 2008
Resolved
Records missing for last test (March 08) of pressure gage and relief valve.
Action required: 705 - Other - as specified
Due 10 May 2008
Resolved 29 April 2008
Resolution: Proper documentation for tests provided.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 8 March 2007
Resolved
Dog on S1 cargo tank hatch inoperable AND all void hatches were unable to open to allow for inspection of hatch covers, gaskets, and voids from deck level.
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 13 March 2007
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 8 March 2007
Resolved
Below deck cargo valve indicators inoperable on 2S & suction valves.
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 13 March 2007
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 2 March 2007
Resolved
Door on distribution panel for shore power tie missing.
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 12 April 2007
Resolution: Panel door required fabrication; verified installation with vessel rep.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 25 May 2006
Resolved
Lack of insulation on exhaust for diesel engine used to power generator.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 June 2006
Resolved 7 June 2006
Resolution: Insulation installed.
Deck/Cargo › Cargo Stowage › General
Issued 25 May 2006
Resolved
Independent deck tank designated for carriage of gasoline missing PV vent.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2006
Resolved 7 June 2006
Resolution: PV vent installed.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 3 May 2005
Resolved
Properly paint vessels name and home port on stern in a contrasting color.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2005
Resolved 3 May 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Loading Arms
Issued 3 May 2005
Resolved
Conduct annual weight test on vessels hydraulic deck crane.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2005
Resolved 11 May 2005
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 3 May 2005
Resolved
Properly clean all lube oil storage tank flame screens.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2005
Resolved 11 May 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 3 May 2005
Resolved
Provide proper documentation of hydro-testing on vessels cargo transfer hoses. (missing test psi)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 May 2005
Resolved 11 May 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Bolts
Issued 3 May 2005
Resolved
Properly install missing flange bolt from the port side, bottom valve, slop oil tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2005
Resolved 11 May 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 3 May 2005
Resolved
Properly renew or replace worn oil transfer hose marked F4.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2005
Resolved 11 May 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 23 April 2004
Resolved
Prove proper operation test of cargo piping relief valve. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 29 May 2004
Resolved 28 April 2004
Documentation › Logs/Records
Issued 23 April 2004
Resolved
Provide proper documentation of piping and cargo hose hydro testing. LEGACY COMPONENT DESC: HYDRO Cargo System Testing
Due 29 May 2004
Resolved 28 April 2004
Documentation
Issued 4 June 2001
Resolved
PROVIDE MSO ST.LOUIS DRAFT MARKINGS OF BARGE WHEN ALL CARGO, LUBE AND WATERTANKS ARE LOADED.
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001