Inspection record

Last inspected 26 May 2026
…with no type recorded11
Operational controls None recorded without a removal date
Years with a record 25 calendar years (2001–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
393 - Simplified, Gross Ton 393 - Simplified, Net Ton
Maury page id
psix-24595
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 14

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

MT AIRY Towing Vessel · MISLE 219897 · 9 March 2015 · activity 5081033MT AIRY Towing Vessel · MISLE 219897 · 18 February 2015 · activity 5073466CUMBERLAND HUNTER Towing Vessel · MISLE 71081 · 30 October 2014 · activity 5018360RIVER TITAN Towing Vessel · MISLE 125862 · 17 August 2012 · activity 4466133GD 949 Freight Barge · MISLE 407975 · 17 August 2012 · activity 4466133GD 958 Freight Barge · MISLE 416158 · 17 August 2012 · activity 4466133GD 961 Freight Barge · MISLE 419005 · 17 August 2012 · activity 4466133GD975 Freight Barge · MISLE 460179 · 17 August 2012 · activity 4466133BBL 713 Freight Barge · MISLE 876716 · 17 August 2012 · activity 4466133MGI-F2 Tank Barge · MISLE 45683 · 5 February 2005 · activity 2287485MGI-F6 Tank Barge · MISLE 511083 · 23 November 2004 · activity 2246734CUMBERLAND HUNTER Towing Vessel · MISLE 71081 · 15 November 2004 · activity 2242953MGI-F6 Tank Barge · MISLE 511083 · 8 November 2004 · activity 2245920C.J. QUEENAN Towing Vessel · MISLE 97476 · 13 December 2002 · activity 1740233DM 1234 Freight Barge · MISLE 369307 · 13 December 2002 · activity 1740233E.W. THOMPSON Towing Vessel · MISLE 510474 · 13 December 2002 · activity 1740233BRUCE D Towing Vessel · MISLE 117922 · 21 February 2002 · activity 1492019

Inspection history · 43

26 May 2026 Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8375839
22 May 2025 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8141605
17 April 2024 Periodic Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7896868
23 May 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7694559
18 November 2022 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7596743
28 October 2020 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7086086
24 September 2019 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6819826
10 October 2018 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6560234
10 July 2017 Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6204238
30 September 2016 Annual Inspection · MTSA Verification · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6013013
15 July 2015 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5190086
9 March 2015 Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5081033
18 February 2015 Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5073466
30 October 2014 Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5018360
7 August 2014 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4975426
10 July 2014 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4917208
17 December 2013 Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4770738
17 September 2013 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4685057
17 August 2012 Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4466133
4 July 2012 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4367100
29 June 2011 Hull Examination · Periodic Inspection · Administrative Inspection · Cargo Tank Internal · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4061872
9 August 2010 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3820174
21 July 2009 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3541385
3 December 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3373691
18 July 2008 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3271959
18 July 2007 COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2998275
19 July 2006 Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2718141
5 July 2006 Internal Structural Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2695033
14 October 2005 Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2514608
5 February 2005 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2287485
11 January 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2272745
11 January 2005 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2272776
23 November 2004 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2246734
15 November 2004 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2242953
8 November 2004 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2245920
16 July 2003 Annual Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1848148
16 December 2002 Damage Survey
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1721061
13 December 2002 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1740233
23 July 2002 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1650900
22 February 2002 Examination of Repairs · Damage Survey
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1488481
21 February 2002 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1492019
7 September 2001 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1071295
5 July 2001 COI Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1471775

Deficiency record · 40

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 May 2025 Resolved
All electrical installations in hazardous locations must comply with the general requirements of section 33 of IEEE 45-1998 and with either article 500-505 of NFPA NEC2002 or with the IEC 60079 series. Wiring for bow navigational lights does not meet construction standards for a Class 1, Division 1 hazardous location. Repair/remove to the satisfaction of an attending Marine Inspector. 46 CFR 111.105-3
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 10 June 2025
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 22 May 2025 Resolved
Each hose assembly used for transferring oil or hazardous material must meet the following requirements. Vessel has numerous non-metallic transfer hoses that are not properly labeled; missing markings "FOR OIL SERVICE" and date of last hydrostatic test, in accordance with 33 CFR 156.170. Provide required labeling or remove hoses to the satisfaction of an attending Marine Inspector. 33 CFR 155.800 33 CFR 154.500
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 10 June 2025
09 - Working and Living Conditions › 092 - Working Conditions › Loading and unloading equipment
Issued 22 May 2025 Resolved
The registers issued in connection with cargo gear certification must have all required entries fully completed as of dates indicated, shall be kept current, and shall include the following: certification of the testing and examination of cranes. Crane certification expired. Certify crane with approved organization, in accordance with 46 CFR 31.10-16(e)(1) and (2). 46 CFR 31.10-16(d)(3)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 10 June 2025
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 22 May 2025 Resolved
Any tank vessel which is equipped with an internal combustion engine driven cargo pump on the weather-deck shall be provided with a minimum of one remote manual shutdown station. Remote shut down pull cable did not shut down engine. Repaired on the spot. 46 CFR 32.50-35(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2025
Resolution: Repaired on the spot
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 22 May 2025 Resolved
A mechanical means of closing each drain and scupper within the coaming. Vessel was missing 4 coaming scupper plugs. Repaired on the spot. 33 CFR 155.310(d)(2)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2025
Resolution: Repaired on the spot
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 May 2025 Resolved
The owner, master or person-in-charge of a tank vessel must ensure that portable and semi-portable extinguishers are inspected and maintained in accordance with NFPA 10. Installed extinguishers have no proof servicing. repaired on the spot. 46 CFR 31.10-18(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2025
Resolution: Repaired on the spot
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 23 May 2023 Resolved
Sounding pipes shall be kept closed at all times except during sounding. Male cam lock cap was improperly being used on a threaded sounding pipe for the independent gasoline tank. Install threaded cap to the satisfaction of an attending Marine Inspector. 46 CFR 56.50-75(g)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 20 June 2023
Resolution: Installed correct cap.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 23 May 2023 Resolved
Hazardous location equipment must be approved as suitable for use in the specific hazardous atmosphere in which it is installed. Inboard lighting lens outside the generator room has a broken lens inside a hazardous location. Replace lens to the satisfaction of an attending Marine Inspector. 46 CFR 111.105-5
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 20 June 2023
Resolution: Lens replaced
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 23 May 2023 Resolved
Hazardous location equipment must be approved as suitable for use in the specific hazardous atmosphere in which it is installed. Power supply junction box for gasoline pump has exposed wiring in a hazardous location. Repair to the satisfaction of an attending Marine Inspector. 46 CFR 111.105-5
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 20 June 2023
Resolution: Repaired wiring
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 23 May 2023 Resolved
Gears, couplings, flywheels and all machinery capable of injuring personnel shall be provided with adequate covers or guards. Coupling for potable water pump and electric motor did not have a guard installed. Install machinery guard to the satisfaction of an attending Marine Inspector. 46 CFR 58.01-25
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 20 June 2023
Resolution: Guard installed
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 23 May 2023 Resolved
Each nonrising-stem valve, lever-operated valve, or other valve where, because of design, the position of the disc or closure mechanism is not obvious must be fitted with an indicator to show whether the valve is opened or closed. Several cargo tank suction line valves are not equipped with valve position indicators. Install valve indicator in accordance with 46 CFR 56.50-1(g)(2)(iii) and to the satisfaction of an attending Marine Inspector. 46 CFR 56.20-9(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 20 June 2023
Resolution: Indicators installed
Construction/Loadline › Structures › Deck Plating
Issued 15 July 2015 Resolved
Deck fittings on stern badly worn and in need of replacement
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2015
Resolved 30 September 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 July 2014 Resolved
Electrical conduit protecting electrical supply lines to water pump broken through.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 July 2014
Resolved 11 July 2014
Electrical › Electrical Distribution System (service) › Junction Box
Issued 10 July 2014 Resolved
Heat tape installation on cargo lines not installed IAW Sub J. Remove or bring to code.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 July 2014
Resolved 11 July 2014
Resolution: removed.
Engineering › Compressed Air System (start air) › Compressor
Issued 10 July 2014 Resolved
Air compressor installed in location prohibited by 46 CFR 32.35-15
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 August 2014
Resolved 7 August 2014
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 10 July 2014 Resolved
Cargo transfer hose test report not marked with test pressure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2014
Resolved 11 July 2014
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 July 2011 Resolved
The Drydock, ISE and cargo tank internals are expired.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2011
Resolution: Drydock and CTI completed.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 22 July 2011 Resolved
Water tight cover for outlet box was missing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2011
Resolution: Replaced on the spot
Engineering › Fuel Oil Service System › Hose
Issued 22 July 2011 Resolved
Fuel line was leaking.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2011
Resolution: Corrected on the spot
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 22 July 2011 Resolved
Gasket was wasted
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2011
Resolution: Corrected on the spot.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 21 October 2008 Resolved
-The VRP must be amended to state that training regimens apply to the qualified and alternate qualified individuals, and members of the spill management team per Reg 33 CFR 155.1055 -The geographic-specific appendices in the VRP must be amended to align with the 33 CFR Part 3 technical amendments to reflect the introduction of Sector Commands.
Due 21 November 2008
Resolved 16 December 2008
Resolution: Deficiencies fixed with revision submitted 12/4/08. Vessel approved for resubmission. Vessel expiration date 12/23/2013 (VRP #00154)
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 21 October 2008 Resolved
-Per Reg 33 CFR 155.1040(k), the barge-specific appendices must be amended to include the individual capacities of all ballast tanks.
Due 21 November 2008
Resolved 16 December 2008
Resolution: Deficiencies fixed with revision submitted 12/4/08. Vessel approved for resubmission. Vessel expiration date 12/23/2013 (VRP #00154)
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 July 2007 Resolved
Vessel failed to conduct an Annual Inspection between the period 23APR06-23OCT06.
Action required: 705 - Other - as specified
Due 18 July 2007
Resolved 18 July 2007
Construction/Loadline › Hull › Weld
Issued 5 July 2006 Resolved
VEE AND RE-WELD ALL MARKED BROKEN WELDS AT THE TOP OF EACH VERTICAL BUCK FRAME AT THE SIDESHELL INTERFACE IN WAY OF #2 STARBOARD VOID.
Action required: 705 - Other - as specified
Due 5 August 2006
Resolved 19 July 2006
Construction/Loadline › Hull › Weld
Issued 5 July 2006 Resolved
VEE AND RE-WELD THE BROKEN WELDS ON THE TOP OF THE 2ND AND 3RD VERTICAL BUCK FRAME AT THE SIDE SHELL INTERFACE IN WAY OF #3 STARBOARD VOID.
Action required: 705 - Other - as specified
Due 5 August 2006
Resolved 19 July 2006
Construction/Loadline › Hull › Weld
Issued 5 July 2006 Resolved
VEE AND RE-WELD ALL BROKEN WELDS AT THE TOP OF EACH VERTICAL BUCK FRAME AT THE SIDESHELL INTERFACE IN WAY OF #4 STARBOARD VOID.
Action required: 705 - Other - as specified
Due 5 August 2006
Resolved 19 July 2006
Construction/Loadline › Hull › Weld
Issued 5 July 2006 Resolved
VEE AND RE-WELD THE BROKEN WELDS AT THE TOP OF THE 1ST AND 3RD VERTICAL BUCK FRAME AT THE SIDESHELL INTERFACE, AS WELL AS RENEWING THE 3 BENT BRACKETS AT THE FORWARD BULKHEAD/SIDESHELL INTERFACE, AND REWELD THE FIRST WEB FRAME BROKEN AT THE SIDESHELL INTERFACE ALL IN WAY OF #1 PORT VOID.
Action required: 705 - Other - as specified
Due 5 August 2006
Resolved 19 July 2006
Construction/Loadline › Hull › Weld
Issued 5 July 2006 Resolved
VEE AND RE-WELD THE BROKEN WELDS AT THE TOPS OF EACH VERTICAL BUCK FRAME AT THE SIDESHELL INTERFACE IN WAY OF #2 PORT VOID.
Action required: 705 - Other - as specified
Due 5 August 2006
Resolved 19 July 2006
Construction/Loadline › Hull › Weld
Issued 5 July 2006 Resolved
VEE AND RE-WELD ALL BROKEN WELDS AT THE TOP OF EACH VERTICAL BUCK FRAME AND BOTTOM OF #2 BUCK FRAME. CROP AND RENEW THE 2ND SIDESHELL LONGITUDINAL FRAME AFT WHERE BROKEN AS WELL AS THE TOP AFT 2 CORNER BRACKETS AT THE AFT BULKHEAD SIDESHELL INTERFACE ALL IN WAY OF #3 PORT VOID.
Action required: 705 - Other - as specified
Due 5 August 2006
Resolved 19 July 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 October 2005 Resolved
Replace lifeline on both lifebuoys.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 November 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 14 October 2005 Resolved
Re-stencil Emergency Shutdown placards.
Action required: 705 - Other - as specified
Resolved 2 November 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 14 October 2005 Resolved
Replace cargo hose F-8.
Action required: 705 - Other - as specified
Resolved 2 November 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 October 2005 Resolved
Repair Amber flashing light.
Action required: 705 - Other - as specified
Resolved 2 November 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 14 October 2005 Resolved
Replace gas filling hose.
Action required: 705 - Other - as specified
Resolved 2 November 2005
Construction/Loadline › Hull › Hull Plating
Issued 16 December 2002 Resolved
Sustained damage while mooring. A mooring pin on the port corner, at the deck knuckle, approximately 13" inboard of the side shell. The damage was an approximately 9" crack. The vessel is not to load until repairs are made to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 December 2002
Resolved 19 December 2002
Resolution: Witnessed air test to insert used to effect repairs, air test was satisfactory. Inspection complete, the vessel is fit for route and service.
Electrical › Electrical Distribution System (service)
Issued 23 July 2002 Resolved
Place non-conductive mats on deck in vicinity of electrical panels. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Condition: Unknown
Due 6 August 2002
Resolved 6 August 2002
Resolution: Non-conductive mats on deck.
Accommodation/Occupational Safety › Occupational Safety
Issued 23 July 2002 Resolved
Install protective guard over generator diesel engine drive belt and pulleys. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Improper Installation
Due 6 August 2002
Resolved 6 August 2002
Resolution: Protective guard in place.
Deck/Cargo › Cargo Stowage
Issued 23 July 2002 Resolved
Block, brace or secure all oil drums. LEGACY COMPONENT DESC: drums
Condition: Improper Installation
Due 6 August 2002
Resolved 6 August 2002
Resolution: Drums lashed together.
Deck/Cargo › Holds/Tanks
Issued 23 July 2002 Resolved
Install P/V valve on deck gasoline cargo tank. LEGACY COMPONENT DESC: Valve, Pressure Vacuum Relief
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2002
Resolved 6 August 2002
Resolution: Bronze P/V in place.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 22 February 2002 Resolved
Make permanent repairs to the fractured plating on #1 starboard lube oil deck tank to the statisfaction of attending Coast Guard marine inspector.
Condition: Damaged By Earlier Event
Due 22 March 2002
Resolved 4 March 2002
Resolution: Examined permanent repairs and witnessed satisfactory air test of #1 stbd lube oil tank.