MAURY USCG vessel records Sign in
← All vessels

PETRA

PETRA is a 1985 freight ship. The Coast Guard has recorded 92 inspections since 1985, most recently in February 2016, along with 40 deficiencies and 9 operational controls.

Records from 1985 to 2016. Most recent: inspection, 9 February 2016.

Built
1985
Last inspected
9 February 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8412986 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
251777
Flag
JAPAN
—
Maury page id
psix-251777

Inspections, by type

…with no type recorded56
Years with a record 28 calendar years (1985–2016)
The 92 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it44356 - Convention (Subpart B), Gross Ton
44356 - Simplified, Gross Ton
13306 - Simplified, Net Ton
13306 - Convention (Subpart B), Net Ton
28586 - Displacement, Ton
17624 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest. Towing vessels are barely present in the record before 1992, so tow-unit membership for activities older than that is recorded only partially.

LILY ANNE Towing Vessel · MISLE 204160 · 3 April 2003 · activity 1768057NICHOLAS M Freight Ship · MISLE 225279 · 3 April 2003 · activity 1768057SUN STATE 902 Freight Barge · MISLE 42371 · 18 November 1991 · activity 59179MISS OCIE Towing Vessel · MISLE 71496 · 18 November 1991 · activity 59179

Inspection history · 92

9 February 2016 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5811905
26 January 2016 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5795046
4 December 2015 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5771227
15 October 2015 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5757089
22 August 2015 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5223031
21 August 2015 ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5221817
20 August 2015 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5222081
17 August 2015 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5219145
30 May 2014 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4874434
29 May 2014 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4872991
26 March 2009 MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3440584
21 October 2008 Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS III Exam · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3348694
23 August 2008 ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3306312
14 June 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3236605
22 March 2008 Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3169128
14 January 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3130245
2 December 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3108117
2 November 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3092029
27 July 2007 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3008813
6 July 2007 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2983918
8 February 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2869074
12 October 2006 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2799060
11 September 2006 MARPOL Annex V Examination · MARPOL Annex I Examination · Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2775313
11 July 2006 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2709669
1 June 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2667144
31 May 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2666549
15 January 2006 Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2567306
12 January 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2565804
6 June 2005 PII Safety Exam · ISPS III Exam · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2377780
20 April 2005 Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2339008
15 March 2005 Random ISPS/MTSA/PSC
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2310285
15 November 2004 MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2240771
4 October 2004 ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2212620
5 August 2004 ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2156523
21 June 2004 PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2101536
27 October 2003 Ballast Water Examination · Passenger/Freight Vessel Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1936627
13 June 2003 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1816365
12 June 2003 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1815757
3 April 2003 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1768057
30 March 2003 Ballast Water Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1760766
28 October 2002 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1696979
7 September 2002 Ballast Water Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1672165
22 July 2002 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1650378
5 June 2002 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1626652
4 June 2002 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1625959
4 June 2002 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1626859
14 April 2002 Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1604525
10 April 2002 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1605594
21 February 2002 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1488252
28 December 2001 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1474219
13 August 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 292723
27 April 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 289454
12 September 2000 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 282080
11 August 2000 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 280918
7 April 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 276457
10 September 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 432709
12 July 1999 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 430315
16 February 1999 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 425170
31 July 1998 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 418588
10 June 1998 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 417164
21 October 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 408952
30 June 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 405109
17 November 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 397577
1 May 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 390591
15 December 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 484803
12 October 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 384135
17 June 1995 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 379321
28 March 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 376704
6 December 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 676848
18 November 1994 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 454531
19 October 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 371616
16 May 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 676845
11 May 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 366737
21 January 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 499613
8 May 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 358185
4 November 1992 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 442092
3 May 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 480046
19 November 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 540296
18 November 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 59179
9 April 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 343202
12 July 1990 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 473218
14 January 1990 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 337186
2 July 1989 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 503137
28 January 1989 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 328216
5 December 1988 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 327113
26 February 1988 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 455245
19 August 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 317981
2 March 1987 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 539787
18 August 1986 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 310611
26 February 1986 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 307260
24 February 1986 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 509234
22 July 1985 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 303267

Deficiency record · 40

Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 26 January 2016 Resolved
In all ships, fire extinguishing appliances shall be kept in good order and availiable for immediate use at all times during the voyage. CO2 is leaking into refrigerant system causing refrigeration to shut off. Teachnician is currently onboard facilitating repairs. CO2 system is currently inoperable. 74 SOLAS (81 AMMENDED) II-2/21
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 January 2016
Resolved 2 February 2016
Resolution: Received class and technician report attest to repairs and proper operation of the vessel fixed low pressure CO2 firefighting system. See attached class and technician report.
Fire Fighting › Portable Foam Applicators › General
Issued 4 December 2015 Resolved
01 - 0720 - Fire Fighting Equipment - Each Ro/Ro cargo space intended for the carriage of motor vehicles with fuel in their tanks for their own propulsion shall be provided with at least three water fog applicators and one portable foam applicator unit. Vessel had no portable foam applicator unit or water fog applicators in Ro/Ro cargo space. See MISLE narrative for rest of def.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 December 2015
Resolved 2 February 2016
Resolution: Received class report attest to the proper placement of the required water mist and foam applicators. See attached class report.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 4 December 2015 Resolved
02 - 1030 - Steering gear alarm - Any main steering gear control system operable from the bridge shall in the event of a failure of electrical power supply to the control system, an audible and visual alarm shall be given on the bridge. No audible or visual alarm sounded on the bridge for loss of power. 74 SOLAS (81 Amen) Chapt II-1 Reg 29.8
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 December 2015
Resolved 2 February 2016
Resolution: Received class report attest to the proper operation of the audio and visual alarms located on the bridge for the steering gear as required. See attached class report.
Operations/Management › Vessel Activity › Construction/Repair
Issued 4 December 2015 Resolved
03 - 1400- Propulsion and Aux Machinery: Machinery piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. The ballast pump and summered use ref. cool sw pump were leaking excessively. 74 SOLAS (81) Chapt II-1 reg 26.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 December 2015
Resolved 2 February 2016
Resolution: Received class report attest to the proper operation of the audio and visual alarm for the steering gear located on the bridge. See attached class report.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 4 December 2015 Resolved
04 - 0999 - Other (Safety in general) - Electrical installations shall be such that the safety of the crew and ship from electrical hazards will be ensured. Temporary lighting was installed over generators and throughout the eng. room. 74 SOLAS (81 Amen) Chapt II-1 Reg 40 1.3
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 December 2015
Resolved 2 February 2016
Resolution: Received class report attest to the removal of the temoprary light locate over the survice generators. See attached class report.
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 26 March 2009 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2009
Resolution: VESSEL PROVIDED PROOF FROM FLAG STATE OF ENDORSEMENT.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 6 July 2007 Resolved
The low pressure CO2 pipe outside the paint locker has been patched. All records on board indicate that this system is in good condition. No reports of any kind have been submitted to the Company or Class. Ref. SOLAS IX/3.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2007
Resolved 23 July 2007
Resolution: Repairs have been made by the crew under the direction and guidance of the Classification Society Representative.
Construction/Loadline › Structures › Door
Issued 6 July 2007 Resolved
All accommodation doors are not water or weather tight. Silicone has been added by the crew around all the doors. Holes have been covered with tape and painted over by the crew. No reports of any kind have been submitted to the Company or Class. Ref. SOLAS IX/3.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2007
Resolved 23 July 2007
Resolution: Repairs have been made by the crew under the direction and guidance of the Classification Society Representative.
Deck/Cargo › Ballast › Vents
Issued 6 July 2007 Resolved
Fore peak ballast vent float wasted and will not seat correctly. No reports of any kind have been submitted to the Company or Class. Ref. SOLAS IX/3.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2007
Resolved 23 July 2007
Resolution: Repairs have been made by the crew under the direction and guidance of the Classification Society Representative.
Lifesaving › Lifeboat › Hull
Issued 6 July 2007 Resolved
The watertight storage lockers in both lifeboats are holed allowing water to enter. In addition the 3rd inboard canopy bracket on the port lifeboat has been patched with bondo. Also the seat for the mast on the port lifeboat is dry rotted. All reports on board indicate that all items are in good condition. No reports of any kind have been submitted to the Company or Class. Ref. SOLAS IX/3.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2007
Resolved 23 July 2007
Resolution: Repairs have been made by the crew under the direction and guidance of the Classification Society Representative.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 6 July 2007 Resolved
The SOLAS Training Manual is not ship specific. There are a number of items which do not apply to this vessel. The crew needs to update this and add to it items which are ship specific.
Action required: 705 - Other - as specified
Due 6 August 2007
Resolved 23 July 2007
Resolution: Repairs have been made by the crew under the direction and guidance of the Classification Society Representative.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 6 July 2007 Resolved
The Ballast Plan does not include a form for documentation of sediment. In addition training for the crew as per section 7, is not being carried out by the Master or [name withheld].
Action required: 705 - Other - as specified
Due 6 August 2007
Resolved 14 July 2007
Resolution: The Master conducted crew training and documented same.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 6 July 2007 Resolved
The crew has been burning oily rags and paper in the incinerator. However none of the [name withheld] have not been recording this in the Garbage Log. No recordings have been made since September 2006. Company and Class need to address this.
Action required: 705 - Other - as specified
Due 6 August 2007
Resolved 23 July 2007
Resolution: Company representative conducted MARPOL and proper documentation training with the Master, [name withheld] and Chief Engineer.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 6 July 2007 Resolved
Mixed garbage was found in all of the containers throughout the vessel. Even at the final collection point which is located on the port side upper deck. We relayed to the Master that the crew needs more training regarding garbage control and the [name withheld] who is in charge needs to be more involved.
Action required: 705 - Other - as specified
Due 6 August 2007
Resolved 23 July 2007
Resolution: A Company Representative conducted
Engineering › Steering Gear System › Hand Pump
Issued 6 July 2007 Resolved
The steering unit reservoir was low and had to be refilled by the crew. In case of an emergency it would have taken a considerable amount of time to refill the unit.
Action required: 705 - Other - as specified
Due 6 July 2007
Resolved 6 July 2007
Resolution: The crew refilled the unit prior to us leaving.
Fire Fighting › Emergency Fire Pumps › Location
Issued 6 July 2007 Resolved
The insulation on the bulkheads has been removed by the crew and needs to be re-attached to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 6 August 2007
Resolved 23 July 2007
Resolution: Repairs have been made by the crew and was inspected and accepted by the Classification Society Representative.
Deck/Cargo › Cargo Stowage › General
Issued 6 July 2007 Resolved
The decks for the cars are loose and numerous tack welds attaching the deck to the frames are cracked. The crew has been repairing these on a regular basis. The company is aware of the on-going problems but they have failed to notify Class. Class needs to inspect and approve the welding repairs and the welders.
Action required: 705 - Other - as specified
Due 6 August 2007
Resolved 23 July 2007
Resolution: Repairs have been accepted by the Classification Society Representative. The crew has been authorized by Class to continue repairing the decks during long voyages.
Personnel › Manning/Qualifications › First Aid Certified Personnel
Issued 6 July 2007 Resolved
The 3rd Officer was designated as the Medical Officer. During our inspection all of the Deck Officers were in doubt if they met the STCW regs. A-VI/4-2 for Medical. Reviewing their certificates the C/O held the required STCW endorsement. However, it has been well over 5yrs since he served as a Medical Officer and he was unsure of what he was required to do. The Company needs to look into this.
Action required: 705 - Other - as specified
Due 6 August 2007
Resolved 23 July 2007
Resolution: The Flag State Representative has addressed this. According to the Flag State requirements the Master or [name withheld] must have the proper training and be designated as the medical officer.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 September 2006 Resolved
OWS panel replaced at most recent shipyayrd/drydock period. Alarm shows 15 PPM in the engine control room, but only sounds audible at 01 PPM in the engine room spaces. This is a wiring problem from the shipyard period. Form B was to have repaired prior to next US Port arrival. Vessel going to
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 4 November 2006
Resolved 12 October 2006
Resolution: 12 OCT 06 - As per class report (NKK), Alarm for 15ppm sensor of OWS was repaired and the performance test was carried out with satisfactory result.
Personnel › Certificates/Documents/Licenses
Issued 12 June 2003 Resolved
1st assistant engineer's Panamanian endorsement found missing for his Korean licnese # BS-E1-02-0429. Endorsement must be provided to COTP NY prior to vessel departing the port. LEGACY COMPONENT DESC: License, Assistant Engineer
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 12 June 2003
Resolved 13 June 2003
Resolution: Documentation from PM consulate recieved via fax this date approving individuals license. COTP removed this date as well.
Lifesaving › Lifeboat
Issued 7 September 2002 Resolved
Starboard lifeboat fwd bracing block wasted. Replace to the satisfaction of the class society surveyor.
Action required: 705 - Other - as specified
Due 7 October 2002
Resolved 27 October 2002
Resolution: Corrected
Lifesaving › Launching Appliances
Issued 7 September 2002 Resolved
Class society surveyor to attest to the condition of all sheaves on port and stbd lifeboats. Stbd lifeboat aft lower outer sheave and fwd inside outer plate sheave is worn. Port lifeboat aft lower inside plate on outer sheave thin. Recommend replacement or repairs. LEGACY COMPONENT DESC: Davit
Action required: 705 - Other - as specified
Due 7 October 2002
Resolved 27 October 2002
Resolution: Corrected
Lifesaving › Lifeboat
Issued 7 September 2002 Resolved
Class society surveyor to attest to the condition of stbd lifeboat where outer handrail is attached on bottom (aft). Possible leak where attached. LEGACY COMPONENT DESC: Handholds/Handrails
Action required: 705 - Other - as specified
Due 7 October 2002
Resolved 27 October 2002
Resolution: Corrected
Deck/Cargo › Cargo Stowage
Issued 7 September 2002 Resolved
Class surveyor to attest to repairs done to Cargo Deck 09 between frames 90- 110 at top of entry frame.
Action required: 705 - Other - as specified
Due 7 October 2002
Resolved 27 October 2002
Resolution: Corrected
Construction/Loadline › Structures
Issued 22 July 2002 Resolved
Several Cracks in Deck Grating noted on Number 6, 7, 8, decks. Required Classification survey to be sent to COTP LA-LB prior to next U.S. Port. Classification Society required to check all cargo decks for structural integrity and vsl to make repairs to the satisfaction of the Class Surveyor. LEGACY COMPONENT DESC: Deck Plating
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 10 August 2002
Resolution: Classification report rcv''d 10 Aug 2002 by MSO LALB. Class report stated over 200 cracks either temp. or permanetly repaired. See Special Notes for info.
Fire Fighting › Firemans Outfit
Issued 4 June 2002 Resolved
Fireman's heat reflective gloves on for both sets of fireman's suits badly worn. Material is flaking off and gloves are not suitable for firefighting. LEGACY COMPONENT DESC: Gloves
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 22 July 2002
Resolution: Purchased new Firefighting Gloves.
Fire Fighting › Firemans Outfit
Issued 14 April 2002 Resolved
One of the Firemans Outfit reflective material is failing off. Provide a fire suit that protects the skin from the heat radiating from the fire and from burns and scalsing by steam. Fix prior to next U.S. port after sailing foreign. SOLAS 74 amd II-2/17 LEGACY COMPONENT DESC: Protective Clothing
Action required: 15 - Rectify deficiencies by next port
Resolved 4 June 2002
Resolution: Replaced fireman''s outfit with new suit.
Electrical › Electrical Distribution System (service)
Issued 21 February 2002 Resolved
Light at port bunkering station is spliced in two areas on power cord. Repair or replace light fixture wiring. LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Due 28 February 2002
Resolved 22 February 2002
Resolution: Vessel master provided faxed letter stating that the spliced wire on the port bunkering station light had been replaced.
Fire Fighting › Fire Hoses
Issued 21 February 2002 Resolved
Identified seven fire hoses with dry rotted lining/gasket material causing hoses to leak significantly in several areas. Replace fire hoses by 28 Feb 02 LEGACY COMPONENT DESC: Condition
Condition: Unknown
Due 28 February 2002
Resolved 22 February 2002
Resolution: Vessel Master provided receipt for the purchase of 8 (65 mm diameter X 30 m length) fire hoses on 22FEB02.
Construction/Loadline
Issued 11 August 2000 Resolved
Load line markings not visible. Repair/ renew provide class report prior to11 sep. 00
Condition: Unknown
Due 12 September 2000
Resolved 12 September 2000
Construction/Loadline
Issued 11 August 2000 Resolved
#6 deck at elevator flap non tight doors frame and bulkhead cracked. Repair/renew provide class report prior to 11 sept.00.
Condition: Unknown
Due 12 September 2000
Resolved 12 September 2000
Engineering
Issued 11 August 2000 Resolved
Soft patch on salt water discharge recirculation line. Have class address prior to 11 sept.00.
Condition: Unknown
Due 12 September 2000
Resolved 12 September 2000
Construction/Loadline
Issued 11 August 2000 Resolved
Cracked bracket from longitudinal frame to foward bulkhead. Repair/renew provide class report prior to 11 sept.00
Condition: Unknown
Due 12 September 2000
Resolved 12 September 2000
Engineering
Issued 12 July 1999 Resolved
REPAIR/RENEW SOFT PATCHES ON MDE SALT WATER COOLING LINES. PROVIDE CLASS REPORT PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 11 September 1999
Resolved 11 September 1999
Fire Fighting
Issued 10 June 1998 Resolved
INTERNATIONAL SHORE CONNECTION NOT LISTED ON FIRE PLAN. ADD SYMBOL/LOCATIONTO ALL FIRE PLANS ON BOARD.
Condition: Unknown
Due 31 July 1998
Resolved 31 July 1998
Electrical
Issued 30 June 1997 Resolved
Switchboard in switchboard room does not have nonconductive matting in front. Provide nonconducting matting.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Lifesaving
Issued 12 October 1995 Resolved
THE VESSEL'S PORT AND STARBOARD BRIDGE MAN OVERBOARD LIFERINGS WERE UNABLE TO BE READILY DEPLOYED. VESSEL IS REQUIRED TO CORRECT THIS DISCREPANCY PRIOR TO ENTERING ITS NEXT U.S. PORT.
Condition: Unknown
Due 4 May 1996
Resolved 4 May 1996
Engineering
Issued 11 May 1994 Resolved
THE DECLARATION OF INSPECTION FILLED OUT PRIOR TO THE BUNKERING OPERATION STATES THAT VERBAL COMMUNICATION WILL TAKE PLACE BETWEEN THE TANKERMAN AND THE VESSEL'S P.I.C. THE P.I.C WAS NOT AVAILABLE AND DID NOT FOLLOW THE D.O.I.
Condition: Unknown
Due 13 May 1994
Resolved 13 May 1994
Engineering
Issued 11 May 1994 Resolved
DURING BUNKERING OPERATIONS, THE PERSON IN CHARGE ON THE VESSEL WAS NOT AVAILABLE
Condition: Unknown
Due 13 May 1994
Resolved 13 May 1994
Unknown
Issued 5 December 1988 Resolved
33 CFR 164.25 THE PERSON RESPONSIBLE FOR THE MOVEMENT OF THE VESSEL DID NOT LOG IN THE VESSEL'S BRIDGE LOG THE TESTS REQUIRED TO ENTER A U.S. PORT.
Condition: Unknown
Due 5 December 1988
Resolved 5 December 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.