Records from 1991 to 2025. Most recent: inspection, 4 June 2025.
Documentation record
Registered dimensions (L × B × D)76.5 ft × 26.2 ft × 11.7 ft
Registered tonnagegross 197 / net 134
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderST CHARLES STEEL WORKS INC · THIBODAUX, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it197 - Regulatory (Subpart C or D), Gross Ton
134 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 49
4 June 2025
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8152143
17 April 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8113295
18 March 2025
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8096462
10 September 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8000107
21 August 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7985929
13 June 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7933807
1 August 2023
Damage Survey · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7757504
30 January 2020
Re-Inspection · Initial Certification · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6904770
19 September 2018
In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6543942
17 September 2018
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6564702
17 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6514757
16 August 2017
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6242552
19 May 2016
Industry Initiated Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5881242
21 April 2016
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5859377
28 March 2016
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5841941
8 February 2015
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5065981
5 June 2014
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4881103
30 June 2013
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4638190
11 April 2013
Industry Initiated Exam · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4567887
5 December 2012
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4497253
23 September 2012
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4449553
7 May 2012
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4313159
15 December 2011
Type not recorded
No type recorded · USCGC CAPSTAN (WYTL 65601) · USCG East District (CGD-E) · Activity 4222821
1 October 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4167027
26 August 2010
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3838528
6 August 2010
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3826003
24 March 2010
Industry Initiated Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3703296
20 June 2009
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3511951
18 May 2009
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3478071
23 February 2009
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3423096
4 December 2006
MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2837826
10 September 2005
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2496889
3 February 2004
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2012036
21 January 2004
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2013467
23 May 2003
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1799680
17 May 2003
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1797294
5 May 2003
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1786878
22 April 2003
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1778251
3 April 2003
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1768057
3 April 2003
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1810212
12 June 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1629992
11 June 2002
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1629466
11 June 2002
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1629475
20 November 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 118483
23 October 2001
Uninspected Towing Vessel
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1073970
29 October 1999
Uninspected Towing Vessel
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1129569
30 October 1997
Uninspected Towing Vessel
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 780845
16 January 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 139673
14 September 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 439955
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2025
Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with one or more spring-loaded relief valves. The total relieving capacity of such relief valves must prevent pressure from exceeding the MAWP, as established by the manufacturer, by more than 10 percent. The manufacturer listed MAWP rating for the two pressure vessels located in the engine room were labeled at 200 psi. The pressure relief valves located on the tanks were rated at 225 psi. Renew both pressure relief valves to the correct rating.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2025
Resolved 31 March 2025
Resolution: 200 psi pressure relief valves placed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2025
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Remove all daisy chained surge protectors under the pilothouse console.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2025
Resolved 2 April 2025
Resolution: surge protectors removed.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 18 March 2025
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Alarms must be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm. The required machinery alarms were not present in the upper operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2025
Resolved 17 April 2025
Resolution: Received and reviewed objective evidence of proper operation of summary alarm on upper operating station.
05 - Radio Communications › N/A - No Subsystem › SART/AIS-SART
Issued 19 September 2018
Resolved
AIS information was incorrect.
Action required: 10 - Deficiency Rectified
Due 19 September 2018
Resolved 19 September 2018
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 September 2018
Resolved
Smoke detector in accommodation space was not operational
Action required: 10 - Deficiency Rectified
Due 19 September 2018
Resolved 19 September 2018
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 19 September 2018
Resolved
Sewage overboard discharge valve was open and not locked. Vessel did not have a sewage holding tank.
Action required: 10 - Deficiency Rectified
Due 19 September 2018
Resolved 19 September 2018
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 17 August 2018
Resolved
The vessel is currently broadcasting (1) Improper MMSI Number, (2) Improper Call Sign, (3) Zero Draft.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 September 2018
Resolved 6 March 2019
Resolution: Owner reported AIS discrepancies corrected. Used NAVCEN to verify accuracy of vessel's AIS broadcast.