Records from 2009 to 2026. Most recent: inspection, 9 April 2026.
Documentation record
Registered dimensions (L × B × D)94.8 ft × 34.0 ft × 14.3 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)94.8 ft × 34.0 ft × 14.3 ft
ITC tonnagegross 327 / net 98
BuilderTHOMA-SEA BOAT BUILDERS INC · HOUMA, LA, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBALTIMORE, MD
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Net Ton
98 - Convention (Subpart B), Net Ton
98 - Regulatory (Subpart C or D), Gross Ton
327 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
9 April 2026
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8345221
10 September 2025
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8219119
31 March 2025
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8102615
5 August 2024
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7974540
4 July 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7732353
4 July 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7733449
3 March 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7644914
2 February 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7389504
27 August 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7298042
11 June 2021
COI Inspection · Initial Certification · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7222113
26 August 2014
Industry Initiated Exam · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4965791
31 October 2012
Administration
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4475823
20 August 2012
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4416753
15 August 2012
Examination of Repairs · Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4412460
14 August 2012
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4411274
6 July 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4374287
1 October 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4167027
10 August 2011
Industry Initiated Exam · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4113225
15 August 2010
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3828123
9 February 2010
Type not recorded
No type recorded · USCGC CLEAT (WYTL 65615) · USCG East District (CGD-E) · Activity 3677675
26 January 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3672219
21 January 2010
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3670584
20 January 2010
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3667236
14 December 2009
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3651854
14 November 2009
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3634033
26 May 2009
Uninspected Other
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3486431
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 April 2026
Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. While the ITV was preparing to moor with barge, the ITV made contact on starboard quarter with pier and facility appendages. ITV is awaiting instructions from company to moor at pier and have TSMS ABS on-board to conduct a damage survey. ITV is not to engage in commercial operations until ABS determines the seaworthiness of ITV and to attest ITV did not receive any damage and no repairs necessary.
Company shall provide a damage survey attending to the watertight integrity and stability of the vessel prior to cargo operations to the satisfaction of ABS.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 10 April 2026
Resolution: Cleared to satisfaction of attending ABS, CG reviewed ABS Survey report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 August 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel reported a loss of power on both the port and starboard generators due to unknown causes. The vessel is required to be towed back to Philadelphia, PA and make permanent repairs to the satisfaction of the TPO.
Action required: 705 - Other - as specified
Resolved 6 August 2024
Resolution: See TPO report in documents
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 July 2023
Resolved
Vessel reported loss of power/propulsion. Vessel to remain at Vane Brother's Brooklyn until a damage survey has been completed and necessary repairs completed to the satisfaction of USCG Marine Inspector/TSMS Surveyor.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 August 2023
Resolution: ABS attended the damage survey at the request of owner. A preliminary report for the vessel was provided. All Sat.
14 November 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3634033
20 January 2010Routine · role: Involved in a Marine Casualty · activity 3667236
15 August 2010Routine · role: Involved in a Marine Casualty · activity 3828123
6 July 2012Routine · role: Involved in a Marine Casualty · activity 4374287
20 August 2012Routine · role: Involved in a Marine Casualty · activity 4416753
27 August 2021Routine · role: Involved in a Marine Casualty · activity 7298042
4 July 2023Routine · role: Involved in a Marine Casualty · activity 7733449
31 March 2025Routine · role: Involved in a Marine Casualty · activity 8102615
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source:
IIR, through 2026.