Records from 2015 to 2025. Most recent: inspection, 20 October 2025.
Documentation record
Registered dimensions (L × B × D)348.0 ft × 62.0 ft × 24.5 ft
Registered tonnagegross 4,311 / net 2,505
ITC dimensions (L × B × D)348.0 ft × 62.0 ft × 24.5 ft
ITC tonnagegross 4,311 / net 2,505
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2015
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBALTIMORE, MD
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4311 - Convention (Subpart B), Gross Ton
2505 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
20 October 2025
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8251462
21 August 2025
Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8214776
13 November 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8033780
20 September 2023
Periodic Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7795033
4 July 2023
Administrative Inspection · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7732358
4 July 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7733449
31 May 2023
Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7701436
8 November 2022
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7591183
11 September 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7556858
4 January 2022
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7387760
17 September 2020
Internal Structural Exam · COI Inspection · Deficiency Check · Drydock Exam · Cargo Tank Internal
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7059171
21 August 2020
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7038887
7 October 2019
Annual Inspection · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6829507
18 December 2018
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6599435
16 September 2018
MTSA Verification · Internal Structural Exam · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6541533
27 June 2017
Annual Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6188051
27 January 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6079378
6 December 2016
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6054782
5 December 2016
MARPOL Annex I Examination · MTSA Verification · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6051681
14 September 2015
Initial Certification · Administrative Inspection · Hull Examination · Internal Structural Exam · MTSA Verification · Cargo Tank Internal
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5718039
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 20 October 2025
Resolved
Any tank vessel which is equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with a minimum of one remote manual shutdown station. Starboard cargo pump prime moved did not shutdown when remote shutdown was pulled.
705: Prior to Bunkering Cargo Operations
Action required: 705 - Other - as specified
Resolved 20 October 2025
Resolution: Verified correct operation of shutdown.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 September 2023
Resolved
The ring life buoy shall be either international orange or white in color. One of the lifebuoys appeared muddy and blocked the international orange color. Clean or replace lifebuoy to meet appropriate color requirement.
46 CFR 160.050-3(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 September 2023
Resolution: Received photographs of rectified deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2023
Resolved
Operational tests and checks of all safety and limit controls must be conducted by the person in charge at the periodic inspection to determine that the control components are functioning properly and are in satisfactory operating condition. The operation of safety controls for the thermal fluid heater on board could not be tested at the periodic inspection. Prior to operating thermal fluid heater.
Action required: 705 - Other - as specified
Resolved 6 December 2023
Resolution: Observed all safety and control limit operational tests. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2023
Resolved
The thermal fluid heater (TFH) is examined by a marine inspector at the periodic inspection to determine that the complete unit is in a satisfactory condition. The TFH could not be properly opened at the time of inspection.
Action required: 705 - Other - as specified
Resolved 6 December 2023
Resolution: Inspected the inside refractory of the thermal fluid heater satsifactorily. All sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 4 July 2023
Resolved
Barge reported grounding the damage to the bow section. Vessel to remain at Cadells until a damage survey has been completed and necessary repairs completed to the satisfaction of USCG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 July 2023
Resolution: Attending marine inspectors verified the watertight integrity and survivability of the barge, examining the internal structures of the FWD RAKE, 1 P/S and 2 P/S.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 October 2019
Resolved
Each vessel must carry lifebuoys approved under approval series 160.150 as follows: Lifebuoys must be so distributed as to be readily available on each side of the vessel. 01 Lifebuoys were found with poor reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 17 October 2019
Resolution: Vessel sent picture via email showing replaced reflective tape. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 September 2018
Resolved
pressure relief valve did not pop off before MAWP
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2018
Resolved 1 October 2018
Resolution: vessel purchased new relief valve and was tested in service.
Lifesaving › Liferaft Equipment › First-aid Kit
Issued 5 December 2016
Resolved
Life-raft servicing certificate is expired due to expired first-aid kit contained within. Provide satisfactory servicing certificate. 46 CFR 160-151-57(n)(1)(i)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2016
Resolved 6 December 2016
Resolution: Received servicing certificates for replacement life-rafts and witnessed their installation onboard the vessel.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 5 December 2016
Resolved
Ground detection for 120v distribution line is not providing active ground detection. Repair ground detection installation and certify continuous indication of circuit status.
Condition: Improper Installation
Due 20 December 2016
Resolved 21 December 2016
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 5 December 2016
Resolved
Starboard cargo pump engine emergency stop not operational. Repair emergency stop and conduct emergency stop test, to be witnessed by a CG inspector, prior to cargo pump operations.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2016
Resolved 6 December 2016
Resolution: Witnessed a satisfactory test of the emergency stop for the starboard cargo pump prime mover.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 5 December 2016
Resolved
Non-intrinsically safe, self igniting lifebouy lights found within the hazardous zone. Move lifebouy lights outside of the hazardous zone and provide any changes to the Fire Equipment and Safety Plan for OCMI approval.
Action required: 705 - Other - as specified
Due 5 January 2017
Resolved 21 December 2016
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 5 December 2016
Resolved
#1 and #2 ship service generators electronic speed control boxes are broken and hanging off the provided mounts. Replace with marine type components suitable for the intended service and ensure the proper mounting of electronic control boxes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2016
Resolved 21 December 2016
Deck/Cargo › Cargo Heating › General
Issued 5 December 2016
Resolved
Thermal fluid heater has not been visually inspected iaw 46 CFR 61.30-15 and .30-20. Repair as necessary and make the thermal fluid heater available for inspection by a Coast Guard marine inspector. The thermal fluid heater shall remain in a disabled condition and shall not be made operational without the approval of the cognizant OCMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 January 2017
Resolved 21 December 2016