SAFESEA JANAKI is a 2008 freight ship. The Coast Guard has recorded 44 inspections since 2019, most recently in October 2025, along with 22 deficiencies and 26 operational controls, 1 with no removal date recorded.

Records from 2019 to 2025. Most recent: inspection, 30 October 2025.

Built
2008
Last inspected
30 October 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Identity

9403451
3E8339
997226
Flag
PANAMA
Maury page id
psix-997226

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded26
Years with a record 7 calendar years (2019–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it9957 - Convention (Subpart B), Gross Ton
5020 - Convention (Subpart B), Net Ton
13621 - Dead Weight, Ton
18956 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 9

Inspection history · 44

30 October 2025 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8259120
8 April 2025 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8103955
18 February 2025 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8080751
28 September 2024 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8010674
10 September 2024 PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8000165
15 May 2024 Appeal
Administrative · Commandant (CG-CVC) · Activity 7936905
1 April 2024 PSC B · Deficiency Check · Appeal
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7887982
26 February 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7870643
12 January 2024 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7848681
6 December 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7834331
15 November 2023 PSC B · Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7825113
13 November 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7823972
11 October 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7806852
21 March 2023 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7652876
11 September 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7556858
8 September 2022 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7554564
6 September 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7552369
24 August 2022 PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7542292
20 August 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7538752
9 August 2022 PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7528680
5 August 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7525314
1 July 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7492301
15 June 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7478386
28 May 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7461036
26 April 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7438740
11 April 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7428849
30 March 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7421685
11 March 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7410378
21 February 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7399454
9 February 2022 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7393266
5 February 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7391299
20 January 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7383340
29 December 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7373599
24 November 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7357207
24 November 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7357213
9 November 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7348280
27 October 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7340548
10 May 2021 Ballast Water Examination · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7192152
24 March 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7161795
4 November 2020 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7089479
3 November 2020 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7086540
3 November 2020 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7111519
30 October 2020 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7087070
20 March 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6644447

Deficiency record · 22

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 September 2024 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed fuel oil leak on the number 1,2, and 3 generator. Leaks were located at the fuel oil leak detection boxes. 74SOLAS(04)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2024
Resolved 11 September 2024
Resolution: Received class report attesting to the repairs made to the fuel line pressure relief valve.
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 11 September 2024 Resolved
The endorsements shall each be assigned a unique number, matching the certificate concerned. PSCO observed incorrect number on endorsement. STCW I/2.8.3 (16 a,c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2024
Resolved 19 September 2024
Resolution: Vessel has submitted evidence that endorsement error has been corrected. This deficiency has been resolved.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 11 September 2024 Resolved
Sanitary facilities for all members of the crew who do no occupy rooms to which private or semi-private facilities attached shall be provided one water closet for every 8 persons or less. PSCO observed deck one centerline water closet inoperable. PSCO observed starboard water closet with unapproved water supply. ILO 147 crew accommodation/ para.20 PWSA46 USC 70002
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2024
Resolved 11 September 2024
Resolution: Received class report attesting to repairs made to the crew water closets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 September 2024 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed port lube oil pump leaking. 74SOLAS(02) II-1/26.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 September 2024
Resolved 11 September 2024
Resolution: Crew replaced worn seal/gasket around port lube oil pump. Class onboard, attested to repair.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 1 April 2024 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and any additional requirements which may be established by the company. In meeting these requirements, the company should ensure that: inspections are held at appropriate intervals, any non-conformity is reported, with its possible cause, if known; appropriate corrective action is taken, and records of these activities are maintained. The technical and operational nature of the deficiencies noted below provide objective evidence of a serious failure of the implementation of the ISM Code. An external audit is required prior to clearance of this deficiency. 74SOLAS(20) IX/3.1, ISM Code 10.1 & 10.2 - 30bc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 5 April 2024
Resolution: External audit was conducted with 2 NC found. Vessel sent survey and audit report upon completion.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 1 April 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects remains fit to proceed to sea without danger to the ship or persons onboard. PSCO observed active hydraulic oil leak from the port side piston ram on steering gear while conducting a steering test. 74 SOLAS (20) I/11(a) - 30bc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 5 April 2024
Resolution: According to survey report, the source of leak was identified and fixed by crew. Conducted ER steering test during def check and no active leaks were observed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 April 2024 Resolved
Means shall be provided to control leaks of flammable liquids. Active diesel and fuel oil leaks and were observed on multiple areas of the main engine. 74 SOLAS (04) II-2/2 4.1.1 - 30bc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 5 April 2024
Resolution: All pools of oil and active leaks were cleaned up. Class report identified source of active leaks to be due to work O-rings. Parts were replaced and all was observed to be in good working order during def check.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 April 2024 Resolved
All gearing of every shaft and coupling used for transmission of power to machinery essential for the propulsion and safety of the ship… shall be so designed and constructed that they will withstand the maximum working stresses to which they may be subjected in all service conditions. Main engine stern tube leaking oil at a rate of 1 drop every 10 seconds. 74SOLAS II-1/27.3 - 30bc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 5 April 2024
Resolution: Survey report identified source of leak to be the result of a worn liner in the stern tube seal. Part was replaced and area was cleaned by crew. No active leaks were observed during def check.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 April 2024 Resolved
Oil fuel pipes and their valves and fittings shall be of steel or other approved material. To control the fuel, lubrication, and hydraulic oils leaking from machinery, the crew cut out holes in metal plating, manufactured fittings, attached flexible hoses, buckets, and funnels to divert and collect leaking oil. Cite: 74 SOLAS (04) II-2/4.2.2.5.1 Action: 17bc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2024
Resolution: All plastic flexible hoses were removed according to the survey report. during def check, that was confrmed and no hoses were found.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 April 2024 Resolved
Where the contents and use of a space are such that there is doubt as to its classification for the purpose of this regulation, or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevant category having the most stringent boundary requirements. Multiple void spaces are being left open and entered by ship's crew for use of storage of paint, chemicals, spare parts, garbage and other items. Cite: 74 SOLAS (04) II-2/9.2.3.3.2.2 Action: 17bc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2024
Resolution: According to survey report, all containers of paint and flammable liquids were removed from the void spaces and relocated to proper stowage areas. PSC team checked the void spaces and confirmed findings in survey report.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 1 April 2024 Resolved
The condition of the ship and its operational equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects remains fit to proceed to sea without danger to the ship or persons onboard. An excessive water leak was observed on the lube oil plate cooler. Cite: 74 SOLAS (20) I/11(a) Action: 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 September 2024
Resolution: PSCO observed repairs during PSC B exam on 11SEP24
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 April 2024 Resolved
After any survey of the ship...has been completed, no change shall be made in the structural arrangements, machinery equipment and other items covered by the survey without the sanction of the Administration. PSCO observed a doubler plate welded onto settling tank No. 1 with oil seeping from the weld. Cite: 74 SOLAS (20) I/11(b) Action: 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 September 2024
Resolution: PSCO observed repairs during PSC B exam on 11SEP24
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 1 April 2024 Resolved
If a ship at the time when a certificate expires is not on a port in which it is to be surveyed, the Administration may extend the period of validity of the certificate but this extension shall be granted only for the purpose of allowing the ship to complete its voyage to the port in which it is to be surveyed, and then only in cases where it appears proper and reasonable to do so. Vessel was last in drydock October 2018/ two subsequent short term SOLAS Cargo Ship Safety Construction Certificates were issued from 06OCT23-26JAN24 and 01JAN24-26APR24 for the purpose of extending the drydock date. The vessel had planned voyages to the U.S. and foreign ports before attending dry dock in Mexico on 26APR24. Cite: 74 SOLAS (20) I/14(e) Action: 15ac
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 September 2024
Resolution: Amended def from a code 15ac to a code 40ac. Vessel is required to have drydock and valid full term CSSCC by next US port. PSCO observed new CSSCC and proof of drydock during PSC B exam on 11SEP24.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 December 2023 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: Means shall be provided to control leaks of flammable liquids. PSCO observed multiple instances of oil stained lagging throughout engine room. 50ac 74 SOLAS (04) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2024
Resolved 12 January 2024
Resolution: Class Report received stating "Insulation/lagging at various locations in engine room was found renewed and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 November 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 November 2023
Resolved 16 November 2023
Resolution: Submitted RO Report for surveyor attendance and rectification of deficiency
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 November 2023 Resolved
THE FOLLOWING FIRE PROTECTION SYSTEMS SHALL BE KEPT IN GOOD ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS: FIRE DETECTION SMOKE DETECTOR NEAR MAIN ENGINE WAS FOUND INOPERABLE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 November 2023
Resolved 16 November 2023
Resolution: Submitted RO Report for surveyor attendance and rectification of deficiency
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 November 2023 Resolved
FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READY FOR IMMEDIATE USE. CO2 FLEX HOSE CONNECTIONS WERE FOUND LOOSE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 November 2023
Resolved 16 November 2023
Resolution: Submitted RO Report for surveyor attendance and rectification of deficiency
14 - Pollution Prevention › 148 - Ballast Water › Ballast water logs/records
Issued 8 September 2022 Resolved
Maintain a ballast water management plan that has been developed specifically for the vessel. Vessel used white out to correct multiple wrong entries. Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 September 2022
Resolved 9 September 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 8 September 2022 Resolved
The ring lines and letters shall be painted white or yellow on dark background. Plimsoll mark is rusted over with no paint.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 September 2022
Resolved 9 September 2022
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 8 September 2022 Resolved
Before the ship leaves port and at all time during the voyage, all life-saving appliances shall be in working order and reday for immediate use. Rescue boat engine failed to start.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 September 2022
Resolved 9 September 2022
Resolution: Received Class report
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 24 August 2022 Resolved
The fire control plan shall be kept up to date; any alterations thereto shall be recorded as soon as practicable. Port State Control Examiner identified that the galley door is missing a self-closing device preventing it from operating as a self-closing door. Per the fire control plan, the galley door shall be a self-closing door.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2022
Resolution: The vessel provided a technical report of the repaired galley door to the satisfaction of the class surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 August 2022 Resolved
74 SOLAS (04) I/11(a) Code: 60ac The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. A jacket water leak was identified on the #4 main engine cylinder. This equipment is not functioning as designed and presents a danger to the ship and the crew.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 August 2022
Resolution: Replaced O-rings within the #4 main cylinder engine and tested to the satisfaction of class.