MAURY USCG vessel records Sign in
← All vessels

B. E. LINDHOLM

B. E. LINDHOLM is a 1985 industrial vessel. The Coast Guard has recorded 195 inspections since 1985, most recently in March 2024, along with 180 deficiencies, 2 operational controls and 20 casualty investigations between 2002 and 2023.

Records from 1985 to 2024. Most recent: inspection, 5 March 2024.

Built
1985
Last inspected
5 March 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8402773 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCY9878
260758
Flag
UNITED STATES
—
Maury page id
psix-260758

Inspections, by type

…with no type recorded64
Years with a record 38 calendar years (1985–2024)
The 195 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it3445 - Regulatory (Subpart C or D), Gross Ton
3498 - Convention (Subpart B), Gross Ton
3340 - Regulatory (Subpart C or D), Net Ton
1049 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCV7673MMSI not assigned · expired · compulsorily equipped · granted 19 January 1996, cancelled 25 March 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DELTA Towing Vessel · MISLE 368581 · 18 November 2015 · activity 5796671LIGHTNING Towing Vessel · MISLE 1110710 · 18 November 2015 · activity 5796671THUNDER Towing Vessel · MISLE 1158103 · 18 November 2015 · activity 5796671BAYOU CHENE Offshore Supply Vessel · MISLE 261894 · 17 December 2004 · activity 2265068STOLT ACHIEVEMENT Tank Ship · MISLE 499346 · 21 October 2002 · activity 1693845

Inspection history · 195

5 March 2024 In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7874393
18 December 2023 Examination of Repairs · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7840275
21 July 2023 Drydock Exam · In-Service Inspection · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7748261
3 April 2023 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7658578
14 March 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7650690
14 March 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7650733
18 January 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7654399
22 July 2022 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7558608
2 July 2022 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7543218
18 April 2022 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7433357
30 March 2022 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7420841
21 March 2022 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7416009
4 January 2022 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7375540
6 May 2021 Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7191553
12 April 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7173459
24 March 2021 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7162595
23 February 2021 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7144671
22 February 2021 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7152767
28 January 2021 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7132488
9 January 2021 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7123984
28 December 2020 Appeal · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7117321
2 July 2020 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6993813
11 March 2020 Bulk Solid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6925145
15 January 2020 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6887156
22 November 2019 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6861787
16 November 2019 Damage Survey · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6857807
21 August 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6790291
19 August 2019 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6789204
26 July 2019 Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6762873
10 July 2019 Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6745143
9 July 2019 Administrative Inspection · Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6743908
2 July 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6733025
1 July 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6741661
14 June 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6713733
13 June 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6713765
18 February 2019 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6641949
13 February 2019 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6625264
14 January 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6609897
14 January 2019 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6613864
11 January 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6613529
15 November 2018 Examination of Repairs · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6581376
27 October 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6575519
23 October 2018 In-Service Inspection · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6566329
7 September 2018 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6535150
3 July 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6468204
22 March 2018 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6376989
17 March 2018 Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6378558
11 March 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6459897
10 March 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6370870
6 February 2018 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6350018
25 November 2017 Administrative Inspection · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6313271
23 November 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6332048
26 October 2017 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6295567
16 March 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6108307
12 March 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6136721
10 March 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6136699
25 January 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6078573
21 November 2016 Examination of Repairs · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6045515
11 October 2016 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6020074
13 September 2016 DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6000076
11 July 2016 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5936551
11 April 2016 Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5852427
9 February 2016 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5816536
17 December 2015 Administrative Inspection · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5783729
15 December 2015 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5784035
18 November 2015 In-Service Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5766152
18 November 2015 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5796671
10 November 2015 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5760242
4 September 2015 Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5234698
4 June 2014 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4879492
23 May 2014 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4864648
5 June 2012 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4334968
15 May 2012 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4312190
4 May 2012 Examination of Repairs · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4301995
2 February 2011 Administrative Inspection · Inclining Experiment · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4088195
31 December 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3663497
23 December 2009 Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 3701078
6 July 2009 Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3525834
24 April 2009 In-Service Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3459156
29 January 2009 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3402133
28 October 2008 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3353008
10 September 2008 Damage Survey
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3327508
5 September 2008 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3320294
24 September 2007 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3065865
21 September 2007 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3064879
10 July 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2990122
9 July 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2991769
27 June 2007 Administrative Inspection · Plan Review (Other than "T") · In-Service Inspection · Inclining Experiment · Construction Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3015233
9 January 2007 Hull Examination · COI Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2854132
20 July 2006 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2731828
13 July 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2755880
16 February 2006 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2586171
27 January 2006 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2574584
24 January 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2572590
20 January 2006 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2570214
4 November 2005 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2528487
27 October 2005 Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2523053
28 March 2005 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2321528
8 February 2005 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2292058
29 January 2005 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2289430
20 January 2005 Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2288093
17 December 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2265068
16 April 2004 Hull Examination · Internal Structural Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2045464
17 February 2004 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2007880
5 February 2004 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2000837
30 January 2004 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1996767
8 October 2003 In-Service Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1930547
24 October 2002 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1713017
22 October 2002 Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1694271
21 October 2002 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1693845
24 September 2002 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1679087
17 September 2002 Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1676833
27 December 2001 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1474119
22 December 2001 Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1474096
30 November 2001 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1441941
30 November 2001 Hull Examination · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1450677
10 August 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1070213
22 March 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 182931
20 August 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1395491
20 March 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 19625
1 December 1999 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1436354
26 August 1999 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1430727
24 August 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 30467
30 July 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1111178
7 April 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 786896
19 March 1999 Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1372605
12 January 1999 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 810817
11 January 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 69757
16 November 1998 Drydock Extension
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 807075
13 May 1998 Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1440010
17 January 1998 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1364527
3 December 1997 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1368501
4 November 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1119141
26 October 1997 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419843
15 July 1997 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1406129
16 June 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 665864
10 June 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 107026
31 May 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 150089
31 May 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 214457
31 May 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 216100
1 March 1997 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 5757
21 February 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 183939
1 February 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 87516
13 January 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 73356
27 November 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 873133
24 November 1996 Re-Inspection · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1353990
2 October 1996 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1147365
14 June 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 111076
5 December 1995 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1435698
15 March 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401995
28 February 1995 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1358663
21 February 1995 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1409238
6 December 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1143021
18 April 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1167419
15 January 1994 Examination of Repairs
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 850924
23 December 1993 Hull Examination · COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1159863
8 April 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1422220
7 February 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 465424
6 May 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1257910
11 February 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 944607
10 January 1992 COI Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1255062
20 September 1991 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 932575
30 July 1991 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1249016
11 January 1991 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1239912
9 March 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 900379
19 December 1989 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1213320
28 November 1989 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 929541
7 July 1989 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1198773
3 March 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1198138
22 December 1988 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1033840
18 April 1988 Deficiency Check · Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1031601
8 April 1988 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1342450
1 March 1988 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1339106
27 January 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1016400
18 December 1987 COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1007113
3 November 1987 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1327580
9 October 1987 Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1322458
16 April 1987 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1322321
30 March 1987 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1327272
12 March 1987 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1323368
24 February 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1323543
23 February 1987 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1015904
3 February 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012995
10 September 1986 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1313031
12 August 1986 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 964404
25 July 1986 Permit to Proceed
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1301740
18 June 1986 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 993659
3 June 1986 Damage Survey
Physical examination · THE UNKNOWN UNIT · Activity 991657
20 May 1986 Damage Survey
Physical examination · THE UNKNOWN UNIT · Activity 1300941
25 March 1986 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 995232
24 February 1986 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1296933
28 January 1986 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 996720
15 January 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1304456
21 December 1985 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1303573
20 December 1985 Credit Drydock · Initial Certification · Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 986278

Deficiency record · 180

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 April 2023 Resolved
At each inspection the inspector shall examine the machinery space to see there is no accumulation of oil which may create a fire hazard and the piping demonstrate leak tightness; both MDE preheat lube oil line at the engine heater connection is leaking past the gasket, must fix/replace to like new conditions and test with Coast Guard Marine Inspector (CGMI) and must also clean all oil residue in area prior to testing.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 April 2023
Resolution: Sea trials completed with CGMI and ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 April 2023 Resolved
At each inspection the inspector shall examine the machinery space to see there is no accumulation of oil which may create a fire hazard and the piping demonstrate leak tightness;port MDE has leaks at all injector leak off lines causing a fire hazard, must conduct corrective action to stop leaks and prove proper operation with a CGMI during underway operations.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 April 2023
Resolution: Sea trials completed with CGMI & ABS
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 April 2023 Resolved
Nonmetallic flexible hose must be in accordance with SAE J1942 and must have factory assembled end fittings that meet SAE J1475 and be used where flexibility is required not to exceed 30inches; both MDE appear to have improper fire sleeves on fuel, lube oil, and miscellaneous systems, some are to large, short, clamps missing. Must prove lines are the required proper type and if sleeves are required they meet the regulation.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 April 2023
Resolution: Completed and checked by CGMI
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 April 2023 Resolved
CO2 cylinders must be rejected for further service when they leak, dented, severely corroded; vessel's Halon Fixed system for engine room has CO2 & Nitrogen pilot bottles which the CO2 bottle is wasted at the bottom, must have serviced and replace bottle as required by regulation.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 April 2023
Resolution: Fire servicing company changed out CO2 bottle with new & hydro date is 4/23
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 3 April 2023 Resolved
To ensure the adequate strength and watertightness of seams and closures of in-service immersion suits each suit be subjected to an air pressure test at intervals not exceeding three years. Suits shall be sent out for testing prior to going back in service after the upcoming scheduled dry dock.
Action required: 705 - Other - as specified
Due 31 July 2023
Resolved 27 December 2023
Resolution: Vessel provided certificate of testing for immersion suits.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 April 2023 Resolved
The warning placard to lockout the drag arm is covered in soot, clean up the placard prior to going back into service/operation. Cleared while onboard
Action required: 10 - Deficiency Rectified
Due 3 April 2023
Resolved 3 April 2023
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 April 2023 Resolved
Exhaust pipe shall conform to ABYC P-1 and part 1, section 23 of NFPA 302 and meet ABS part 4 which all require to be gas tight; both MDE have large amounts of shoot on lagging and some lagging has become worn through and system has many apparent leaks at connections/flanges causing a crew hazard, must fix all issues and prove to CGMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 April 2023
Resolution: Engine manufacture rep corrected issues with ships crew
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 3 April 2023 Resolved
WTD has 2 signs for open/close operation but both do not match causing confusing for the crew during an emergency, must fix so crew understands.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 April 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 April 2023 Resolved
Cable retention devices should be installed not less than every 610 mm (24 in) on vertical and horizontal runs, including turns; vessel engine room electrical runs IWO engines and throughout the space need proper cable retention devices to prevent damage. (use of wire ties is for bundling only)
Action required: 705 - Other - as specified
Due 31 July 2023
Resolved 18 April 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2023 Resolved
Nonmetallic flexible hose must be in accordance with SAE J1942 and must have factory assembled end fittings that meet SAE J1475 and be used where flexibility is required not to exceed 30inches; SSDG #3 has a chaffed fuel line after the secondary filter, this line must be replaced to OEM specifications.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 April 2023
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 3 April 2023 Resolved
The WTD IWO steering room entrance has no alarm as required, must fix to original approved condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 April 2023
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 3 April 2023 Resolved
The overhead ducting in dredge pump room on STBD side is wasted and could fall at anytime causing a crew hazard; must fix to original condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 April 2023
Resolution: Temp fix complete, DD will be next fix in kind.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 3 April 2023 Resolved
Instructions for the operation of a fixed fire extinguishing system must be posted next to the fire apparatus; vessel Halon system for engine room states turn two red valves (2) but only one valve is red, must make sure proper directions for use and markings apply.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 April 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 March 2023 Resolved
Vessel experienced a reduction in propulsion after port side controllable pitch propeller clutched out while transiting in the Port of New York and New Jersey. CG-835V to be cleared upon submission of causal analysis, submission of repair proposal, and satisfactory repairs. All vessel movements are to be coordinated through Vessel Traffic Service.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 22 March 2023
Resolved 15 March 2023
Resolution: Vessel submitted satisfactory videos of operational tests.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2022 Resolved
46 CFR 111.01-1 (a) (2)-Electric installations on must ensure protection of pax, crew, other persons, and the vessel from electrical hazards; junction box for solenoid on #1 Start Air Compressor is missing cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 18 April 2022
Resolution: Cover replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 30 March 2022 Resolved
46CFR 97.15-20 (a) (1)-It shall be the responsibility of the Master to assure that all hatches are made properly watertight; Manhole cover in ER void is missing hardware and not made watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 18 April 2022
Resolution: Manhole Cover attached properly
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 March 2022 Resolved
46 CFR 199.110 (d): Each muster station and embarkation station must be adequately illuminated by lighting with power supplied from the vessel's emergency source of electrical power; Both spot lights at port side rescue boat and embarkation station do not work.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 18 April 2022
Resolution: Light bulbs replaced; test sat
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 30 March 2022 Resolved
46CFR 199.180: Training material must be on board each vessel and must consist of a manual of one or more volumes written in easily understood terms and illustrated wherever possible, or of audiovisual training aids IAW 199.180; Master was unable to provide manual.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 21 April 2022
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 7 May 2021 Resolved
Received report from vessel B.E. LINDHOLM of the AIS display unit being inoperable. However, the AIS is still transmitting and receiving. Additionally, the vessel can still track and identify vessels via radar. The vessel can depart Mobile, Alabama, and proceed to Brownsville, Texas. There, the vessel shall have repairs completed by May 13, 2021.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2021
Resolved 10 May 2021
Resolution: Received proof of repair. Uploaded to docs.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 23 February 2021 Resolved
Each rescue boat launching appliance must be capable of hoisting the rescue boat when leaded with its full rescue boat complement of persons and equipment at a rate of not less than 0.3 meters per second (50 feet per minute). Vessel's rescue boat davit winch motor is not operational. Current recovery is by manual hand crank not meeting the speed recovery requirements.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 1 March 2021
Resolution: Deficiency to be corrected within 7 days to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 29 December 2020 Resolved
A compartment containing the emergency source of electric power adjoining a space containing SSGs shall have all adjoining decks and bulkheads constructed of A-60 requirements. A three square foot area of insulation was missing under the emergency generator compartment and the engine room escape route/emergency generator room access door was not an A-60 door/configuration.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2021
Resolved 4 January 2022
Resolution: Received documents from Company proving door was installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 December 2020 Resolved
All fire-extinguishing equipment is required to be in a suitable condition. The doors accessing the fixed halon extinguishing bottles will not fully open when the small boat is placed in the cradle, which hampers actuation of the halon system at the storage space containing the halon bottles.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2021
Resolved 4 January 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 December 2020 Resolved
Each item of electrical equipment within a hazardous location (paint locker) must be explosion-proof, flame proof, or intrinsically safe. The electrical cable for the lights in the overhead of the paint locker was not installed correctly and did not have appropriate packing glands. The electrical cable for the heat detector in the paint locker was not installed correctly and did not appear to have an approved packing gland, and the high water float/sensor in the paint locker did not appear to have the appropriate approved type.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2021
Resolved 4 January 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 December 2020 Resolved
Fixed fire extinguishing systems are required in spaces containing internal combustion or auxiliary machinery. While removing the halon bottles to be weighed in accordance with table 91.25-20(a)(2), the wire cabling cracked the pressure gauge connection causing one halon bottle to leak out into the environment; subsequently rendering the halon fixed fire extinguishing system inoperable and thus no longer in a serviceable condition. In addition, the two remaining halon bottles failed visual inspection. Provide U.S. Coast Guard Marine Safety Center approved plans prior to installation of a replacement fixed fire extinguishing system or provide three replacement halon bottles and an acceptable report documenting compliance with EPA standards and proper installation.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 29 December 2020
Resolved 7 January 2021
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 December 2020 Resolved
GMDSS equipment must be so designed that the main units can be replaced readily, without elaborate recalibration or readjustment. Where applicable, equipment must be constructed and installed so that is is readily accessible for inspection and on-board maintenance purposes. Vessel did not have proof of shore based maintenance availability. 47 CFR 80.1105 46 CFR 91.21-10
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2021
Resolved 5 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 November 2019 Resolved
Vessel has lost all stern tube oil from the starboard shaft seal. Vessel Master stated that the vessel will need to go into dry-dock to make effective repairs. Prior to any movement provide a repair proposal to the satisfaction of a USCG Marine Inspector from Sector New York. This is to ensure of the safety and seaworthiness of the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2019
Resolved 7 December 2019
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 21 August 2019 Resolved
Drawings of alterations shall be approved before work is started unless deemed unnecessary by the Officer in Charge, Marine Inspection. The following requirements/expectations was conveyed to the above in attendance: 1)Gauging of the ballast tank bulkhead 2)Gauging of the elbows of the spray nozzles that are adjacent to any critical structure or vital systems including appendages. 3)Marine cert for entry to ballast tank to access damage 4)Repair proposal for 3 inch hole in ballast tank bulkhead(contingent upon if gauging reveals further damage to ballast tank bulkhead.)
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 21 August 2019
Resolved 28 August 2019
Resolution: Vessel performed repairs in accordance with repair proposal. Repairs were overseen through its entirity by ABS surveyor and CG Marine Inspectors. Leak test (Hydro-Tank) NDT was performed, all repairs satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 19 August 2019 Resolved
Conduct permanent reapirs to eroded liquifaction pipe and aft bulkhead of fwd. ballast tank, submit plans to ABS for approval with concurrence from CG
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2019
Resolved 28 August 2019
Resolution: Vessel made repairs at Bayonne, NJ. Refer to activity
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2019 Resolved
Vessel reported loss of port rudder at rudder stock flange and wants to confirm no damage to starboard rudder. Transit to Sandy Hook Bay in accordance with proposed plan to determine soundness of starboard rudder arrangement. Provide dive report prior to dredging operations.
Action required: 705 - Other - as specified
Resolved 10 July 2019
Resolution: received dive survey and uploaded to this activity
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2019 Resolved
Vessel reported loss of port rudder at rudder stock flange. Conduct permanent repairs to port rudder arrangement. ** Amended on 10JUL19 ** Due to the reduced maneuverability of the vessel, a stand-by tug of sufficient HP must remain with the vessel at all times until cleared. Notification to the cognizant OCMI must be made if transiting to areas outside of accepted routes within the vessels proposed operational plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 August 2019
Resolution: Vessel made proper repairs and steering gear was properly tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2019 Resolved
Vessel reported loss of port rudder at rudder stock flange. Conduct permanent repairs to port rudder arrangement. Due to the reduced maneuvarability of the vessel, a stand-by tug of sufficient HP must remain with the vessel at all times until cleared. Notification to the cognizant OCMI must be made if transiting to areas outside of accepted routes within the vessels proposed operational plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 August 2019
Resolution: Vessel made proper repairs and demonstrated proper operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 July 2019 Resolved
Vessel lost communication from the bridge to the port main diesel engine. Complete repairs and tests of the port MDE prior to the continuation of dredging operations. The vessel shall review the entire system and report finding to the USCG.
Action required: 705 - Other - as specified
Resolved 16 July 2019
Resolution: Received GE technician report attesting to the replacement of power switch #1.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 June 2019 Resolved
Vessel lost communication from the bridge to the port main diesel engine. Complete repairs and tests of the port MDE prior to the continuation of dredging operations.
Action required: 705 - Other - as specified
Resolved 15 June 2019
Resolution: Received tech report clearing deficiency.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 15 November 2018 Resolved
Drawings of alterations shall be approved before work is started unless deemed unnecessary by the Officer in Charge, Marine Inspection. The vessel has reported the inflow of water by way of five (05) pin hole leaks found in the athwart ship bulkhead separating the aft portion of the vessels hopper from the vessels pump room. Provide plans to this office for approval proving effective repairs. Following, USCG Marine Inspector's must attest to proper repairs of identified area prior to departure from Sector New York AOR.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2018
Resolution: Repairs conducted and testing of welds conducted. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 6 November 2018 Resolved
Each propeller on a rescue boat must be fitted with a propeller guard with a maximum opening of 76 mm (3 in) on all sides on which a person is likely to be exposed. Rescue boat was found to not have an installed propeller guard as required, install within 30-days. 46 CFR 160.156-7(b)(11); 50c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2018
Resolved 22 November 2018
Resolution: New prop was placed on the rescue boat with a propeller guard. Def Cleared.
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 22 March 2018 Resolved
Demonstrate most resent Periodic Safety Test Procedures (PSTP), to the satisfaction of attending CG Marine Inspector, for final Marine Safety Center (MSC) approval.
Action required: 10 - Deficiency Rectified
Due 30 September 2018
Resolved 1 November 2018
Resolution: CG inspectors witnessed completion of MSC approved PSTPs.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 6 February 2018 Resolved
1. CO2 bottles for jet drive resting directly on deck. Provide a 2" air gap.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 16 February 2018
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 6 February 2018 Resolved
2. Crew had ran oxygen/acetelyn hose from aft end forward. Several sections are worn through. Remove hose and/or properly run oxygen/acetelyn hope or pipe.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 6 February 2018
Resolution: Hose removed while on board. Item cleared.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 6 February 2018 Resolved
3. Prove proper operation of "A" class boundary. Excessive gap found on door between engine space and welding room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 16 February 2018
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 11 October 2016 Resolved
Aft gen space vent closure inop. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 October 2016
Resolution: Vent closure all operational.
Engineering › Fuel Oil Service System › Valve
Issued 11 October 2016 Resolved
Main fuel oil quick-close valve inop. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2016
Resolution: Corrected on spot.
Lifesaving › Rigid Liferafts › Carriage Requirement
Issued 11 October 2016 Resolved
Port side life rafts not installed. Life rafts must be installed.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 October 2016
Resolution: Life rafts properly installed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 October 2016 Resolved
Stbd lifelines missing from railing. Ensure req'd rails in place.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 13 October 2016
Resolution: All lifelines and rails in place.
Fire Fighting › Structural - A Class Divisions › Windows
Issued 11 October 2016 Resolved
Porthole stbd qtr missing dogs to be secured. Ensure porthole can be secured.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 13 October 2016
Resolution: Porthole repaired and capable of being secured.
Engineering › Lubricating Oil Service System › Expansion Joint
Issued 11 October 2016 Resolved
Replace non-metallic expansion coupling port MDE J/W cooling line, inspected and found it to be split and dry rotted.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 October 2016
Resolution: Non-metallic expansion coupling replaced with new coupling.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 11 October 2016 Resolved
Either create or stencil non-metallic expansion joints to conform and prove that they are not older than 10 years.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 13 October 2016
Resolution: All non-metallic expansion joints stenciled and maintenance log created for inspection intervals.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 11 October 2016 Resolved
J/W discharge hoses on #1 and #2 SSDE are dry-rotted, replace and double clamp.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 October 2016
Resolution: Hoses replaced, renewed, and double-clamped.
Engineering › Fuel Oil Service System › Hose
Issued 11 October 2016 Resolved
Heat shields on both MDE's fuel and oil lines are not properly installed. Prove proper installation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 13 October 2016
Resolution: Heat shields properly installed.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 17 December 2015 Resolved
While docked at BAE, make satisfactory repairs to the vessel's port stern tube seal compulsory to regulation 46 CFR 58.05-1. Repairs are to be made to the satisfaction of American Bureau of Shipping surveyors and USCG [name withheld] prior to departure from the Port of Jacksonville.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2015
Resolution: Marine Inspectors and ABS Class surveyor witnessed and approved repairs. Class report to follow.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 15 December 2015 Resolved
The B.E. Lindholm suffered port stern tube oil leak and now is unable to use port engine w/o leaking oil. Make permanent repairs to the satisfaction of the attenging CG marine inspector. The vessel is authorized to transit to Jacksonville, FL on the stbd engine to make repairs provided conditions are met. 46cfr58.05-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2016
Resolved 13 April 2016
Resolution: All repairs to port tailshaft bearings have been completed and tested. CPP tested sat.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 18 November 2015 Resolved
Vessel's port Controllable Pitch Propeller system would not shift from astern propulsion upon command. Identify and repair cause of malfunction and prove proper operation to attending Coast Guard Marine Inspector.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2015
Resolution: Coast Guard Marine Inspectors conducted underway testing of the port and starboard controllable pitch propeller systems, including duplication of the failure and resolution of the same.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 16 November 2015 Resolved
Vessel's Periodic Safety Test Procedures were reviewed by MSC, but never approved through verification testing. Conducted verification testing during COI inspection. Vessel must make revisions and re-submit PSTPs for final approval.
Condition: Placed in Improper Service
Due 24 April 2018
Resolved 22 March 2018
Resolution: Administratively cleared and reissued
Lifesaving › Launching Appliances › Release Mechanism
Issued 23 May 2014 Resolved
New davit and rescue boat release gear are not properly placarded/marked, missing USCG approval and "SOLAS" marking. Provide proper placards for the davit release gear to the satisfaction of an attending Coast Guard Marine Inspector IAW 46 CFR 199.40 (a).
Action required: 705 - Other - as specified
Due 23 June 2014
Resolved 8 July 2014
Resolution: Vsl had proper placards and markings on davit and rescue boat release gear
Lifesaving › Launching Appliances › Davit
Issued 22 May 2014 Resolved
Vessel installed a new rescue boat and rescue boat davit without obtaining USCG approval of davit installation procedures from COMDT Marine Safety Center (MSC). Provide approved installation drawing from the USCG MSC IAW 46 CFR 199.40 (d). (Originally a no-sail - then extended to 06 June 2014 following satisfactory testing of equipment).
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2014
Resolved 4 June 2014
Resolution: Received MSC approvals for Rescue Boat Davit Installation. All Sat.
Lifesaving › Rescue Boat › Construction
Issued 22 May 2014 Resolved
Vessel installed a new rescue boat and rescue boat davit. Provide USCG type approval documentation for the rescue boat and the rescue boat davit to the satisfaction of the attending USCG Marine Inspector IAW 46 CFR 199.40 (a).
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 May 2014
Resolved 23 May 2014
Resolution: Provided USCG approval documentation to the attending CG Marine Inspector. Discussion with USCG MSC validated approvals.
Lifesaving › Launching Appliances › Davit
Issued 22 May 2014 Resolved
Vessel installed a new rescue boat and rescue boat davit without USCG oversight from the local [name withheld] davit foundation welds available for inspection and perform required N.D.T. to the satisfaction to the attending Coast Guard Marine Inspector IAW 46 CFR 199.10 (J).
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 24 May 2014
Resolved 23 May 2014
Resolution: Welds were made available to attending MI who was able to witness surface NDT (dye pen & mag particle) by a certified Type II NDT technician.
Lifesaving › Launching Appliances › Davit
Issued 22 May 2014 Resolved
Vessel installed a new rescue boat and rescue boat davit. Make installation available for inspection and perform all required testing to the satisfaction of the attending USCG Marine Inspector IAW 46 CFR 199.45 (a)(c).
Action required: 17 - Rectify deficiencies prior to departure
Due 24 May 2014
Resolved 23 May 2014
Resolution: Single point davit weight test, rescue boat weight test, on-load release gear test, and rescue boat operational steering and propulsion test completed satisfactorily in the presence of a USCG Marine Inspector.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 23 June 2011 Resolved
Embarkation lighting providing illumination to the area of water into which lifesaving appliance is launched missing. (46 CFR 111.75-16 a ) .
Condition: Improper Installation
Due 30 June 2011
Resolved 30 June 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 February 2011 Resolved
portside lower side light bulb out; repaired sat.
Condition: Improper/Lack of Maintenance
Due 30 June 2011
Resolved 30 June 2011
Construction/Loadline › Hull › Bottom Plating
Issued 10 September 2008 Resolved
Vessel experienced flooding of keelson box while dredging Brazos Santiago Pass. Temporary repair was made but the fracture migrated into the pump room when dredging resumed. Dredge has two temporary repairs to hull fractures in keelson box. Significant wastage to hull and structure near frame 85. Make permanent repairs prior to resuming dredging.
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 28 October 2008
Resolution: Completed permanent repairs to hopper doors at Bender Shipbuilding, Mobile AL.
Electrical › Electrical Distribution System (emergency) › Ground Detection
Issued 21 September 2007 Resolved
Locate and correct partial ground on E-SWBD.
Action required: 705 - Other - as specified
Due 21 October 2007
Resolved 24 September 2007
Resolution: Corrected ground on E-SWBD.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 21 September 2007 Resolved
Install lagging on SSDG turbos.
Action required: 705 - Other - as specified
Due 21 October 2007
Resolved 24 September 2007
Resolution: Installed laggin on SSDG turbos.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 21 September 2007 Resolved
Find and repair L/O & H/O leaks in engineroom.
Action required: 705 - Other - as specified
Due 21 October 2007
Resolved 24 September 2007
Resolution: Repaired leaks.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 21 September 2007 Resolved
Remove excess L/O from engine room bilge.
Action required: 705 - Other - as specified
Due 21 October 2007
Resolved 24 September 2007
Resolution: Removed L/O from bilge.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 21 September 2007 Resolved
Repair hand pump on SWTD #14.
Action required: 705 - Other - as specified
Due 21 October 2007
Resolved 24 September 2007
Resolution: repaired hand pump on SWTD #14.
Engineering › Sea-water System (primary cooling) › Pump
Issued 21 September 2007 Resolved
Make repairs to #2 cooling water pump shaft packing.
Action required: 705 - Other - as specified
Due 21 October 2007
Resolved 24 September 2007
Resolution: Reduced leaking of #2 water pump shaft packing.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 21 September 2007 Resolved
Correct and submit revision to automation procedures for approval.
Action required: 705 - Other - as specified
Due 21 October 2007
Resolved 24 September 2007
Resolution: Updated and approved automation procedures.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 21 September 2007 Resolved
Adjust the WTD to the Emergency Disel Generator room.
Action required: 705 - Other - as specified
Due 21 October 2007
Resolved 24 September 2007
Resolution: Corrected. WTD.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 21 September 2007 Resolved
Crop and renew the MSD overboard discharge piping.
Action required: 705 - Other - as specified
Due 21 October 2007
Resolved 24 September 2007
Resolution: replaced MSD overboard discharge piping.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 9 January 2007 Resolved
Renew life lines and retro tape as needed on ring buoys
Due 9 January 2007
Resolved 9 January 2007
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 9 January 2007 Resolved
Replace one wasted lifejacket.
Due 9 January 2007
Resolved 9 January 2007
Fire Fighting › Fire Hydrants › Condition
Issued 9 January 2007 Resolved
repack or renew 2 leaking fire hydrants
Condition: Improper/Lack of Maintenance
Due 9 January 2007
Resolved 9 January 2007
Fire Fighting › Fire Hoses › Condition
Issued 9 January 2007 Resolved
Replace one burst fire hose main deck
Due 9 January 2007
Resolved 9 January 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 9 January 2007 Resolved
reaffix cable in aftersteering compartment with metallic hangers.
Condition: Improper/Lack of Maintenance
Due 9 January 2007
Resolved 9 January 2007
Stability › Watertight Integrity › General
Issued 9 January 2007 Resolved
repair local control (manual hand crank) for WTD closure at pump room.
Due 9 January 2007
Resolved 9 January 2007
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 20 July 2006 Resolved
Repair and prove operation and control of starboard variable pitch propeller to the satisfaction of the attending marine inspector. Cognizant Officer in Charge, Marine Inspection shall be notified prior to entry into port due to limited maneuverability.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 August 2006
Resolved 24 November 2006
Fire Fighting › Fire Hoses › Condition
Issued 16 February 2006 Resolved
Prove fire hose a main deck station #6 failed hydrostatic test as required by 46 CFR 95.10-10.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2006
Resolved 16 February 2006
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 16 February 2006 Resolved
Provide 7 type I PFD's as required by 46 CFR 199.70.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2006
Resolved 16 February 2006
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 16 February 2006 Resolved
Make machinery space available for inspection (remove excessive oily waste) as required by 46 CFR 91.25-45.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2006
Resolved 16 February 2006
Construction/Loadline › Structures › Door
Issued 16 February 2006 Resolved
Properly repair or renew in kind, QAWTD on main deck, port side, forward deck house wasted and not watertight as required by 46 CFR 92.01-5.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 24 November 2006
Construction/Loadline › Structures › Door
Issued 16 February 2006 Resolved
Prove QAWTD on main deck house, port and starboard side, (out of adjustment and not watertight) as required by 46 CFR 92.01-5.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2006
Resolved 16 February 2006
Construction/Loadline › Structures › Door
Issued 16 February 2006 Resolved
Prove QAWTD IWO fire station # 10 as required by 46 CFR 92.01-5.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2006
Resolved 16 February 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 16 February 2006 Resolved
Provide proper life line on lifebuoy on fantail, starboard side, as required by 46 CFR 199.70.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2006
Resolved 16 February 2006
Fire Fighting › Structural Fire Protection - General
Issued 30 January 2004 Resolved
Remove holdbacks on fire doors in stairway. LEGACY COMPONENT DESC: Fire Door Holdbacks
Due 30 January 2004
Resolved 5 February 2004
Resolution: All holdbacks have been removed from fire doors in the stairtower.
Lifesaving › Immersion Suits
Issued 30 January 2004 Resolved
Relocate whistles from zipper to pocket area on all immersion suits. LEGACY COMPONENT DESC: Whistles
Due 30 January 2004
Resolved 5 February 2004
Resolution: All immersion suit whistles have been relocated to the pocket area.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 30 January 2004 Resolved
Update fire control plan to remove symbol indicating lifebuoy's with both line and lights attached. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 30 January 2005
Resolved 22 June 2004
Deck/Cargo
Issued 22 October 2002 Resolved
Proceed to Bollinger Shipyard, Texas City, Texas and affect permanent repairs to vessel's bow.
Condition: Damaged By Earlier Event
Due 1 November 2002
Resolved 16 November 2002
Resolution: Witnessed sat repair of vessel''s bow.
Documentation › Safety/Response Plans/Programs
Issued 24 September 2002 Resolved
Provide approved fire control plan onboard vessel. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Unknown
Due 24 October 2002
Resolved 26 September 2002
Resolution: Completed sat. Def check.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 24 September 2002 Resolved
Prior to operating conduct servicing for fixed halon system installed in paint locker. LEGACY COMPONENT DESC: Operating Controls
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2002
Resolved 26 September 2002
Resolution: Received third party fire protection''''s technicians report.
Accommodation/Occupational Safety › Medical/First Aid
Issued 24 September 2002 Resolved
Provide updated medicine for expired medicines in hospital space. LEGACY COMPONENT DESC: Medicine Chest
Condition: Unknown
Due 24 October 2002
Resolved 26 September 2002
Resolution: Completed sat def check.
Accommodation/Occupational Safety › Ventilation
Issued 24 September 2002 Resolved
Prove proper operation of all vent closures for engineroom and pumprooms.
Condition: Unknown
Due 24 October 2002
Resolved 26 September 2002
Resolution: Completed sat. def check.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 24 September 2002 Resolved
Repair hydraulic leak on anchor caismin.
Condition: Unknown
Due 24 October 2002
Resolved 26 September 2002
Resolution: Completed sat. def check.
Engineering › Shafting/Propeller Arrangements
Issued 22 December 2001 Resolved
Make permanant repairs to starboard stern tube seal. Vessel permitted to proceed to Charleston, SC for repairs. LEGACY COMPONENT DESC: Stern Tube Lubrication/Sealing
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 January 2002
Resolved 27 December 2001
Resolution: Witnessed sat repair & pressure test of stbd stern tube hub piping.
Construction/Loadline
Issued 30 November 2001 Resolved
RENEW AS ORIGINAL SOUNDING TUBES FOR THE #4 PORT VOID.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Construction/Loadline
Issued 30 November 2001 Resolved
MAKE NEW VALVE INSTALLATION IN FORWARD BALLEST TANK ACCESSABLE FOR INSPECTION.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Deck/Cargo › Ballast
Issued 30 November 2001 Resolved
PROVE REACH RODS FOR JET VALVES IN #4 PORT AND STBD VOIDS. LEGACY COMPONENT DESC: Valves
Condition: Unknown
Due 30 December 2001
Resolved 27 December 2001
Engineering › Freshwater System (jacketwater cooling)
Issued 30 November 2001 Resolved
RENEW DEFECTIVE JACKET WATER SENSOR ON #2 SSDG. LEGACY COMPONENT DESC: Sensor
Condition: Unknown
Due 30 December 2001
Resolved 27 December 2001
Communications › Internal Communications System
Issued 30 November 2001 Resolved
PROVE PROPER OPERATION OF THE ENGINE ORDER TELEGRAPH LEGACY COMPONENT DESC: Engine Order Telegraph System
Due 30 December 2001
Resolved 27 December 2001
Engineering › Freshwater System (jacketwater cooling)
Issued 30 November 2001 Resolved
PROVE PROPER OPERATION OF THE STARBOARD MAIN ENGINE JACKET WATER SENSOR. LEGACY COMPONENT DESC: Sensor
Condition: Unknown
Due 30 December 2001
Resolved 27 December 2001
Communications › Alarms/Indicators
Issued 30 November 2001 Resolved
PROVE GENERAL ALARM BELLS OF AFT HOUSE BULKHEAD AND AFT OF STERN STACK. LEGACY COMPONENT DESC: General Alarm
Condition: Unknown
Due 30 December 2001
Resolved 27 December 2001
Communications › Alarms/Indicators
Issued 30 November 2001 Resolved
PROVE ROTATING LIGHT FOR GENERAL ALARM IN THE ENGINEROOM LEGACY COMPONENT DESC: General Alarm
Condition: Unknown
Due 30 December 2001
Resolved 27 December 2001
Lifesaving › Line-Throwing Appliances
Issued 30 November 2001 Resolved
PROVIDE ADDITIONAL LINE THROWING ROCKETS FOR A TOTAL OF FOUR ON BOARD LEGACY COMPONENT DESC: Projectiles
Condition: Unknown
Due 30 December 2001
Resolved 27 December 2001
Fire Fighting › Self-contained Breathing Apparatus
Issued 30 November 2001 Resolved
REPLACE ONE COMPOSITE SCBA BOTTLE LEGACY COMPONENT DESC: Air Bottle
Condition: Unknown
Due 30 December 2001
Resolved 27 December 2001
Construction/Loadline
Issued 10 August 2001 Resolved
AT NEXT DRYDOCK PERIOD/HAUL OUT REMOVE ALL SAND IN FORWARD BALLAST TANK ANDCONDUCT EXTENSIVE INSPECTION OF THE TANK.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Construction/Loadline
Issued 10 August 2001 Resolved
RENEW GASKET TO HATCH COVER TO NUMBER 5 PORT VOID TANK.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Construction/Loadline
Issued 10 August 2001 Resolved
CROP & RENEW NO. 6 INBOARD AFT GUSSET PLATE & TRANSVERSE ANGLE STIFFNERS INNO 4 PORT VOID TANK.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Construction/Loadline
Issued 10 August 2001 Resolved
CROP & RENEW NO. 7 & 8 INBOARD AFT GUSSET PLATES IN NO. 4 PORT VOID TANK.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Construction/Loadline
Issued 10 August 2001 Resolved
CROP & RENEW NO.9 & 10 INBOARD AFT GUSSET PLATE & TRANSVERSE ANGLE STIFFNERS IN NO. 4 PORT VOID TANK.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Construction/Loadline
Issued 20 March 2000 Resolved
The port side of the keelson box aft of frame 70 developed a leak from erosion. The M/V B.E. LINDHOLM is a hopper dredge that holds the dredge spoils onboard. The leak developed from erosion between the dredge spoils and the metal on the vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 30 November 2001
Navigation
Issued 1 December 1999 Resolved
Repair light for magnetic compass.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Navigation
Issued 1 December 1999 Resolved
Correct / eliminate 4 degree discrepancy between rudder stock and bridge rudder angle indicators._x001C_ _x001C_
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Navigation
Issued 1 December 1999 Resolved
Correct / eliminate 5 degree discrepancy between port side bridge wing rudder angle indicator and main bridge rudder angle indicator.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Engineering
Issued 1 December 1999 Resolved
Test all pressure vessel relief valves.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Construction/Loadline
Issued 1 December 1999 Resolved
Repair or replace portside jet pumproom bilge alarm.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Lifesaving
Issued 1 December 1999 Resolved
Replace / repair ring buoy waterlight in way of port side aft main deck.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Fire Fighting
Issued 1 December 1999 Resolved
Replace wasted Halon discharge piping in paint locker, reconnect system, and provide portable B-II fire extinguisher outside paint locker until completed.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Electrical
Issued 1 December 1999 Resolved
Tighten cover on explosion-proof fixture.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Construction/Loadline
Issued 1 December 1999 Resolved
Provide satisfactory seal on port and starboard forward bridge wing doors, port and starboard main deck athwartships passageway doors, and all main deck watertight doors._x001C_ _x001C_
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Lifesaving
Issued 1 December 1999 Resolved
Replace all expired personal waterlights on immersion suits and PFDs.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Fire Fighting
Issued 1 December 1999 Resolved
Provide satisfactory seal on Paint Locker gooseneck vent closure.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Construction/Loadline
Issued 26 August 1999 Resolved
Make permanent repairs to inboard common bulkhead of #2 & #3 stbd fuel oil tanks (crack in #2 F.O. tank, IWO aft/#2 bulkhead longitudinal). Repairs to be completed as described in ABS survey report, to satisfaction of attending USCG inspector. Vessel not to operate until corrected.
Condition: Unknown
Due 26 August 1999
Resolved 27 August 1999
Deck/Cargo
Issued 19 March 1999 Resolved
REPLACE EXCESSIVELY LONG HYDRAULIC HOSE IN AFT STEERING FLAT (>30") WITH FIXED PIPING.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Electrical
Issued 12 January 1999 Resolved
PROVE PROPER OPERATION OF MAIN ENGINE CLUTCHES.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Construction/Loadline
Issued 4 November 1997 Resolved
CONDUCT PERMANENT REPAIRS IN WAY OF TEMPORARY COFFER DAM IN KEELSON BOX VOID. REPAIRS SHALL BE TO THE SATISFACTION OF COGNIZANT OCMI.
Condition: Unknown
Due 4 November 1997
Resolved 4 November 1997
Construction/Loadline
Issued 15 July 1997 Resolved
DRYDOCK VESSEL TO PROPERLY REPAIR CRACKED WELD IN BOTTOM PLATE AT FRAME 85 INBOARD KEELSON BULKHEAD.
Condition: Unknown
Due 15 July 1997
Resolved 15 July 1997
Engineering
Issued 15 July 1997 Resolved
PROPERLY REPAIR AND PROVE PROPER OPERATION OF PORT MAIN ENGINE AND ASSOCIATED AUTOMATION FUNCTIONS
Condition: Unknown
Due 15 July 1997
Resolved 15 July 1997
Engineering
Issued 10 June 1997 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 30 June 1997
Resolved 30 December 2001
Navigation
Issued 1 February 1997 Resolved
***SEE MCNS***
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 30 November 2001
Engineering
Issued 24 November 1996 Resolved
PROVE PROPER OPERATION OF BOTH MAIN DIESEL ENGINES PRIOR TO DREDGE OPERATION.
Condition: Unknown
Due 24 November 1996
Resolved 24 November 1996
Documentation
Issued 24 November 1996 Resolved
Provide current stability letter, issued by U.S. Coast Guard or ABS on behalf of the Coast Guard prior to any dredging operations.
Condition: Unknown
Due 9 December 1996
Resolved 9 December 1996
Construction/Loadline
Issued 24 November 1996 Resolved
COMMENCE PERMANENT REPAIRS TO THE PORT AND STARBOARD TRUNNION GUIDES.
Condition: Unknown
Due 24 November 1996
Resolved 24 November 1996
Lifesaving
Issued 28 February 1995 Resolved
Renew six failed immersion suits prior to conducting operations outside thearea north of latitude 32S and south of latitude 32N.
Condition: Unknown
Due 28 February 1995
Resolved 28 February 1995
Fire Fighting
Issued 28 February 1995 Resolved
Prior to departure, service all on board portable fire extinguishers.
Condition: Unknown
Due 28 February 1995
Resolved 1 March 1995
Lifesaving
Issued 28 February 1995 Resolved
Provide on board proper Impulse Projectile Line Throwing Gun consistant with the provisions of 46 CFR 94.45-15.
Condition: Unknown
Due 28 February 1995
Resolved 28 February 1995
Engineering
Issued 28 February 1995 Resolved
Repair and prove proper operation of #1 and #2 Main Diesel Engine overspeedtrip mechanisms.
Condition: Unknown
Due 28 February 1995
Resolved 28 February 1995
Fire Fighting
Issued 28 February 1995 Resolved
Renew nitrogen bottle, properly charged and configured, for Engine Room Fixed firefighting system prior to getting underway.
Condition: Unknown
Due 28 March 1995
Resolved 1 March 1995
Engineering
Issued 28 February 1995 Resolved
Conduct bench testing of five air receiver relief valves.
Condition: Unknown
Due 28 February 1995
Resolved 28 February 1995
Engineering
Issued 6 December 1994 Resolved
LABEL ALL FUEL TANK VENTS.
Condition: Unknown
Due 6 December 1994
Resolved 6 December 1994
Electrical
Issued 6 December 1994 Resolved
REMOVE DEAD-END CABLE STARBOARD SIDE ON DECK AT OUTLET.
Condition: Unknown
Due 6 December 1994
Resolved 6 December 1994
Engineering
Issued 6 December 1994 Resolved
LABEL ALL REMOTE FUEL OIL SHUTOFF VALVES.
Condition: Unknown
Due 6 December 1994
Resolved 6 December 1994
Construction/Loadline
Issued 6 December 1994 Resolved
MAKE PENETRATION IN BULKHEAD AT FIRE STATION NUMBER 5 WATERTIGHT (AFT DECK AT WATERTIGHT DOOR)
Condition: Unknown
Due 6 December 1994
Resolved 6 December 1994
Electrical
Issued 6 December 1994 Resolved
REMOVE PLASTIC WIRE TIES IN ENGINE ROOM AND REPLACE WITH PROPER METAL CLIPSAND PROVIDE PROPER SUPPORTS AND RUNS FOR WIRES WHERE REQUIRED.
Condition: Unknown
Due 6 December 1994
Resolved 6 December 1994
Documentation
Issued 8 April 1993 Resolved
COMPLETE ALL 10 ITEMS LISTED ON WORKLIST DATED 07APR93.
Condition: Unknown
Due 9 April 1993
Resolved 9 April 1993
Documentation
Issued 10 January 1992 Resolved
Conduct operational test of automation procedure 17 item T (potable water tank level), page 34.
Condition: Unknown
Due 10 January 1992
Resolved 10 January 1992
Documentation
Issued 10 January 1992 Resolved
Rewrite automation test procedures and submit to [name withheld] for approval.
Condition: Unknown
Due 10 January 1992
Resolved 10 January 1992
Lifesaving
Issued 10 January 1992 Resolved
Provide onboard two pair of firemen outfit paints to complete 2 firemen outfits.
Condition: Unknown
Due 10 January 1992
Resolved 10 January 1992
Electrical
Issued 10 January 1992 Resolved
Conduct operational test of automation test procedure 6.1 items B,C and D_x001C_ on pg 19 (Voltage level, high amperage and frequency level).
Condition: Unknown
Due 10 January 1992
Resolved 10 January 1992
Electrical
Issued 10 January 1992 Resolved
Repair or replace aft welding lead connection box located on stbd pump access hatch.
Condition: Unknown
Due 10 January 1992
Resolved 10 January 1992
Construction/Loadline
Issued 20 September 1991 Resolved
PROCEED FROM BATON ROUGE, LOUISIANA TO AMERICAN MARINE IN NEW ORLEANS, LOUISIANA AND DRYDOCK VESSEL FOR REPAIRS OF THE HOLE IN THE BOTTOM PLATE INWAY OF THE STARBOARD MAIN ENGINE REDUCTION GEAR.
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Fire Fighting
Issued 28 November 1989 Resolved
RAISE FIXED HALON CYLINDER 2" OFF DECK IN PAINT LOCKER.
Condition: Unknown
Due 28 November 1989
Resolved 28 November 1989
Electrical
Issued 28 November 1989 Resolved
INSTALL ON EMERGENCY GENERATOR PRIME MOVER, AN AUDIBLE ALARM THAT SOUNDS ON LOW PRESSURE AND HIGH COOLING WATER TEMPERTURE.
Condition: Unknown
Due 28 November 1989
Resolved 28 November 1989
Electrical
Issued 28 November 1989 Resolved
DEMONSTRATE SATISFACTORY OPERATION OF EMERGENCY GENERATOR HIGH COOLING WATER TEMPERATURE ALARM
Condition: Unknown
Due 28 November 1989
Resolved 28 November 1989
Construction/Loadline
Issued 1 March 1988 Resolved
PLACE THE VESSEL IN DRYDOCK AND MAKE PROPER REPAIRS TO #3 PORT VOID AND #1,#2 & #3 PORT FUEL TANKS, AS REQUIRED BY THE COGNIZANT OCMI, NOT LATER THAN 20APR88.
Condition: Unknown
Due 1 March 1988
Resolved 1 March 1988
Construction/Loadline
Issued 1 March 1988 Resolved
MAKE THE NUMBER 3 VOID AVAILABLE FOR INSPECTION PRIOR TO DEPARTURE FROM THEPORT OF NEW YORK BUT NOT LATER THAN 20APR88.
Condition: Unknown
Due 1 March 1988
Resolved 1 March 1988
Documentation
Issued 18 December 1987 Resolved
INCLUDE IN OIL TRANSFER PROCEDURES DESIGNATED PERSON IN CHARGE.
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Electrical
Issued 18 December 1987 Resolved
COVER BLANK IN PANEL BOARD IN MACHINE SHOP PANEL BOARD AT TOP OF FORWARD LADDER AFTER MOST OF TWO.
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Deck/Cargo
Issued 18 December 1987 Resolved
PROVE FREE OPERATION OF THE #1 FUEL OIL BUNKER TANK REACH ROD ON STARBOARD SIDE
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Engineering
Issued 18 December 1987 Resolved
MAKE ALL (5) AIR RECEIVERS AVAIABLE FOR 150% HYDROSTATIC TEST OR INTERNAL EXAMINATION
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Engineering
Issued 18 December 1987 Resolved
COMPLETE ITEMS IN AUTOMATION PROCEDURES THAT MAY ONLY BE DONE DOCK SIDE ANDWERE NOT COMPLETED DURING THIS INSPECTION
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Fire Fighting
Issued 18 December 1987 Resolved
CONDUCT SERVICING OF VESSEL'S FIXED HALON FIRE FIGHTING SYSTEM INCLUDING OPERATION OF TIME DELAY AND VENTILATION SHUT DOWNS.
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Documentation
Issued 18 December 1987 Resolved
PROVIDE COPY OF COVER LETTER FROM [name withheld] DATED 03 FEBRUARY 1987 FOR APPROVAL OF ENGINEERING PLANT AUTOMATION PROCEDURES.
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Engineering
Issued 18 December 1987 Resolved
PROVE PROPER OPERATION OF ALL (5) FIVE AIR RECEIVER RELIEF VALVES BY LIFTING WITH GAS PRESSURE OR AIR.
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Engineering
Issued 18 December 1987 Resolved
PROVE PROPER OPERATION OF OILY WATER SEPERATOR OIL CONTENT METER.
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Engineering
Issued 9 October 1987 Resolved
REPAIRED DAMAGE TO THE PORT & STARBOARD PROPELLERS. REPLACED ALL BLADES ON THE STARBOARD UNIT AND FAIRED THE JAGGED EDGES ON THE PORT UNIT.
Condition: Unknown
Due 9 October 1987
Resolved 9 October 1987
Construction/Loadline
Issued 23 February 1987 Resolved
PROVE PROPER HAND OPERATION OF WATER TIGHT DOORS NUMBERS 1 AND 4.
Condition: Unknown
Due 23 February 1987
Resolved 23 February 1987
Accommodation/Occupational Safety
Issued 23 February 1987 Resolved
INSTALL A VACUUM BREAKER IN FRESH WATER CONNECTION TO FUEL OIL PURIFIER.
Condition: Unknown
Due 23 February 1987
Resolved 23 February 1987
Engineering
Issued 23 February 1987 Resolved
PROVE PROPER OPERATION OF STARBOARD MAIN ENGINE KILL SWITCH.
Condition: Unknown
Due 23 February 1987
Resolved 23 February 1987
Navigation
Issued 23 February 1987 Resolved
PROVE PROPER OPERATION OF THE LOSS OF STEERING ALARM.
Condition: Unknown
Due 23 February 1987
Resolved 23 February 1987
Accommodation/Occupational Safety
Issued 23 February 1987 Resolved
PROVIDE HAND RAILS FOR WALKWAYS IN FRONT OF BOTH MAIN ENGINES.
Condition: Unknown
Due 23 February 1987
Resolved 23 February 1987
Unknown
Issued 23 February 1987 Resolved
PROVIDE FIRE DETECTOR FOR ENGINE CONTROL ROOM (SCR).
Condition: Unknown
Due 23 February 1987
Resolved 23 February 1987
Fire Fighting
Issued 23 February 1987 Resolved
PROVIDE RELIEF VALVES WITH HAND LIFTING GEAR FOR STARTING AIR TANKS.
Condition: Unknown
Due 23 February 1987
Resolved 23 February 1987
Accommodation/Occupational Safety
Issued 23 February 1987 Resolved
PROVE PROPER OPERATION OF BOTH POTABLE AND SANITARY PRESSURE TANK RELIEF VALVES AND PROVE MAWP OF THE TANKS.
Condition: Unknown
Due 23 February 1987
Resolved 23 February 1987
Construction/Loadline
Issued 3 June 1986 Resolved
MAKE TEMP REPAIRS TO FRACTURE IN HULL INWAY OF STBD JET PUMP ROOM AS FOLLOWS: DRILL ENDS OF FRACTURE,BUILD STEEL BOX AROUND FRACTURE,FILL BOX WITH CONCRETE. VESSEL RESTRICTED TO COASTWISE VOYAGES UNTIL PERMANENT REPAIRS COMPLETED.
Condition: Unknown
Due 3 June 1986
Resolved 3 June 1986
Construction/Loadline
Issued 20 May 1986 Resolved
MAKE TEMP REPAIRS TO FRACTURE IN HULL IN WAY OF PORT JET PUMP ROOM. VESSEL IS RESTRICTED TO COASTWISE VOYAGES UNTIL PERMANENT REPAIRS ARE MADE. PERMANENT REPAIRS TO BE MADE BY 01AUG86.
Condition: Unknown
Due 20 May 1986
Resolved 20 May 1986
Engineering
Issued 21 December 1985 Resolved
OBTAIN, INSTALL AND PROVE OPERATIONAL THE PRINTED CIRCUIT BOARD FOR THE PORT AND STARBOARD WRONG DIRECTION ALARM FOR THE ENGINE ORDER TELEGRAPH.
Condition: Unknown
Due 21 December 1985
Resolved 21 December 1985
Fire Fighting
Issued 21 December 1985 Resolved
PROVIDE AND POST REVISED U.S. COAST GUARD APPROVED FIRE CONTROL PLAN.
Condition: Unknown
Due 21 December 1985
Resolved 21 December 1985
Lifesaving
Issued 21 December 1985 Resolved
PROVIDE 1500 FEET OF 9000 LB. TEST SYNTHETIC AUXILIARY LINE FOR LINE THROWING APPARATUS.
Condition: Unknown
Due 21 December 1985
Resolved 21 December 1985
Engineering
Issued 21 December 1985 Resolved
PROVIDE DOCUMENTATION THAT PORT AND STARBOARD MAIN ENGINE FUEL OIL FILTER HOUSING UNITS ARE U.S.C.G. APPROVED.
Condition: Unknown
Due 21 December 1985
Resolved 21 December 1985
Engineering
Issued 21 December 1985 Resolved
PROVIDE DOCUMENTATION FROM THE MANUFACTURER THAT THE COMPRESSED AIR DRYER REFRIGERATION UNITS ARE DESIGNED TO HANDLE 245 PSIG STARTING AIR PRESSURE.
Condition: Unknown
Due 21 December 1985
Resolved 21 December 1985
Engineering
Issued 21 December 1985 Resolved
PROVIDE REVISED AUTOMATED TEST PROCEDURES INCLUDING THE STEERING GEAR, FOR U.S.C.G. APPROVAL.
Condition: Unknown
Due 21 December 1985
Resolved 21 December 1985

Casualty record · 20

21 October 2002Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 1693845
8 February 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2292058
13 July 2006Routine · role: Involved in a Marine Casualty · activity 2755880
20 November 2006Routine · role: Involved in a Marine Casualty · activity 2826200
9 July 2007Routine · role: Involved in a Marine Casualty · activity 2991769
5 September 2008Routine · role: Involved in a Marine Casualty · activity 3320294
18 November 2015Routine · role: Involved in a Marine Casualty · activity 5796671
10 March 2017Routine · role: Involved in a Marine Casualty · activity 6136699
12 March 2017Routine · role: Involved in a Marine Casualty · activity 6136721
23 November 2017Routine · role: Involved in a Marine Casualty · activity 6332048
11 March 2018Routine · role: Involved in a Marine Casualty · activity 6459897
27 October 2018Routine · role: Involved in a Marine Casualty · activity 6575519
11 January 2019Routine · role: Involved in a Marine Casualty · activity 6613529
14 January 2019Routine · role: Involved in a Marine Casualty · activity 6613864
14 June 2019Routine · role: Subject to Marine Inspection · activity 6713733
1 July 2019Routine · role: Involved in a Marine Casualty · activity 6741661
9 January 2021Routine · role: Involved in a Marine Casualty · activity 7123984
22 February 2021Routine · role: Involved in a Marine Casualty · activity 7152767
2 July 2022Routine · role: Involved in a Marine Casualty · activity 7543218
14 March 2023Routine · role: Involved in a Marine Casualty · activity 7650733
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record