MAURY USCG vessel records
← All vessels

VICTORIA CLIPPER

Built
1986
Last inspected
1 October 2018
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 October 2018
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8520757
270113
Flag
CURACAO
Maury page id
psix-270113

Documentation record

Tonnage as PSIX records it431 - Regulatory (Subpart C or D), Gross Ton
431 - Convention (Subpart B), Gross Ton
177 - Displacement, Ton
76 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 6 inspections, each with its date, unit and type; 4 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 6

1 October 2018 COC-CVE Quarterly · ISPS III Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6549290
16 February 2018 COC-CVE Annual · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6350807
23 October 2017 ISPS II Exam · Deficiency Check · COC-CVE Quarterly
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6291776
17 February 2017 ISPS II Exam · COC-CVE Annual · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6089068
10 August 2016 COC-CVE Quarterly
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5968427
2 February 2016 ISPS II Exam · COC-CVE Annual
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5799678

Deficiency record · 4

Fire Fighting › Fire Hoses › Condition
Issued 23 October 2017 Resolved
The condition of the ship and its equipment shall be maintained. Hole in hose on upper deck. Removed, re-ordered and replaced. 74 SOLAS (14) I-11(a)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2017
Resolved 23 October 2017
Resolution: Corrected on the spot.
Fire Fighting › Fire Pumps › Casing
Issued 23 October 2017 Resolved
Machinery, associated piping, and fittings shall be of a design and construction adequate for intended service and installed to protect persons onboard. Exhaust leak on emergency fire pump. 74 SOLAS (81 Amendments) II-1, Reg 26.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2017
Resolved 26 October 2017
Resolution: Exhaust leak repaired. Found loose flange fitting on exhaust. Tightened and tested satisfactorily after 10 min run at full rpm with gas meter monitoring space.
Documentation › Logs/Records › Oil Record Book
Issued 23 October 2017 Resolved
The oil record book shall be completed when discharging overboard or disposal otherwise of bilge water from machinery spaces. Oil Record Book completed; not being used regularly. 73/78 MARPOL (11) I-17.2.4
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 November 2017
Resolved 26 October 2017
Resolution: Fleet wide email sent notifying all crew members to complete ORB. Will check during Annual exam.
Construction/Loadline › Hull › Weld
Issued 17 February 2017 Resolved
At the time of exam, found cracks along weld in inserts between engine room and lazerette space for engine exhaust. Crack also found between weld, of plate insert, for engine exhaust between lazerette space and hull. SOLAS 74 (2014 Cons.) I/11(c)
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 1 March 2017
Resolution: Received class report attesting to the satisfactory repairs and welds of aluminum structure.

Ownership record