Inspection history · 29
27 February 2026
Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8179788
10 September 2025
COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8139184
29 January 2025
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8047198
19 December 2024
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8024881
17 June 2024
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7929694
26 February 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7870605
21 December 2023
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7802003
6 November 2023
Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7820929
7 July 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7719077
14 December 2022
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7498481
3 June 2022
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7472045
4 May 2022
Drydock Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7443802
10 November 2021
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7327202
11 August 2021
Examination of Repairs · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7284664
1 December 2020
Examination of Repairs · In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7104135
22 September 2020
Internal Structural Exam · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7044759
19 August 2020
Deficiency Check · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7038170
11 March 2020
Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6877239
9 October 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6789711
10 October 2018
Internal Structural Exam · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6555832
9 November 2017
Administrative Inspection
Administrative · Navigation Center · Activity 6303854
25 October 2017
Administrative Inspection · Deadweight Survey · Examination of Repairs · Construction Oversight · Hull Examination · Plan Review (Other than "T")
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6315714
12 October 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6242630
10 July 2017
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6205698
28 March 2017
Deficiency Check · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6119358
12 October 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6002565
11 May 2016
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5874821
24 March 2016
Deadweight Survey · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5910619
17 February 2016
Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5817154
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 February 2024
Resolved
Two STBD aft handrail stanchions were cracked and required to re-welded.
Action required: 705 - Other - as specified
Resolved 28 February 2024
Resolution: railing has been rewelded.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 December 2023
Resolved
System design and installation must be in accordance with the marine design, installation, operation, and maintenance manual approved for the system by the commandant. MI found disconnected C02 bottle head in ports side CO2 room. Technician called and attended vessel during inspection to connect bottle head. Satisfactory repair conducted during inspection.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 December 2023
Resolution: Corrected during inspection by fires servicing technician.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 21 December 2023
Resolved
A Class bulkheads or decks must be so constructed so they are capable of preventing the passage of smoke and flame for 1 hour. MI discovered split seam on top combing vertical entrance into port side engine room.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 January 2024
Resolved 28 December 2023
Resolution: Cleared. Operator provided photo of weld repair at port engine room entry combing.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 June 2022
Resolved
Id'd extra security strap on the lifefloats which would not have allowed the lifefloats to be released in case of an emergency.
Action required: 10 - Deficiency Rectified
Resolved 3 June 2022
Resolution: Master removed extra strap
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 9 October 2019
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Vessel failed to complete annual inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 October 2019
Resolved 11 October 2019
Resolution: Vessel completed annual COI.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 October 2019
Resolved
Fire extinguishing equipment installed on a vessel in excess of the requirements of §§118.400 and 118.500 must be designed, constructed, installed, and maintained in a manner acceptable to the Commandant. Operator provided unsatisfactory fire servicing report for installed engine room halon systems. When tested by fire servicing personnel and witnessed by MI, port ER 60 second time delay discharged at 48 seconds, and stbd ER 60 second time delay discharged at 126 seconds.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 October 2019
Resolution: Fire servicing performed IAW manufacture manual in presence of MI.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 October 2019
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. Remote closure of the port main engine and generator fuel valves failed to fully close valves.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 October 2019
Resolution: Linkage adjusted and test sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 October 2019
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Days tank sight glasses in both engine rooms were found to be made of plastic tubing and not mechanically protected.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2019
Resolution: Sight glasses removed and tank penetrations plugged.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 October 2019
Resolved
Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required. STBD generator racor filter was found to have plastic bowl not fitted with a flame shield.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2019
Resolution: Fllame shield installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 October 2019
Resolved
Conductors must be protected in accordance with their current carrying capacities. Luggage ventilator fan breaker was found to be 30 amp with 14 awg wire. Circuit is to remain open until removed or 15 amp breaker is installed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 11 October 2019
Resolution: Breaker replaced with 15 amp.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 October 2019
Resolved
Fire extinguishing equipment installed on a vessel in excess of the requirements of §§118.400 and 118.500 must be designed, constructed, installed, and maintained in a manner acceptable to the Commandant. Automatic shutdowns for main engines shall be installed into halon systems.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 21 October 2019
Resolution: Autoshutdowns installed and tested, all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 October 2019
Resolved
Fire extinguishing equipment installed on a vessel in excess of the requirements of §§118.400 and 118.500 must be designed, constructed, installed, and maintained in a manner acceptable to the Commandant. Provide proof of Commandant approval of installed halon systems.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2019
Resolved 21 October 2019
Resolution: Original drawings provided and conducted VT for verification for proper installation.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 9 October 2019
Resolved
Stowed so that when the vessel sinks the survival craft floats free. Life float covers will not allow life floats to float free. Vessel shall not carry passengers with covers over life floats.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 9 October 2019
Resolved 9 October 2019
Resolution: Covers removed for operation.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 9 October 2019
Resolved
Each member of the crew shall participate in at least one abandon ship drill each month. Vessel training records show a 3 month gap in performing man overboard and abandon ship drills.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 October 2019
Resolved 9 October 2019
Resolution: Crew conducted satisfactory drills.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 12 October 2017
Resolved
Prove proper operation of the Port engine room fire damper.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2017
Resolved 12 October 2017
Resolution: Vessel proved proper operation of the port engine room fire damper
Engineering › Bilge Water Management System › Pump
Issued 12 October 2017
Resolved
Prove proper operation of the installed bilge system for the stbd hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2017
Resolved 12 October 2017
Resolution: Vessel proved proper operation of the stbd hull bilge system.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 12 October 2017
Resolved
Properly install all float-free links for all life floats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2017
Resolved 12 October 2017
Resolution: Vessel properly installed all float-free links.
Construction/Loadline › Hull › Hull Plating
Issued 10 July 2017
Resolved
repair fracture flange for stbd sea chest
Action required: 705 - Other - as specified
Due 14 July 2017
Resolved 11 July 2017
Resolution: repaired
Construction/Loadline › Hull › Bottom Plating
Issued 28 March 2017
Resolved
Repair 3 inch crack in port lazarette hull.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 29 March 2017
Resolution: Drill stopping & welding of crack was deemed unsuitable by shipyard. Crack was repaired with a small insert inconsistant with industry guidelines, however MI deemed repair satisfactory by quality of workmanship and final NDT. See Special Note.
Construction/Loadline › Hull › Transverse Frame
Issued 28 March 2017
Resolved
Repair fractured frame in the lazarette of port hull.
Due 29 March 2017
Resolved 29 March 2017
Resolution: Transverse frame was croped and renewed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 June 2016
Resolved
Vessel is restricted to carrying 225 persons onboard, 215 of which may be passengers, per new Stability Letter dated 17 June 2016.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 12 October 2017
Resolution: Vessel was issued new Stability Ltr & updated COI with Total persons allowed; 225 in June 2016.