10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 January 2026
Resolved
Provide a forward masthead and stern navigation light prior to operating during periods of reduced visibility.
Action required: 705 - Other - as specified
Resolved 14 January 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 January 2026
Resolved
Provide a floating waterlight that can be attached to vessel's ring life buoy prior to operating at night.
Action required: 705 - Other - as specified
Resolved 14 January 2026
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 April 2025
Resolved
Provide a means for the pre-engineered fixed gas fire extinguishing system (Fireboy) to automatically shut down all engines that draw intake air from within the space prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 April 2025
Resolved
Provide a suitable strainer having an open area not less than three times the area of the bilge pipe on the bilge pickup in the lazarette.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2025
Resolved 18 April 2025
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 9 April 2024
Resolved
Provide an audible alarm to indicate high water in the Wheel House Space (visual indicator is operational).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 April 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 April 2024
Resolved
Uncover or remark the port fuel shutoff valve location so it is not obscured.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 April 2023
Resolved
Provide 04 additional hand red flare distress signals or 04 hand orange smoke distress signals so the vessel has a total of 06 day and 06 night distress signals.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2023
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 14 April 2023
Resolved
Provide a closure device for each engine room duct and mount or store in the vicinity of the duct.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2023
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 14 April 2023
Resolved
Label the bilge high level alarms to identify the appropriate space for each alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 April 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2023
Resolved
Blank off or otherwise cover the openings on the electrical panel at the operating station to prevent accidental contact with energized circuits.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 April 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2023
Resolved
Remove all dead end wiring from the space under the helm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 May 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2023
Resolved
Install metal supports with chaffing material at 24" intervals on the cable runs in the space below the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 May 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 April 2023
Resolved
Identified termite damage on the center deck beam below the pilot house. Replace during upcoming DDE / ISE.
Action required: 705 - Other - as specified
Resolved 1 May 2023
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 13 April 2022
Resolved
Remove oil from bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2022
Resolved 14 April 2022
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 13 April 2022
Resolved
Amplify Public Address system so that it can be heard from all points on the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 13 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 April 2022
Resolved
Cap or remove unused wiring to old PA system and at the steerying console.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 13 May 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 April 2022
Resolved
Post COI under glass.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 14 April 2022
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 13 April 2022
Resolved
Provide log of monthly EPIRB tests for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2022
Resolved 14 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 January 2021
Resolved
Vessel's audible high-water alarm for the engine room was inoperable. Visual alarm functioning properly. Replace alarm at helm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2021
Resolved 19 January 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 April 2020
Resolved
First aid kit missing multiple items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2020
Resolved 3 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2020
Resolved
Exhaust leak present in tank room. Identify leak and submit repair proposal to OCMI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 April 2020
Resolved 3 June 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 April 2020
Resolved
Lifebuoy retro reflective tape worn beyond compliance.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2020
Resolved 3 June 2020
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 2 April 2020
Resolved
Hydrostatic release expired on EPIRB
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 April 2020
Resolved 3 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 April 2020
Resolved
High Water alarm in Tank void not functioning.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 April 2020
Resolved 3 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 April 2020
Resolved
High Water alarm wiring in Lazarette space wrapped around the hydraulic steering ram post, causing the alarm to be ripped from the deck installation. Repair and properly install high water alarm in space.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 April 2020
Resolved 3 June 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 29 April 2019
Resolved
Vessel voids should be kept dry. Repair/Replace gaskets in deck hatches, replace access cover in engine compartment to keel void and prevent water egress from anchor windless.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2019
Resolved 30 May 2019
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 29 April 2019
Resolved
Repair/Replace Fore and Aft decks. Deck beams have been added in the aft compartment due to original beams being wasted. Fore deck is not currently adequately supported creating possible delamination and deck movement. Submit plan for proposed repair and layout of structural members.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2019
Resolved 29 May 2019
Resolution: replaced both decks
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 April 2019
Resolved
Provide means for automatic generator shutdown with activation of pre-engineered fire fighting system. No use of generator until repaired.
Action required: 705 - Other - as specified
Due 11 April 2019
Resolved 11 April 2019
Resolution: 1 week
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 April 2019
Resolved
Provide means to secure engine room ventilation to create a vapor-tight seal.
Action required: 705 - Other - as specified
Due 11 April 2019
Resolved 29 April 2019
Resolution: one week
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 April 2019
Resolved
Fireboy cylinder is currently overcharge, cylinder must be within normal full range.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 April 2019
Resolved
Bond fuel tank fill line to fuel tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 April 2019
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 4 April 2019
Resolved
Provide and utilize cap on Sewage tank.
Action required: 705 - Other - as specified
Due 11 April 2019
Resolved 12 April 2019
Resolution: TANK IS NOW CAPPED
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 April 2019
Resolved
Label bilge alarm indicators on operating station panel board.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2019
Resolution: labeled
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 April 2019
Resolved
Provide a means to adequately and safely retrieve a man over board. Conduct a man over board drill in the presence of USCG Marine Inspectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 April 2019
Resolution: vessel now has a life sling
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 April 2019
Resolved
Post a donning placard for all versions of life jackets carried on-board.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 4 April 2019
Resolved
Provide a vessel specific emergency instruction list and train crew IAW list.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 April 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 April 2019
Resolved
Post all pages of the COI and stability letter.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2019
Resolution: posted
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 June 2018
Resolved
All machinery spaces must be equipped with fixed gas fire extinghuishing systems. System was deployed to extinguish fire and is no longer ready for use. Ensure system is recharged and functioning in accordance with manufacturer's instructions. Additionally, ensure repairs are made to vessel for damage resulting from vessel fire. Vessel authorized to shift berths to complete repairs after notifying OCMI.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 2 August 2018
Resolved 7 July 2018
Resolution: Vessel replaced fireboy system and made all required repairs to vessel. Sea trials conducted successfully.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 27 February 2018
Resolved
Prove proper operation of Fireboy shutdown and override function for main engines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 February 2018
Resolution: Demonstrated shutdown and override functions for main engines.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 27 February 2018
Resolved
Prove proper operation of Fireboy shutdown function of generator. Vessel is restricted from using generator with passengers on board.
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 28 March 2018
Resolution: Demonstrated shutdown of generator upon discharge of Fireboy.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 February 2018
Resolved
Life ring light lanyard needs to be 3-6 feet.
Action required: 705 - Other - as specified
Resolved 27 February 2018
Resolution: Replaced lanyard with correct length.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 February 2018
Resolved
Renew life ring light battery with one of approved type. Vessel restricted to daylight operations.
Action required: 705 - Other - as specified
Resolved 27 February 2018
Resolution: Replaced battery with correct type.
Lifesaving › Lifefloat › Serviceable
Issued 27 February 2018
Resolved
Make repairs to life floats in accordance with manufacturer's instructions. Vessel restricted to operating no more than 3 miles from shore.
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 28 February 2018
Resolution: Owner opted to remove lifefloats and reduce vessels route.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 24 April 2017
Resolved
Renew/Replace suttlas bearings on port and starboard shafts.
Action required: 705 - Other - as specified
Resolved 27 April 2017
Resolution: Port and STBD bearings replaced.
Engineering › Shafting/Propeller Arrangements › Strut
Issued 24 April 2017
Resolved
Renew/replace intermediate strut for shaft.
Action required: 705 - Other - as specified
Resolved 27 April 2017
Resolution: Strut was repaired, grinded down and re-welded.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 24 April 2017
Resolved
Make collision bulkhead penetrations watertight.
Action required: 705 - Other - as specified
Resolved 27 April 2017
Resolution: Collision bulkhead was made watertight utilizing 5200.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 24 April 2017
Resolved
Conduct pressure test of fuel tank at a pressure of 5psi for a period of 10 minutes. Provide plans to OCMI for replacement or repair proposal for fuel tank.
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 5 January 2018
Resolution: Opened activity #6334084 for construction oversight and installation.
Engineering › Bilge Water Management System › Strainer
Issued 6 December 2016
Resolved
Install suitable strainers on all bilge suctions
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 30 June 2019
Resolution: Vessel now complies with bilge system requirements.
Communications › Radio Communications › VHF Radiotelephone
Issued 6 December 2016
Resolved
Program VHF with MMSI
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 9 January 2017
Resolution: Installed VHF with integrated GPS and programmed MMSI
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 December 2016
Resolved
Install guards in front of both engines
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 9 January 2017
Resolution: Installed guards on both engines
Engineering › Fuel Oil Service System › Suction Strainer
Issued 6 December 2016
Resolved
Install suitable marine type fuel strainers
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 9 January 2017
Resolution: Installed marine grade strainers with flame shield
Engineering › Fuel Oil Service System › Piping
Issued 6 December 2016
Resolved
Make repairs to to port fuel pick up on tank
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 14 December 2016
Resolution: Repaired
Lifesaving › Lifefloat › Serviceable
Issued 6 December 2016
Resolved
Make repairs to lifefloat in accordance with manufacturer's instructions.
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 9 January 2017
Resolution: Made repairs in accordance with manufacture's instructions
Electrical › Lighting (service) › Lighting Fixture
Issued 13 January 2016
Resolved
Masthead light was inoperable during inspection
Action required: 705 - Other - as specified
Due 13 February 2016
Resolved 8 February 2016
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 13 January 2016
Resolved
Vessel's rescue ladder did not have tether to ensure it remained attached to the vessel.
Action required: 705 - Other - as specified
Due 13 February 2016
Resolved 8 February 2016