MAURY USCG vessel records Sign in
← All vessels

GULF STREAM III

GULF STREAM III is a 1979 unclassified. The Coast Guard has recorded 74 inspections since 1984, most recently in January 2010, along with 105 deficiencies — 1 with no resolution recorded — and 2 casualty investigations between 2009 and 2010.

Records from 1984 to 2010. Most recent: inspection, 20 January 2010.

Built
1979
Last inspected
20 January 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE3189
Flag
UNITED STATES
367139760, 367335370 (licence lapsed)
Maury page id
psix-50403

Inspections, by type

…with no type recorded10
…past their stated due date1
Years with a record 27 calendar years (1984–2010)
The 74 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it41 - Regulatory (Subpart C or D), Net Ton
61 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDE3189MMSI 367335370 · expired · compulsorily equipped · granted 5 February 2008, cancelled 14 April 2018 · licensed under a name not among this hull’s recorded names (not shown)
WDD4067MMSI 367139760 · expired · compulsorily equipped · granted 14 September 2006, cancelled 19 November 2016 · licensed under a name not among this hull’s recorded names (not shown)
WBP3318MMSI not assigned · expired · compulsorily equipped · granted 10 December 1997, cancelled 15 March 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GULFSTREAM IV Passenger (Inspected) · MISLE 272015 · 19 January 2010 · activity 3666843EVA MARIE Passenger (Uninspected) · MISLE 395957 · 19 January 2010 · activity 3666843HOOKED UP Passenger (Inspected) · MISLE 878509 · 19 January 2010 · activity 3666843

Inspection history · 74

20 January 2010 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3666717
19 January 2010 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3666843
24 December 2009 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3654909
23 December 2009 Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 3654828
23 December 2009 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3654892
29 April 2009 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3463514
19 March 2009 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3436101
19 February 2009 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3422301
12 January 2009 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3393870
5 December 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3376773
23 September 2008 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3330975
4 April 2008 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3177394
29 November 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3106799
3 May 2007 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2969020
13 September 2006 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2789739
18 October 2005 Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2516341
14 September 2005 COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2488082
27 May 2005 Hull Examination · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2369058
15 April 2005 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2334485
30 September 2004 Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2207742
19 November 2003 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1954151
26 September 2003 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1913119
20 May 2003 Hull Examination · Deficiency Check · Examination of Repairs
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1845929
25 September 2002 Re-Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1677358
12 December 2001 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1477581
19 September 2001 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1362472
6 June 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1467762
26 September 2000 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1435100
22 October 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1132140
20 September 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1413601
8 June 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1427687
3 February 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1473560
9 September 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1467564
18 November 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1108044
8 September 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 787081
23 June 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1111700
1 October 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 832309
12 September 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 955335
12 September 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1186342
23 June 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 878049
27 October 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 866612
27 October 1994 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1176234
12 September 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 865542
19 November 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1447302
29 October 1993 Inclining Experiment
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 848755
5 October 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1154141
10 September 1993 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1143336
22 October 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1265269
7 October 1992 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1268384
24 September 1992 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1250437
22 July 1992 Damage Survey · Examination of Repairs · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 962980
2 July 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 151457
29 October 1991 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1250545
11 September 1991 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1265132
9 September 1991 Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1255534
21 September 1990 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 951360
20 September 1990 Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1224429
28 June 1990 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 930690
6 June 1990 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 920331
6 June 1990 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1261791
18 September 1989 Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 932100
19 January 1989 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 896895
11 January 1989 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 898918
2 November 1988 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1200655
22 September 1988 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1042743
19 October 1987 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1021101
3 June 1987 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1023009
3 June 1987 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1197967
6 March 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1011496
9 October 1986 Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1320058
16 October 1985 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1298101
18 September 1985 Credit Drydock
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 988458
20 May 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 983856
4 October 1984 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1284012

Deficiency record · 105

Construction/Loadline › Hull › Bottom Plating
Issued 5 December 2008 Resolved
Provide a repair plan for water leaks in hull (in vicinity of engine space and rod room).
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 December 2008
Resolved 9 December 2008
Construction/Loadline › Hull › Bottom Plating
Issued 5 December 2008 Resolved
Make proper repairs to leaks in hull in accordance with the approved plan to the satisfaction of an attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2008
Resolved 12 December 2008
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 5 December 2008 Resolved
Obtain new certificate of documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2008
Resolved 12 December 2008
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 5 December 2008 Resolved
Tighten shaft packing as discussed.
Due 9 December 2008
Resolved 9 December 2008
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 December 2008 Resolved
Completed annual inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2008
Resolved 12 December 2008
Documentation › Certificates/Documents › FCC SSL
Issued 5 December 2008 Resolved
Obtain a valid radiotelephony safety certificate.
Due 12 December 2008
Resolved 12 December 2008
Lifesaving › Lifefloat › Markings
Issued 5 December 2008 Resolved
Stencil lifefloat and paddles with vessel name.
Due 12 December 2008
Resolved 12 December 2008
Construction/Loadline › Hull › Bottom Plating
Issued 5 December 2008 No resolution recorded
Conduct monthly inspections (beginning from due date) of all spaces to the satisfaction of an attending marine inspector until further notice.
Due 12 January 2009 — due date passed with no resolution recorded
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 April 2008 Resolved
Prove proper operation of the vessel's bilge high level alarm system to the satisfaction of an attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2008
Resolved 4 April 2008
Lifesaving › Lifefloat › Markings
Issued 29 November 2007 Resolved
Re-stencil vessel name and passenger capacity on lifefloat.
Due 29 November 2007
Resolved 29 November 2007
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 29 November 2007 Resolved
Reconnect lifefloat lights to the lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2007
Resolved 30 November 2007
Lifesaving › Lifefloat › Pendant
Issued 29 November 2007 Resolved
Properly connect port lifefloat line to the pendant of the lifefloat.
Due 29 November 2007
Resolved 30 November 2007
Lifesaving › Lifefloat › Platform
Issued 29 November 2007 Resolved
Install spacers between lifefloats.
Due 14 December 2007
Resolved 19 December 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 November 2007 Resolved
Prove proper operation of starboard navigation light. Vessel is restricted to daylight operations until this requirement is met.
Due 29 November 2007
Resolved 29 November 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 November 2007 Resolved
Prove proper operation of the anchor light.
Due 14 December 2007
Resolved 29 November 2007
Personnel › Training › First Aid/CPR
Issued 29 November 2007 Resolved
Obtain first aid/CPR training for at least 50% of crew.
Due 1 January 2008
Resolved 19 December 2007
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 29 November 2007 Resolved
Replace retroreflective tape on 2 adult lifejackets as discussed.
Due 14 December 2007
Resolved 19 December 2007
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 29 November 2007 Resolved
Tighten shaft seal (port and starboard)
Due 29 November 2007
Resolved 29 November 2007
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 29 November 2007 Resolved
Remove a/c drain pipe from engine room.
Due 14 December 2007
Resolved 19 December 2007
Construction/Loadline › Structures › Deck Plating
Issued 29 November 2007 Resolved
Repair leaks on starboard quarter deck at the gunwale as discussed.
Due 14 December 2007
Resolved 19 December 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 November 2007 Resolved
Make repairs to the visual bilge high level alarm indicators.
Due 14 December 2007
Resolved 19 December 2007
Communications › Radio Communications › EPIRB
Issued 29 November 2007 Resolved
Mark hydrostatic release for EPIRB.
Due 14 December 2007
Resolved 19 December 2007
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 September 2005 Resolved
Provide original Certificate of Documentation onboard vessel.
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 18 October 2005
Operations/Management › Passenger Operations › Safety Orientation
Issued 14 September 2005 Resolved
Provide passenger count onboard and ashore IAW 46 CFR 185.504.
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 18 October 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 14 September 2005 Resolved
Complete Emergency Broadcast Placard.
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 18 October 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 14 September 2005 Resolved
Replace hydrostatic release in way of 406MHz EPIRB prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2005
Communications › Alarms/Indicators › High Water Alarm
Issued 14 September 2005 Resolved
Prove proper operation of bilge high level alarm in way of #1 and #2 compartments prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 September 2005 Resolved
Replace expired first-aid kit items.
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 18 October 2005
Lifesaving › Lifefloat › Paddle
Issued 14 September 2005 Resolved
Lash paddles to all lifefloats in accordance with 46 CFR 180.175(f)(2).
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 15 September 2005
Lifesaving › Lifefloat › Paddle
Issued 14 September 2005 Resolved
Mark lifefloat paddles with vessels name IAW 46 CFR 185.604(g).
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 14 September 2005
Lifesaving › Lifefloat › Painter
Issued 14 September 2005 Resolved
Replace painters in way of all lifefloats IAW 46 CFR 180.175(f)(3).
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 18 October 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 September 2005 Resolved
Provide horizontal rail courses on upper deck so that there is no space greater than 4 inches between courses IAW 46 CFR 177.900(g)(1).
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 18 October 2005
Fire Fighting › Fire Pumps › Suction Valve
Issued 14 September 2005 Resolved
Replace handle in way of fire pump raw water intake.
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 18 October 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 September 2005 Resolved
Provide machinery guard around rotating machinery in way of port engine.
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 18 October 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 September 2005 Resolved
Conduct satisfactory man-overboard drill in the presence of Marine Inspector.
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 18 October 2005
Construction/Loadline › Hull › Transverse Frame
Issued 27 May 2005 Resolved
Drydock worklist item. Make proper repairs to #1 transverse frame, port side, lazerette as indicated by Marine Inspector.
Action required: 705 - Other - as specified
Resolved 31 May 2005
Construction/Loadline › Hull › Transverse Frame
Issued 27 May 2005 Resolved
Drydock worklist item. Make proper repairs to transverse #4 floor frame, lazerette as indicated by Marine Inspector.
Action required: 705 - Other - as specified
Resolved 31 May 2005
Construction/Loadline › Hull › Bracket
Issued 27 May 2005 Resolved
Drydock worklist item. Remove butt block, starboard side, lazerette and make area ready for inspection.
Action required: 705 - Other - as specified
Resolved 31 May 2005
Construction/Loadline › Hull › Stiffener
Issued 27 May 2005 Resolved
Drydock worklist item. Make repairs to frame ends, starboard side, lazerette as indicated by Marine Inspector.
Action required: 705 - Other - as specified
Resolved 31 May 2005
Construction/Loadline › Hull › Strut/Cross Tie
Issued 27 May 2005 Resolved
Drydock worklist item. Make proper repairs to gusset, bottom framing and side shell framing, starboard side fuel tank space, as indicated by Marine Inspector.
Action required: 705 - Other - as specified
Resolved 31 May 2005
Construction/Loadline › Hull › Hull Plating
Issued 27 May 2005 Resolved
Drydock worklist item. Replace wasted planks, port side, aft or submit repair proposal for the same.
Action required: 705 - Other - as specified
Resolved 31 May 2005
Construction/Loadline › Hull › Bottom Plating
Issued 27 May 2005 Resolved
Drydock worklist item. Remove fastenings as indicated by Marine Inspector and make the same available for inspection.
Action required: 705 - Other - as specified
Resolved 27 May 2005
Construction/Loadline › Hull › Hull Plating
Issued 27 May 2005 Resolved
Drydock worklist item. Make ready for inspection plank on port bow indicated by Marine Inspector.
Action required: 705 - Other - as specified
Resolved 27 May 2005
Electrical › Electrical Distribution System (service)
Issued 26 September 2003 Resolved
Install a cover on switchboard panel inside entrance to engineroom. LEGACY COMPONENT DESC: Switchboard Cover
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 October 2003
Resolved 19 November 2003
Resolution: Observed corrected.
Personnel › Certificates/Documents/Licenses
Issued 26 September 2003 Resolved
Provide proof of Marine Radio Operator Permit. LEGACY COMPONENT DESC: FCC Marine Radio Operator Permit
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 October 2003
Resolved 19 November 2003
Resolution: Owner has completed application process and is awaiting permit.
Lifesaving › Lifejacket/PFD (Type I)
Issued 26 September 2003 Resolved
Replace retro-reflective tape on 11 PFDs. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2003
Resolved 19 November 2003
Resolution: Observed corrected.
Lifesaving › Lifejacket/PFD (Type I)
Issued 25 September 2002 Resolved
Replace retro-reflective tape on failed lifejackets. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 October 2002
Resolved 2 October 2002
Resolution: Corrected
Navigation › Collision/Grounding Avoidance
Issued 25 September 2002 Resolved
Replace lenses for port and starboard sidelights. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 October 2002
Resolved 2 October 2002
Resolution: Corrected
Lifesaving › Lifebuoys
Issued 25 September 2002 Resolved
Replace batteries in three waterlights attached to life floats. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 October 2002
Resolved 2 October 2002
Resolution: Corrected
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 25 September 2002 Resolved
Tighten rudder packing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 October 2002
Resolved 2 October 2002
Resolution: Corrected
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 25 September 2002 Resolved
Provide proof of service for fixed fire fighting system prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 October 2002
Resolved 26 September 2002
Resolution: System serviced by Davis Sales & Service.
Electrical › Electric Supply System (service)
Issued 25 September 2002 Resolved
Properly mount batteries and provide battery covers. LEGACY COMPONENT DESC: Battery Installation
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 October 2002
Resolved 23 May 2003
Resolution: Corrected.
Electrical › Electrical Distribution System (service)
Issued 25 September 2002 Resolved
Provide metallic wire supports every 24 inches on horizontal wire runs. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2002
Resolved 23 May 2003
Resolution: Corrected.
Lifesaving
Issued 19 September 2001 Resolved
Properly label forward PFD stowage locker "90 ADULT LIFE PRESERVERS".
Condition: Unknown
Due 3 October 2001
Resolved 12 December 2001
Resolution: PFD stowage locker properly labeled.
Lifesaving
Issued 19 September 2001 Resolved
Renew retro-reflective tape on the 15 person Buoyant Apparatus.
Condition: Unknown
Due 3 October 2001
Resolved 12 December 2001
Resolution: Retro-reflective tape renewed.
Engineering
Issued 19 September 2001 Resolved
Properly wire tachometer for port engine using crimp-type connectors.
Condition: Unknown
Due 3 October 2001
Resolved 12 December 2001
Resolution: Tachometer properly wired.
Lifesaving
Issued 19 September 2001 Resolved
Renew lifeline on ringbuoy with 60 ft. minimum length, polypropalene or equivalent.
Condition: Unknown
Due 3 October 2001
Resolved 12 December 2001
Resolution: Lifeline on ringbuoy renewed.
Construction/Loadline
Issued 19 September 2001 Resolved
Tighten belt on engine driven bilge pump.
Condition: Unknown
Due 3 October 2001
Resolved 12 December 2001
Resolution: Belt tightened and found sat.
Lifesaving
Issued 19 September 2001 Resolved
Properly mark entrance to upper deck with total number (40) of persons allowed.
Condition: Unknown
Due 3 October 2001
Resolved 12 December 2001
Resolution: Ladder to upper deck properly marked.
Construction/Loadline
Issued 19 September 2001 Resolved
Reconnect wire to float switch on bilge pump in rudder room and demonstrateproper automatic operation.
Condition: Unknown
Due 3 October 2001
Resolved 12 December 2001
Resolution: Wire connected and bilge pump tested sat.
Navigation
Issued 19 September 2001 Resolved
Provide all required navigation publications.
Condition: Unknown
Due 3 October 2001
Resolved 12 December 2001
Resolution: Navigation publications obtained.
Lifesaving
Issued 19 September 2001 Resolved
Post Emergency Radio Broadcast Placard.
Condition: Unknown
Due 3 October 2001
Resolved 12 December 2001
Resolution: Emergency Radio Broadcast Placard posted.
Fire Fighting
Issued 26 September 2000 Resolved
Conduct annual service for portable & fixed fire equipment.
Condition: Unknown
Due 30 October 2000
Resolved 3 October 2000
Accommodation/Occupational Safety
Issued 26 September 2000 Resolved
Repair hand rail, stbd side, forward.
Condition: Unknown
Due 30 October 2000
Resolved 19 October 2000
Construction/Loadline
Issued 26 September 2000 Resolved
Replace valve handle on oveboard discharge in steering compt.
Condition: Unknown
Due 30 October 2000
Resolved 3 October 2000
Construction/Loadline
Issued 26 September 2000 Resolved
Repair leaking electric submersible discharge line where it affixes to the overboard valve, fuel tank compt.
Condition: Unknown
Due 30 October 2000
Resolved 3 October 2000
Lifesaving
Issued 26 September 2000 Resolved
Properly connect & stow primary lifesaving appliances. Replace retro on buoyant apparatus.
Condition: Unknown
Due 30 October 2000
Resolved 3 October 2000
Fire Fighting
Issued 20 September 1999 Resolved
Install vent closures for F/F System in engineroom.
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Lifesaving
Issued 20 September 1999 Resolved
Re-stencil 22 person L/F to reflect correct # of passengers (currently stenciled for 25 persons).
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Lifesaving
Issued 20 September 1999 Resolved
Replace ring buoy. Correct by 27SEP99.
Condition: Unknown
Due 27 September 1999
Resolved 22 September 1999
Lifesaving
Issued 20 September 1999 Resolved
Properly affix weak links on all lifefloats. Check to ensure 100' of line on each.
Condition: Unknown
Due 20 September 1999
Resolved 22 September 1999
Lifesaving
Issued 20 September 1999 Resolved
Properly color/mark Distress Signal container.
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Lifesaving
Issued 20 September 1999 Resolved
Get u/w with CG rep to conduct emergency drills.
Condition: Unknown
Due 20 September 1999
Resolved 20 September 1999
Electrical
Issued 20 September 1999 Resolved
Affix wires above EPIRB to prevent entangeling. Complete by 20SEP99.
Condition: Unknown
Due 20 September 1999
Resolved 22 September 1999
Lifesaving
Issued 8 September 1997 Resolved
Repair or renew both 25 person lifefloats and renew lines.
Condition: Unknown
Due 8 September 1997
Resolved 8 September 1997
Lifesaving
Issued 8 September 1997 Resolved
Renew retro-reflective tape on 66 adult PFD's and 13 child PFD's.
Condition: Unknown
Due 8 September 1997
Resolved 8 September 1997
Electrical
Issued 12 September 1996 Resolved
Install belt guard on generator.
Condition: Unknown
Due 19 September 1996
Resolved 1 October 1996
Navigation
Issued 12 September 1996 Resolved
Raise anchor light or relocate buoyant apparatus to allow for proper visibility of light.
Condition: Unknown
Due 19 September 1996
Resolved 1 October 1996
Lifesaving
Issued 12 September 1996 Resolved
Repair or replace 10 adult PFD's. Limited to not more than 145 total persons until corrected.
Condition: Unknown
Due 19 September 1996
Resolved 1 October 1996
Electrical
Issued 12 September 1996 Resolved
Properly wire bilge pump in aft compt.
Condition: Unknown
Due 19 September 1996
Resolved 1 October 1996
Engineering
Issued 12 September 1994 Resolved
Remount the fuel supply valve to the S/S Generator. Valve presently not properly fastened and may cause fuel line to work, become brittle and break.
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Lifesaving
Issued 12 September 1994 Resolved
Seperate child and adult lifejackets with a partition_x001C_ OR_x001C_ stow them in a seperate compartment.
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Fire Fighting
Issued 12 September 1994 Resolved
Replace suction and discharge hoses on hand fire pump with longer ones per discussion with inspector.
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Construction/Loadline
Issued 12 September 1994 Resolved
Replace bilge pump float switch and test operation of bilge pump in fuel tank space.
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Electrical
Issued 10 September 1993 Resolved
Remove imporper 110 volt light fixtures (open bulbs) from stern of vessel.
Condition: Unknown
Due 10 September 1993
Resolved 10 September 1993
Documentation
Issued 10 September 1993 Resolved
Post Certificate of Inspection in passenger area.
Condition: Unknown
Due 10 September 1993
Resolved 10 September 1993
Electrical
Issued 10 September 1993 Resolved
Replace two broken globes on 110 volt deck lights port side just aft of wheelhouse on main deck.
Condition: Unknown
Due 10 September 1993
Resolved 10 September 1993
Lifesaving
Issued 10 September 1993 Resolved
Replace two paddles, each four feet long on each life float.
Condition: Unknown
Due 10 September 1993
Resolved 10 September 1993
Lifesaving
Issued 7 October 1992 Resolved
PROVIDE 3 ADDITIONAL ADULT LIFE PRESERVERS.
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Unknown
Issued 9 September 1991 Resolved
ISSUED 4 CG-835 ITEMS.
Condition: Unknown
Due 11 September 1991
Resolved 17 December 1991
Construction/Loadline
Issued 6 June 1990 Resolved
CREDIT DRYDOCK DUE BY 06DEC91. CONTACK USCG PRIOR TO THIS DATE TO SCHEDULE INSPECTION.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Accommodation/Occupational Safety
Issued 6 June 1990 Resolved
REPAIR ROTTEN STANTIONS (BULWORK) AS FOLLOWS: 2ND FROM STBD & 2ND FROM PORT PORT SIDE 4TH FWD O/STERN
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Accommodation/Occupational Safety
Issued 6 June 1990 Resolved
SEAL E/R VENT PORT SIDE (UNDER SEAT) TO 12" HIGH.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Accommodation/Occupational Safety
Issued 6 June 1990 Resolved
MAKE PERMANENT REPAIRS TO HOLE IN DECK (STBD AFTY 3' FWD OF STERN).
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Accommodation/Occupational Safety
Issued 6 June 1990 Resolved
RENEW E/R VENTS ON STBD SIDE (UNDER SEAT) AND SEAL WATERTIGHT TO 12" HIGH.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Engineering
Issued 2 November 1988 Resolved
REPLACE MISSING FUEL VENT SCREENS
Condition: Unknown
Due 2 November 1988
Resolved 2 November 1988
Accommodation/Occupational Safety
Issued 2 November 1988 Resolved
REWELD HAND RAIL FWD. PORTSIDE
Condition: Unknown
Due 2 November 1988
Resolved 2 November 1988
Lifesaving
Issued 22 September 1988 Resolved
RE-NEW 100-FOOT PAINTER FOR BUOYANT APPARATUS.
Condition: Unknown
Due 22 September 1988
Resolved 22 September 1988
Engineering
Issued 22 September 1988 Resolved
INSTALL GUARD OVER PULLEY FOR HYDRAULIC PUMP ON STARBOARD ENGINE.
Condition: Unknown
Due 22 September 1988
Resolved 22 September 1988
Electrical
Issued 22 September 1988 Resolved
RE-NEW COOLING WATER LINE ELBOW ON INDEPENDENT GENERATOR.
Condition: Unknown
Due 22 September 1988
Resolved 22 September 1988
Engineering
Issued 22 September 1988 Resolved
GRIND AND CLEAN CORROSION FROM PORT FUEL TANK. COAT TANK AND RE-DIRECT DECKVENT FROM DIRECTLY OVER TANK. DEMONSTRATE THAT REMAINING STEEL IS WITHIN REQUIREMENTS.
Condition: Unknown
Due 22 September 1988
Resolved 22 September 1988
Lifesaving
Issued 22 September 1988 Resolved
LABEL ALL BUOYANT APPARATUS WITH PERSONS CAPACITY IN 1-1/2-INCH LETTERS.
Condition: Unknown
Due 22 September 1988
Resolved 22 September 1988
Lifesaving
Issued 22 September 1988 Resolved
PROVIDE ONE ADDITIONAL FLOATING WATER LIGHT FOR BUOYANT APPARATUS.
Condition: Unknown
Due 22 September 1988
Resolved 22 September 1988
Engineering
Issued 19 October 1987 Resolved
INSTALL TEMPERATURE CENSOR/ALARMS IN THE MAIN ENGINE COOLING WATER SYSTEMS.
Condition: Unknown
Due 19 October 1987
Resolved 19 October 1987
Fire Fighting
Issued 19 October 1987 Resolved
REPLACE THE PVC PIPING IN THE FIREMAIN IN THE ENGINE ROOM WITH METALLIC PIPE.
Condition: Unknown
Due 19 October 1987
Resolved 19 October 1987

Casualty record · 2

23 December 2009Routine · role: Acknowledged Pollution Source · activity 3654892
19 January 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3666843
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record