14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 3 July 2025
Resolved
Oil was discovered leaking from the vessel's exhaust into the water. Identify the cause of the leak and enact a repair to the satisfaction of the attending USCG marine inspector.
Cite: 46 CFR 182.200.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 July 2025
Resolution: Transmission cooler was replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 30 October 2024
Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding
the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized
route of the vessel. Windows on the 02 deck are not properly secured. Properly secure windows and notify local OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 14 November 2024
Resolution: Verified Rectified.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 30 October 2024
Resolved
Conduct a test of the generator exhausts’ cooling water warning device in the presence of a USCG marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 14 November 2024
Resolution: Verified Rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 October 2024
Resolved
A vessel’s hull must not carry current as a conductor except for the following systems: Impressed current cathodic protection systems, or Battery systems for engine starting. Reconfigure the starboard batteries’ so they are not connected to the hull.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 14 November 2024
Resolution: Verified Rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 21 November 2023
Resolved
The painter must: Be of at least 100 feet in length, but not less than 3 times the distance between the deck where the life float or buoyant apparatus it serves is stowed and the lowest load waterline of the vessel;
Reattach Life floats to deck with painter and link.
Vessel limited to Lakes Bays Sound.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 November 2023
Resolution: O/O reattached painter lines.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 November 2023
Resolved
Alcohol test swabs were expired, renew and replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2023
Resolved 27 November 2023
Resolution: Alcohol test swabs renewed.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 21 November 2023
Resolved
Each EPIRB must be tested monthly and shall be logged or otherwise documented, as applicable.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 21 November 2023
Resolved 27 November 2023
Resolution: held training with crew and logged test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 November 2023
Resolved
Provide lagging/insulation to hot section of the starboard generator’s exhaust. Area of concern is before cooling water is introduced into exhaust pipe.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 November 2023
Resolution: o/o replaced lagging on starboard generator’s exhaust.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 November 2023
Resolved
Generator frequency meter was found inoperable, make repairs and prove proper operation
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 December 2023
Resolution: Witnessed generator frequency meter operating satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 November 2023
Resolved
Dead ended wires were found in the overhead of the galley-forward/port side/overhead area. Remove wires or properly terminate in a junction box.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 December 2023
Resolution: Dead ended wires removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 August 2022
Resolved
Vessel's steering was inoperable. Identify the cause of the steering failure and repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2022
Resolution: Witnessed satisfactory steering test.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 23 August 2022
Resolved
Vessel's rescue platform has been removed from the vessel and is missing. Vessel is incapable of safely recovering a man-overboard. Install an approved rescue platform or equivalent means of recovering an unconscious person from the water and demonstrate satisfactory operation in the presence of USCG marine inspectors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2022
Resolution: Vessel replaced rescue platform with Jacob's Cradle.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 23 August 2022
Resolved
Vessel only has 03 red hand flares and 03 orange smoke flares. Acquire an additional 03 red hand flares and 03 orange smoke flares for the vessel. Vessel is restricted to a lakes, bays, and sounds route as per its COI until this deficiency is rectified.
Action required: 705 - Other - as specified
Resolved 16 September 2022
Resolution: Vessel acquired additional flares.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 August 2022
Resolved
Vessel's watertight door indicator is inoperable. Repair/replace the watertight door indicator. Until this deficiency is rectified, vessel is required to have a roving watch verify that the vessel's watertight door (between the engine room and galley) is closed while underway once every 30 minutes and log these checks in the vessel's log book.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2022
Resolved 3 October 2022
Resolution: Witnessed satisfactory test.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 August 2022
Resolved
Vessel's alcohol test strips were expired. Provide valid alcohol test strips to the vessel.
Action required: 10 - Deficiency Rectified
Resolved 23 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 August 2022
Resolved
Renew all type 2 SOLAS retro-reflective tape on all buoyant apparatus.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2022
Resolved 16 September 2022
Resolution: Vessel installed new retro tape.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 November 2021
Resolved
STBD generator exhaust pipe found to be severely wasted. Repair wasted area or provide third party report showing condition of exhaust pipe / repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2021
Resolved 23 December 2021
Resolution: Repair proposal recieved; and repairs made.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 November 2021
Resolved
STBD generator engine cooling flex hose found leaking.
Repair, or replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2021
Resolved 24 December 2021
Resolution: Replaced flex hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 November 2021
Resolved
STBD side outboard of generator through hull penetration
flex rubber hose connection made with single hose clamp;
add / install second hose clamp.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2021
Resolved 24 December 2021
Resolution: Installed hose clamp.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 November 2021
Resolved
Electrical switchboard frequency meter not operational;
repair, or replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2021
Resolved 6 April 2022
Resolution: Replaced. Witnessed Operational test; ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 November 2021
Resolved
Switchboard #1 GEN circuit breaker opening has electrical wire crossing opening of switch; re-route electrical wire away from switch opening.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2021
Resolved 23 December 2021
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 November 2021
Resolved
Engine room air compressor electrical junction box cover plate missing; re-install cover.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2021
Resolved 23 December 2021
Resolution: Installed cover.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 November 2021
Resolved
Port generator exhaust muffler unit forward inboard corner leaking; repair leak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2021
Resolved 24 December 2021
Resolution: Repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 November 2021
Resolved
Stairwell to galley left side wall light fixture not operational: repair, or replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2021
Resolved 23 December 2021
Resolution: Repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 November 2021
Resolved
Forward portside crew closet at bulkhead cable penetration missing sealant; add approved sealant.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2021
Resolved 3 March 2022
Resolution: Repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 November 2021
Resolved
Vessel name missing from Bow of vessel; Provide proper marking to Bow of Vessel.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2021
Resolved 3 March 2022
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 22 November 2021
Resolved
Port side aft quarter pexiglass window on main deck missing bottom corner; repair, or replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2021
Resolved 25 April 2022
Resolution: Replaced glass window.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 November 2021
Resolved
Bridge portable FFE service tage expired as of OCT2021; renew servicing tag.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2021
Resolved 23 December 2021
Resolution: Serviced.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 November 2021
Resolved
Bridge aft closet space; SFP protection insulation missing. Re-install.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2021
Resolved 3 March 2022
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 November 2021
Resolved
Bridge aft closet space; 3 electrical cable conductor wires exposed. Remove cables or terminate into a junction box.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2021
Resolved 23 December 2021
Resolution: Repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 November 2021
Resolved
Bridge life jacket storage space: electrical cable conductor wires exposed. Remove cables or terminate into a junction box.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2021
Resolved 23 December 2021
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 19 November 2020
Resolved
Replace broken window on vessel's port quarter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2020
Resolved 30 October 2024
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 19 November 2020
Resolved
Vessel had no records of recorded EPIRB testing, commence monthly testing and log accordingly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2020
Resolved 18 March 2021
Resolution: Received photo of new EPIRB installed onboard the vessel.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 November 2020
Resolved
Provide one of vessel's DSC VHF radios with vessel's MMSI and LAT/LONG. Label that radio "DISTRESS RADIO"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2020
Resolved 25 March 2021
Resolution: Vessel rep sent radio to repair shop and provided pitcure of MMSI with LAT/LONG.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 November 2020
Resolved
Properly secure/mount dimmer switch in electrical box located port side on wheel house.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2020
Resolved 7 January 2021
Resolution: Dimmer switch was mounted in junction box.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 November 2020
Resolved
Label all breakers in wheel house electrical panel with what each circuit breaker feeds.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2020
Resolved 7 January 2021
Resolution: Panel was labeled with circuits.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 19 November 2020
Resolved
Renew expired EPIRB battery, vessel is reduced to less than 3 miles from shore until corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2020
Resolved 18 March 2021
Resolution: Received photo of new EPIRB installed on the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 November 2020
Resolved
Prove proper operation of installed bilge system.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 November 2020
Resolution: Witnessed satisfactory operation of installed bilge system.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 19 November 2020
Resolved
Repair all damaged and faded areas of all life floats in accordance with manufacture and NVIC 2-63.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2020
Resolved 18 March 2021
Resolution: All life floats were taken to manufacture approved repair facility and overhauled.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 19 November 2020
Resolved
Replace broken paddle on lower 22 person life float. Remove zip ties from all life float paddles and provide with means to secure but removable without tools.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2020
Resolved 18 March 2021
Resolution: All life float paddles were renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 19 November 2020
Resolved
Label total person capacity on all life floats and all illegible paddles.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2020
Resolved 18 March 2021
Resolution: All life floats were re-labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 19 November 2020
Resolved
Replace incorrectly sized float free link on forward 22 person life float.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2020
Resolved 18 March 2021
Resolution: Correct float free link was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 November 2019
Resolved
Remove dead-end wires from under galley sink.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2019
Resolved 6 December 2019
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 7 November 2019
Resolved
Secure galley lift station under galley sink.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2019
Resolved 6 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 7 November 2019
Resolved
Properly install oven vent to exhaust hood.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2019
Resolved 6 December 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 November 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2019
Resolved 4 December 2019
Resolution: Received confirmation of test result.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 November 2019
Resolved
Label engine room escape to make escape visible.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2019
Resolved 6 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 November 2019
Resolved
Replace broken outlet cover in bar area on port side.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2019
Resolved 6 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 7 November 2019
Resolved
Repair/replace defective light in chain locker - install light cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2019
Resolved 6 December 2019
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 7 November 2019
Resolved
Provide proof of valid FCC station license.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2019
Resolved 7 January 2020
Resolution: Provided
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 7 November 2019
Resolved
Replace missing bilge valve handle.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 September 2019
Resolved
The port main engine failed without warning resulting in reduced propulsion. Repair to the satisfaction of attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2019
Resolution: Port engine was rebuilt by Cummings Technician. Tested high temperature alarms with Cummings Technician and conducted satisfactory sea trial.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 10 April 2019
Resolved
Clean fwd toilet space to bare metal.
Action required: 705 - Other - as specified
Due 11 April 2019
Resolved 12 April 2019
Resolution: Cleaned
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 4 April 2019
Resolved
Clean steering space to bare metal for inspection.
Action required: 705 - Other - as specified
Due 11 April 2019
Resolved 12 April 2019
Resolution: Cleaned
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 April 2019
Resolved
Provide proof that 5 blade replacement props are approved for use on vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 3 May 2019
Resolution: Vessel rep provided spec sheet and email correspondence from naval architect.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 November 2018
Resolved
Make effective repairs on bilge manafold and prove proper operation.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2018
Resolution: Repaired manafold, tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 November 2018
Resolved
Install shore power available light.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 November 2018
Resolution: Shore power light installed and tested.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 7 November 2018
Resolved
Make repairs on the top of CHT tank top in fwd head.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 November 2018
Resolution: Tank flange and TLI repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 November 2018
Resolved
Renew 01 buoy with 60 ft of line.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2018
Resolution: Replaced RLB and line.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 7 November 2018
Resolved
Renew expired alcohol test strips.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 February 2019
Resolution: Renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 November 2018
Resolved
Install proper weak links on life floats. (Restricted to LBS)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 February 2019
Resolution: Weak link installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 November 2018
Resolved
Prove proper operation of starboard generator meters.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 February 2019
Resolution: Gauges operational and tested.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 8 September 2017
Resolved
Demonstate proper operation of the low lube oil alarms on both MDEs prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 October 2017
Resolved 8 September 2017
Resolution: Demonstated proper operation of the low lube oil alarms on both MDEs prior to carrying passengers.
Engineering › Bilge Water Management System › Pump
Issued 23 August 2017
Resolved
Prove proper operation of primary and secondary bilge pumps
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2017
Lifesaving › Buoyant Apparatus › Serviceable
Issued 23 August 2017
Resolved
Repair 20 person BA prior to carrying more than 30 persons on a Limited Coastwise route.
Action required: 705 - Other - as specified
Resolved 29 September 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 23 August 2017
Resolved
Cover electrical boxes under bridge
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 29 September 2017
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 August 2017
Resolved
Label lifejacket stowage
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 29 September 2017
Lifesaving › Buoyant Apparatus › Serviceable
Issued 23 August 2017
Resolved
Properly stow 20 person buoyant apparatus
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 29 September 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 23 August 2017
Resolved
Provide battery box cover stbd generator
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 29 September 2017
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 23 August 2017
Resolved
Provide FE mounting bracker for main deck bar area
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 29 September 2017
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 23 August 2017
Resolved
Properly stow CO2 cylinders located in the forepeak to prevent movement.
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 29 September 2017
Lifesaving › Lifefloat › Serviceable
Issued 23 August 2017
Resolved
Provide serviceable lifefloats prior to operating on a limitied coastwise route. COI requires 3 for 52 persons.
Action required: 705 - Other - as specified
Due 29 October 2017
Resolved 21 February 2019
Resolution: Replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 5 June 2017
Resolved
The port engine stalled unexpectedly while the vessel was underway with passengers.
Determine the cause of the casualty on the port engine and prove proper operation after repairs are rendered.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2017
Resolution: engine in question had undergone maintenance that replaced a spring in the governor. The replacement spring was under sized allowing the engine to stall when under load. Engine testing was conducted, these test include one "crash stop" and multiple pivots
Engineering › Bilge Water Management System › Pump
Issued 21 November 2016
Resolved
Make effective repairs to the firemain bilge piping and prove proper operation
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2016
Resolution: Repairs made and witnessed proper operation
Electrical › Electric Generation Source (service) › Panelboard
Issued 21 November 2016
Resolved
Provide proper interlock for main electrical panel
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 December 2016
Resolved 30 January 2017
Resolution: Installed proper interlock for main electrical switchboard.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 November 2016
Resolved
Install guard on air compressor belt
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 December 2016
Resolved 3 February 2017
Resolution: Aluminium guard made and installed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 November 2016
Resolved
Install battery cover for port generator
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 December 2016
Resolved 30 January 2017
Resolution: Battery cover for port generator installed.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 21 November 2016
Resolved
Remove electrical hazard from galley electrical panel
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 December 2016
Resolved 30 January 2017
Resolution: Removed electrical hazard from galley
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 21 November 2016
Resolved
Renew floating waterlight on 20 person buoyant appuratus
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 December 2016
Resolved 30 January 2017
Resolution: Floating water light renewed
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 21 November 2016
Resolved
Install cover on galley electrical outlet
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 December 2016
Resolved 30 January 2017
Resolution: The cover on galley electrical outlet was installed.
Electrical › Electric Generation Source (service) › Generator
Issued 15 September 2016
Resolved
Provide cause of generator and make repairs to the satisfaction of Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2016
Resolution: Generator windings rebuilt and tested under load.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 15 September 2016
Resolved
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2016
Resolution: Exhaust leak corrected and proper operation proved to the attending marine inspector.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 August 2016
Resolved
Conduct extensive failure analysis on the cause of the port main engine exhaust failure and provide a detailed report.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2016
Resolution: Cause of casualty was badly corroded piping. Verified by the attending Marine Inspector.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 August 2016
Resolved
Make effective repairs to the port main engine exhaust cooling system and prove proper operation to the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2016
Resolution: Entire piping system renewed and tested.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 23 July 2016
Resolved
Provide a suitable warning device on all engine room machinery where the exhaust cooling systems is seperate from the engine cooling system. The device shall be audible or visual at the operating station.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 13 October 2016
Resolution: Exhaust high temp alarms installed and tested.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 22 July 2016
Resolved
Prove proper operation of the starboard generator after effective repairs have been made
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2016
Resolution: Witnessed proper operation of the generator under full load.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 22 July 2016
Resolved
Make proper repairs to port MDE exhaust fitting
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2016
Resolution: The melted hose was replaced and inspected.
Documentation › Logs/Records › Logbook (official)
Issued 22 July 2016
Resolved
Provide hourly E/R rounds while the vessel is underway and login the vessel's official logbook
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 13 October 2016
Resolution: Record keeping for rounds of engine room no longer needed.