MAURY USCG vessel records Sign in
← All vessels

CELERITY

CELERITY is a 1987 passenger vessel (inspected). The Coast Guard has recorded 54 inspections since 1987, most recently in August 2020, along with 28 deficiencies.

Records from 1987 to 2020. Most recent: inspection, 1 August 2020.

Built
1987
Last inspected
1 August 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

284676
Flag
UNITED STATES
—
Maury page id
psix-284676

Inspections, by type

…with no type recorded8
Years with a record 30 calendar years (1987–2020)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it5 - Simplified, Gross Ton
5 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ORIOLE Passenger (Inspected) · MISLE 1109717 · 28 April 2016 · activity 5870685CLIPPER CITY Passenger (Inspected) · MISLE 256329 · 13 October 2006 · activity 2800427ISLAND VOYAGER Passenger (Inspected) · MISLE 279394 · 13 October 2006 · activity 2800427REDHEAD Passenger (Inspected) · MISLE 361745 · 13 October 2006 · activity 2800427

Inspection history · 54

1 August 2020 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7069429
19 June 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6718992
11 June 2018 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6442329
21 February 2017 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6091779
29 April 2016 DAPI Audit · Examination of Repairs · Annual Inspection · Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5865552
28 April 2016 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5870685
8 January 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5793772
30 May 2014 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4883877
31 January 2011 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3936587
8 July 2009 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3533046
16 June 2008 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3238900
2 April 2007 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2878530
14 October 2006 Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2800419
13 October 2006 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2800427
10 June 2006 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2747787
3 February 2006 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2578601
11 April 2005 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2331357
25 October 2004 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2227923
9 April 2004 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2040781
15 March 2004 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2024576
12 March 2004 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2023502
23 April 2003 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1819019
12 April 2002 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1603926
25 June 2001 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1068464
21 June 2001 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1408759
9 February 2001 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1422012
5 May 2000 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1453781
11 August 1999 Excursion Permit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1114960
27 July 1999 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 774577
14 April 1999 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1125942
2 June 1998 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1128314
24 November 1997 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1109800
30 May 1997 Deficiency Check · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1460966
23 April 1996 Hull Examination · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1455365
31 March 1995 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1148269
26 January 1995 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1141959
18 February 1994 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1166625
23 November 1993 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1164127
9 November 1993 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 851461
7 December 1992 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1132805
25 November 1992 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1138390
29 September 1992 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 951819
17 June 1992 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 232183
24 March 1992 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 947712
25 June 1991 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 910698
29 October 1990 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 921341
28 September 1990 Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1236234
12 September 1989 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1033008
7 April 1989 Hull Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1035495
15 April 1988 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1338677
27 November 1987 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1313169
13 October 1987 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1012384
4 September 1987 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1324394
2 September 1987 Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1317414

Deficiency record · 28

Construction/Loadline › Structures › Superstructure
Issued 29 April 2016 Resolved
Portside house and railing damaged due to collision with SPV Oriole. Submit repair proposal to attending marine inspector. Repai proposal must be received, reviewed and approved prior to start of repairs. Vessel is not to be used with passengers for hire until repairs are completed and examined by attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2016
Resolved 19 May 2016
Resolution: Attended vessel and cleared above deficiency.
Engineering › Bilge Water Management System › Pump
Issued 8 July 2009 Resolved
Port bilge pump switch does not indicate operation at steering station. Repair/replace.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2009
Resolved 8 July 2009
Resolution: Switch fixed prior to departure.
Engineering › Bilge Water Management System › Pump
Issued 2 April 2007 Resolved
Replace (2) Port/Stbd aft bilge pumps with U/L listed approved pumps.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2007
Resolved 17 May 2007
Resolution: Attended vessel at Fells Point, Baltimore, MD. Cleared above deficiency.
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 April 2007 Resolved
Properly label STBD/Port forward bilge pumps on console indicators.
Action required: 705 - Other - as specified
Due 10 April 2007
Resolved 17 May 2007
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 2 April 2007 Resolved
Pre-engineered fire (Halon) system expired. Have serviced by qualified technician.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2007
Resolved 6 April 2007
Resolution: Received report from O/Op showing above system had been serviced.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 April 2007 Resolved
Stbd Aft rub rail loose & hanging . Repair to original condition. Repair prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2007
Resolved 17 May 2007
Resolution: Attended vessel at Fells Point, Baltimore, MD. Cleared above deficiency.
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 25 October 2004 Resolved
Vessel restricted to carry 49 passengers until operating company can show vessel meets type II subdivision requirements.
Due 26 October 2004
Resolved 15 June 2018
Resolution: Amended COI
Operations/Management › Passenger Operations
Issued 12 March 2004 Resolved
Provide a written plan to record the number of passengers onboard at the departure of each vessel in accordance with 46 CFR 185.504. This record must be ashore and available to the Coast Guard upon request.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 March 2004
Resolved 12 March 2004
Lifesaving
Issued 21 June 2001 Resolved
REPLACE RING LIFE BUOY DUE TO A CHUNK MISSING FROM THE BUOY.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Construction/Loadline
Issued 21 June 2001 Resolved
INSTALL HIGH WATER BILGE ALARM.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Engineering
Issued 5 May 2000 Resolved
REHANG STBD WATER COOLING HOSES.
Condition: Unknown
Due 5 June 2000
Resolved 27 June 2000
Lifesaving
Issued 5 May 2000 Resolved
REPAIR OR REPLACE FIRST AID KIT BOX, UPDATE KIT.
Condition: Unknown
Due 5 June 2000
Resolved 27 June 2000
Fire Fighting
Issued 14 April 1999 Resolved
PROVIDE PROPER FIRE EXTINGUISHER MOUNTING BRACKETS FOR BII EXTINGUISHER.
Condition: Unknown
Due 14 April 1999
Resolved 14 April 1999
Lifesaving
Issued 14 April 1999 Resolved
REPLACE 3 ADULT LIFE JACKETS.
Condition: Unknown
Due 14 May 1999
Resolved 23 April 1999
Engineering
Issued 30 May 1997 Resolved
FUEL VENT SCREEN INSUFFICIENT. MESH HOLES TOO LARGE, NOT 30X30.
Condition: Unknown
Due 2 June 1997
Resolved 10 June 1997
Lifesaving
Issued 30 May 1997 Resolved
4 ADULT PFDS REJECTED. MATERIAL WASTED/TORN DUE TO UV EXPOSURE.
Condition: Unknown
Due 2 June 1997
Resolved 10 June 1997
Engineering
Issued 31 March 1995 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 31 March 1995
Resolved 31 March 1995
Construction/Loadline
Issued 31 March 1995 Resolved
plastic hatch covers broken due to age
Condition: Unknown
Due 31 March 1995
Resolved 31 March 1995
Fire Fighting
Issued 9 November 1993 Resolved
REPLACE AND MOUNT 1 B1 AND 2BII
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Lifesaving
Issued 9 November 1993 Resolved
PFD STORAGE BOX MISSING LABEL.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Electrical
Issued 9 November 1993 Resolved
REPLACE BATTERY BOX COVER.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Construction/Loadline
Issued 29 September 1992 Resolved
REPAIR TURN OF DECK PORT SIDE FORWARD USING APPROVED MATERIALS.
Condition: Unknown
Due 29 September 1992
Resolved 29 September 1992
Accommodation/Occupational Safety
Issued 29 September 1992 Resolved
REPAIR HAND RAIL PORT SIDE FORWARD USING BACKING PLATES IN WAY OF THREE OUTBOARD DECK MOUNTING PLATES.
Condition: Unknown
Due 29 September 1992
Resolved 29 September 1992
Electrical
Issued 28 September 1990 Resolved
MAKE OPERATIONAL THE STARBOARD BILGE PUMP FROM THE OPERATORS CONSOLE.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Documentation
Issued 4 September 1987 Resolved
PROVIDE FCC STATION LICENSE FOR THE VESSEL.
Condition: Unknown
Due 4 September 1987
Resolved 4 September 1987
Documentation
Issued 2 September 1987 Resolved
INSTALL STATE REGISTRATION NUMBERS.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Documentation
Issued 2 September 1987 Resolved
PROVIDE EVIDENCE OF LICENSED OPERATORS FOR VESSEL.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Fire Fighting
Issued 2 September 1987 Resolved
PROVE OPERATION OF FIRE PUMP
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.