Records from 2001 to 2018. Most recent: inspection, 18 September 2018.
Inspection history · 20
18 September 2018
ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6542410
18 January 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6340008
5 May 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6139409
29 September 2016
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6012256
28 September 2016
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6011895
26 December 2015
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5787208
26 December 2015
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5787352
6 December 2015
ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5773716
13 March 2014
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4814992
23 March 2009
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3438410
2 February 2009
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3404123
16 June 2008
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3239081
30 October 2005
Random ISPS/MTSA/PSC
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2526209
26 October 2005
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2523155
28 April 2005
Type not recorded
No type recorded · GROUP HAMPTON ROADS · USCG East District (CGD-E) · Activity 2345600
26 April 2005
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2342949
7 March 2005
ISPS II Exam · Ballast Water Examination · NPV Safety Exam · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2304796
11 January 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1985028
3 February 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1739270
5 August 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 292432
Documentation › Logs/Records › Garbage Recordkeeping
Issued 2 February 2009
Resolved
2120: Garbage is not consistent w/ the garbage mgmt manual/plan and garbage separation is not being followed. Contents in garbage containers were mixed; found extra containers on ship which are not listed in the plan i.e. batteries & other. Electrical ENG is collecting batteries & fluorescent lights, but he is not mentioned in the garbage plan as a key player.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 28 February 2009
Resolved 19 March 2009
Resolution: Corrected to the satisfaction of Class.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 February 2009
Resolved
0371: Medical kit in the Galley and ENG control room were not adequately supplied or in sanitary condition. There were missing items in the medical kit and supplies such as gauze and cotton were exposed and dirty. Reference World Heath Organization & ILO 147.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 February 2009
Resolved 19 March 2009
Resolution: Corrected to the satisfaction of Class.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 2 February 2009
Resolved
2055: Ballast Water settlement is not being recorded as per Section 9, table 8A of the BWM Plan. Trng has not been conducted as per Section 7. Last trng was conducted on 18OCT2007.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 February 2009
Resolved 19 March 2009
Resolution: Corrected to the satisfaction of Class.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 2 February 2009
Resolved
0700: The following items have compromised A/O boundaries. 1) Entrance door to A/C room was warped, there was a crack on the left top corner hinge, and door would not close completely. 2) Several holes were found around laundry room bulkhead. 3) Wires above vent to deck workshop & wire leading into the accommodation. The crew was aware of deficiencies, but have not reported per SMS.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 February 2009
Resolved 19 March 2009
Resolution: Corrected to the satisfaction of Class.
Electrical › Electric Supply System (service) › Cable
Issued 2 February 2009
Resolved
0950: Ground straps are missing or broken on the main deck electrical power line and the conduit line leading into the junction box by cargo hold #3 & #4 are cracked allowing water to enter the box. Also Company needs to provide documentation for electrical matting around switchboards and power panels. Discussed with Master and [name withheld] per SMS.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 February 2009
Resolved 19 March 2009
Resolution: Corrected to the satisfaction of Class.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 2 February 2009
Resolved
0900: Approx. 20 oil drums in the Boatswain's storage are leaking and are not on dunnage or secured properly. Saw dust has been used to clean up excess oil which is now saturated with oil causing a fire/safety hazard. The crew is aware of hazard, but has not taken any corrective action.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 February 2009
Resolved 19 March 2009
Resolution: Corrected to the satisfaction of Class.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 2 February 2009
Resolved
0936: Non slip surface hand rails or guide wires have not been installed in the steering flat between the engine room door and steering unit.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 February 2009
Resolved 19 March 2009
Resolution: Corrected to the satisfaction of Class.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 2 February 2009
Resolved
1500: When putting a voyage plan together, the under keel clearance and time dedicated between position checks needs to be established as per ship's SMS 7.1.1.5.2.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 February 2009
Resolved 19 March 2009
Resolution: Corrected to the satisfaction of Class.
Navigation › Piloting/Steering › Gyro Compass
Issued 27 October 2005
Resolved
Vessel was issued a LOD on 26OCT05 to enter the Port of Corpus Christi to deviate from the requirements of 33CFR164.35(d), maintaining a properly operating gyrocompass.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2005
Resolution: Received tech report via fax confirming the vessels gyrocompass is operating properly 29OCT05.