Records from 1988 to 2026. Most recent: inspection, 1 July 2026.
Inspection history · 71
1 July 2026
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8449614
1 April 2025
COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8103059
19 March 2025
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8102276
9 December 2024
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8152055
9 July 2024
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7954157
1 March 2023
In-Service Inspection · Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7643897
12 January 2023
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7620598
24 March 2022
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7576660
20 April 2021
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7179013
19 March 2020
Administrative Inspection · MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6928863
23 May 2019
DAPI Audit · MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6696424
30 May 2018
DAPI Audit · MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6435827
11 October 2017
Examination of Repairs · Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6293117
7 June 2017
MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6173235
26 May 2016
MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5887507
24 March 2015
Deficiency Check · COI Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5078058
2 July 2014
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4892311
23 May 2014
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4857165
28 November 2012
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4485582
23 October 2012
Deficiency Check · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4465979
20 April 2012
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4302032
27 March 2012
MTSA Verification · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4263669
13 January 2012
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4224220
3 November 2011
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4181633
22 July 2010
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3802489
1 April 2010
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3704917
15 April 2009
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3453258
26 March 2009
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3448036
17 October 2008
MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3348357
30 April 2008
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3195784
17 April 2008
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3186366
9 April 2008
Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3181082
15 November 2007
Hull Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3128824
26 September 2007
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3071379
17 September 2007
MTSA Verification · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3060630
2 July 2007
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2980895
29 March 2007
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2898146
29 March 2007
MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2898168
28 March 2006
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2599490
27 April 2005
MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2347505
27 April 2005
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2353823
21 April 2005
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2339972
20 April 2005
COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2337480
20 April 2005
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2345835
30 March 2004
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2033832
27 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1995413
15 April 2003
Periodic Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1774731
12 December 2002
Hull Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1719731
25 March 2002
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1597348
28 March 2001
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1471252
27 March 2000
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1442985
14 April 1999
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 790971
24 March 1999
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1450254
27 March 1998
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1392899
24 December 1997
Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1398815
28 March 1997
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1422830
22 January 1997
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1099690
4 April 1996
Deficiency Check · Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1079116
11 April 1995
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1157126
5 April 1994
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1167065
13 April 1993
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1149312
14 January 1993
Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 826751
7 September 1992
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 220549
24 April 1992
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 957213
6 May 1991
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1231658
16 April 1991
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1234797
23 April 1990
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1222322
15 June 1989
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1342138
4 May 1989
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1346838
2 March 1989
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1194716
12 May 1988
Initial Certification · Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1349565
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 July 2026
No resolution recorded
Owner failed to have vessel inspected for its 2026 annual inspection and is now 90 day past due and has invalidated the Certificate of Inspection. Passenger vessels subject to subchapter K may not be operated without having a valid U.S. Coast Guard Certificate of Inspection on board. Vessel shall not operate with passengers while the COI is invalidated. Rectify the vessel inspection is accordance with 46 CFR 115.100.
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 March 2025
Resolved
Owner failed to schedule and submit application for COI renewal. Current COI in invalid and vessel is not authorized to carry passenger for hire. A certificate of inspection is valid for 5 years for all other vessels. Owner shall submit application for inspection CG 3752 and receive inspection prior to departure prior to movement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2025
Resolution: Conducted COI inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 July 2024
Resolved
Missing Life Buoy on second deck and Life Buoy on main deck has names faded, dry rot line and deteriorated reflective tape. Failure for ring buoys to be in compliance with 46 CFR 117.70. Provide new Life Ring Buoy on 2nd deck and make repairs to the one on main deck to the satisfaction of the attending Coast Guard inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 August 2024
Resolution: Inspected Life Buoy and two were replaced with new rings and associated equipment.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 July 2024
Resolved
Two fire hoses was missing spanner wrench and one had a plastic nozzle and is required to have brass nozzle. Failure to comply with fire hose and nozzle requirements. Provide two spanner wrenches and one brass nozzle to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2024
Resolved 19 August 2024
Resolution: Spanner wrench and brass nozzle replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 July 2024
Resolved
Generator starter is not operable and company is using a non approved starter attached to solenoid. Failure of vessel generator to be in compliance with 46 CFR 120.320. Make repairs to the satisfaction of the attending Coast Guard marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2024
Resolved 19 August 2024
Resolution: Starter replaced and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 July 2024
Resolved
Fuel tank is leaking at the J 1942 double braided hose or ball valve. Failure to be in compliance with 46 CFR 199.45. Make repairs to the satisfaction of the attending Coast Guard inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2024
Resolved 19 August 2024
Resolution: Fuel Valve replaced.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 May 2023
Resolved
Two emergency exit doors missing Exit signs. All escape hatches and other emergency exits used as a means of escape must be marked on both sides. Provide emergency exit signs to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 18 May 2023
Resolution: Emergency Exit signs installed
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 1 May 2023
Resolved
Vessel did not have sufficient emergency instructions. The master and crew of a vessel will be familiar with the content of and have mounted at the operating station emergency instructions the actions taken in the event of fire, flooding, heavy weather or man overboard conditions. Provide to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2023
Resolved 18 May 2023
Resolution: Emergecny Instructions posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 January 2023
Resolved
Vessel did not receive its scheduled drydock November 2022. The owner or managing operator shall make a vessel available for drydock examinations, internal structural examinations, and underwater surveys required by 46 CFR 115.600. Vessel shall rectify deficiencies prior to movement and carry passengers to the satisfaction of the Coast Guard Marine inspector. Vessel may proceed from Queen City Riverboats to McGinnis drydock.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 May 2023
Resolution: Drydock inspection complete.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 April 2021
Resolved
Vessel Fuel transfer pump is leaking oil from gaskets and seals. The general construction of vessel shall be such as to minimize fire hazards. Repair all leaks of fuel oil from gaskets and seals on fuel oil pump. Make repairs to the satisfaction of the attending Coast Guard inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2021
Resolution: Fuel pump has been removed from system and the bow thruster has been taken out of service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 April 2021
Resolved
The cooling system on the generator has been altered and metallic pipes have been removed and flexible hose has been added that does not fit properly or loose and others show ware that compromise the integrity of the system. Double hose clamping is required on each end of the hose where practicable except that one hose clamp can be used if the pipe ends are expanded or beaded to provide positive stop against slippage. Have certified marine mechanic repair altered cooling system to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2021
Resolved 5 October 2021
Resolution: Cooling system has been satisfactory repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 April 2021
Resolved
The two 24 volt batteries for the generator are not secured in battery boxes and the shut off switch is fabricated and not marine grade. A 110 outlet power cord is spliced and connected into engine block and ship’s crew had no knowledge of its purpose or how it got there. Acid batteries shall be located in a tray of lead or other suitable material resistant to deteriorating action by electrolytes. Obtain suitable battery tray and obtain and install new battery shut out switch to the satisfaction of the attending Coast Guard Marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2021
Resolved 5 October 2021
Resolution: Battery system has been satisfactory repaird.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 April 2021
Resolved
Vessel had one life jacket with a hole in it and missing one more. An adult life jacket must be provided for each person carried on board a vessel. Replace two adult life jackets to the satisfaction of the attending Coast Guard Marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 5 October 2021
Resolution: New Life jacket brought onboard.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 23 May 2019
Resolved
The base of the stanchions that support the 2nd deck canopy show signs of deterioration. Determine the extent of deterioration and devise a repair proposal to the satisfaction of a USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 19 June 2019
Resolution: Welded sleeve on bottom of stanchion to re-enforce area.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 May 2019
Resolved
Electrical equipment exposed to the weather must be watertight. Repair or replace all electrical receptacles that are missing covers.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 19 June 2019
Resolution: Replaced covers on outlets.
Construction/Loadline › Hull › Side Shell
Issued 26 May 2016
Resolved
Wasted metal around bar sink drain pipe that penetrates port side shell in
generator space must be permanently repaired at next dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2017
Resolved 11 October 2017
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 26 May 2016
Resolved
Replace retro reflective tape on 10 PFDs identified.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 June 2016
Resolved 14 June 2016
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 24 March 2015
Resolved
Vessels current posted senior deckhand list is from 2013. Several employees are no longer with the company and some have been added. Vessel is to provide an updated senior deckhand list.
Action required: 705 - Other - as specified
Due 24 April 2015
Resolved 16 April 2015
Resolution: Company updated and posted an updated senior deckhand list.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 24 March 2015
Resolved
Vessels ring bouy lifeline is worn. Vessel to replace the lifeline.
Action required: 705 - Other - as specified
Due 24 April 2015
Resolved 16 April 2015
Resolution: replaced lifeline attached to ring bouy
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 May 2014
Resolved
Replace the wasted and worn life line in way of the life ring buoy on the main deck, port side forward in accordance with 46 CFR 180.70(c).
Action required: 705 - Other - as specified
Due 23 June 2014
Resolved 2 July 2014
Resolution: Life line was replaced in way of the life ring buoy and was found satisfactory.
Engineering › Fuel Oil Service System › Gauge
Issued 23 October 2012
Resolved
Prior to next fueling operation, contact the local Coast Guard Marine Inspector to be in attendance. While inspecting void #4, inspectors observed a sorbent pad full of diesel fuel on the deck. The structural integrity of the fuel tank looked good but was unable to determine the location of the leak. The leak was probably coming from the fuel level indicator or at the base of the fuel fill pipe.
Action required: 705 - Other - as specified
Due 1 April 2013
Resolved 2 May 2013
Resolution: Area around the fuel level gauge was inspected, foud to be sealed and no evidence of further leakage.
Electrical › Electric Supply System (service) › Battery Charger
Issued 23 October 2012
Resolved
Properly mount 12 volt battery charger located in the machinery space and ensure the battery charge is hard wired into the vessels electrical system on its own designated circuit.
Action required: 705 - Other - as specified
Due 23 November 2012
Resolved 28 November 2012
Resolution: 12 Volt battery charger was properly mounted and secured. Charger was not hard wired into a circuit and will be addressed at next annual inspection.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 October 2012
Resolved
Remove all non-marine grade wiring located in the machinery space and replace with marine grade wiring.
Action required: 705 - Other - as specified
Due 1 April 2013
Resolved 2 May 2013
Resolution: All nonmarine grade wiring was replaced with suitable marine grade wiring.
Construction/Loadline › Penetrations › Pipe Flange
Issued 23 October 2012
Resolved
Properly seal the PVC pipe penetration overhead located in the #6 void leading to the sink above deck in the female head.
Action required: 705 - Other - as specified
Due 23 November 2012
Resolved 28 November 2012
Resolution: PVC pipe penetration was sealed using an epoxy sealant in the female head. Advised vessel representative to put sealant on the interior penetration in void #6.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 October 2012
Resolved
Replace the battery in way of the floating water light for the life ring buoy located on the main deck, port side.
Action required: 705 - Other - as specified
Due 23 November 2012
Resolved 28 November 2012
Resolution: Battery was replaced in floating waterlight and tested satisfactory.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 October 2012
Resolved
Remove all non-marine approved extension cords and surge suppressors throughout the vessel.
Action required: 705 - Other - as specified
Due 1 April 2013
Resolved 2 May 2013
Resolution: All extension cords were removed and equipment was hard wired into the vessels electrical system.
Operations/Management › Drills/Instruction › Fire
Issued 27 March 2012
Resolved
Ensure all emergency drills, including fire and man overboard drills are conducted every month and logged or otherwise documented in accordance with 46 CFR 122.520(b)(1) and 46 CFR 122.524(b). Requirement was corrected on the spot and documented for historical purposes.
Due 28 March 2012
Resolved 27 March 2012
Resolution: Corrected on the spot and documented for historical purposes.
Documentation › Certificates/Documents › Stability Letter
Issued 27 March 2012
Resolved
Post vessels stability letter under glass or suitable transparent material at the operating station and ensure all pages of the stability letter are visible.
Action required: 705 - Other - as specified
Due 27 April 2012
Resolved 20 April 2012
Resolution: All pages of the stability letter were posted and visible.
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 March 2012
Resolved
Demonstrate proper operation of the high level alarm servicing Void #2 to the satisfaction of an attending Coast Guard Marine Inspector and prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 April 2012
Resolved 29 March 2012
Resolution: Tested satisfactory operation of the high water alarm in void #2.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 March 2012
Resolved
Replace all expired medication s in the first aid kit and ensure the first aid kit has all the required contents in accordance with 33 CFR 160.041.
Action required: 705 - Other - as specified
Due 27 April 2012
Resolved 20 April 2012
Resolution: All expired meds were replaced and the contents of the first aid kit met 46 CFR 160.041.
Fire Fighting › Fire Pumps › Pressure
Issued 27 March 2012
Resolved
Demonstrate proper operation of the fire pump and ensure adequate pressure to the satisfaction of an attending Coast Guard Marine Inspector and prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 April 2012
Resolved 27 March 2012
Resolution: Master cleaned out strainer and fire pump was tested satisfactory.
Engineering › Fuel Oil Service System › Valve
Issued 27 March 2012
Resolved
Make necessary repairs to the emergency fuel shut off valves and demonstrate proper operation of the same to the satisfaction of an attending Coast Guard Marine Inspector prior to carrying passengers.
Action required: 705 - Other - as specified
Due 27 April 2012
Resolved 29 March 2012
Resolution: Emergency fuel shut off valve was repaired and tested satisfactory.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 27 March 2012
Resolved
Recover and properly dispose of excess engine oil collected in the bilge in the engine room of the attending tow vessel, QUEEN CITY.
Action required: 705 - Other - as specified
Due 27 April 2012
Resolved 20 April 2012
Resolution: All oil collecting in the bilge was removed and bilges were clean.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 March 2012
Resolved
Make repairs to broken light fixtures on the upper deck, the first at the top of the stairwell, port side and to the shattered light fixture located at the canopy, center line forward.
Action required: 705 - Other - as specified
Due 27 April 2012
Resolved 20 April 2012
Resolution: All light fixtures were repaired.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 27 March 2012
Resolved
Provide a cover to the junction box located in the engine room in way of the thruster pump. Ensure all twist type lug nuts are properly secured to prevent loosening and secured in the closed junction box.
Action required: 705 - Other - as specified
Due 27 April 2012
Resolved 20 April 2012
Resolution: All spliced wires were properly secured and placed in a junction box.
Stability › Incline Test › General
Issued 2 November 2011
Resolved
Provide proof that the vessel is in compliance with the new AAWPP as required in the guidance in CG-543 Policy Letter 11-03 dated April 8, 2011. If the operator is unable to certify compliance through one of the methods outlined in enclosure 1 of the Policy Letter, the total passengers will be reduced to 178 with total persons onboard reduced to 181.
Action required: 705 - Other - as specified
Due 1 December 2011
Resolved 1 December 2011
Resolution: Passengers were reduced in accordance with CG-543 Policy Letter 11-03.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 1 April 2010
Resolved
Replace the missing outlet covers on all electrical outlets.
Condition: Improper/Lack of Maintenance
Due 2 May 2010
Resolved 29 April 2010
Resolution: All outside outlets had new covers on them.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 April 2010
Resolved
Replace missing ring buoy light from the bow of the vessel.
Condition: Improper/Lack of Maintenance
Due 2 May 2010
Resolved 1 April 2010
Resolution: Corrected before completion of inspection.
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 March 2009
Resolved
Procure battery cover for bow thruster battery and batterys in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2009
Resolved 15 April 2009
Resolution: Cover for Battery box installed.
Fire Fighting › Nozzles › Type
Issued 26 March 2009
Resolved
replace brass fixed stream nozzel with approved nozzel on main deck fire station.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 April 2009
Resolved 15 April 2009
Resolution: Brass nozzels replaced with approved nozzels.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 April 2008
Resolved
Re-label life jacket storage area, area freshly painted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2008
Resolved 26 March 2009
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 9 April 2008
Resolved
Replace missing child size life jacket
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 May 2008
Resolved 17 April 2008
Resolution: Not Required
Lifesaving › Lifebuoys › Serviceable
Issued 9 April 2008
Resolved
Replace worn and punctured lifebuoy.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 May 2008
Resolved 26 March 2009
Documentation › Logs/Records › MIS Form
Issued 9 April 2008
Resolved
Show proff of MIS submission and Consortium contract
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 May 2008
Resolved 17 April 2008
Resolution: Not Required.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 29 March 2007
Resolved
Place donning instructions and number of life jackets on upper deck life jacket lockers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2007
Resolved 17 September 2007
Engineering › Diesel Engine (auxiliary) › Crankshaft
Issued 29 March 2007
Resolved
Install guard over belts on front of engine.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2007
Resolved 17 September 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 29 March 2007
Resolved
Properly install emergency light in engine room.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2007
Resolved 17 September 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 29 March 2007
Resolved
Properly install junction box cover for bilge pump in # 2 void.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2007
Resolved 17 September 2007
Deck/Cargo › Holds/Tanks › Cargo Tank Drainage
Issued 29 March 2007
Resolved
Remove excess water from # 2 void.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2007
Resolved 17 September 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 28 March 2006
Resolved
Prove proper operation of "E" light on starboard side main deck.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 20 April 2005
Resolved
Repair "E" light in generator room, prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2005
Resolved 27 April 2005
Resolution: Replaced battery in E light.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 April 2005
Resolved
Install floating light and line on ring buoy.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2005
Resolved 27 April 2005
Resolution: New line was attached to light.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 April 2005
Resolved
COI expired 27 MAR 05, vessel operated on 1, 2, 4, 6, 7, 9, 15, 16, 17, 18, 19 APR 05. COTP LOW will be issued.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 April 2005
Resolved 20 April 2005
Resolution: Vessel inspected, temporary COI issued.
Operations/Management › Drills/Instruction
Issued 30 March 2004
Resolved
Conduct fire and abandon ship drills with new crewmembers in accordance with 46 CFR 185.420 prior to carrying passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2004
Resolved 5 April 2004
Resolution: Drills conducted and logged.
Navigation
Issued 30 March 2004
Resolved
Provide current copies of navigation publications in accordance with 46 CFR 184.420.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2004
Resolution: All publications onboard.
Electrical › Lighting (emergency)
Issued 30 March 2004
Resolved
Repair or replace emergency light on starboard side main deck and prove proper operation in accordance with 46 CFR 183.432. LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2004
Resolution: Light repaired.
Construction/Loadline › Markings
Issued 30 March 2004
Resolved
Properly identify draft markings in accordance with 46 CFR 185.602 on both port and starboard sides. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2004
Resolution: Draft marks painted.
Construction/Loadline
Issued 24 March 1999
Resolved
INSTALL #2 COMPT AUTOMATIC BILGE PUMP OPERATION ALARM AS REQUIRED BY 46CFR182.530.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Construction/Loadline
Issued 24 March 1999
Resolved
INSTALL BILGE HIGH LEVEL ALARM IN #2 COMPT MEETING THE REQUIREMENTS OF 46CFR182.530.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Construction/Loadline
Issued 24 March 1999
Resolved
INSTALL BILGE HIGH LEVEL ALARM IN #5 COMPT MEETING THE REQUIREMENTS OF 46CFR182.530.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Fire Fighting
Issued 4 April 1996
Resolved
INSTALL A FLAME SCREEN VENT CAP TO SEWAGE SYSTEM HOLDING TANK.
Condition: Unknown
Due 11 April 1996
Resolved 26 April 1996
Lifesaving
Issued 4 April 1996
Resolved
CONDUCT SATISFACTORY UNDERWAY DRILLS NLT 05MAY96.
Condition: Unknown
Due 5 May 1996
Resolved 26 April 1996
Lifesaving
Issued 4 April 1996
Resolved
PROVIDE ONE ADDITIONAL CHILD SIZE PFD SO AS TO MAKE THE TOTAL NUMBER OF CHILD SIZE PFD'S 24. CARRIAGE OF PERSONS WEIGHING LESS THAN 90 LBS IS LIMITED TO 23 UNTIL PROPER PFD IS PROVIDED
Condition: Unknown
Due 11 April 1996
Resolved 26 April 1996
Lifesaving
Issued 4 April 1996
Resolved
DEMONSTRATE SATISFACTORY OPERATION OF RING BUOY LIGHT TO A COAST GUARD MARINE INSPECTOR. VESSEL IS RESTRICTED TO DAYLIGHT ONLY OPERATIONS UNTIL LIGHT IS REPAIRED/REPLACED.
Condition: Unknown
Due 11 April 1996
Resolved 26 April 1996
Lifesaving
Issued 11 April 1995
Resolved
PRIOR TO CARRYING PASSENGERS COMPLETE SATISFACTORY UNDERWAY MAN-OVERBOARD DRILLS.
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Documentation
Issued 5 April 1994
Resolved
PROVIDE EVIDENCE THAT ALL VESSEL CREWMEMBERS HAVE HAD A PRE-EMPLOYMENT DRUGTEST AND ARE ENROLLED IN A RANDOM DRUG TEST PROGRAM IN ACCORDANCE WITH 46 CFR, PART 16.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Construction/Loadline
Issued 5 April 1994
Resolved
MAKE OPERABLE NO. 2 VOID COMPARTMENT LOVETT BILGE PUMP FLOAT SWITCH.
Condition: Unknown
Due 5 May 1994
Resolved 26 April 1994
Documentation
Issued 5 April 1994
Resolved
PROVIDE VALID FIRST-AID AND CPR CERTIFICATES FOR DESIGNATED SENIOR DECKHANDTHOMAS CAMPBELL.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Fire Fighting
Issued 5 April 1994
Resolved
SECURE BOTH PORTABLE FIRE EXTINGUISHERS IN MOUNTING BRACKETS LOCATED ON THEM/V QUEEN CITY.
Condition: Unknown
Due 5 May 1994
Resolved 26 April 1994
Accommodation/Occupational Safety
Issued 5 April 1994
Resolved
REPAIR LEAKING WATER SUPPLY LINE TO MEN'S URINAL.
Condition: Unknown
Due 5 May 1994
Resolved 26 April 1994
Documentation
Issued 13 April 1993
Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION PRIOR TO VESSEL OPERATION, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 1 May 1993
Resolved 19 April 1993
Engineering
Issued 13 April 1993
Resolved
ON M/V QUEEN CITY, INSTALL SAFETY GUARD OVER MAIN PROPELLER SHAFT NOT_x001C_ LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 1 May 1993
Resolved 19 April 1993
Electrical
Issued 13 April 1993
Resolved
SECURE SERVICE GENERATOR FUEL SUPPLY AND RETURN LINE FLEX HOSES NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 1 May 1993
Resolved 19 April 1993
Construction/Loadline
Issued 13 April 1993
Resolved
ON M/V QUEEN CITY, INSTALL A BILGE ALARM WITH WARNING LIGHT IN PILOTHOUSE, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 1 May 1993
Resolved 19 April 1993
Electrical
Issued 13 April 1993
Resolved
CHANGE ALL 20-AMP LIGHTING CIRCUIT BREAKERS TO 15-AMP OR LESS, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 1 May 1993
Resolved 19 April 1993
Electrical
Issued 13 April 1993
Resolved
REPAIR AND PROVE SATISFACTORY OPERATION OF PORT EMERGENCY LIGHTING FIXTURE NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 1 May 1993
Resolved 19 April 1993
Construction/Loadline
Issued 14 January 1993
Resolved
MARK HOME PORT OR HAILING PORT ON STERN, FOUR (4) INCHES IN HEIGHT OR LARGER, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 14 January 1993
Resolved 14 January 1993
Lifesaving
Issued 24 April 1992
Resolved
DEMONSTRATE SATISFACTORY COMMUNICATIONS WITH BOW WATCH DURING MAN-OVERBOARDDRILL PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 24 April 1992
Resolved 29 April 1992
Lifesaving
Issued 24 April 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 April 1992
Resolved 29 April 1992
Electrical
Issued 24 April 1992
Resolved
REPAIR STARBOARD EMERGENCY LIGHT PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 24 April 1992
Resolved 29 April 1992
Lifesaving
Issued 24 April 1992
Resolved
MARK UPPER DECK LIFE PRESERVER CONTAINERS WITH NUMBER AND TYPE OF LIFE PRESERVERS STOWED THEREIN PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 24 April 1992
Resolved 29 April 1992
Engineering
Issued 24 April 1992
Resolved
MARK EMERGENCY FUEL SHUT-OFF CONTROL LOCATION PRIOR TO CARRYING PASSENGERS,BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 24 April 1992
Resolved 29 April 1992
Electrical
Issued 16 April 1991
Resolved
REPLACE PLASTIC FUEL (RETURN) LINE ON SERVICE GENERATOR WITH COPPER TUBING OR ACCEPTABLE FIRE RETARDANT HOSE NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 16 April 1991
Resolved 16 April 1991
Navigation
Issued 16 April 1991
Resolved
ON PUSHBOAT QUEEN CITY, SEPARATE AMBER TOWING LIGHTS VERTICALLY BY AT LEASTONE METER NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 16 April 1991
Resolved 16 April 1991
Navigation
Issued 16 April 1991
Resolved
ON PUSHBOAT QUEEN CITY, INSTALL COTTER KEYS OR OTHER SUITABLE LOCKING DEVICE AT EACH STEERING ARM JOINT PIN NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 16 April 1991
Resolved 16 April 1991
Documentation
Issued 4 May 1989
Resolved
POST A COPY OF THE STABLITY LETTER ON THE VESSEL.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Construction/Loadline
Issued 4 May 1989
Resolved
REMOVE INACCURATE DRAFT MARKS FROM BOTH SIDES OF THE HULL.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Electrical
Issued 4 May 1989
Resolved
REPLACE BURNED-OUT BULB IN EMERGENCY LIGHT FIXTURE, PORT SIDE FORWARD.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Fire Fighting
Issued 4 May 1989
Resolved
PERFORM ANNUAL SERVICING OF ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Navigation
Issued 4 May 1989
Resolved
PROVIDE SCREENING FOR THE SIDELIGHTS TO REPLACE THE SCREENS COVERED BY THE NEWLY-INSTALLED CANVAS BELOW THE HANDRAILS.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Construction/Loadline
Issued 12 May 1988
Resolved
COMPLETE THE DESIGN AND INSTALLATION OF THE PLANNED BOW THRUSTERS.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Electrical
Issued 12 May 1988
Resolved
PROVIDE DOCUMENTATION TO PROVE THAT ALL ON BOARD FLEXIBLE FUEL LINES(HOSES)ARE APPROVED FOR USE ABOARD USCG INSPECTED VESSELS.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Construction/Loadline
Issued 12 May 1988
Resolved
COMPLETE THE INSTALLATION OF THE OVERHEAD INSULATION IN THE ENGINE ROOM.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Construction/Loadline
Issued 12 May 1988
Resolved
MAKE NECESSARY ARRANGEMENTS TO PROVIDE FOR FORMAL ADMEASUREMENT OF THE VESSEL.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Construction/Loadline
Issued 12 May 1988
Resolved
SUBMIT NECESSARY DRAWINGS AND CALCULATIONS TO THE MARINE SAFETY CENTER FOR EVALUATION OF STABILITY.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988