Records from 1995 to 2024. Most recent: inspection, 9 December 2024.
Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 23
9 December 2024
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8152055
27 March 2024
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7885671
4 May 2023
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7684454
13 October 2022
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7576629
1 March 2022
Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7419802
14 December 2021
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7369030
20 April 2021
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7179686
16 July 2020
Initial Certification · Re-Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7007947
26 May 2016
Spot Check (Safety) · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5888423
26 May 2016
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5909633
23 May 2014
Spot Check (Safety)
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4857171
2 May 2013
Spot Check (Safety)
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4579644
2 May 2013
Deficiency Check · Administration
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4605952
28 October 2011
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4177849
24 June 2010
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3775314
29 April 2010
Industry Initiated Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3732410
28 March 2006
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2611296
8 November 2005
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2530993
8 November 2005
MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2667498
25 May 2005
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2377963
20 April 2005
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2339798
27 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2080188
5 August 1995
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 78012
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 27 March 2024
Resolved
The vessel representative reported a temporary patch over a hole in the vessels hull stopping the ingress of water. The cognizant OCMI may require review of a vessels watertight integrity. Maintain daily inspection of the vessel watertight integrity. Provide written repair proposal. If the owner cannot maintain the towing vessel to be in compliance with sub-chapter M at all times the Certificate of Inspection must be withdrawn.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 April 2024
Resolved 21 June 2024
Resolution: Vessel being placed in laid up status.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 1 March 2022
Resolved
Vessel does not have adequate rails or hands grabs on the periphery of main deck. Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails.
Provide rails or equivalent protection on the periphery of vessel to the satisfaction of the attending Coast Guard marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 24 March 2022
Resolution: Rails installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 December 2021
Resolved
Life rings on port and starboard side were missing vessel stenciling and water light on starboard side. towing vessel of at least 26 feet, but less than 79 feet, in length must carry a minimum of two lifebuoys located on opposite sides of the vessel where personnel are normally present. Lifebuoys on port in starboard side shall be in accordance with 46 CFR 141.360 to the satisfaction of the attending Coast Guard Marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2022
Resolution: Satisfactory corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 December 2021
Resolved
Engine gauges in the pilot house are not in working order or mislabeled. Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: Main engine, low lubricating oil pressure, Main engine high cooling water temperature,
Auxiliary generator engine low lubricating oil pressure,
Auxiliary generator engine high cooling water temperature, High bilge levels, Low hydraulic steering
Low fuel level, if fitted with a day tank. Alarms must
Be visible and audible at each operating station. The
alarm located at the operating station may be a summary alarm; if the alarm at the operating station is a summary alarm, the specific alarm condition must be indicated at the machinery or bilge location. Repair or replace alarms in accordance with 46 CFR 143.230 to the satisfaction of the attending Coast Guard marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2022
Resolved 13 October 2022
Resolution: Verfied Guages are labled and proper working order
08 - Alarms › N/A - No Subsystem › General alarm
Issued 14 December 2021
Resolved
Vessel does not have general alarm or public address system that has audible and visual indication in the engine room for emergencies. Each towing vessel must be fitted with a general alarm that:(1)Is activated at each operating station and can notify persons onboard in the event of an emergency:(2) Is capable of notifying persons in any accommodation, work space, and the engine room:(3) Has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light that is identified with a sign that reads: “Attention General Alarm - When Alarm Sounds or Flashes Go to Your Station”. A public-address (PA) system or other means of alerting all persons on the towing vessel may be used in lieu of the general alarm in paragraph (b) of this section if the system meets the requirements of paragrahs(2) and (3) of this section. Install general
alarm to the satisfaction of the attending Coast Guard
marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2022
Resolved 24 March 2022
Resolution: Satisfactory corrected
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 December 2021
Resolved
Vessel did not have records for towing gear. The results of the inspections required by 33 CFR 164.76 must be documented in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel. A record of the type, size, and service of each towline, face wire, and spring line, used to make the towing vessel fast to her tow, must be available to the Coast Guard or third-party auditor for review. The following minimum information is required in the record: The dates when examinations were performed, the identification of each item of towing gear examined, and the name(s) of the person(s) conducting the examinations. Create towing gear record to the satisfaction of the attending Coast Guard marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2022
Resolved 24 March 2022
Resolution: Satisfactory corrected
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 April 2021
Resolved
Vessels 160-B Semi Portable fire extinguisher gauge is in the red indicating the bottle is empty. A towing vessel that is certificated on a rivers rout must be equipped with an approved B-V/160B semi portable fire extinguisher system to protect the engine room. Have 160-B semi portable fire extinguisher serviced or obtain new one to the satisfaction of the attending Coast Guard Marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 July 2021
Resolution: B 160 had been serviced and in working order.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 April 2021
Resolved
Vessel rep reported the generator was overheating and unable to provide load to ships services. Piping systems and tanks exposed to the outside of hull must be made of metal and maintained in a leak free condition. Have certified marine mechanic identify why generator is overheating and verify the integrity of the cooling system, that the keel coolers are not leaking fluid into bilge or river to the satisfaction of the attending Coast Guard Marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2022
Resolution: Satisfactory corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 April 2021
Resolved
Vessels engine room bilge had excessive oil and water that did not appear from any known source. According to
ship’s crew bilges were clean and dry three days
earlier. No person may intentional drain oil or hazardous materials into the bilge of a towing vessel from any source. Have bilges pumped dry to a satisfactory holding tank/facility, cleaned and identify sources of oil and water. Notify the attending Coast Guard Marine inspector once leaking source is located/identified. Make repairs to the satisfaction of the attending Coast Guard Marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2021
Resolution: Bilges were pumped dry.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 September 2020
Resolved
Steering gear hydraulic gauge is showing no indication of pressure and steering gear is making a grinding metallic noise. Each towing vessel equipped with rudder must have a means to monitor and control the position of the rudder at each operating station. Replace hydraulic gauge and identify source of grinding metallic noise on steering gear and make satisfactory repairs to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2020
Resolved 15 October 2020
Resolution: Witnessed satisfactory repair of steering gear.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 August 2020
Resolved
Owner created a fuel gauge using platsic hose and wood that was non approved design alteration to fuel system.
Action required: 10 - Deficiency Rectified
Resolved 6 August 2020
Resolution: Owner removed plactic fuel gauge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 July 2020
Resolved
Generator has significant oil leak in the vacinity of exhaust manifold. All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid. Repair oil leak to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2020
Resolved 6 August 2020
Resolution: Observed satisfactory repair of oil leak.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 July 2020
Resolved
Vessels 160 B fire extinguisher gauge was in the red indicating the semi portable extinguisher had been discharged or had not been serviced. A towing vessel that is Certificated for rivers must have an approved 160-B semi-portable fire-extinguishing system to protect the engine room. Service 160-B semi-portable fire-extinguishing system in accordance with 46 CFR 142.240(2) to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 July 2020
Resolution: Provided evidence that extinguisher was properly serviced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 July 2020
Resolved
Vessels generator governor stuck during inspection and had over speed. Master shut down generator by pulling the fuel shutout valve.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 July 2020
Resolution: Demonstrated proper operation of ship's generator.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 July 2020
Resolved
Vessel does not have installed high bilge level alarms. Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention for high bilge levels. Install high bilge levels alarm. Alarm must me audible and visible at the operating station to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 July 2020
Resolution: Installed bilge high level alarms.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 July 2020
Resolved
Vessel did not have required bilge pump for dewatering. There must be an installed or portable bilge pump for emergency dewatering. Any portable pump must have sufficient hose length and pumping capability. All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended backflooding through bilge piping. Install bilge pump to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 July 2020
Resolution: Vessel properly equipped with portable dewatering pump.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 July 2020
Resolved
Vessel does not have installed low hydraulic steering levels alarm. Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention for low hydraulic steering levels alarm. Alarm must me audible and visible at the operating station. Install low hydraulic steering levels alarm to the satisfaction of the attending Coast Guard Marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 6 August 2020
Resolution: Observed installed low hydraulic steering levels alarm.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 July 2020
Resolved
Vessel did not have an installed Auxiliary generator engine high cooling water temperature alarm. Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention on the Auxiliary generator engine high cooling water temperature. The alarm must be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm; if the alarm at the operating station is a summary alarm, the specific alarm condition must be indicated at the machinery or bilge location. Install alarm to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 6 August 2020
Resolution: Observed installed alarms.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 July 2020
Resolved
Life jackets did not have whistle or light and name. Each life jacket must have a life jacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the life jacket. (2) Each life jacket must have a whistle firmly secured by a cord to the lifejacket. Provide life jackets in accordance with 46 CFR 141.340 to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 6 August 2020
Resolution: Life jacket whistle and lights installed on three PFD's.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 July 2020
Resolved
Vessel did not have required first aid kit. Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Provide first aid kit to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2020
Resolved 15 September 2020
Resolution: First Aid kit placed onbaord.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 July 2020
Resolved
Vessel search light was not operational. Towing vessels must be equipped with a Search light, controllable from the vessel's operating station and capable of illuminating objects at a distance of at least two times the length of the tow. Make search light operational to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 24 July 2020
Resolution: Confirmed search light is opperational.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 July 2020
Resolved
Owner could not provide provide health and safety plan. No later than July 22, 2019, the owner or managing operator must implement a health and safety plan. The health and safety plan must document compliance with this part and include record keeping procedures. Training must be repeated annually and may be conducted over time in modules covering specific topics. Provide health and safety plan and training in accordance with 46 CFR 140.515 to the Satisfaction of the attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2020
Resolved 8 October 2020
Resolution: Received satisfactory health and safety plan.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 July 2020
Resolved
Vessels handrail on main deck are not suitable for
holding/grabbing while transiting alongside of vsl.
Rails or equivalent protection must be installed near
the periphery of all decks accessible to crew.
In areas where space limitations make deck rails
impractical, such as at narrow catwalks in way of
deck-house side. Handrails may be acceptable. Install handrails suitable for grabbing/holding while transiting maindeck sides to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 24 July 2020
Resolution: Installed suitable handrail.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 16 July 2020
Resolved
Ventilation for aft void on stern was holed and wasted. Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. Renew ventilation to original to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 24 July 2020
Resolution: Cropped and renewed ventilation piping
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 July 2020
Resolved
Window was broke on the port side engine room. Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Repair window in the engine room to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 24 July 2020
Resolution: New window was installed
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 July 2020
Resolved
Vessel did not have an approved fire detection system. Fire-detection systems. Each towing vessel must have a fire-detection system installed to detect engine room fires. Each detector, control panel, remote indicator panel, and fire alarm are approved by the Commandant under approval series 161.002 or listed by a NRTL as set
Install to the satisfaction of the Coast Guard inspector
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2020
Resolved 12 November 2020
Resolution: Received documenation from NICET IV scanned into documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 July 2020
Resolved
Lifebuoy did not have required life line and water light was missing two screw that if was submerged in water the light would fill with water. In addition a second life ring is required 37ft ITV. At least one lifebuoy must have a lifeline, secured around the body of the lifebuoy. A towing vessel of at least 26 feet, but less than 79 feet, in length must carry a minimum of two lifebuoys located on opposite sides of the vessel where personnel are normally present. Acquire life line and Lifebuoy and repair water light to the satisfaction of the attending Coast Guard Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2020
Resolved 6 August 2020
Resolution: Observed satisfactory water light and life line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 July 2020
Resolved
Owner installed a non approved alteration to the original fuel system using a nonmetallic flexible hose that is not of suitable material for a sight glass gauge. New installation that are not replacement in kind must comply with the requirements in subpart C of this part. Remove unapproved rubber hose sight glass to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 10 - Deficiency Rectified
Due 6 August 2020
Resolved 6 August 2020