SHANI

SHANI is a 1988 freight ship. The Coast Guard has recorded 5 inspections since 2016, most recently in September 2021, along with 67 deficiencies and 6 operational controls.

Records from 2016 to 2021. Most recent: inspection, 24 September 2021.

Built
1988
Last inspected
24 September 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

8700838
5IM291
313430
Flag
TANZANIA
Maury page id
psix-313430

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 3 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it1726 - Convention (Subpart B), Net Ton
3384 - Dead Weight, Ton
4944 - Displacement, Ton
2566 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

24 September 2021 Loadline Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7318171
23 October 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6567054
3 October 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6553714
5 August 2018 Deficiency Check · In-Service Inspection · Ballast Water Examination · ISPS II Exam · PI Safety Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6558333
21 March 2016 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5837172

Deficiency record · 67

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 April 2019 Resolved
13104- AN EFFICIENT BILGE PUMPING SYSTEM SHALL BE PROVIDED, CAPABLE OF PUMPING FROM AND DRAINING ANY WATERTIGHT COMPARTMENT OTHER THAN A SPACE PERMANENTLY APPROPRIATED FOR THE CARRIAGE OF FRESH WATER, WATER BALLAST, OIL FUEL OR LIQUID CARGO AND FOR WHICH OTHER EFFICIENT MEANS OF PUMPING ARE PROVIDED, UNDER ALL PRACTICAL CONDITIONS. EFFICIENT MEANS SHALL BE PROVIDED FOR DRAINING WATER FROM INSULATED HOLDS. PSCO OBSERVED AN INOPERABLE BILGE PUMP SYSTEM DUE TO REMOVAL OF THE BILGE PUMP AND ASSOCIATED PIPING. 74 SOLAS (2004)CH II-1/REG 21.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 April 2019 Resolved
02105- STEERING GEAR CONTROL SHALL BE PROVIDED WHERE THE MAIN STEERING GEAR IS ARRANGED WITH TWO INDEPENDENT CONTROL SYSTEMS, BOTH OPERABLE FROM THE BRIDGE. PSCO OBSERVED THAT NEITHER THE STEERING WHEEL NOR THE STEERING LEVER WERE WORKING IN FOLLOW-UP OR NON-FOLLOW-UP MODE AT THE CONNING POSITION. 74 SOLAS (2004)CH II-1 /REG 29.7.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 16 April 2019 Resolved
08103- THERE SHALL BE NO LESS THAN TWO SOURCES OF POWER SUPPLY FOR THE ELECTRICAL EQUIPMENT USED IN THE OPERATION OF THE FIRE DETECTION AND THE FIRE ALARM SYSTEM, ONE OF WHICH SHALL BE AN EMERGENCY SOURCE. PSCO OBSERVED THE FIRE ALARM PANEL, LOCATED ON THE NAVIGATION BRIDGE, WAS POWERED THROUGH A POWER OUTLET WHICH WAS NOT CONNECTED TO THE EMERGENCY POWER SUPPLY AND WAS NOT RECEIVING ALL ALARMS TESTED. 74 SOLAS (1997)CH II-2 /REG 13.1.1.3
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 April 2019 Resolved
99101- THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM TO THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO OBSERVED SEA CHEST BOLTS WERE CORRODED OR MISSING. 74 SOLAS (2004)CH I-1 /REG 11.1
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 16 April 2019 Resolved
07114- MEANS SHALL BE PROVIDED WHEREBY NORMAL OPERATION OF PROPULSION MACHINERY CAN BE SUSTAINED OR RESTORED EVEN THOUGH ONE OF THE ESSENTIAL AUXILIARIES BECOMES INOPERATIVE. SPECIAL CONSIDERATION SHALL BE GIVEN TO THE MALFUNCTIONING OF THE FUEL OIL SUPPLY SYSTEMS FOR BOILERS OR ENGINES. PSCO OBSERVED FUEL AND LUBE OIL SHUTOFF VALVES DISCONNECTED AND INOPERABLE. 74 SOLAS (2004) CH II-1/REG 26.3.4
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 April 2019 Resolved
07199- INTERNAL COMBUSTION ENGINES OF 2,250 KW AND ABOVE OR HAVING CYLINDERS OF MORE THAN 300 MM BORE SHALL BE PROVIDED WITH CRANKCASE OIL MIST DETECTORS OR ENGINE BEARING TEMPERATURE MONITORS OR EQUIVALENT DEVICES. PSCO OBSERVED OIL MIST DETECTION INOPERABLE. 74 SOLAS (2004)CH II-1/REG 47.2
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 April 2019 Resolved
07105- STAIRWAYS AND LIFT TRUNKS WHICH PENETRATE MORE THAN A SINGLE DECK SHALL BE SURROUNDED BY AT LEAST ``A-0'' CLASS DIVISIONS AND BE PROTECTED BY SELF-CLOSING DOORS AT ALL LEVELS. PSCO OBSERVED SHORE TIE CABLE COMING FORM THE PIER THROUGH THE HOUSE AND INTO THE ENGINE ROOM AND CONTROL ROOM, THUS PREVENTING DOOR CLOSURE AND VOIDING ALL FIRE BOUNDARIES. 74 SOLAS (1997) CH II-2 /REG 46.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 April 2019 Resolved
07105- DOORS REQUIRED TO BE SELF-CLOSING SHALL NOT BE FITTED WITH HOLD-BACK HOOKS. PSCO OBSERVED SEVERAL SELF-CLOSING DOORS LATCHED OPEN OR MISSING IN THE ENGINE ROOM AND THROUGHOUT THE MAIN HOUSE TO ALLOW SHORE TIE CABLE TO BE CONNECTED TO THE MAIN SWITCHBOARD. 74 SOLAS (1997) CH II-2 /REG 30.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 April 2019 Resolved
07105- THE CONSTRUCTION OF ALL DOORS AND DOOR FRAMES IN “A” CLASS DIVISION, WITH THE MEANS OF SECURING THEM WHEN CLOSED SHALL PROVIDE RESISTANCE TO FIRE AS WELL AS TO THE PASSAGE OF SMOKE AND FLAME. PSCO OBSERVED EMERGENCY ESCAPE DOORS THAT WERE RUSTED THROUGH. 74 SOLAS (1997) CH II-2 /REG 30.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 16 April 2019 Resolved
07122- FIRE CONTROL PLANS SHALL BE KEPT UP TO DATE, ANY ALTERNATIONS BEING RECORDED THEREON AS SOON AS POSSIBLE. PSCO OBSERVED THAT THE POSTED FIRE CONTROL PLAN DID NOT ACCURATELY REPRESENT SHIP'S CURRENT FIRE CONTROL ARRANGEMENTS. 74 SOLAS (1997) CH II-2 /REG 21.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 April 2019 Resolved
13108- MEANS SHALL BE PROVIDED WHEREBY NORMAL OPERATION OF PROPULSION MACHINERY CAN BE SUSTAINED OR RESTORED EVEN THOUGH ONE OF THE ESSENTIAL AUXILIARIES BECOMES INOPERATIVE. SPECIAL CONSIDERATION SHALL BE GIVEN TO THE MALFUNCTIONING OF THE FUEL OIL SUPPLY SYSTEMS FOR BOILERS OR ENGINES. PSCO OBSERVED FUEL OIL SHUTOFF VALVES WERE DISCONNECTED AND NO MAINTENANCE WERE PERFORMED TO KEEP THEM OPERATIONAL. 74 SOLAS (2004) CH II-1 /REG 26.3.4
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 April 2019 Resolved
13101- THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. PSCO OBSERVED MAIN ENGINE OIL PUMPS INOPERABLE. 74 SOLAS (2004) CH II-1 /REG 26.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 April 2019 Resolved
09298- CYLINDERS MUST ALWAYS BE SECURED AND, WHEN NOT IN USE, THEY MUST BE STOWED IN A RACK IN AN UPRIGHT POSITION, WITH THE VALVE PROTECTION CAP IN PLACE. PSCO OBSERVED MULTIPLE OXYGEN AND ACETYLENE CYLINDERS STORED ON THE MAIN DECK VIA RATCHET STRAPS. 46 CFR 147.60(b)(1)
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
09 - Working and Living Conditions › 092 - Working Conditions › Entry dangerous spaces
Issued 16 April 2019 Resolved
09221- LOCKERS OR HOUSINGS MUST BE VENTED TO THE OPEN AIR NEAR THE TOP AND BOTTOM FOR POSITIVE CIRCULATION OF VAPORS. PSCO OBSERVED THAT THE WELDER STORE ROOM WAS FILLED WITH CYLINDERS AND THE SPACE DID NOT PROVIDE ADEQUATE VENTILATION FOR GAS CYLINDERS. 46 CFR 147.60(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 April 2019 Resolved
13199- THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. PSCO OBSERVED WELDED PIPE INTENDED TO FEED MAIN ENGINE COOLING SYSTEM FROM FIRE MAIN WITH UNAPPROVED REPAIRS. 74 SOLAS (2004) CH II-1 /REG 26.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 April 2019 Resolved
02108- THE RATING OR APPROPRIATE SETTING OF THE OVERLOAD PROTECTIVE DEVICE FOR EACH CIRCUIT SHALL BE PERMANENTLY INDICATED AT THE LOCATION OF THE PROTECTIVE DEVICE. PSCO OBSERVED FUSES ON SWITCH BOARD DIDN’T MATCH PLACARDS. 74 SOLAS (2004) CH II-1 /REG 45.6.2
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 16 April 2019 Resolved
08104- ANY MAIN AND AUXILIARY STEERING CONTROL SYSTEM OPERABLE FROM THE NAVIGATION BRIDGE SHALL IN THE EVENT OF A FAILURE OF ELECTRICAL POWER SUPPLY TO THE CONTROL SYSTEM, AN AUDIBLE AND VISUAL ALARM SHALL BE GIVEN ON THE NAVIGATION BRIDGE. PSCO OBSERVED THAT THE STEERING ALARM PANEL DID NOT PROVIDE CORRECT VISUAL NOR AUDIBLE ALARM. 74 SOLAS (2004) CH II-1 /REG 29.8.4
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 April 2019 Resolved
11129- EVERY LIFERAFT SHALL BE STOWED SO THE LIFERAFT FLOATS FREE AND, IF INFLATABLE, INFLATES AUTOMATICALLY WHEN THE SHIP SINKS. PSCO OBSERVED LIFERAFT HYDROSTATIC RELEASE WAS IMPROPERLY INSTALLED. 74 SOLAS (1997) CH III /REG 29
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 April 2019 Resolved
02108- THE SAFETY OF CREW AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. PSCO OBSERVED EXPOSED WIRES THROUGH WASTED CABLE RUNS ON DECK. 74 SOLAS (1997) CH II-1 /REG 40.1.3
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 16 April 2019 Resolved
09203- ALLEYWAYS, STAIRWAYS, AND EXITS GIVING ACCESS TO THE MUSTER AND EMBARKATION STATIONS SHALL BE LIGHTED. PSCO OBSERVED EMBARKATION LIGHTS NON-OPERATIONAL. 74 SOLAS (1997) CH III /REG 18.5
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 16 April 2019 Resolved
11104- ALLEYWAYS, STAIRWAYS, AND EXITS GIVING ACCESS TO THE MUSTER AND EMBARKATION STATIONS SHALL BE LIGHTED. PSCO OBSERVED EMBARKATION LIGHTS NON-OPERATIONAL. 74 SOLAS (1997) CH III /REG 18.5
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
12 - Dangerous Goods › N/A - No Subsystem › Personal protection
Issued 16 April 2019 Resolved
12108- THE INSTRUMENT SHOULD BE CAPABLE OF REMOTE SAMPLING AND DETECTION FOR ALL GASES THAT IT IS DESIGNED FOR, WITHOUT INTERFERENCE FROM THE ATMOSPHERE OR OTHER CHARACTERISTICS OF THE INTERVENING SPACE. PSCO OBSERVED ONLY ONE OXYGEN METER CONTENT WHICH WAS NOT CALIBRATED. 74 SOLAS (2014) CH XI-1 /REG 7
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 April 2019 Resolved
07106- SUITABLE INSTRUCTIONS AND COMPONENT SPARES FOR TESTING AND MAINTENANCE SHALL BE PROVIDED. PSCO OBSERVED NO TESTING EQUIPMENT WAS AVAILABLE TO TEST HEAT DETECTORS. 74 SOLAS (2014) CH II-2 /REG 13.1.12
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 April 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 16 April 2019 Resolved
10199- ALL SHIPS SHALL HAVE A RECEIVER FOR A GLOBAL NAVIGATION SATELLITE SYSTEM SUITABLE FOR USE AT ALL TIMES TO ESTABLISH AND UPDATE THE SHIP’S POSITION BY AUTOMATIC MEANS. PSCO OBSERVED GPS SCREEN BY PLOTTING TABLE WAS TARNISHED AND UNREADABLE. 74 SOLAS (2014) CH V /REG 19.2.6
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 16 April 2019 Resolved
10199- EVERY SHIP SHALL BE PROVIDED WITH A RECEIVER CAPABLE OF RECEIVING INTERNATIONAL NAVTEX SERVICE BROADCASTS. PSCO OBSERVED GMDSS WAS UNABLE TO TRANSMIT NOR RECEIVE NAVTEX. 74 SOLAS (2014) CH IV /REG 7.1.4
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
01 - Certificates & Documentation › 013 - Documents › Records of seafarers' daily hours of work or rest
Issued 16 April 2019 Resolved
01308- ADMINISTRATION SHALL REQUIRE THAT RECORDS OF DAILY HOURS OF REST OF SEAFARERS BE MAINTAINED IN A STANDARDIZED FORMAT IN THE WORKING LANGUAGE OF THE SHIP. PSCO WAS UNABLE TO OBTAIN REST PERIOD LOG FROM THE [name withheld] /REG 7
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 16 April 2019 Resolved
15113- THE COMPANY SHOULD ESTABLISH PROCEDURES BY WHICH THE SHIP’S PERSONNEL RECEIVE RELEVANT INFORMATION ON THE SAFETY MANAGEMENT SYSTEM IN A WORKING LANGUAGE OR LANGUAGES UNDERSTOOD BY THEM. PSCO OBSERVED THAT THE SAFETY MANAGEMENT SYSTEM WAS NOT IN THE WORKING LANGUAGE OF THE CREW. 74 SOLAS (2014) CH IX /REG 3.1
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 16 April 2019 Resolved
04109- THE DATE WHEN MUSTERS ARE HELD, DETAILS OF ABANDON SHIP DRILLS AND FIRE DRILLS, DRILLS, OF OTHER LIFE-SAVING APPLIANCES AND ONBOARD TRAINING SHALL BE RECORDED IN SUCH A LOG-BOOK AS MAY BE DESCRIBED BY THE ADMINISTRATION. PSCO OBSERVED THAT THE LOG BOOKS ENTRIES FOR ALL DRILLS REQUIRED WERE NOT ACCURATE. 74 SOLAS (1997) CH III /REG 18.5
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 16 April 2019 Resolved
14108- ANY SHIPS OF 400 GROSS TONS AND ABOVE SHALL BE FITTED WITH OIL FILTERING EQUIPMENT. THE SYSTEM SHALL BE PROVIDED WITH ALARM ARRANGEMENTS AND ARRANGEMENTS TO ENSURE THAT ANY DISCHARGE OF OILY MIXTURES IS AUTOMATICALLY STOPPED WHEN THE OIL CONTENT OF THE EFFLUENT EXCEEDS 15 PPM. PSCO OBSERVED THE OILY WATER SEPARATOR DOES NOT SOUND AN ALARM OR SHUT OFF WHEN THE EFFLUENT EXCEEDS 15 PPM. MARPOL ANNEX I / 14.7
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 16 April 2019 Resolved
14604- FOR EACH SHIP OF 400 GROSS TONS AND ABOVE, DETAILS OF FUEL OIL FOR COMBUSTION PURPOSES DELIVERED TO AND USED ON BOARD SHALL BE RECORDED BY MEANS OF A BUNKER DELIVERY NOTE. PSCO OBSERVED THE VESSEL HAD NO BUNKER DELIVERY NOTES ON BOARD. MARPOL ANNEX VI / 18.5
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 16 April 2019 Resolved
14604- WHILE SHIPS ARE OPERATING WITHIN AN EMISSION CONTROL AREA, THE SULFUR CONTENT OF FUEL OIL USED ON BOARD SHIPS SHALL NOT EXCEED .1% M/M ON AND AFTER 1 JANUARY 2015. PSCO OBSERVED THE CREW DID NOT KNOW AND WAS UNABLE TO DETERMINE THE SULFUR CONTENT OF THE FUEL OIL USED ON BOARD. MARPOL ANNEX VI 14.4.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 July 2019
Resolution: Vessel sent fuel sample to a lab for testing and sulfur content; fuel meets regulation requirements.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 16 April 2019 Resolved
99103- VESSELS OPERATING WITHIN 03 NAUTICAL MILES OF THE US MUST CONDUCT ROUTINE VISUAL INSPECTIONS ONCE PER WEEK OR VOYAGE AND DOCUMENT IN OFFICIAL LOGBOOK OR OTHER DOCUMENTATION. INSPECTIONS ARE NOT BEING RECORDED AS REQUIRED UNDER SECTION 4.1.1.1 IN 2013 VGP. 33 USC 1251
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 April 2019 Resolved
01305- A VESSEL EQUIPPED WITH BALLAST WATER TANKS THAT OPERATES IN THE WATERS OF THE UNITED STATES MUST MAINTAIN A BALLAST WATER MANAGEMENT PLAN THAT HAS BEEN DEVELOPED SPECIFICALLY FOR THE VESSEL AND THAT WILL ALLOW THOSE RESPONSIBLE FOR THE PLANS IMPLEMENTATION TO UNDERSTAND AND FOLLOW THE VESSEL'S BALLAST WATER MANAGEMENT STRATEGY AND COMPLY WITH THE REQUIREMENTS OF THIS SUBPART. PSCO OBSERVED VESSEL’S BALLAST WATER MANAGEMENT PLAN DOES NOT INCLUDE ALL OF THE NECESSARY PROVISIONS LISTED IN 33CFR 151 SUBPART D. VESSEL MAY NOT DISCHARGE BALLAST IN U.S. WATERS. 33 CFR 151.2050 (g)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 April 2019 Resolved
01305- TO DISCHARGE BALLAST WATER INTO THE WATERS OF THE UNITED STATES, THE MASTER, OWNER, OPERATOR, AGENT OR PERSON IN CHARGE OF A VESSEL SUBJECT TO 151.2025 OF THIS SUBPART MUST EITHER ENSURE THAT THE BALLAST WATER MEETS THE BALLAST WATER DISCHARGE STANDARD IN 151.2030(A), USE AN AMS AS DESCRIBED IN 151.2025(A)(3), OR BALLAST WITH WATER FROM A U.S. PUBLIC WATER SYSTEM, ACCORDING TO THE SCHEDULE IN PARAGRAPH (B) OF THIS SECTION. SUBJECT VESSEL, OF KEEL LAID DATE 24OCT1987 AND BALLAST WATER CAPACITY OF 1486 M3, IS PAST ITS COMPLIANCE DATE PER THE IMPLEMENTATION SCHEDULE IN 33 CFR 151.2035 (B). VESSEL’S CURRENT BALLAST WATER MANAGEMENT METHOD IS EXCHANGE AND DISCHARGE, WHICH IS NOT AUTHORIZED. VESSEL HAS NO BWTS INSTALLED. VESSEL IS NOT AUTHORIZED TO DISCHARGE UNTREATED BALLAST INTO U.S. WATERS. THIS DEFICIENCY WILL NOT BE CLEARED UNTIL CG EXAMINERS RECEIVE DOCUMENTATION THAT THE VESSEL HAS INSTALLED A BWTS, HAS DECIDED TO USE ON PUBLIC WATER FROM THE U.S. PUBLIC WATER SYSTEM, OR HAS UPDATED ITS BALLAST WATER MANAGEMENT PLAN TO STATE THAT THE VESSEL’S BALLAST WATER MANAGEMENT METHOD IN U.S. WATERS IS NOT TO DISCHARGE. 33 CFR 151.2035
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 16 April 2019 Resolved
01320- EVERY SHIP 100 GROSS TONS AND ABOVE SHALL CARRY A GARBAGE MANAGMENT PLAN WHICH THE CREW SHALL FOLLOW. PSCO OBSERVED THAT THE APPROVED GARBAGE MANAGEMENT PLAN WAS MISSING PAGES AND THAT THE CREW WAS NOT FOLLOWING GARBAGE MANAGEMENT PLAN. MARPOL ANNEX V/10.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 23 October 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 October 2018 Resolved
1020 - ANY REQUIRED FIXED FIRE DETECTION AND FIRE ALARM SYSTEM WITH MANUALLY OPERATED CALL POINTS SHALL BE CAPABLE OF IMMEDIATE OPERATION AT ALL TIMES. PSCO OBSERVED MAIN FIRE CONTROL PANEL ON THE BRIDGE WAS NOT RECEIVING ELECTRICAL POWER AND RENDERED COMPLETELY INOPERABLE. SECONDARY FIRE CONTROL PANEL LOCATED IN THE ENGINE CONTROL ROOM WAS ALSO DISCONNECTED FROM ANY ELECTRICAL POWER SOURCE AND RENDERED COMPLETELY INOPERABLE. THE VESSEL WAS NOT ABLE TO RECEIVE ANY FIRE ALARMS FOR THE FIXED FIRE DETECTION SYSTEM INSTALLED. - 74 SOLAS (1997) II-2/ 13.1.1
Condition: Invalid
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 October 2018 Resolved
1020 - THE ACTIVATION OF ANY DETECTOR OR MANUALLY OPERATED CALL POINT SHALL INITIATE A VISUAL AND AUDIBLE FIRE SIGNAL AT THE CONTROL PANEL AND INDICATING UNITS. PSCO OBSERVED FIXED FIRE DETECTION SMOKE AND HEAT DETECTORS WERE INOPERABLE AND UNAPPROVED HOME SMOKE ALARMS INSTALLED THROUGHOUT THE VESSEL. THE VESSEL'S FIRE DETECTION SYSTEM THROUGHOUT THE ENTIRE SHIP WAS NOT CONNECTED TO A FIRE CONTROL PANEL, DISABLING THE CREW FROM BEING ALERTED OF POTENTIAL FIRE FROM ANYWHERE ON THE VESSEL. - 74 SOLAS (1997) II-2/13.1.4
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 23 October 2018 Resolved
1060 - AN ALARM SYSTEM SHALL BE PROVIDED INDICATING ANY FAULT REQUIRING ATTENTION AND SHALL BE CAPABLE OF SOUNDING AN AUDIBLE ALARM IN MAIN MACHINERY CONTROL ROOM. PSCO OBSERVED THE MAIN CONTROL PANEL TO INCLUDE ALL ALARMS AND GAUGES IN THE ENGINE ROOM WAS NOT OPERATIONAL - THE ENGINE CONTROL ROOM HAS NO ALARMS, NO GAUGES AND NO ELECTRICAL POWER TO CONTROL PANEL. - 74 SOLAS (2004) II-1/51.1.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 October 2018 Resolved
1286 - THE ARRANGEMENT OF THE BILGE AND BALLAST PUMPING SYSTEM SHALL BE SUCH AS TO PREVENT THE POSSIBILITY OF WATER PASSING FROM THE SEA AND FROM WATER BALLAST SPACES INTO THE CARGO AND MACHINERY SPACES. PSCO OBSERVED BALLAST WATER AND SEAWATER SUCTION VALVE STEMS ACTIVELY LEAKING SEAWATER INTO THE ENGINE ROOM. - 74 SOLAS (2004) II-1/21.1.4
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 October 2018 Resolved
1430 - THE CAPACITY OF THE MAIN SOURCE OF ELECTRICAL POWER SHALL BE SUCH THAT IN THE EVENT OF ANY ONE GENERATING SET BEING STOPPED IT WILL STILL BE POSSIBLE TO SUPPLY THOSE SERVICES NECESSARY TO PROVIDE NORMAL OPERATIONAL CONDITIONS OF PROPULSION AND SAFETY. MINIMUM COMFORTABLE CONDITIONS OF HABITABILITY SHALL ALSO BE ENSURED WHICH INCLUDE AT LEAST ADEQUATE SERVICES FOR COOKING, HEATING, DOMESTIC REFRIGERATION, MECHANICAL VENTILATION, SANITARY AND FRESH WATER. PSCO OBSERVED VESSEL UTILIZING EMERGENCY GENERATOR IN PLACE OF MAIN GENERATORS. VESSEL ARRANGEMENT PLANS AND VARIOUS MANUALS ON BOARD SHOWED THAT THE VESSEL WAS BUILT WITH 3 GENERATORS. ONLY 2 GENERATORS ARE CURRENTLY ONBOARD AND ARE NOT ABLE TO SUSTAIN A LOAD FOR NORMAL OPERATIONAL CONDITIONS TO INCLUDE NAVIGATION, MANEUVERING AND PROVIDE HABITABLE LIVING CONDITIONS. - 74 SOLAS (2004) II-1/41.1.2
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 October 2018 Resolved
1499 - THE MACHINERY SHALL BE OF DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. PSCO OBSERVED JACKET WATER COOLING PUMPS AS WELL AS SALT WATER-COOLING PUMPS SEVERELY DETERIORATED AND ACTIVELY LEAKING WHILE PUMPS WERE IN THE OFF POSITION. - 74 SOLAS (2004) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 October 2018 Resolved
1499 - IN A SHIP IN WHICH OIL FUEL IS USED, THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ONBOARD. PSCO OBSERVED OIL LEAKING FROM SCAVENGE AIR BOX ON MAIN DIESEL ENGINE INTO A BUCKET CREATING A SOURCE OF IGNITION. PSCO OBSERVED EVIDENCE OF 2-3 GALLONS OF OIL IN 2 SEPARATE BUCKETS ON EACH SIDE OF THE MAIN ENGINE. - 74 SOLAS (1997) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 October 2018 Resolved
1499 - IN A SHIP IN WHICH OIL FUEL IS USED, THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ONBOARD. PSCO OBSERVED APPROXIMATELY 6 INCHES OF OILY WATER IN AFT ENGINE ROOM BILGE. - 74 SOLAS (1997) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 October 2018 Resolved
0699 - THE ELECTRICAL POWER AVAILABLE SHALL BE SUFFICIENT TO SUPPLY ALL THOSE SERVICES THAT ARE ESSENTIAL FOR SAFETY IN AN EMERGENCY. PSCO OBSERVED INOPERABLE EMERGENCY LIGHTING THROUGHOUT THE ENTIRE VESSEL. - 74 SOLAS (2004) II-1/43.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 October 2018 Resolved
1599 - THE LIGHTS PRESCRIBED IN THESE RULES SHALL HAVE AN INTENSITY AS PRESCRIBED IN SECTION 8 OF ANNEX I OF THESE REGULATIONS. PSCO OBSERVED SEVERAL REQUIRED NAVIGATION LIGHTS NOT PRODUCING ANY LIGHT AS REQUIRED IN COLREGS. - COLREGS 79 Rule 22
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 October 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 23 October 2018 Resolved
1540 - SHIPS OF 500 GROSS TONNAGE AND UPWARDS CONSTRUCTED ON OR AFTER 1 SEPTEMBER 1984 SHALL BE FITTED WITH A GYRO-COMPASS COMPLYING WITH THE FOLLOWING REQUIREMENTS: (I) THE MASTER GYRO-COMPASS OR A GYRO REPEATER SHALL BE CLEARLY READABLE BY THE HELMSMAN AT THE MAIN STEERING POSITION; (II) ON SHIPS OF 1,600 GROSS TONNAGE AND UPWARDS A GYRO REPEATER OR GYRO REPEATERS SHALL BE PROVIDED AND SHALL BE SUITABLY PLACED FOR TAKING BEARINGS AS NEARLY AS PRACTICABLE OVER AN ARC OF THE HORIZON OF 360. PSCO OBSERVED INACCURATE GYRO REPEATER AT THE MAIN STEERING STAND, PROVIDING 30 DEGREES DIFFERENCE FROM THE GYROCOMPASS. ADDITIONALLY THE GYROCOMPASS REPEATERS ON EACH BRIDGE WING AND STEERING GEAR ROOM WERE NOT ACCURATE. - 74 SOLAS (1997) V/12(D)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 October 2018 Resolved
1499 - THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. PSCO OBSERVED OIL SOAKED AIR FILTER ON #2 SERVICE GENERATOR. CHIEF ENGINEER STATED THAT NO SPARES WERE AVAILABLE. - 74 SOLAS (2004) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 October 2018 Resolved
0899 - EFFICIENT GUARDRAILS SHALL BE FITTED TO ALL EXPOSED PARTS OF THE FREEBOARD. PSCO OBSERVED MULTIPLE MISSING OR DETERIORATED GUARD RAILS, CREATING A MAN OVERBOARD RISK TO CREW ON DECK. - ICLL ANNEX I REG. 25.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 October 2018 Resolved
1499 - THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. PSCO OBSERVED BOTH, THE #1 AND #2 STEERING PUMPS, LEAKING HYDRAULIC OIL AND PRESSURE GAUGES WERE NOT OPERATIONAL. - 74 SOLAS (2004) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2018 Resolved
0999 - ALL ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT ALL ELECTRICAL AUXILIARY SERVICES NECESSARY FOR MAINTAINING THE SHIP IN NORMAL OPERATIONAL AND HABITABLE CONDITIONS WILL BE ENSURED WITHOUT RECOURSE TO THE EMERGENCY SOURCE OF ELECTRICAL POWER. PSCO OBSERVED SEVERAL DAISY CHAIN EXTENSION CORDS SUPPLYING POWER TO AT LEAST 6 STATEROOMS FROM THE EMERGENCY POWER ON THE BRIDGE. HOLES WERE DRILLED THROUGH THE EXTERIOR SUPERSTRUCTURE TO FACILITATE THE EXTENSION CORDS PASSAGE TO THE BRIDGE. - 74 SOLAS (2004) II-1/40.1.1
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2018 Resolved
0740 - FIRE-EXTINGUISHING APPLIANCES SHALL BE KEPT IN GOOD ORDER AND BE AVAILABLE FOR IMMEDIATE USE AT ALL TIMES. PSCO OBSERVED THE GENERAL FIRE PUMP WOULD OVERHEAT AFTER SEVERAL MINUTES OF CONTINUOUS OPERATION, RENDERING IT INOPERABLE FOR INTENDED SERVICE. - 74 SOLAS (1997) II-2/21
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2018 Resolved
0740 - FIRE-EXTINGUISHING APPLIANCES SHALL BE KEPT IN GOOD ORDER AND BE AVAILABLE FOR IMMEDIATE USE AT ALL TIMES. PSCO OBSERVED THE EMERGENCY FIRE PUMP LEAK APPROXIMATELY 5 GALLONS OF SEA WATER WHILE RUNNING FOR LESS THAN 5 MINUTES. - 74 SOLAS (1997) II-2/21
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 23 October 2018 Resolved
0925 - FIRE DRILLS SHOULD BE PLANNED IN SUCH A WAY THAT DUE CONSIDERATION IS GIVEN TO REGULAR PRACTICE IN THE VARIOUS EMERGENCIES THAT MAY OCCUR DEPENDING ON THE TYPE OF SHIP AND ITS CARGO. PSCO OBSERVED TABLE TOP FIRE DRILLS BEING RECORDED IN THE VESSEL'S EMERGENCY DRILLS LOG. DURING FIRE DRILLS, PSCO OBSERVED THAT CREW WAS INADEQUATELY TRAINED IN THE USE OF ONBOARD FIREFIGHTING EQUIPMENT. - 74 SOLAS (1997) III/18.3.11
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 23 October 2018 Resolved
0925 - CREW MEMBERS WITH ENCLOSED SPACE ENTRY OR RESCUE RESPONSIBILITIES SHALL PARTICIPATE IN AN ENCLOSED SPACE ENTRY AND RESCUE DRILL TO BE HELD ON BOARD THE SHIP AT LEAST ONCE EVERY TWO MONTHS. PSCO OBSERVED NO ENCLOSED SPACE ENTRY DRILLS BEING RECORDED IN A LOGBOOK. ADDITIONALLY THE VESSEL COULD NOT PROVIDE THE EQUIPMENT TO SAFELY ENTER AN ENCLOSED SPACE. - 74 SOLAS (2014) III / 19.3.3
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 23 October 2018 Resolved
0696 - THE COMPANY SHOULD ESTABLISH AND MAINTAIN PROCEDURES TO CONTROL ALL DOCUMENTS AND DATA WHICH ARE RELEVANT TO THE SAFETY MANAGEMENT SYSTEM. PSCO OBSERVED THAT THE [name withheld] LIFESAVING MAINTENANCE LOG PAGES WHICH INCLUDED HIS SIGNATURE FOR FUTURE LOG ENTRIES. - 74 SOLAS (2014) IX / 3.1 ISM Code Part A / 11.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 23 October 2018 Resolved
0915 - THE COMPANY SHOULD ESTABLISH PROCEDURES, PLANS, AND INSTRUCTIONS INCLUDING CHECKLISTS AS APPROPRIATE FOR KEY SHIPBOARD OPERATION. THE KEY SHIPBOARD OPERATIONS CONCERNING THE SAFETY OF THE PERSONNEL, SHIP AND PROTECTION OF THE ENVIRONMENT. PSCO OBSERVED EMERGENCY PROCEDURES POSTED IN CO2 ROOM WRITTEN IN SPANISH WHEN OFFICIAL LANGUAGE OF CREW IS ENGLISH. - 74 SOLAS (2014) IX / 3.1 ISM Code Part A / 7
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 23 October 2018 Resolved
1730 - ANY SHIPS OF 400 GROSS TONS AND ABOVE SHALL BE FITTED WITH OIL FILTERING EQUIPMENT. PSCO OBSERVED INOPERABLE OILY WATER SEPARATOR. OILY WATER SEPARATOR COULD NOT PROPERLY FUNCTION DUE TO REPEATED "CLEAN MEMBRANE" ALARM. [name withheld] HAS NOT RECEIVED REQUIRED MATERIALS TO MAINTAIN OWS. - MARPOL ANNEX I / 15.6
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 23 October 2018 Resolved
1260 - OPENINGS IN FREEBOARD DECKS OTHER THAN HATCHWAYS, MACHINERY SPACE OPENINGS, MANHOLES AND FLUSH SCUTTLES SHALL BE PROTECTED BY AN ENCLOSED SUPERSTRUCTURE, OR BY A DECKHOUSE OR COMPANIONWAY OF EQUIVALENT STRENGTH AND WEATHER TIGHTNESS. PSCO OBSERVED AT LEAST 10 WINDOWS MISSING THROUGHOUT SUPERSTRUCTURE FOR THE INSTALLATION OF PORTABLE AIR CONDITIONING UNITS, COMPROMISING THE WEATHER TIGHT INTEGRITY. - ICLL ANNEX I REG. 18.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 23 October 2018 Resolved
1510 - ALL SHIPS OF 150 GROSS TONNAGE AND UPWARDS SHALL BE FITTED WITH A SPARE MAGNETIC COMPASS, INTERCHANGEABLE WITH THE MAGNETIC COMPASS. PSCO OBSERVED VESSEL COULD NOT PRODUCE A SPARE MAGNETIC COMPASS AS REQUIRED BY THE VESSEL'S SOLAS CARGO SHIP SAFETY EQUIPMENT CERTIFICATE. - 74 SOLAS (2014) V / 19.2.2.2.1
Condition: Invalid
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2018 Resolved
0830 - ALL ELECTRICAL APPARATUS SHALL BE SO CONSTRUCTED AND SO INSTALLED AS NOT TO CAUSE INJURY WHEN HANDLED OR TOUCHED IN THE NORMAL MANNER. PSCO OBSERVED LOOSE AND EXPOSED WIRING THROUGHOUT THE SHIP TO INCLUDE THE ENGINE ROOM, ON DECK, BRIDGE AND IN STATEROOMS. - 74 SOLAS (2004) II-1 / 45.1.3
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 21 March 2016 Resolved
0740-Pumps-Fire Fighting systems and appliances shall be kept in good working order. Main fire pump #1 has excessive leakage. 74 solas ('14 Cons) II-2/14.2.1.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2016
Resolution: Pump has been fixed, witnessed operational test with no leakage
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 21 March 2016 Resolved
0725-Fixed fire extinguishing installation-Maintenance, testing and inspections shall be carried out base on the guidlines developed by organization, vessel's fixed CO2 bottles, portable fire extinguishers, self-contained breathing apparatus and ergency escape breathing apparatus have not been inspected annually. 74 Solas ('14 Cons) II-2/Reg142.2.1, MSC.1/Circ 1432.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2016
Resolution: All firefighting equipment has been inspected by company
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 March 2016 Resolved
1730-Oily Water separator equipment-Every ship of 400 gt and above shall be fitted with oil filtering equipment. The chief engineer cannot demonstrate the proper operation of the oil water separator. MARPOL annex I/Reg.14.1
Due 21 March 2016
Resolved 21 March 2016
Resolution: Witnessed operation of OWS by Chief Engineer.
Documentation › Logs/Records › Oil Record Book
Issued 21 March 2016 Resolved
1710-Oil Record Book-Each operation (collection of oil residues)shall be fully recorded without delay in the oil record book. The weekly sounds have not been recorded as required and the quantites of the tanks have been recorded incorrectly. MARPOL annex I/Reg.17.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2016
Resolution: ORB updated, Chief engineer given training