Records from 1988 to 2021. Most recent: inspection, 24 September 2021.
Inspection history · 123
24 September 2021
Loadline Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7318171
23 October 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6567054
3 October 2018
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6553714
5 August 2018
Deficiency Check · In-Service Inspection · Ballast Water Examination · ISPS II Exam · PI Safety Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6558333
21 March 2016
ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5837172
15 December 2015
ISPS II Exam · Ballast Water Examination · PII Safety Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5782123
30 September 2015
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5732488
13 August 2015
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5212645
13 August 2015
NPV Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5214928
23 July 2015
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5193183
15 August 2014
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4955645
13 June 2014
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4887787
15 May 2014
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4859449
19 March 2014
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4819121
12 March 2014
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4814970
5 July 2011
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4069897
4 March 2009
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3427338
22 February 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3422939
13 February 2009
ISPS III Exam · PI Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3416798
3 October 2008
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3338091
2 October 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3338064
18 July 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3271694
16 July 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3269807
23 June 2008
MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3245758
22 June 2008
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3244196
22 June 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3246698
16 April 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3185136
15 April 2008
PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3183866
15 April 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3186823
17 January 2008
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 3132505
18 November 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3101045
24 September 2007
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3065479
22 September 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3063441
4 September 2007
MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3047967
2 July 2007
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2980370
8 March 2007
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2883919
6 March 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2882447
6 February 2007
NPV Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2867779
24 October 2006
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2807001
21 October 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2804967
31 August 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2765047
23 April 2006
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2631421
19 April 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2628418
15 April 2006
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2625384
13 April 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2624332
6 April 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2618775
2 April 2006
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2617110
31 March 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2613447
31 March 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2613485
17 February 2006
MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2587094
29 March 2005
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2321955
15 February 2005
PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2292760
4 February 2005
ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2286590
7 December 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2254647
17 November 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2243017
14 November 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2240499
18 October 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2223115
6 October 2004
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2214790
25 August 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2176922
21 August 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2173108
19 August 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2170311
15 August 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2166257
13 August 2004
PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2164887
29 June 2004
ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2114646
16 June 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2099943
13 June 2004
Type not recorded
No type recorded · GROUP MIAMI · USCG Southeast District (CGD-SE) · Activity 2096616
13 May 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2066781
22 April 2004
Administrative Inspection · Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2050241
22 April 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2050245
22 April 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2050765
22 April 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2053610
7 April 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2037556
23 February 2004
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2011592
29 January 2004
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1996149
26 September 2003
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1913867
28 August 2003
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1889492
17 April 2003
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1775263
2 April 2003
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1767394
6 February 2003
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1740650
15 January 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1731095
4 December 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1714103
24 November 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1710115
13 November 2002
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 1704697
7 November 2002
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1702111
6 November 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1701596
3 October 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1683677
9 September 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1673279
28 August 2002
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1667568
28 August 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1667735
19 August 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1663110
30 January 2002
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1482566
13 August 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 190084
13 August 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 769490
3 January 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 16805
22 August 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 281255
28 January 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 273959
15 December 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 78826
24 June 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 429938
14 May 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 428813
30 November 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 195090
30 November 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 760622
2 April 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 414672
14 February 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 401319
13 February 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 400574
26 July 1996
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 393503
29 January 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 387387
11 April 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 377181
12 March 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 376710
10 March 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 365129
19 November 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 362516
17 November 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 94572
17 November 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 176297
22 September 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 43124
4 May 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 357988
20 February 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 356456
31 July 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 352412
26 March 1992
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 349665
30 January 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 348660
14 August 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 498315
13 September 1990
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 339424
15 March 1990
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 336016
3 August 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 331844
20 July 1988
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 324651
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 April 2019
Resolved
13104- AN EFFICIENT BILGE PUMPING SYSTEM SHALL BE PROVIDED, CAPABLE OF PUMPING FROM AND DRAINING ANY WATERTIGHT COMPARTMENT OTHER THAN A SPACE PERMANENTLY APPROPRIATED FOR THE CARRIAGE OF FRESH WATER, WATER BALLAST, OIL FUEL OR LIQUID CARGO AND FOR WHICH OTHER EFFICIENT MEANS OF PUMPING ARE PROVIDED, UNDER ALL PRACTICAL CONDITIONS. EFFICIENT MEANS SHALL BE PROVIDED FOR DRAINING WATER FROM INSULATED HOLDS. PSCO OBSERVED AN INOPERABLE BILGE PUMP SYSTEM DUE TO REMOVAL OF THE BILGE PUMP AND ASSOCIATED PIPING. 74 SOLAS (2004)CH II-1/REG 21.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 April 2019
Resolved
02105- STEERING GEAR CONTROL SHALL BE PROVIDED WHERE THE MAIN STEERING GEAR IS ARRANGED WITH TWO INDEPENDENT CONTROL SYSTEMS, BOTH OPERABLE FROM THE BRIDGE. PSCO OBSERVED THAT NEITHER THE STEERING WHEEL NOR THE STEERING LEVER WERE WORKING IN FOLLOW-UP OR NON-FOLLOW-UP MODE AT THE CONNING POSITION. 74 SOLAS (2004)CH II-1 /REG 29.7.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 16 April 2019
Resolved
08103- THERE SHALL BE NO LESS THAN TWO SOURCES OF POWER SUPPLY FOR THE ELECTRICAL EQUIPMENT USED IN THE OPERATION OF THE FIRE DETECTION AND THE FIRE ALARM SYSTEM, ONE OF WHICH SHALL BE AN EMERGENCY SOURCE. PSCO OBSERVED THE FIRE ALARM PANEL, LOCATED ON THE NAVIGATION BRIDGE, WAS POWERED THROUGH A POWER OUTLET WHICH WAS NOT CONNECTED TO THE EMERGENCY POWER SUPPLY AND WAS NOT RECEIVING ALL ALARMS TESTED. 74 SOLAS (1997)CH II-2 /REG 13.1.1.3
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 April 2019
Resolved
99101- THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM TO THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO OBSERVED SEA CHEST BOLTS WERE CORRODED OR MISSING. 74 SOLAS (2004)CH I-1 /REG 11.1
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 16 April 2019
Resolved
07114- MEANS SHALL BE PROVIDED WHEREBY NORMAL OPERATION OF PROPULSION MACHINERY CAN BE SUSTAINED OR RESTORED EVEN THOUGH ONE OF THE ESSENTIAL AUXILIARIES BECOMES INOPERATIVE. SPECIAL CONSIDERATION SHALL BE GIVEN TO THE MALFUNCTIONING OF THE FUEL OIL SUPPLY SYSTEMS FOR BOILERS OR ENGINES. PSCO OBSERVED FUEL AND LUBE OIL SHUTOFF VALVES DISCONNECTED AND INOPERABLE.
74 SOLAS (2004) CH II-1/REG 26.3.4
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 April 2019
Resolved
07199- INTERNAL COMBUSTION ENGINES OF 2,250 KW AND ABOVE OR HAVING CYLINDERS OF MORE THAN 300 MM BORE SHALL BE PROVIDED WITH CRANKCASE OIL MIST DETECTORS OR ENGINE BEARING TEMPERATURE MONITORS OR EQUIVALENT DEVICES. PSCO OBSERVED OIL MIST DETECTION INOPERABLE. 74 SOLAS (2004)CH II-1/REG 47.2
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 April 2019
Resolved
07105- STAIRWAYS AND LIFT TRUNKS WHICH PENETRATE MORE THAN A SINGLE DECK SHALL BE SURROUNDED BY AT LEAST ``A-0'' CLASS DIVISIONS AND BE PROTECTED BY SELF-CLOSING DOORS AT ALL LEVELS. PSCO OBSERVED SHORE TIE CABLE COMING FORM THE PIER THROUGH THE HOUSE AND INTO THE ENGINE ROOM AND CONTROL ROOM, THUS PREVENTING DOOR CLOSURE AND VOIDING ALL FIRE BOUNDARIES. 74 SOLAS (1997) CH II-2 /REG 46.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 April 2019
Resolved
07105- DOORS REQUIRED TO BE SELF-CLOSING SHALL NOT BE FITTED WITH HOLD-BACK HOOKS. PSCO OBSERVED SEVERAL SELF-CLOSING DOORS LATCHED OPEN OR MISSING IN THE ENGINE ROOM AND THROUGHOUT THE MAIN HOUSE TO ALLOW SHORE TIE CABLE TO BE CONNECTED TO THE MAIN SWITCHBOARD. 74 SOLAS (1997) CH II-2 /REG 30.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 April 2019
Resolved
07105- THE CONSTRUCTION OF ALL DOORS AND DOOR FRAMES IN “A” CLASS DIVISION, WITH THE MEANS OF SECURING THEM WHEN CLOSED SHALL PROVIDE RESISTANCE TO FIRE AS WELL AS TO THE PASSAGE OF SMOKE AND FLAME. PSCO OBSERVED EMERGENCY ESCAPE DOORS THAT WERE RUSTED THROUGH. 74 SOLAS (1997) CH II-2 /REG 30.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 16 April 2019
Resolved
07122- FIRE CONTROL PLANS SHALL BE KEPT UP TO DATE, ANY ALTERNATIONS BEING RECORDED THEREON AS SOON AS POSSIBLE. PSCO OBSERVED THAT THE POSTED FIRE CONTROL PLAN DID NOT ACCURATELY REPRESENT SHIP'S CURRENT FIRE CONTROL ARRANGEMENTS. 74 SOLAS (1997) CH II-2 /REG 21.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 April 2019
Resolved
13108- MEANS SHALL BE PROVIDED WHEREBY NORMAL OPERATION OF PROPULSION MACHINERY CAN BE SUSTAINED OR RESTORED EVEN THOUGH ONE OF THE ESSENTIAL AUXILIARIES BECOMES INOPERATIVE. SPECIAL CONSIDERATION SHALL BE GIVEN TO THE MALFUNCTIONING OF THE FUEL OIL SUPPLY SYSTEMS FOR BOILERS OR ENGINES. PSCO OBSERVED FUEL OIL SHUTOFF VALVES WERE DISCONNECTED AND NO MAINTENANCE WERE PERFORMED TO KEEP THEM OPERATIONAL. 74 SOLAS (2004) CH II-1 /REG 26.3.4
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 April 2019
Resolved
13101- THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. PSCO OBSERVED MAIN ENGINE OIL PUMPS INOPERABLE. 74 SOLAS (2004) CH II-1 /REG 26.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 April 2019
Resolved
09298- CYLINDERS MUST ALWAYS BE SECURED AND, WHEN NOT IN USE, THEY MUST BE STOWED IN A RACK IN AN UPRIGHT POSITION, WITH THE VALVE PROTECTION CAP IN PLACE. PSCO OBSERVED MULTIPLE OXYGEN AND ACETYLENE CYLINDERS STORED ON THE MAIN DECK VIA RATCHET STRAPS. 46 CFR 147.60(b)(1)
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
09 - Working and Living Conditions › 092 - Working Conditions › Entry dangerous spaces
Issued 16 April 2019
Resolved
09221- LOCKERS OR HOUSINGS MUST BE VENTED TO THE OPEN AIR NEAR THE TOP AND BOTTOM FOR POSITIVE CIRCULATION OF VAPORS. PSCO OBSERVED THAT THE WELDER STORE ROOM WAS FILLED WITH CYLINDERS AND THE SPACE DID NOT PROVIDE ADEQUATE VENTILATION FOR GAS CYLINDERS. 46 CFR 147.60(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 April 2019
Resolved
13199- THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. PSCO OBSERVED WELDED PIPE INTENDED TO FEED MAIN ENGINE COOLING SYSTEM FROM FIRE MAIN WITH UNAPPROVED REPAIRS. 74 SOLAS (2004) CH II-1 /REG 26.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 April 2019
Resolved
02108- THE RATING OR APPROPRIATE SETTING OF THE OVERLOAD PROTECTIVE DEVICE FOR EACH CIRCUIT SHALL BE PERMANENTLY INDICATED AT THE LOCATION OF THE PROTECTIVE DEVICE. PSCO OBSERVED FUSES ON SWITCH BOARD DIDN’T MATCH PLACARDS. 74 SOLAS (2004) CH II-1 /REG 45.6.2
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 16 April 2019
Resolved
08104- ANY MAIN AND AUXILIARY STEERING CONTROL SYSTEM OPERABLE FROM THE NAVIGATION BRIDGE SHALL IN THE EVENT OF A FAILURE OF ELECTRICAL POWER SUPPLY TO THE CONTROL SYSTEM, AN AUDIBLE AND VISUAL ALARM SHALL BE GIVEN ON THE NAVIGATION BRIDGE. PSCO OBSERVED THAT THE STEERING ALARM PANEL DID NOT PROVIDE CORRECT VISUAL NOR AUDIBLE ALARM. 74 SOLAS (2004) CH II-1 /REG 29.8.4
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 April 2019
Resolved
11129- EVERY LIFERAFT SHALL BE STOWED SO THE LIFERAFT FLOATS FREE AND, IF INFLATABLE, INFLATES AUTOMATICALLY WHEN THE SHIP SINKS. PSCO OBSERVED LIFERAFT HYDROSTATIC RELEASE WAS IMPROPERLY INSTALLED. 74 SOLAS (1997) CH III /REG 29
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 April 2019
Resolved
02108- THE SAFETY OF CREW AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. PSCO OBSERVED EXPOSED WIRES THROUGH WASTED CABLE RUNS ON DECK. 74 SOLAS (1997) CH II-1 /REG 40.1.3
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 16 April 2019
Resolved
09203- ALLEYWAYS, STAIRWAYS, AND EXITS GIVING ACCESS TO THE MUSTER AND EMBARKATION STATIONS SHALL BE LIGHTED. PSCO OBSERVED EMBARKATION LIGHTS NON-OPERATIONAL. 74 SOLAS (1997) CH III /REG 18.5
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 16 April 2019
Resolved
11104- ALLEYWAYS, STAIRWAYS, AND EXITS GIVING ACCESS TO THE MUSTER AND EMBARKATION STATIONS SHALL BE LIGHTED. PSCO OBSERVED EMBARKATION LIGHTS NON-OPERATIONAL. 74 SOLAS (1997) CH III /REG 18.5
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
12 - Dangerous Goods › N/A - No Subsystem › Personal protection
Issued 16 April 2019
Resolved
12108- THE INSTRUMENT SHOULD BE CAPABLE OF REMOTE SAMPLING AND DETECTION FOR ALL GASES THAT IT IS DESIGNED FOR, WITHOUT INTERFERENCE FROM THE ATMOSPHERE OR OTHER CHARACTERISTICS OF THE INTERVENING SPACE. PSCO OBSERVED ONLY ONE OXYGEN METER CONTENT WHICH WAS NOT CALIBRATED. 74 SOLAS (2014) CH XI-1 /REG 7
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 April 2019
Resolved
07106- SUITABLE INSTRUCTIONS AND COMPONENT SPARES FOR TESTING AND MAINTENANCE SHALL BE PROVIDED. PSCO OBSERVED NO TESTING EQUIPMENT WAS AVAILABLE TO TEST HEAT DETECTORS. 74 SOLAS (2014) CH II-2 /REG 13.1.12
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 April 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 16 April 2019
Resolved
10199- ALL SHIPS SHALL HAVE A RECEIVER FOR A GLOBAL NAVIGATION SATELLITE SYSTEM SUITABLE FOR USE AT ALL TIMES TO ESTABLISH AND UPDATE THE SHIP’S POSITION BY AUTOMATIC MEANS. PSCO OBSERVED GPS SCREEN BY PLOTTING TABLE WAS TARNISHED AND UNREADABLE. 74 SOLAS (2014) CH V /REG 19.2.6
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 16 April 2019
Resolved
10199- EVERY SHIP SHALL BE PROVIDED WITH A RECEIVER CAPABLE OF RECEIVING INTERNATIONAL NAVTEX SERVICE BROADCASTS. PSCO OBSERVED GMDSS WAS UNABLE TO TRANSMIT NOR RECEIVE NAVTEX. 74 SOLAS (2014) CH IV /REG 7.1.4
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
01 - Certificates & Documentation › 013 - Documents › Records of seafarers' daily hours of work or rest
Issued 16 April 2019
Resolved
01308- ADMINISTRATION SHALL REQUIRE THAT RECORDS OF DAILY HOURS OF REST OF SEAFARERS BE MAINTAINED IN A STANDARDIZED FORMAT IN THE WORKING LANGUAGE OF THE SHIP. PSCO WAS UNABLE TO OBTAIN REST PERIOD LOG FROM THE [name withheld] /REG 7
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 16 April 2019
Resolved
15113- THE COMPANY SHOULD ESTABLISH PROCEDURES BY WHICH THE SHIP’S PERSONNEL RECEIVE RELEVANT INFORMATION ON THE SAFETY MANAGEMENT SYSTEM IN A WORKING LANGUAGE OR LANGUAGES UNDERSTOOD BY THEM. PSCO OBSERVED THAT THE SAFETY MANAGEMENT SYSTEM WAS NOT IN THE WORKING LANGUAGE OF THE CREW. 74 SOLAS (2014) CH IX /REG 3.1
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 16 April 2019
Resolved
04109- THE DATE WHEN MUSTERS ARE HELD, DETAILS OF ABANDON SHIP DRILLS AND FIRE DRILLS, DRILLS, OF OTHER LIFE-SAVING APPLIANCES AND ONBOARD TRAINING SHALL BE RECORDED IN SUCH A LOG-BOOK AS MAY BE DESCRIBED BY THE ADMINISTRATION. PSCO OBSERVED THAT THE LOG BOOKS ENTRIES FOR ALL DRILLS REQUIRED WERE NOT ACCURATE. 74 SOLAS (1997) CH III /REG 18.5
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 16 April 2019
Resolved
14108- ANY SHIPS OF 400 GROSS TONS AND ABOVE SHALL BE FITTED WITH OIL FILTERING EQUIPMENT. THE SYSTEM SHALL BE PROVIDED WITH ALARM ARRANGEMENTS AND ARRANGEMENTS TO ENSURE THAT ANY DISCHARGE OF OILY MIXTURES IS AUTOMATICALLY STOPPED WHEN THE OIL CONTENT OF THE EFFLUENT EXCEEDS 15 PPM. PSCO OBSERVED THE OILY WATER SEPARATOR DOES NOT SOUND AN ALARM OR SHUT OFF WHEN THE EFFLUENT EXCEEDS 15 PPM. MARPOL ANNEX I / 14.7
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 16 April 2019
Resolved
14604- FOR EACH SHIP OF 400 GROSS TONS AND ABOVE, DETAILS OF FUEL OIL FOR COMBUSTION PURPOSES DELIVERED TO AND USED ON BOARD SHALL BE RECORDED BY MEANS OF A BUNKER DELIVERY NOTE. PSCO OBSERVED THE VESSEL HAD NO BUNKER DELIVERY NOTES ON BOARD. MARPOL ANNEX VI / 18.5
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 16 April 2019
Resolved
14604- WHILE SHIPS ARE OPERATING WITHIN AN EMISSION CONTROL AREA, THE SULFUR CONTENT OF FUEL OIL USED ON BOARD SHIPS SHALL NOT EXCEED .1% M/M ON AND AFTER 1 JANUARY 2015. PSCO OBSERVED THE CREW DID NOT KNOW AND WAS UNABLE TO DETERMINE THE SULFUR CONTENT OF THE FUEL OIL USED ON BOARD. MARPOL ANNEX VI 14.4.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 July 2019
Resolution: Vessel sent fuel sample to a lab for testing and sulfur content; fuel meets regulation requirements.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 16 April 2019
Resolved
99103- VESSELS OPERATING WITHIN 03 NAUTICAL MILES OF THE US MUST CONDUCT ROUTINE VISUAL INSPECTIONS ONCE PER WEEK OR VOYAGE AND DOCUMENT IN OFFICIAL LOGBOOK OR OTHER DOCUMENTATION. INSPECTIONS ARE NOT BEING RECORDED AS REQUIRED UNDER SECTION 4.1.1.1 IN 2013 VGP. 33 USC 1251
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 April 2019
Resolved
01305- A VESSEL EQUIPPED WITH BALLAST WATER TANKS THAT OPERATES IN THE WATERS OF THE UNITED STATES MUST MAINTAIN A BALLAST WATER MANAGEMENT PLAN THAT HAS BEEN DEVELOPED SPECIFICALLY FOR THE VESSEL AND THAT WILL ALLOW THOSE RESPONSIBLE FOR THE PLANS IMPLEMENTATION TO UNDERSTAND AND FOLLOW THE VESSEL'S BALLAST WATER MANAGEMENT STRATEGY AND COMPLY WITH THE REQUIREMENTS OF THIS SUBPART. PSCO OBSERVED VESSEL’S BALLAST WATER MANAGEMENT PLAN DOES NOT INCLUDE ALL OF THE NECESSARY PROVISIONS LISTED IN 33CFR 151 SUBPART D. VESSEL MAY NOT DISCHARGE BALLAST IN U.S. WATERS. 33 CFR 151.2050 (g)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 April 2019
Resolved
01305- TO DISCHARGE BALLAST WATER INTO THE WATERS OF THE UNITED STATES, THE MASTER, OWNER, OPERATOR, AGENT OR PERSON IN CHARGE OF A VESSEL SUBJECT TO 151.2025 OF THIS SUBPART MUST EITHER ENSURE THAT THE BALLAST WATER MEETS THE BALLAST WATER DISCHARGE STANDARD IN 151.2030(A), USE AN AMS AS DESCRIBED IN 151.2025(A)(3), OR BALLAST WITH WATER FROM A U.S. PUBLIC WATER SYSTEM, ACCORDING TO THE SCHEDULE IN PARAGRAPH (B) OF THIS SECTION. SUBJECT VESSEL, OF KEEL LAID DATE 24OCT1987 AND BALLAST WATER CAPACITY OF 1486 M3, IS PAST ITS COMPLIANCE DATE PER THE IMPLEMENTATION SCHEDULE IN 33 CFR 151.2035 (B). VESSEL’S CURRENT BALLAST WATER MANAGEMENT METHOD IS EXCHANGE AND DISCHARGE, WHICH IS NOT AUTHORIZED. VESSEL HAS NO BWTS INSTALLED. VESSEL IS NOT AUTHORIZED TO DISCHARGE UNTREATED BALLAST INTO U.S. WATERS. THIS DEFICIENCY WILL NOT BE CLEARED UNTIL CG EXAMINERS RECEIVE DOCUMENTATION THAT THE VESSEL HAS INSTALLED A BWTS, HAS DECIDED TO USE ON PUBLIC WATER FROM THE U.S. PUBLIC WATER SYSTEM, OR HAS UPDATED ITS BALLAST WATER MANAGEMENT PLAN TO STATE THAT THE VESSEL’S BALLAST WATER MANAGEMENT METHOD IN U.S. WATERS IS NOT TO DISCHARGE. 33 CFR 151.2035
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 16 April 2019
Resolved
01320- EVERY SHIP 100 GROSS TONS AND ABOVE SHALL CARRY A GARBAGE MANAGMENT PLAN WHICH THE CREW SHALL FOLLOW. PSCO OBSERVED THAT THE APPROVED GARBAGE MANAGEMENT PLAN WAS MISSING PAGES AND THAT THE CREW WAS NOT FOLLOWING GARBAGE MANAGEMENT PLAN. MARPOL ANNEX V/10.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2021
Resolution: Vessel scrapped.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 23 October 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 October 2018
Resolved
1020 - ANY REQUIRED FIXED FIRE DETECTION AND FIRE ALARM SYSTEM WITH MANUALLY OPERATED CALL POINTS SHALL BE CAPABLE OF IMMEDIATE OPERATION AT ALL TIMES. PSCO OBSERVED MAIN FIRE CONTROL PANEL ON THE BRIDGE WAS NOT RECEIVING ELECTRICAL POWER AND RENDERED COMPLETELY INOPERABLE. SECONDARY FIRE CONTROL PANEL LOCATED IN THE ENGINE CONTROL ROOM WAS ALSO DISCONNECTED FROM ANY ELECTRICAL POWER SOURCE AND RENDERED COMPLETELY INOPERABLE. THE VESSEL WAS NOT ABLE TO RECEIVE ANY FIRE ALARMS FOR THE FIXED FIRE DETECTION SYSTEM INSTALLED. - 74 SOLAS (1997) II-2/ 13.1.1
Condition: Invalid
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 October 2018
Resolved
1020 - THE ACTIVATION OF ANY DETECTOR OR MANUALLY OPERATED CALL POINT SHALL INITIATE A VISUAL AND AUDIBLE FIRE SIGNAL AT THE CONTROL PANEL AND INDICATING UNITS. PSCO OBSERVED FIXED FIRE DETECTION SMOKE AND HEAT DETECTORS WERE INOPERABLE AND UNAPPROVED HOME SMOKE ALARMS INSTALLED THROUGHOUT THE VESSEL. THE VESSEL'S FIRE DETECTION SYSTEM THROUGHOUT THE ENTIRE SHIP WAS NOT CONNECTED TO A FIRE CONTROL PANEL, DISABLING THE CREW FROM BEING ALERTED OF POTENTIAL FIRE FROM ANYWHERE ON THE VESSEL. - 74 SOLAS (1997) II-2/13.1.4
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 23 October 2018
Resolved
1060 - AN ALARM SYSTEM SHALL BE PROVIDED INDICATING ANY FAULT REQUIRING ATTENTION AND SHALL BE CAPABLE OF SOUNDING AN AUDIBLE ALARM IN MAIN MACHINERY CONTROL ROOM. PSCO OBSERVED THE MAIN CONTROL PANEL TO INCLUDE ALL ALARMS AND GAUGES IN THE ENGINE ROOM WAS NOT OPERATIONAL - THE ENGINE CONTROL ROOM HAS NO ALARMS, NO GAUGES AND NO ELECTRICAL POWER TO CONTROL PANEL. - 74 SOLAS (2004) II-1/51.1.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 October 2018
Resolved
1286 - THE ARRANGEMENT OF THE BILGE AND BALLAST PUMPING SYSTEM SHALL BE SUCH AS TO PREVENT THE POSSIBILITY OF WATER PASSING FROM THE SEA AND FROM WATER BALLAST SPACES INTO THE CARGO AND MACHINERY SPACES. PSCO OBSERVED BALLAST WATER AND SEAWATER SUCTION VALVE STEMS ACTIVELY LEAKING SEAWATER INTO THE ENGINE ROOM. - 74 SOLAS (2004) II-1/21.1.4
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 October 2018
Resolved
1430 - THE CAPACITY OF THE MAIN SOURCE OF ELECTRICAL POWER SHALL BE SUCH THAT IN THE EVENT OF ANY ONE GENERATING SET BEING STOPPED IT WILL STILL BE POSSIBLE TO SUPPLY THOSE SERVICES NECESSARY TO PROVIDE NORMAL OPERATIONAL CONDITIONS OF PROPULSION AND SAFETY. MINIMUM COMFORTABLE CONDITIONS OF HABITABILITY SHALL ALSO BE ENSURED WHICH INCLUDE AT LEAST ADEQUATE SERVICES FOR COOKING, HEATING, DOMESTIC REFRIGERATION, MECHANICAL VENTILATION, SANITARY AND FRESH WATER. PSCO OBSERVED VESSEL UTILIZING EMERGENCY GENERATOR IN PLACE OF MAIN GENERATORS. VESSEL ARRANGEMENT PLANS AND VARIOUS MANUALS ON BOARD SHOWED THAT THE VESSEL WAS BUILT WITH 3 GENERATORS. ONLY 2 GENERATORS ARE CURRENTLY ONBOARD AND ARE NOT ABLE TO SUSTAIN A LOAD FOR NORMAL OPERATIONAL CONDITIONS TO INCLUDE NAVIGATION, MANEUVERING AND PROVIDE HABITABLE LIVING CONDITIONS. - 74 SOLAS (2004) II-1/41.1.2
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 October 2018
Resolved
1499 - THE MACHINERY SHALL BE OF DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. PSCO OBSERVED JACKET WATER COOLING PUMPS AS WELL AS SALT WATER-COOLING PUMPS SEVERELY DETERIORATED AND ACTIVELY LEAKING WHILE PUMPS WERE IN THE OFF POSITION. - 74 SOLAS (2004) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 October 2018
Resolved
1499 - IN A SHIP IN WHICH OIL FUEL IS USED, THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ONBOARD. PSCO OBSERVED OIL LEAKING FROM SCAVENGE AIR BOX ON MAIN DIESEL ENGINE INTO A BUCKET CREATING A SOURCE OF IGNITION. PSCO OBSERVED EVIDENCE OF 2-3 GALLONS OF OIL IN 2 SEPARATE BUCKETS ON EACH SIDE OF THE MAIN ENGINE. - 74 SOLAS (1997) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 October 2018
Resolved
1499 - IN A SHIP IN WHICH OIL FUEL IS USED, THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ONBOARD. PSCO OBSERVED APPROXIMATELY 6 INCHES OF OILY WATER IN AFT ENGINE ROOM BILGE. - 74 SOLAS (1997) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 October 2018
Resolved
0699 - THE ELECTRICAL POWER AVAILABLE SHALL BE SUFFICIENT TO SUPPLY ALL THOSE SERVICES THAT ARE ESSENTIAL FOR SAFETY IN AN EMERGENCY. PSCO OBSERVED INOPERABLE EMERGENCY LIGHTING THROUGHOUT THE ENTIRE VESSEL. - 74 SOLAS (2004) II-1/43.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 October 2018
Resolved
1599 - THE LIGHTS PRESCRIBED IN THESE RULES SHALL HAVE AN INTENSITY AS PRESCRIBED IN SECTION 8 OF ANNEX I OF THESE REGULATIONS. PSCO OBSERVED SEVERAL REQUIRED NAVIGATION LIGHTS NOT PRODUCING ANY LIGHT AS REQUIRED IN COLREGS. - COLREGS 79 Rule 22
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 October 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 23 October 2018
Resolved
1540 - SHIPS OF 500 GROSS TONNAGE AND UPWARDS CONSTRUCTED ON OR AFTER 1 SEPTEMBER 1984 SHALL BE FITTED WITH A GYRO-COMPASS COMPLYING WITH THE FOLLOWING REQUIREMENTS: (I) THE MASTER GYRO-COMPASS OR A GYRO REPEATER SHALL BE CLEARLY READABLE BY THE HELMSMAN AT THE MAIN STEERING POSITION; (II) ON SHIPS OF 1,600 GROSS TONNAGE AND UPWARDS A GYRO REPEATER OR GYRO REPEATERS SHALL BE PROVIDED AND SHALL BE SUITABLY PLACED FOR TAKING BEARINGS AS NEARLY AS PRACTICABLE OVER AN ARC OF THE HORIZON OF 360. PSCO OBSERVED INACCURATE GYRO REPEATER AT THE MAIN STEERING STAND, PROVIDING 30 DEGREES DIFFERENCE FROM THE GYROCOMPASS. ADDITIONALLY THE GYROCOMPASS REPEATERS ON EACH BRIDGE WING AND STEERING GEAR ROOM WERE NOT ACCURATE. - 74 SOLAS (1997) V/12(D)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 October 2018
Resolved
1499 - THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. PSCO OBSERVED OIL SOAKED AIR FILTER ON #2 SERVICE GENERATOR. CHIEF ENGINEER STATED THAT NO SPARES WERE AVAILABLE. - 74 SOLAS (2004) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 October 2018
Resolved
0899 - EFFICIENT GUARDRAILS SHALL BE FITTED TO ALL EXPOSED PARTS OF THE FREEBOARD. PSCO OBSERVED MULTIPLE MISSING OR DETERIORATED GUARD RAILS, CREATING A MAN OVERBOARD RISK TO CREW ON DECK. - ICLL ANNEX I REG. 25.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 October 2018
Resolved
1499 - THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. PSCO OBSERVED BOTH, THE #1 AND #2 STEERING PUMPS, LEAKING HYDRAULIC OIL AND PRESSURE GAUGES WERE NOT OPERATIONAL. - 74 SOLAS (2004) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2018
Resolved
0999 - ALL ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT ALL ELECTRICAL AUXILIARY SERVICES NECESSARY FOR MAINTAINING THE SHIP IN NORMAL OPERATIONAL AND HABITABLE CONDITIONS WILL BE ENSURED WITHOUT RECOURSE TO THE EMERGENCY SOURCE OF ELECTRICAL POWER. PSCO OBSERVED SEVERAL DAISY CHAIN EXTENSION CORDS SUPPLYING POWER TO AT LEAST 6 STATEROOMS FROM THE EMERGENCY POWER ON THE BRIDGE. HOLES WERE DRILLED THROUGH THE EXTERIOR SUPERSTRUCTURE TO FACILITATE THE EXTENSION CORDS PASSAGE TO THE BRIDGE. - 74 SOLAS (2004) II-1/40.1.1
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2018
Resolved
0740 - FIRE-EXTINGUISHING APPLIANCES SHALL BE KEPT IN GOOD ORDER AND BE AVAILABLE FOR IMMEDIATE USE AT ALL TIMES. PSCO OBSERVED THE GENERAL FIRE PUMP WOULD OVERHEAT AFTER SEVERAL MINUTES OF CONTINUOUS OPERATION, RENDERING IT INOPERABLE FOR INTENDED SERVICE. - 74 SOLAS (1997) II-2/21
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2018
Resolved
0740 - FIRE-EXTINGUISHING APPLIANCES SHALL BE KEPT IN GOOD ORDER AND BE AVAILABLE FOR IMMEDIATE USE AT ALL TIMES. PSCO OBSERVED THE EMERGENCY FIRE PUMP LEAK APPROXIMATELY 5 GALLONS OF SEA WATER WHILE RUNNING FOR LESS THAN 5 MINUTES. - 74 SOLAS (1997) II-2/21
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 23 October 2018
Resolved
0925 - FIRE DRILLS SHOULD BE PLANNED IN SUCH A WAY THAT DUE CONSIDERATION IS GIVEN TO REGULAR PRACTICE IN THE VARIOUS EMERGENCIES THAT MAY OCCUR DEPENDING ON THE TYPE OF SHIP AND ITS CARGO. PSCO OBSERVED TABLE TOP FIRE DRILLS BEING RECORDED IN THE VESSEL'S EMERGENCY DRILLS LOG. DURING FIRE DRILLS, PSCO OBSERVED THAT CREW WAS INADEQUATELY TRAINED IN THE USE OF ONBOARD FIREFIGHTING EQUIPMENT. - 74 SOLAS (1997) III/18.3.11
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 23 October 2018
Resolved
0925 - CREW MEMBERS WITH ENCLOSED SPACE ENTRY OR RESCUE RESPONSIBILITIES SHALL PARTICIPATE IN AN ENCLOSED SPACE ENTRY AND RESCUE DRILL TO BE HELD ON BOARD THE SHIP AT LEAST ONCE EVERY TWO MONTHS. PSCO OBSERVED NO ENCLOSED SPACE ENTRY DRILLS BEING RECORDED IN A LOGBOOK. ADDITIONALLY THE VESSEL COULD NOT PROVIDE THE EQUIPMENT TO SAFELY ENTER AN ENCLOSED SPACE. - 74 SOLAS (2014) III / 19.3.3
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 23 October 2018
Resolved
0696 - THE COMPANY SHOULD ESTABLISH AND MAINTAIN PROCEDURES TO CONTROL ALL DOCUMENTS AND DATA WHICH ARE RELEVANT TO THE SAFETY MANAGEMENT SYSTEM. PSCO OBSERVED THAT THE [name withheld] LIFESAVING MAINTENANCE LOG PAGES WHICH INCLUDED HIS SIGNATURE FOR FUTURE LOG ENTRIES. - 74 SOLAS (2014) IX / 3.1 ISM Code Part A / 11.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 23 October 2018
Resolved
0915 - THE COMPANY SHOULD ESTABLISH PROCEDURES, PLANS, AND INSTRUCTIONS INCLUDING CHECKLISTS AS APPROPRIATE FOR KEY SHIPBOARD OPERATION. THE KEY SHIPBOARD OPERATIONS CONCERNING THE SAFETY OF THE PERSONNEL, SHIP AND PROTECTION OF THE ENVIRONMENT. PSCO OBSERVED EMERGENCY PROCEDURES POSTED IN CO2 ROOM WRITTEN IN SPANISH WHEN OFFICIAL LANGUAGE OF CREW IS ENGLISH. - 74 SOLAS (2014) IX / 3.1 ISM Code Part A / 7
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 23 October 2018
Resolved
1730 - ANY SHIPS OF 400 GROSS TONS AND ABOVE SHALL BE FITTED WITH OIL FILTERING EQUIPMENT. PSCO OBSERVED INOPERABLE OILY WATER SEPARATOR. OILY WATER SEPARATOR COULD NOT PROPERLY FUNCTION DUE TO REPEATED "CLEAN MEMBRANE" ALARM. [name withheld] HAS NOT RECEIVED REQUIRED MATERIALS TO MAINTAIN OWS. - MARPOL ANNEX I / 15.6
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 23 October 2018
Resolved
1260 - OPENINGS IN FREEBOARD DECKS OTHER THAN HATCHWAYS, MACHINERY SPACE OPENINGS, MANHOLES AND FLUSH SCUTTLES SHALL BE PROTECTED BY AN ENCLOSED SUPERSTRUCTURE, OR BY A DECKHOUSE OR COMPANIONWAY OF EQUIVALENT STRENGTH AND WEATHER TIGHTNESS. PSCO OBSERVED AT LEAST 10 WINDOWS MISSING THROUGHOUT SUPERSTRUCTURE FOR THE INSTALLATION OF PORTABLE AIR CONDITIONING UNITS, COMPROMISING THE WEATHER TIGHT INTEGRITY. - ICLL ANNEX I REG. 18.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 23 October 2018
Resolved
1510 - ALL SHIPS OF 150 GROSS TONNAGE AND UPWARDS SHALL BE FITTED WITH A SPARE MAGNETIC COMPASS, INTERCHANGEABLE WITH THE MAGNETIC COMPASS. PSCO OBSERVED VESSEL COULD NOT PRODUCE A SPARE MAGNETIC COMPASS AS REQUIRED BY THE VESSEL'S SOLAS CARGO SHIP SAFETY EQUIPMENT CERTIFICATE. - 74 SOLAS (2014) V / 19.2.2.2.1
Condition: Invalid
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2018
Resolved
0830 - ALL ELECTRICAL APPARATUS SHALL BE SO CONSTRUCTED AND SO INSTALLED AS NOT TO CAUSE INJURY WHEN HANDLED OR TOUCHED IN THE NORMAL MANNER. PSCO OBSERVED LOOSE AND EXPOSED WIRING THROUGHOUT THE SHIP TO INCLUDE THE ENGINE ROOM, ON DECK, BRIDGE AND IN STATEROOMS. - 74 SOLAS (2004) II-1 / 45.1.3
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Vessel scrapped.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 21 March 2016
Resolved
0740-Pumps-Fire Fighting systems and appliances shall be kept in good working order. Main fire pump #1 has excessive leakage. 74 solas ('14 Cons) II-2/14.2.1.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2016
Resolution: Pump has been fixed, witnessed operational test with no leakage
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 21 March 2016
Resolved
0725-Fixed fire extinguishing installation-Maintenance, testing and inspections shall be carried out base on the guidlines developed by organization, vessel's fixed CO2 bottles, portable fire extinguishers, self-contained breathing apparatus and ergency escape breathing apparatus have not been inspected annually. 74 Solas ('14 Cons) II-2/Reg142.2.1, MSC.1/Circ 1432.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2016
Resolution: All firefighting equipment has been inspected by company
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 March 2016
Resolved
1730-Oily Water separator equipment-Every ship of 400 gt and above shall be fitted with oil filtering equipment. The chief engineer cannot demonstrate the proper operation of the oil water separator. MARPOL annex I/Reg.14.1
Due 21 March 2016
Resolved 21 March 2016
Resolution: Witnessed operation of OWS by Chief Engineer.
Documentation › Logs/Records › Oil Record Book
Issued 21 March 2016
Resolved
1710-Oil Record Book-Each operation (collection of oil residues)shall be fully recorded without delay in the oil record book. The weekly sounds have not been recorded as required and the quantites of the tanks have been recorded incorrectly. MARPOL annex I/Reg.17.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2016
Resolution: ORB updated, Chief engineer given training
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 17 December 2015
Resolved
0710 - The arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. Fuel oil leak detected on the No. 3 generator, which is one of the two operating generators. 74SOLAS(97) CH.II-2/Reg.15.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2015
Resolution: Flag report received and attended by USCG.
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 17 December 2015
Resolved
2550 - The company should clearly define and document the master's responsibility with regard to: verifying that specified requirements are observed. Although the Company established procedures for maintenance of the no.3 generator, the crew never conducted the required maintenance for the No. 3 generator per the ship's SMS. 74SOLAS(14)Ch.IX/Reg3.1 ISM Code Part A 5.1.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2015
Resolution: Flag report received and verified by USCG
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 17 December 2015
Resolved
The company should establish procedures to ensure that new personnel and personnel transferred to new assignments related to safety are given proper familiarization with their duties. Vessel's crew was unfamiliar with operating the portable foam extinguisher located in the engine room. 74SOLAS(14) Ch.IX/Reg3.1 ISM Code Part A 6.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2015
Resolution: Flag report received and verified by USCG
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 December 2015
Resolved
1200 - Satisfactory means (in the form of guard rails, etc.) shall be provided for the protection of the crew in getting to and from their quarters, the machinery space, and all other parts used in the necessary work of the ship. The guard rail on the FWD upper deck of the engine room has a broken rail. 66ICLL Reg.25(4)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 December 2015
Resolution: Flag report received and verified by USCG
Documentation › Certificates/Documents › IOPP Certificate
Issued 17 December 2015
Resolved
The IOPP Certificate shall be drawn up in a form corresponding to the model given in appendix II to this Annex. The IOPP Certificate does not contain the max throughput of the OWS. MARPOL Annex I Reg.9
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 December 2015
Resolution: IOPP provided
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 17 December 2015
Resolved
All lifejackets shall be provided for every person on board the ship. The vessel only had 10 approved lifejackets available, failing to meet the 18 required lifejackets as indicated on the ship's Cargo Ship Safety Equipment Certificate. 74SOLAS(97) CH.III/Reg 7.2.1
Action required: 705 - Other - as specified
Resolved 17 December 2015
Resolution: New lifejackets were brought aboard prior to Marine Inspectors departing the vessel.
Engineering › Lubricating Oil Storage/Transfer System › Drain Tank
Issued 13 August 2015
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remian fit to proceed to sea without danger to the ship or persons on board. Discharge drain for lube oil on main engine is disconnected and the disconnected side is blocked. Rubber hose being used to collect lube oil into bucket and manually poured into sludge tank.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 August 2015
Resolution: Recieved flag report from Tanzania.
Electrical › Electric Generation Source (emergency) › Generator
Issued 13 March 2014
Resolved
9900 - Other (not clearly hazardous) - A second source of energy shall be provided for each emergency generating set. Battery bank for second means of starting depleted. 74 SOLAS (04). Chap II-1. Reg. 44.2.
Action required: 705 - Other - as specified
Due 13 March 2014
Resolved 13 March 2014
Resolution: Rectified on the spot.
Fire Fighting › Fire Patrol › Call Points
Issued 13 March 2014
Resolved
0730 - Appliances (general equipment) - Any required fire alarm system with manually operated call points shall be capable of immediate operation at all times. Main deck manual call points on starboard and port side are broken and cannot be operated as intended. 74 SOLAS (97). Chapter II-2. Reg. 52.1.
Action required: 705 - Other - as specified
Due 27 March 2014
Resolved 2 April 2014
Resolution: Manual call point installed and tested to satisfaction of coast guard examiner.
Documentation › Logs/Records › Required Logbook Entries (Annex VI-Related)
Issued 13 March 2014
Resolved
1680 - Radio log (diary) - A record shall be kept to the satisfaction of the administration and as required by the radio regulations. Vessel not keeping an up to date GMDSS record. Most recent log entry dated 2011.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 April 2014
Resolution: New record started and maintain by crew.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 13 March 2014
Resolved
1570 - Nautical publications - Nautical publications shall be up to date. The IAMSAR manual is out of date.
Action required: 705 - Other - as specified
Due 27 March 2014
Resolved 1 April 2014
Resolution: Manual acquired.
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 13 March 2014
Resolved
0399 - Other (accommodation) - Sanitary accommodations shall comply with the following: cold fresh water and hot fresh water available in all wash spaces. There is no hot fresh water available on board.
Action required: 705 - Other - as specified
Due 27 March 2014
Resolved 2 April 2014
Resolution: New water heater installed.
Engineering › Steering Gear System › Ram Seal
Issued 13 February 2009
Resolved
Have administration attest to proper operation of steering system prior to departure. Mechanical seal failed in steering pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2009
Resolution: Rcvd class report stating steering pump has been replaced. The work (planned maintenance) was in progress while Inspectors were conducting the boarding.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 13 February 2009
Resolved
Have administration attest to proper operation of oily water seperator system. Content meter failed during alarm test.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2009
Resolution: Rcvd class report from BV stating. Content Meter is New MPSC 107(49). Tested satisfactory.
Construction/Loadline › Hull › Hull Plating
Issued 3 October 2008
Resolved
PSCO request an accepted, approved repair plan by class to be faxed to sector miami. Detailed plan should include time to start and estimated completion. Plan should also include total amount of work to be done . plan should be submitted to CG prior to start of work.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2008
Resolved 3 October 2008
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 3 October 2008
Resolved
Hull damage to shell plating and frames 128 and 129 in the portside focsle space. Damage has also been sustained to the shell plating at frame 119 portside Fwd Deep Tank.
Action required: 705 - Other - as specified
Due 10 October 2008
Resolved 6 October 2008
Resolution: Received class report from BV attesting to the proper repairs of the hull as presented in their repair plan submitted to the office.
Stability › Watertight Integrity › General
Issued 16 July 2008
Resolved
Vsl to remain inport until receive class report attesting to proper repairs made to crack in hull
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2008
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 23 June 2008
Resolved
OWS is not permanently set at 15 PPM. There is an adjustable dial that allows the ship to adjust the discharge rate from 0 ppm to whatever they want before it shuts off.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2008
Resolution: Recieved Class Statement
Personnel › Certificates/Documents/Licenses › License, First Assistant Engineer
Issued 23 June 2008
Resolved
Vsl does not meet minimum safe manning requirements. Vsl does not have a licensed 1rst Engineer
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2008
Resolution: Recieved Class Statement
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 23 June 2008
Resolved
Recommend 3rd party Safety Management system audit due to vsl not following SMS procedures on 20Jun2008 when the vsl lost power and did not properly notify their class and flag reps, or the Coast guard.
Action required: 705 - Other - as specified
Due 23 July 2008
Resolved 1 April 2009
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 23 June 2008
Resolved
Emergency generator doesn't supply power to main engine cooling system. Without the cooler system running the main engine automatically shuts off. Vsl can not operate with their emergency generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2008
Resolution: Recieved Class Statement
Electrical › Electric Generation Source (service) › Number of Sources
Issued 23 June 2008
Resolved
#2 generator inop. #1 & #3 are working properly
Action required: 705 - Other - as specified
Due 6 July 2008
Resolved 3 July 2008
Resolution: Recieved Class Statement
Deck/Cargo › Cargo Stowage › General
Issued 23 June 2008
Resolved
Vsl must remove al hazardous cargo from ship. Vsl doesn't have a DOC authorizing shipment of hazmat materials.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2008
Resolution: Recieved Class Statement
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 22 June 2008
Resolved
Vessel required to submit video and written report of underwater dive survey.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 March 2009
Resolution: SURVEY COMPLETED 14FEB09
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 16 April 2008
Resolved
Vsl experienced engine casualty. Exact problem is to be determined
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2009
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 16 April 2008
Resolved
Vsl lost anchor in ICW.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 March 2009
Resolution: VSL recovered anchor. certified by Class
Fire Fighting › Fire Hoses › Condition
Issued 15 April 2008
Resolved
01 fire hose forward was wasted and needed replacement.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2008
Resolution: Hose replaced and tested. Received class report attested to repairs.
Engineering › Steering Gear System › Power Unit
Issued 15 April 2008
Resolved
Vessels main steering pump #1 inoperable. Vessel required to have Class Report of proper operation of steering system prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2008
Resolution: Received Class Report attesting to proper repair and operation of associated equipment.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 15 April 2008
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2008
Resolution: Panamanian Consulate issued extension of application due to heavy backlog in issuing licenses.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 15 April 2008
Resolved
Vessels MDE inoperable. Vessel required to have Class Report attesting to proper repairs and operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2008
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 15 April 2008
Resolved
Vessel lost Port anchor due to faulty shackle while outbound ICW from Port Everglades.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2008
Engineering › Pressure Vessel › Piping
Issued 25 September 2007
Resolved
Repair hydraulic lines on starboard side cargo hatch control station.
Action required: 705 - Other - as specified
Due 1 October 2007
Resolved 5 March 2009
Resolution: hydraulic lines replaced. Verified by Class
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 24 September 2007
Resolved
Vessel is not currently documenting non conformities according to their SMS and ISM code.
Action required: 705 - Other - as specified
Due 1 October 2007
Resolved 1 April 2009
Lifesaving › Rescue Boat › Propulsion Engine
Issued 4 September 2007
Resolved
Rescue boat engine not operational. Prove proper operation of rescue boat engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 September 2007
Resolution: Rescue boat engine was repaired. PSCO witnessed proper operation of the life boat
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 6 February 2007
Resolved
Firemans outfits are outdated and missing protective items of suit. Outfits are not in compliance with FSS code.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2007
Resolution: [name withheld] attesting to the repairs and condition of vessel. No discrepancies remain outstanding. 2 SOLAS approved Fire Suits were purchased.
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 6 February 2007
Resolved
Main diesel engine jacket water leaking a steady stream from piping. Vital gears covered w/plastic to protect from running water.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2007
Resolution: [name withheld] attesting to the repairs and condition of vessel. No discrepancies remain outstanding.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 6 February 2007
Resolved
Engine room completely soaked with water from engine coolant leak and oil on deck plates. Deck grating was slippery. Excess hoses and electric cords scattered around deck. This compartment was not a safe working environment.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 February 2007
Resolved 7 February 2007
Resolution: [name withheld] attesting to the repairs and condition of vessel. No discrepancies remain outstanding.
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 6 February 2007
Resolved
6 (55 gallon drums of various petroleum materials) were attached to starboard side of main diesel engine via cargo straps. This was a potential fire safety hazard. SOLAS 2004 Consolidated I Part B Reg 11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2007
Resolution: [name withheld] attesting to the repairs and condition of vessel. No discrepancies remain outstanding.
Lifesaving › Lifebuoys › Stowage
Issued 6 February 2007
Resolved
Starboard side bridge wing lifering was not properly installed for quick release.
Action required: 705 - Other - as specified
Due 13 February 2007
Resolved 7 February 2007
Resolution: [name withheld] attesting to the repairs and condition of vessel. No discrepancies remain outstanding.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 6 February 2007
Resolved
Engine Room bilge had 2 feet of oily water coming close to the deck plates.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2007
Resolution: [name withheld] attesting to the repairs and condition of vessel. No discrepancies remain outstanding.
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 17 February 2006
Resolved
Vessel's emergency generator does not have a second source of energy.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2006
Resolution: Received report for class society (BV) regarding battery installation and testing for the emergency generator.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 February 2005
Resolved
Vessel's OWS is not working properly. Provide report attesting to the proper operation of the OWS from appropriate flag state administration to Sector Miami via fax.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 March 2005
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 15 February 2005
Resolved
Vessel's bilge level alarms are not working. Provide report from appropriate flag state administration attesting to the proper operation of the bilge alarms to Sector Miami via fax.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 March 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 15 February 2005
Resolved
There is an excessive amount of oily water in the engine room bilges. Provide receipt from approved shore facility for receiving oily water to Sector Miami via fax.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2005
Electrical › Electric Supply System (service) › Cable
Issued 13 August 2004
Resolved
Provide proper repair to deadend wiring in way of main engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 6 October 2004
Engineering › Diesel Engine (propulsion-electric) › Block
Issued 13 August 2004
Resolved
Provide cover for moving parts in generator.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 6 October 2004
Engineering › Fuel Oil Service System › Pump
Issued 13 August 2004
Resolved
Repair leak from fuel pump on main engine and clean excesive oil from leak
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 6 October 2004
Construction/Loadline › Structures
Issued 29 January 2004
Resolved
Handrails on focsle (port and starbaord) are not properly stowed. LEGACY COMPONENT DESC: Superstructure
Due 3 March 2004
Resolved 23 February 2004
Engineering › Gasoline Engine (auxiliary)
Issued 29 January 2004
Resolved
Emergency generator remote fuel shut down is damaged (missing handle.)
Due 3 March 2004
Resolved 23 February 2004
Lifesaving › Rescue Boat
Issued 28 August 2003
Resolved
Make permanent and proper repairs to deck on rescue boat. Welds are beginning to fracture on rescue boat deck, port side.
Due 15 September 2003
Resolved 26 September 2003
Electrical › Lighting (service)
Issued 28 August 2003
Resolved
Make permanent and proper repairs to starboard side deck lighting on starboard boat deck,
Due 15 September 2003
Resolved 26 September 2003
Pollution Prevention/Response › Prevention Equipment
Issued 28 August 2003
Resolved
Make permanent and proper repairs to MSD circulation piping. Piping has a leak on it. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Due 15 September 2003
Resolved 26 September 2003
Lifesaving › Lifebuoys
Issued 28 August 2003
Resolved
Replace line on starboard side lifering located on bridgewing. Line is wasted. LEGACY COMPONENT DESC: Buoyant Lifeline
Due 15 September 2003
Resolved 26 September 2003
Pollution Prevention/Response › Prevention Equipment
Issued 2 April 2003
Resolved
Replace bilge gauges in engine room (2) for OWS equipment. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 16 April 2003
Resolved 17 April 2003
Pollution Prevention/Response › Prevention Equipment
Issued 6 February 2003
Resolved
OWS not readily available for operational tests IAW MARPOL 73/78 Annex I/Reg. 16. Correct and prove proper operation to the satisfaction of the certificate issuing authority prior to next U.S. port. Maintain all oily bilge water onboard with exception to discharge to authorized reception facility. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 15 - Rectify deficiencies by next port
Resolved 2 April 2003
Fire Fighting › Structural - A Class Divisions
Issued 6 February 2003
Resolved
Emergency escape trunk fire door has wasted door frame IAW SOLAS 74/ II-2/ 45.1 LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2003
Resolved 17 April 2003
Documentation › Logs/Records
Issued 6 February 2003
Resolved
Garbarge record book not maintained properly IAW MARPOL 73/78 Annex V/ Reg. 9. Provide proof of compliance at end of 3-month period to the satisfaction of USCG inspector. LEGACY COMPONENT DESC: Garbage Recordkeeping
Due 6 May 2003
Resolved 2 April 2003
Electrical › Lighting (service)
Issued 6 February 2003
Resolved
Lighting fixtures throughout the vessel are missing protective guards and globes; exposed dead-end wirings IAW SOLAS 74/ II-1/ 45.1.3. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 16 April 2003
Resolved 17 April 2003
Fire Fighting › Structural Fire Protection - General
Issued 6 February 2003
Resolved
Steel overhead in air conditioning room wasted, compromising fire integrity IAW SOLAS 74/ II-2/ 44. LEGACY COMPONENT DESC: Structural Bulkhead Construction
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2003
Resolved 2 April 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 6 February 2003
Resolved
Engine room in need of proper housekeeping i.e. oily deck plates, bulkheads and other spaces in engine room IAW ILO 147.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2003
Resolved 17 April 2003
Lifesaving › Inflatable Liferafts
Issued 6 February 2003
Resolved
Liferaft launching instructions not posted IAW SOLAS 74/ III/ 9.2.
Due 6 March 2003
Resolved 2 April 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 6 February 2003
Resolved
Portable freezer obstructing main deck, portside, next to galley entrance IAW ILO 147.
Due 6 March 2003
Resolved 2 April 2003
Electrical › Lighting (service)
Issued 28 August 2002
Resolved
The ship was missing some light fixture covers in the engine room. LEGACY COMPONENT DESC: Lighting Fixture
Due 28 September 2002
Resolved 7 November 2002
Electrical › Electrical Distribution System (emergency)
Issued 28 August 2002
Resolved
The ship is using the space behind the main switch board as a storage space. LEGACY COMPONENT DESC: Panelboard
Due 28 September 2002
Resolved 7 November 2002
Lifesaving › Rescue Boat Equipment
Issued 30 January 2002
Resolved
Repair davit lauched system winch. Surveyor to provide report of proper operation.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2002
Resolution: Lloyds surveyor G. Taylor provided fax dated 21 Dec 01 - rescue boat winch has been repared.
Accommodation/Occupational Safety › Occupational Safety
Issued 30 January 2002
Resolved
Install coupling guard for emergency fire pump located fwd. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2002
Resolution: 21Dec 01Repair electric davit top, rescue boat & provide Lloyds surveyor provided report of installed guard rail.
Accommodation/Occupational Safety › Occupational Safety
Issued 30 January 2002
Resolved
Install engine room explosion proof light covers. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 30 January 2002
Resolution: Lloyds surveyor provided report attesting to replacement of light fittings in engine room.
Fire Fighting › Fire Hoses › Connections
Issued 30 January 2002
Resolved
Two fire hoses clamps where lost during drill; clamps can not be adjusted "tightened" by crew member. Have surveyor provide U.S.C.G. report.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2002
Resolved 30 January 2002
Fire Fighting
Issued 13 February 1997
Resolved
Properly label the following: Paint locker sprinkler sytem controls, Engine Room and Cargo Hold CO2 rooms. To be completed prior to departure.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Fire Fighting
Issued 13 February 1997
Resolved
Properly repair the leaking valve connection for the paint locker sprinklersystem supply line. To be completed prior to departure.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Documentation
Issued 13 February 1997
Resolved
Provide a valid/accurate Cargo Ship Safety Radio Certificate issued by the vessels Classification Society. To be completed prior to departure.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Fire Fighting
Issued 13 February 1997
Resolved
Provide the following for the Bow fire station: adequate length of 1.5" fire hose, nozzle and a spanner wrench. To be completed prior to departure.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Documentation
Issued 13 February 1997
Resolved
Provide a valid 2nd Engineers License as per the Safe Manning Certificate. To be completed prior to departure.
Condition: Unknown
Due 9 May 1997
Resolved 14 June 1997
Accommodation/Occupational Safety
Issued 13 February 1997
Resolved
Properly repair damaged/missing railing on starboard bow, forecastle deck. To be completed prior to returning to U.S. waters.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Electrical
Issued 13 February 1997
Resolved
Prpoerly repair/mount the light switch located in the Fore-Peak entrance onthe Forecastle Deck. To be completed prior to returning to U.S. waters.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Fire Fighting
Issued 13 February 1997
Resolved
Properly connect all CO2 bottles designated for the Cargo Hold. Have system properly serviced and provide the servicing certificate. To be completed prior to loading any cargo.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Fire Fighting
Issued 13 February 1997
Resolved
Replace/renew the CO2 discharge piping on the main deck designated for the cargo hold. To be completed prior to loading any cargo.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Unknown
Issued 13 February 1997
Resolved
Provide plugs for all on deck containment drains. To be completed prior tobunkering.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Lifesaving
Issued 13 February 1997
Resolved
Provide an operable waterlight for the ring buoy on the starboard side liferaft deck. To be completed prior to departure.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Lifesaving
Issued 13 February 1997
Resolved
Replace all four hydro-static releases for the liferafts. To be completed prior to departure.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Lifesaving
Issued 13 February 1997
Resolved
Prove proper operation of the rescue boat engine. To be completed prior todeparture.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Electrical
Issued 13 February 1997
Resolved
Provide protective cover for the light fixture located at the Fore-Peak entrance on the Forecastle deck. To be completed prior to returning to U.S. waters.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Construction/Loadline
Issued 13 February 1997
Resolved
Provide gaskets for the following weather-tight doors: Fore-Peak entrance on the main deck, paint locker, cargo hold CO2 room, and the emergency generator room. To be completed prior to departure.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Documentation
Issued 12 March 1995
Resolved
THE VESSEL IS TO PROVIDE MEDICAL CERTIFICATES FOR ALL MEMBERS OF THE CREW.
Condition: Unknown
Due 11 April 1995
Resolved 11 April 1995
Fire Fighting
Issued 12 March 1995
Resolved
THE VESSEL IS TO ENSURE THATH ALL HOSE STATIONS ARE PROPERLY EQUIPPED AT ALL TIMES.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Navigation
Issued 3 August 1989
Resolved
A VIOLATION OF 33 CFR 164.30 IN THAT THE MOST CURRENT ED. OF U.S. TIDAL CURRENT TABLES, OR IT'S FOREIGN EQUIVALENT, AS REQ BY 164.33(A)(3)(II), WERE NOT O/B VSL. THE VSL HAD O/B U.S. TIDAL CURRENT TABLES DTD 1988 WHEREAS CURRENT EDITION IS DTD 1989.
Condition: Unknown
Due 3 August 1989
Resolved 3 August 1989
Navigation
Issued 3 August 1989
Resolved
A VIOLATION OF 33 CFR 164.30 IN THAT VSL HAD U.S. CHARTS 11466 AND 11468 O/B WHICH WERE NOT CORRECTED UP THROUGH NTM 30/89 WHICH HAD CORRECTIONS FORBOTH CHARTS. VSL HAD NTM 30/89 O/B AT TIME OF INSPECTION AND DID NOT PROVIDE FOREIGN EQUIVALENT. NO OTHER CHART CORRECTION RECORD PRODUCED.
Condition: Unknown
Due 3 August 1989
Resolved 3 August 1989
Navigation
Issued 3 August 1989
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 3 August 1989
Resolved 3 August 1989
Navigation
Issued 3 August 1989
Resolved
A VIOLATION OF 33 CFR 164.30 IN THAT VESSEL WAS OPERATING WITH A LIGHT LISTTHAT DID NOT CONTAIN AIDS TO NAVIGATION WHICH WERE LOCATED WITHIN THE VSL'SROUTE FROM THE PORT OF MIAMI SEABUOY TO THE VESSEL'S BERTH IN THE MIAMI RIVER.
Condition: Unknown
Due 3 August 1989
Resolved 3 August 1989
Navigation
Issued 20 July 1988
Resolved
PRE ARRIVAL TESTS NOT LOGGED IN VESSELS LOGS.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Navigation
Issued 20 July 1988
Resolved
VESSEL DID NOT HAVE TIDAL CURRENT TABLES ONBOARD.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Documentation
Issued 20 July 1988
Resolved
VESSELS OIL TRANSFER PROCEDURES CONTAINED ONLY A LINE DIAGRAM. VESSELS OIL CAPACITY IS 505 CU.MTS..
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Navigation
Issued 20 July 1988
Resolved
CHART NO.11466, JAN85 AND NO.11460 22FEB86 WERE NOT UPDATED; ALSO THERE WAS NO OTHER RECORDS OF CHART CORRECTIONS PROVIDED.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988