CHICAMACOMICO

CHICAMACOMICO is a 1989 passenger vessel (inspected). The Coast Guard has recorded 76 inspections since 2016, most recently in July 2026, along with 63 deficiencies — 2 with no resolution recorded — and 38 casualty investigations between 2005 and 2026.

Records from 2005 to 2026. Most recent: inspection, 2 July 2026.

Built
1989
Last inspected
2 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 July 2026
…with no type recorded11
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8645325
WAH3959
331133
Flag
UNITED STATES
Maury page id
psix-331133

Documentation record

Registered dimensions (L × B × D)140.3 ft × 42.1 ft × 7.5 ft
Registered tonnagegross 276 / net 187
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPATTI SHIPYARD, INC. · PENSACOLA, FL, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMANNS HARBOR, NC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it276 - Regulatory (Subpart C or D), Gross Ton
187 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SC170 Freight Barge · MISLE 23787 · 16 April 2022 · activity 7438800LITTLE NANCY Towing Vessel · MISLE 841482 · 16 April 2022 · activity 7438800RANGER Towing Vessel · MISLE 925216 · 16 April 2022 · activity 7438800LITTLE MARY Towing Vessel · MISLE 1144713 · 16 April 2022 · activity 7438800

Inspection history · 76

2 July 2026 Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8426099
24 June 2026 Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8413091
20 May 2026 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8377542
23 April 2026 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8354870
23 April 2026 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8355394
15 April 2026 Administrative Inspection · Appeal
Administrative · USCG East District · USCG East District (CGD-E) · Activity 8349836
5 February 2026 Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8270600
2 January 2026 Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8289314
2 January 2026 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 8291528
6 November 2025 Re-Inspection · Examination of Repairs · Deficiency Check · Vessel Attendance
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8230466
14 August 2025 COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8187296
7 August 2025 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8204871
26 July 2025 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8195205
7 May 2025 Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8131622
13 February 2025 Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8078527
21 November 2024 Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8038525
27 August 2024 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7990116
14 August 2024 MTSA Verification · COI Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7974558
16 April 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7972588
10 May 2023 Administrative Inspection · Special Consideration
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7694000
29 March 2023 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7658302
2 February 2023 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7631259
26 January 2023 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7627435
3 December 2022 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7604834
2 November 2022 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7587511
24 September 2022 Special
Type not classified · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7565319
19 July 2022 MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7505466
16 June 2022 Special
Type not classified · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7480221
27 April 2022 Deficiency Check · MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7438638
16 April 2022 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7438800
12 April 2022 Special · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7429597
12 April 2022 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7433876
30 March 2022 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7423074
30 March 2022 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7424532
1 March 2022 Special · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7404689
1 March 2022 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7409724
7 February 2022 Deficiency Check · Special
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7391782
6 February 2022 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7404361
27 January 2022 Special
Type not classified · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7390143
20 January 2022 Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7381829
8 November 2021 Special
Type not classified · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7347399
28 October 2021 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7340806
27 July 2021 COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7269141
19 February 2021 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7142777
30 March 2020 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6934614
18 February 2020 Deficiency Check · Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6925530
19 January 2020 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6897631
23 August 2019 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6808375
19 August 2019 Administrative Inspection · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6788756
21 May 2019 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6750475
11 April 2019 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6690899
27 March 2019 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6653435
24 January 2019 Special · MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6614485
28 November 2018 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6588401
9 September 2018 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6563750
24 August 2018 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6521723
1 August 2018 Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6531403
22 July 2018 Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6489504
22 July 2018 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6553322
15 July 2018 Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6482283
15 July 2018 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6490217
6 June 2018 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6436792
24 April 2018 COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6398074
28 September 2017 Hull Examination · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6281142
27 July 2017 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6234088
14 June 2017 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6177095
25 May 2017 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6162712
25 May 2017 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6220180
14 February 2017 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6087970
17 November 2016 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6046499
15 November 2016 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6041217
14 November 2016 COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6040656
9 September 2016 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5999530
23 June 2016 Special · Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5916593
6 June 2016 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5898674
17 February 2016 Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5791099

Deficiency record · 63

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 June 2026 Resolved
Where extinguishing systems or equipment are not required, but are installed, the system or equipment and its installation must meet the requirements of this part. The locking pin for clutch adjustment spanner nut broke on the starboard fire pump PTO. Make necessary repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2026
Resolved 6 July 2026
Resolution: NCDOT Ferry Division Maintenance replaced the locking pin for the starboard fire pump PTO. Tested satisfactory. The starboard fire pump PTO is operating as designed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 April 2026 Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Marine Vessel Rules. MI observed a fuel oil leak on the emergency generator racor fuel filter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2026
Resolved 30 April 2026
Resolution: NCDOT mainenance rectified the cause of the leak. There is no longer a fuel oil leak on the emergency generator racor fuel filter.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 April 2026 Resolved
Approved hand portable fire extinguishers and semiportable fire extinguishing systems shall be installed on all vessels as set forth in subpart 76.50. MI observed the AFT Port quarter fire extinguisher on the vehicle deck is broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2026
Resolved 30 April 2026
Resolution: The fire extinguisher bracket was repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 5 February 2026 Resolved
Navigation light. Each rescue boat must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules and meet 46 CFR 111.75-17. MI observed that the white light on the aft port quarter was not working.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2026
Resolved 17 February 2026
Resolution: Light has been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 2 January 2026 No resolution recorded
The rescue boat launching and recovery arrangement does not comply with 46 CFR 199.160(e) and 199.160(g) because the installed 1,500-lb davit cannot recover the rescue boat with its full complement of persons and equipment; NCDOT must either upgrade the rescue boat/davit system to full regulatory compliance or obtain an approved exemption from CGD East in accordance with 46 CFR § 199.20(d) prior to return to service following the next scheduled drydock.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 June 2026 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 August 2025 No resolution recorded
All marine engineering details, such as boilers, pressure vessels, main and auxiliary machinery, piping, valves, and fittings, must be designed, constructed, and installed in accordance with the provisions of this sub chapter. MI observed that the weld on the steering hydraulic tank are broken. Request temporary and permanent repair plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 August 2025 Resolved
Nonmetallic flexible hose may be used in lube oil, fuel oil and fluid power systems only where flexibility is required and in lengths not exceeding 30 inches. MI observed diesel fuel oil supply and return fuel lines are dry rotted and cracking. Install new diesel fuel oil supply and return fuel lines.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2025
Resolved 9 September 2025
Resolution: Fuel hoses were repaired and installed as manufacturer specifications
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 August 2025 Resolved
Each Class 1 door must have a quick action closing device operative from both sides of the door. MI observed the gasket seal on the E/R watertight door is dry rotted and cracking. Replace gasket seal on the E/R watertight door.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2025
Resolved 9 September 2025
Resolution: Door gasket was replaced
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 14 August 2025 Resolved
Each self-propelled vessel, except as provided in paragraph (d) of this section, must have an electric or mechanical engine order telegraph system from the navigating bridge to the engine room. MI observed the EOT on the bridge was not working. Repair engine order telegraph to satisfaction of the attending Marine Inspector
Action required: 10 - Deficiency Rectified
Resolved 14 August 2025
Resolution: Engine order telegraph was repaired to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 August 2024 Resolved
An inspection, either general or partial depending upon the circumstances, shall be made whenever any important repairs or alterations are undertaken. Make effective repairs on stbd shaft mechanical seal and prove proper operation to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2024
Resolution: Shaft seal was reset to manufactures tolerances. Verified with calibrated gauges.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 14 August 2024 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and dangerous places such as gears, machinery, etc. Inboard air compressor belt guard missing bolt and was loose. Conduct repairs to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2024
Resolved 23 August 2024
Resolution: Added new bolt for gaurd and tightened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 August 2024 Resolved
The inspections and tests shall insure that the equipment and associated structure are in satisfactory operating conditions and fit for the service for which they are intended. STBD main engine control in EOS was found inoperable. Make effective repairs and prove proper operation to the satisfaction of attending CG Maine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2024
Resolved 23 August 2024
Resolution: New throttle installed and adjusted to manufactures set point.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 August 2024 Resolved
Each individual bilge suction shall be fitted with a suitable bilge strainer having an open area of not less than three times at of the suction pipe. Port steering bilge suction missing strainer. Replace missing strainer.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2024
Resolved 23 August 2024
Resolution: New strainer installed on bilge piping.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 August 2024 Resolved
The emergency lighting and power loads must be arranged so that they can be energized from the temporary emergency power source: b) Enough lights throughout machinery spaces to allow essential operations and observations under emergency conditions and to allow restoration of service. One of the emergency lights in EOS is inoperable. Make repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2024
Resolved 23 August 2024
Resolution: New light bulb was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 August 2024 Resolved
The regulations in this part contain requirements for the design and construction of main and auxiliary machinery installed on vessels. Bracket for port bilge suction piping in #5 void was broken. Make repairs to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2024
Resolved 23 August 2024
Resolution: Broken bracket was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 August 2024 Resolved
t each inspection for certification and periodic inspection the marine inspector shall conduct such tests and inspections of the main propulsion of its associated equipment as he feels necessary to check safe operation. Port MDE did not shutdown on low L/O IAW approved PSTP’s. Conduct repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2024
Resolved 23 August 2024
Resolution: New sensor for shutdown was installed and proved proper operation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 August 2024 Resolved
For each watertight door which is in a required subdivision bulkhead, an indicator light must be installed in the pilothouse and at each other vessel operating station from which the door is not visible. The panel in the pilothouse was not working. Make repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2024
Resolved 15 August 2024
Resolution: New power supply was installed for the panel with watertight door indicator lights. Several bulbs were replaced with new. Tested all indicators to verify all lights work. Tested both watertight doors. Test SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 January 2023 Resolved
#1 SSDG has front plate oil leak at approximately 01 drip every 5 seconds. Make permanent repairs to the satisfaction of Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2023
Resolved 2 February 2023
Resolution: NCDOT maintenance crew replaced several o-rings SSDG fuel injection pump. #1 SSDG no longer has a persistent oil leak, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 3 December 2022 Resolved
Each fall used for launching appliances must be renewed when necessary due to deterioration or at an interval of no more than every five years, whichever is earlier. Upon internal inspection the vessel's davit cable was found frayed and unserviceable. Renew cable and perform satisfactory tests prior to taking passengers. 46CFR199.190(J)(ii)
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 December 2022
Resolved 5 December 2022
Resolution: NCDOT submitted objective evidence of proper cable installation and testing. All Sat. Updated vessel COI to reflect the replacement of the davit cable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 September 2022 Resolved
MI notified of limited details of piping failure to number 1 bilge system. Make permanent repairs prior to carrying passengers. Complete repairs and testing to satisfaction of attending Marine Inspector as per 46CFR56.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 September 2022
Resolution: NCDOT maintenance tapped threads to pump housing for aux. pump hose and installed new pipe with valve. System was tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2022 Resolved
Update PSTP for 4.0 transmission temp sensor. System not alarming IAW current test procedures. Update in accordance with 46CFR62.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2022
Resolved 22 July 2022
Resolution: Minor change to add one step MI.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 July 2022 Resolved
Overhead heat sensor in E-Gen space was not operational. Replace in accordance with 46CFR72.
Action required: 10 - Deficiency Rectified
Due 19 July 2022
Resolved 19 July 2022
Resolution: Heat sensor replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2022 Resolved
EOT is not operational in the control room. Provide tech report of PSTPs completed and captain's attestation of thier proper operation in accordance with 46CFR113.35.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2022
Resolved 22 July 2022
Resolution: Bad power card, replaced completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 July 2022 Resolved
01 PFD found unservicable replace and stow in main deck storage in accordance with 46CFR199.70(B).
Action required: 10 - Deficiency Rectified
Due 19 July 2022
Resolved 20 July 2022
Resolution: PFD replaced and stowed properly, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 June 2022 Resolved
Operator reported that the starboard main engine had a reduction of rpms while underway for an unknown reason. Provide causal factors attributing to cause and corrective actions taken to rectify. Vessel must be cleared by a marine inspector from this office before returning to service.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 June 2022
Resolved 1 July 2022
Resolution: SAT Sea Trails conducted.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 27 April 2022 Resolved
Oil discharge piping cracked at elbow on main deck. Make permeant repairs as per discussed plan and iaw 46CFR97.30.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 27 May 2022
Resolution: Piping welded SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 April 2022 Resolved
#2 SSDG overspeed is at 1445. Set to proper RPM IAW approved PSTPs. Repair in accordance with 46CFR111.30.
Action required: 10 - Deficiency Rectified
Due 27 April 2022
Resolved 27 April 2022
Resolution: Overspeed alarm set to proper RPM IAW ships PSTPs
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 April 2022 Resolved
Main switch board AMP meter switch broken off, switch can be switched and modified until new switch arrived. Repair in accordance with 46CFR111.30.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 27 May 2022
Resolution: New switch installed and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 April 2022 Resolved
#2 SSDG has broken bolt on expansion tank repair iaw 46CFR58.
Action required: 10 - Deficiency Rectified
Due 28 April 2022
Resolved 28 April 2022
Resolution: bolt repaired.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 27 April 2022 Resolved
Emergency generator breaker has a broken placement tab. Tested transfer of power 04 times, all sat. Repair iaw 46CFR111.30.
Action required: 10 - Deficiency Rectified
Due 27 April 2022
Resolved 27 April 2022
Resolution: Placement tab repaired.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 12 April 2022 Resolved
Vessel operator reported that the stb main engine was experiencing low fuel pressure alarms while approaching Ocracoke. Provide causal factors contributing to the cause of low fuel pressure and corrective actions taken to resolve the issue. Prior to being put back into service, vessel must be cleared by a marine inspector from this office.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2022
Resolved 12 April 2022
Resolution: Low fuel pressure alarm was due to a failed sensor. Sensor was replaced and tested without error.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 March 2022 Resolved
MI notified by NCDOT that the STBD sea chest a/c and firemain line leaking sea water. Removed piping after isolating for internal inspection. Make permanent reapir and contact local MI for visual inspection and NDT. All repairs are to be made to the satisfaction of attending [name withheld] 46CFR70.20-1.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2022
Resolution: New piping installed and tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 March 2022 Resolved
Vessel crew reported fuel leak on the Starboard MDE, make repairs and test to the satisfaction of the attending Marine Inspector iaw 46 CFR 58.05-1.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2022
Resolution: Replaced fuel line ops test SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 February 2022 Resolved
Make permanent repairs to port side tiller arm yoke due to yoke weld failure. All repairs must be to satisfaction of attending marine inspector. MI will need to verify fit up, visual weld inspection and nondestructive testing, and operational testing prior to placing vessel back into service as per 46CFR58.25.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2022
Resolved 15 February 2022
Resolution: Inspected new port side tiller arm yoke, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 January 2022 Resolved
Port and STBD shaft bilge pumps missing hose clamps. Replace/repair in accordance with 46CFR56.50-50.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2022
Resolved 16 February 2022
Resolution: Hose clamps installed on pump hose, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 January 2022 Resolved
#1 SSDG overspeed 1600 RPM adjust to 1552 RPM as per PSTP in accordance with 46CFR111.12-11.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 January 2022
Resolved 20 January 2022
Resolution: Overspeed alarm adjusted, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 20 January 2022 Resolved
Rescue boat retro on bottom is peeling. Replace in accordance with 46CFR70.28-1.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2022
Resolved 16 February 2022
Resolution: Retro applied to bottom of rescue boat, all sat.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 20 January 2022 Resolved
Fuel vent closer is missing a wing nut. Replace in accordance with 46CFR71.25-1.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 January 2022
Resolved 20 January 2022
Resolution: Wing nut replaced, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 January 2022 Resolved
Lower stern light has damaged wiring. Repair in accordance with 46CFR70.25-1.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2022
Resolved 16 February 2022
Resolution: Wiring replaced on stern light, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 20 January 2022 Resolved
Rescue boat door hold back is missing, broken off. Repair in accorance with 46CFR70.28-1.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2022
Resolved 7 February 2022
Resolution: Repaired hold back, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 November 2021 Resolved
DD Nags Head received report that vessel had been removed from service due to a fuel leak on the return line for the emergency generator. Conduct full examination of all associated fuel lines and make necessary repairs iaw 46 CFR 110.01-3. Vessel is permitted one-time transit to NCDOT Shipyard in Manns Harbor to effect repairs as needed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2021
Resolution: Fuel piping cropped and renewed, all test sat following repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 October 2021 Resolved
STBD MDE exhaust lagging is damaged. Replace IAW 46CFR58.60.13
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 22 November 2021
Resolution: Lagging was removed and repositions and patch put over holed area and reinstalled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 October 2021 Resolved
#1 generator expansion tank supply hose is damaged. Replace IAW 46CFR58.30-20
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 22 November 2021
Resolution: New hose installed port and STBD engine.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 16 March 2020 Resolved
Drills, musters, and training sessions shall be properly logged IAW 46 CFR 199.180(h).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2020
Resolved 30 March 2020
Resolution: Drills logged.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 16 March 2020 Resolved
Conduct fire and abandon ship drills in the presence of the USCG as part of Certificate of Inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2020
Resolved 18 March 2020
Resolution: USCG Marine Inspector attended to witness drills. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 March 2020 Resolved
Fire pump relief valve is inoperable. Vessel class has known/documented issue with over-pressurization. Make necessary repairs prior to completion of next scheduled drydock set for 31MAY2020.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 30 July 2021
Resolution: Relief valve tested sat, vessel made approved modifications for over-pressurization issues that were verified during fire hose tests.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 March 2020 Resolved
Replace hose on fixed CO2 system in e-gen space prior to completion of next scheduled drydock set for 31MAY2020.
Action required: 705 - Other - as specified
Resolved 30 July 2021
Resolution: Hose replaced sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 March 2020 Resolved
Fuel line for e-gen is non-approved type. Replace prior to completion of next scheduled drydock set for 31MAY2020.
Action required: 705 - Other - as specified
Resolved 30 July 2021
Resolution: Fuel line replaced sat.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangements rescue boats
Issued 19 January 2020 Resolved
Vessel sustained damage to the rescue boat embarkation ladder and door. Repair damaged items.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2020
Resolved 7 February 2020
Resolution: The new ladder and door have been installed; all sat.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 14 February 2019 Resolved
Witnessed excessive leaking on stbd rudder post. Repair
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 11 April 2019
Resolution: Vessel completed repairs; op test sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 14 February 2019 Resolved
Witnessed minor leaks on multiple flush deck hatches. Make hatches watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2019
Resolved 27 March 2019
Resolution: Witnessed hose test of all flushdeck hatches; sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 November 2018 Resolved
Repair leak in fire pump overboard discharge piping to satisfaction of attending Coast Guard inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2018
Resolved 19 August 2019
Resolution: Fire pump overboard discharge piping found to be without leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 November 2018 Resolved
Found excessive leak in port side rudder packing gland. Make proper repairs to satisfaction of attending Coast Guard Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2018
Resolved 6 December 2018
Resolution: Adjusted packing gland; sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 July 2018 Resolved
Found a leaking low pressure fuel line on the stbd MDE. Replace fuel line.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 July 2018
Resolution: Installed new fuel line.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 15 July 2018 Resolved
During a man overboard drill, the davit/winch control cable became tangled with the davit turn table which pulled the davit/winch control wiring loose and caused a fuse to blow. Repair/replace loose wiring and fuse in kind and demonstrate full function test of rescue boat davit to the satisfaction of an attending CG Marine Inspector, prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2018
Resolution: Examined installation of new controller wire and witnessed operational test; all sat.
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 June 2018 Resolved
Found holed cooling water line between the cooling water pump and vessel shaft seals. Replace in kind and make available for hydrostatic testing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2018
Resolved 6 June 2018
Resolution: Verified holed cooling line was replaced in kind. Witnessed hydrostatic test of new line to 50 p.s.i.
Fire Fighting › Fire Main › Condition
Issued 27 July 2017 Resolved
A crack was found in #1 fire pump suction between the sea strainer and the pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 31 July 2017
Resolution: A new spool piece was installed and tested.
Engineering › Steering Gear System › Motor
Issued 14 June 2017 Resolved
Integrated cooling fan blade in the #2 steering pump failed causing the steering alarm to activate. Repair or replace #2 steering pump motor.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2017
Resolution: A new fan blade was installed.
Stability › Watertight Integrity › General
Issued 14 November 2016 Resolved
Found all flush deck hatches missing securing device to prevent loss. Attach chain, lanyard, etc. to prevent loss.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 17 November 2016
Resolution: Discussed with sector NC and IAW CFR there is noe requirement for H boats.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 14 November 2016 Resolved
Unable to test prime mover safety devices on EDG. Demonstrate safety devices.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 17 November 2016
Resolution: Demonstated safety devices.
Engineering › Bilge Water Management System › Strainer
Issued 14 November 2016 Resolved
Found bottom cover missing on aft engine room bilge suction strainer. Install cover and test system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 17 November 2016
Resolution: Installed new cover on bilge strainer.
Engineering › Bilge Water Management System › Piping
Issued 9 September 2016 Resolved
Found temporary epoxy repair on the bilge piping in void 5 srevicing the steering compartment. Renew damaged piping.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2016
Resolved 12 September 2016
Resolution: Corroded section of pipe was replaced.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 9 September 2016 Resolved
Unable to conduct man overboard drill.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2016
Resolved 12 September 2016
Resolution: Conducted satisfactory drill.

Casualty record · 38

27 July 2005Routine · role: Involved in a Marine Casualty · activity 2470954
5 October 2005Routine · role: Involved in a Marine Casualty · activity 2508415
2 April 2006Routine · role: Involved in a Marine Casualty · activity 2621785
30 April 2006Routine · role: Involved in a Marine Casualty · activity 2637725
19 July 2006Routine · role: Involved in a Marine Casualty · activity 2719040
2 September 2006Routine · role: Involved in a Marine Casualty · activity 2769056
25 November 2007Routine · role: Involved in a Marine Casualty · activity 3104728
9 April 2008Routine · role: Involved in a Marine Casualty · activity 3180713
29 July 2008Routine · role: Involved in a Marine Casualty · activity 3283879
29 June 2009Routine · role: Involved in a Marine Casualty · activity 3519027
15 July 2009Routine · role: Involved in a Marine Casualty · activity 3536555
7 May 2010Routine · role: Involved in a Marine Casualty · activity 3740602
15 June 2010Routine · role: Involved in a Marine Casualty · activity 3767492
18 June 2010Routine · role: Involved in a Marine Casualty · activity 3772271
19 September 2010Routine · role: Involved in a Marine Casualty · activity 3853959
5 November 2010Routine · role: Involved in a Marine Casualty · activity 3885792
16 April 2011Routine · role: Involved in a Marine Casualty · activity 3990931
30 August 2011Routine · role: Involved in a Marine Casualty · activity 4131817
16 October 2011Routine · role: Involved in a Marine Investigation (non-casualty) · activity 4169538
25 September 2012Routine · role: Involved in a Marine Casualty · activity 4450450
28 September 2012Routine · role: Involved in a Marine Casualty · activity 4452424
5 October 2012Routine · role: Involved in a Marine Casualty · activity 4459824
7 October 2012Routine · role: Involved in a Marine Casualty · activity 4459880
17 November 2012Routine · role: Involved in a Marine Casualty · activity 4488383
8 February 2013Routine · role: Involved in a Marine Casualty · activity 4531718
25 November 2013Routine · role: Involved in a Marine Casualty · activity 4771355
27 November 2013Routine · role: Involved in a Marine Casualty · activity 4760812
25 May 2017Routine · role: Involved in a Marine Casualty · activity 6220180
15 July 2018Routine · role: Involved in a Marine Casualty · activity 6490217
22 July 2018Routine · role: Involved in a Marine Casualty · activity 6553322
9 September 2018Routine · role: Involved in a Marine Casualty · activity 6563750
23 August 2019Routine · role: Involved in a Marine Casualty · activity 6808375
6 February 2022Routine · role: Involved in a Marine Casualty · activity 7404361
1 March 2022Routine · role: Involved in a Marine Casualty · activity 7409724
30 March 2022Routine · role: Involved in a Marine Casualty · activity 7424532
12 April 2022Routine · role: Involved in a Marine Casualty · activity 7433876
16 April 2022Routine · role: Involved in a Marine Casualty · activity 7438800
23 April 2026Routine · role: Involved in a Marine Casualty · activity 8355394
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.