Records from 2012 to 2026. Most recent: inspection, 31 March 2026.
Documentation record
Registered dimensions (L × B × D)72.0 ft × 28.0 ft × 7.3 ft
Registered tonnagegross 98 / net 78
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPORTIER SHIPYARD INC · CHAUVIN, LA, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCHESAPEAKE, VA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 25 November 2025 · expires 31 December 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it78 - Simplified, Net Ton
98 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 25
31 March 2026
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8338863
8 January 2026
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8292190
13 December 2025
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8283172
13 December 2025
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8354821
19 December 2024
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8049787
10 October 2024
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8096100
14 March 2024
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7879333
11 July 2023
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7824432
27 July 2022
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7517648
16 April 2022
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7438800
18 December 2021
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7370534
18 December 2021
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7370662
16 January 2021
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7126020
13 October 2020
Initial Certification · Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7076333
5 February 2020
Examination of Repairs · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6902275
31 January 2020
Permit to Proceed
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6901811
31 January 2020
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7023138
15 October 2019
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6835392
15 October 2019
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6837085
30 September 2019
TPO Audit
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6824702
17 September 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6814108
16 May 2019
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6685852
20 August 2015
Administration · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5215979
19 November 2013
Risk-based Targeted Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4755296
8 August 2012
Deficiency Check · DAPI Audit · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4406166
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 January 2020
Resolved
Vessel experienced a marine casulaty and damaged the starboard rudder from grounding. Conduct repairs to the satisfaction of the attending USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2020
Resolved 6 March 2020
Resolution: CGMI attended vessel, oversaw repairs, and vessel conducted sea trail; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2019
Resolved
Gasket blew on starboard main.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 October 2019
Resolved 17 October 2019
Resolution: Operational test conducted in the presence of inspector, all sat
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 September 2019
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exist. The following alarms must be provided:(5) High bilge levels. No bilge alarms are present.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2019
Resolved 20 September 2019
Resolution: Vessel installed operational bilge alarm and tested in the presence of Marine Inspector with satisfactory results.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2019
Resolved
Electrical equipment that pose an electrical shock hazard must be in an enclosure. Multiple electrical panels are missing circuit breaker blanks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2019
Resolved 20 September 2019
Resolution: Vessel installed Circuit Breaker Blanks all panels inspected by CG Marine Inspector with Satisfactory results.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 September 2019
Resolved
Machinery and electrical systems must be designed and maintained to provide safe operation. Missing belt guards on the front of both SSDG's
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2019
Resolved 25 February 2021
Resolution: Machinery Guards installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 September 2019
Resolved
A record of the type, size, and service of each towline, face wire, and spring line, used to make the tow, must be available to Coast Guard. The required examination were not available and per TSMS.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2019
Resolved 25 February 2021
Resolution: Record of type, size and serivce is onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 September 2019
Resolved
The operator of a vessel with a capacity of 250 or more barrels of oil, shall provide transfer procedures that meet the requirements of this part. Vessel has a capacity of 25,944 gal and no transfer procedures onboard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2019
Resolved 25 February 2021
Resolution: Transfer procedures onboard.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 17 September 2019
Resolved
The TSMS must include the elements listed in paragraphs (a) through (d) of this section. Company does not have a TSMS culture in place that complies with TSMS elements mandated by the applicable CFRs; nor does it currently implement procedures to ensure compliance with operational and equipment requirements.
Per the findings from the post casualty inspection on 17 Sept 2019 and reports submitted by company. Per CG-CVC policy letter 17-10 6.a. the owner, managing operator or TPO shall notify the local OCMI of any unsafe condition or major non-conformity and discuss procedures for correcting such an item in accordance with approved TSMS.
The bilge high-water alarm required by this part was identified missing from vessel on 25 July 2019 (major non-conformity)yet no Corrective action per TSMS was conducted, and OCMI was not notified.
A follow on audit conducted in August failed to address this item and that report indicated vessel was compliant.
A detailed external management audit must be performed paying specific attention to 46 CFR 138.220 parts (a) & (d).
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2019
Resolved 8 October 2019
Resolution: TPO Decatur Marine completed targeted audit at Intercoastal Marine and issued a report
15 October 2019Routine · role: Involved in a Marine Casualty · activity 6837085
31 January 2020Routine · role: Involved in a Marine Casualty · activity 7023138
16 January 2021Routine · role: Involved in a Marine Casualty · activity 7126020
18 December 2021Routine · role: Involved in a Marine Casualty · activity 7370662
16 April 2022Routine · role: Involved in a Marine Casualty · activity 7438800
11 July 2023Routine · role: Involved in a Marine Casualty · activity 7824432
10 October 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 8096100
13 December 2025Routine · role: Involved in a Marine Casualty · activity 8354821
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source:
IIR, through 2026.