Inspection history · 62
23 July 2026
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8442390
5 March 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8314851
7 May 2025
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8126471
20 February 2025
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8082149
6 May 2024
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7902941
22 February 2024
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7869345
22 February 2024
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7869349
21 August 2023
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7773067
22 May 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7691179
12 August 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7540711
9 June 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7221766
26 May 2021
In-Service Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7207180
23 May 2021
Administrative Inspection · Permit to Proceed
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7203816
23 May 2021
Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7218490
26 April 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7531509
16 January 2021
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7126020
13 August 2020
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7031639
20 December 2019
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6877187
13 May 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6683058
30 January 2019
Initial Certification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6617202
14 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6511894
18 September 2017
Industry Initiated Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6342713
13 July 2016
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5939683
8 August 2015
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5211585
5 March 2014
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4810403
29 September 2013
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4738492
2 May 2012
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4313037
11 April 2012
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4286060
7 April 2012
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4284338
1 March 2012
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4254961
28 February 2012
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4253342
12 July 2011
Industry Initiated Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4118462
20 July 2010
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3801718
21 May 2010
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3746345
1 May 2010
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3731915
15 April 2010
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3717803
30 January 2010
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3672666
5 February 2009
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3492574
11 September 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3323256
29 April 2008
DAPI Audit
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 3194933
2 May 2007
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2926137
9 June 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2674787
6 June 2006
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2724226
11 March 2006
Type not recorded
No type recorded · USCGC CAPSTAN (WYTL 65601) · USCG East District (CGD-E) · Activity 2606583
5 December 2005
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2546694
5 December 2005
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2546861
29 July 2004
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2153383
16 March 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2025283
23 December 2003
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1968860
16 August 2000
Uninspected Towing Vessel
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 823813
19 June 2000
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 156052
18 June 2000
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 227923
7 June 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 15554
27 May 2000
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 9664
2 June 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 197763
2 June 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 756747
26 May 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 104190
23 June 1998
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 30680
16 December 1997
Uninspected Towing Vessel
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1121575
20 February 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 180486
10 September 1992
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 682733
6 August 1992
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 99679
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 6 May 2024
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: Auxiliary generator engine low lubricating oil pressure. No visual signal was detected at the operating station for the number 2 generator low oil pressure alarm. Corrected on the spot. 46 CFR 143.230
Action required: 10 - Deficiency Rectified
Due 6 May 2024
Resolved 6 May 2024
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 6 May 2024
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: Auxiliary generator engine low lubricating oil pressure;
Auxiliary generator engine high cooling water temperature. Audible and Visual alarm for both high water temp and low lube oil pressure for the number one generator were inop. Corrected on the spot. 46 CFR 143.230
Action required: 10 - Deficiency Rectified
Due 6 May 2024
Resolved 6 May 2024
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 6 May 2024
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: Auxiliary generator engine low lubricating oil pressure. 46 CFR 143.230
Action required: 10 - Deficiency Rectified
Due 6 May 2024
Resolved 6 May 2024
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 6 May 2024
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided:
Auxiliary generator engine high cooling water temperature. Audible and Visual alarm for high water temp on the number one generator was inop. Corrected on the spot. 46 CFR 143.230
Action required: 10 - Deficiency Rectified
Due 6 May 2024
Resolved 6 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 May 2024
Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped... with one or more spring-loaded relief valves. The total relieving capacity of such relief valves must prevent pressure from exceeding the MAWP, as established by the manufacturer, by more than 10 percent. 46 CFR 143.300
Action required: 10 - Deficiency Rectified
Due 6 May 2024
Resolved 6 May 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 May 2024
Resolved
A vessel restricted in her ability to maneuver shall exhibit: Three shapes in a vertical line where they can best be seen. The highest and lowest of these shapes shall be balls and the middle one a diamond; Vessel did not have day shapes on board; Replace missing day shapes to the satisfaction of the attending CGMI. 33 CFR 88.27(b)(ii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2024
Resolved 13 May 2024
Resolution: O/O provided sufficient evidence of new dayshapes on board; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2024
Resolved
A 40-B portable fire extinguisher must be located near the storage room or cabinet. This is in addition to the portable fire extinguishers required by tables 142.230(a) and 142.230(b) of this part. Flame locker on 02 deck did not have a 40B extinguisher nearby or in the vicinity of the locker. Corrected on the spot. 46 CFR 142.225(d)
Action required: 10 - Deficiency Rectified
Due 6 May 2024
Resolved 6 May 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 May 2024
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight function properly. Gasket material was missing on a 2" section of the stbd fidley hatch. Replace the gasket to the satisfaction of the attending CGMI. 46 CFR 140.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2024
Resolved 13 May 2024
Resolution: O/O provided sufficient evidence of gaskets replaced; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2024
Resolved
For towing vessels with berthing aboard, a sufficient number of extra lifejackets must be carried so that a lifejacket is immediately available for persons at each manned watch station. corrected on the spot. 46 CFR 141.340(b)
Action required: 10 - Deficiency Rectified
Due 6 May 2024
Resolved 6 May 2024
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 August 2023
Resolved
A towing vessel that is: Certificated for rivers, lakes, bays, and sounds... must be equipped with either an approved 160-B semi-portable fire extinguishing system to protect the engine room, or a fixed fire extinguishing system installed to protect the engine room. Vessels fixed fire fighting system hoses are not serviceable and require replacement.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 21 August 2023
Resolved 22 August 2023
Resolution: Hiller replaced hoses.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 June 2021
Resolved
Electrical equipment must be suitable for a wet environment. Ventilation shut down switch on fixed fighting system connection wires are loss and exposed to the environment.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 June 2021
Resolved 9 June 2021
Resolution: Verified testing and repair cert from contracted repair person.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 June 2021
Resolved
All fire-suppression systems must be maintained in accordance with manufacturer's approved design. CO2 discharge nozzle under STBD reduction gear missing bell nozzle.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 June 2021
Resolved 9 June 2021
Resolution: Verified testing and repair cert from contracted repair person.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 9 June 2021
Resolved
Vessel structure is to be maintained as designed. STBD engine room watertight door frame is the be welded in place as designed. Provide repair plan for bulkhead repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2021
Resolved 16 June 2021
Resolution: [name withheld] attended vessel to verify weld plan.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 June 2021
Resolved
Vessel's engine room watertight door gaskets are worn and fail to provide appropriate watertight seal.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2021
Resolved 16 June 2021
Resolution: [name withheld] attended vessel to verify replacement.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 April 2019
Resolved
The fixed fire pump must be capable of delivering water [...] at a pressure of at least 50 psi. Vessel's fixed fire pump produces 30 psi of water pressure. Repair or replace, meeting the requirements of the referenced cite, and test the vessel's fire pump/fire main to the satisfaction of a USCG marine inspector. Vessel may utilize backup portable fire pumps in the interim.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2019
Resolved 23 May 2019
Resolution: Witnessed operational test of the vessel's newly installed fixed fire pump. Fire pump pressure gauge reading above 70 psi.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 19 April 2019
Resolved
Essential systems (steering) must be regularly tested and examined. Examinations must verify that the equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced. The port side rudder stop is bent and set back beyond its designed installation. Repair the rudder stop to accepted design standard and conduct a steering test to the satisfaction of a USCG marine inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2019
Resolved 13 May 2019
Resolution: The port side rudder stop has been repaired to original design standard. MI witnessed an operational test of the steering system.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 19 April 2019
Resolved
The remote fuel shutoff valve, required by the referenced cite, must be operable from a safe place outside of the fuel oil supply tank. During the test of the remote shutoff valve pull station, it was found to be seized and inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 April 2019
Resolved 19 April 2019
Resolution: Crew was given additional time to make repairs. Satisfactory operation of the pull station was observed by a USCG marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 April 2019
Resolved
The towing vessel must carry a combination of (6) day and (6) night visual distress signals. Vessel was missing (2) day/night visual distress signals.
Action required: 10 - Deficiency Rectified
Due 19 April 2019
Resolved 19 April 2019
Resolution: Vessel's crew acquired additional (2) dual purpose night/day distress signals.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 April 2019
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists [...] to include a high bilge level alarm. During the test of the high level bilge alarm it was found to be inoperative.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 19 April 2019
Resolved 19 April 2019
Resolution: Vessel's crew was given additional time to make repairs. It was discovered that the bilge alarm was wired incorrectly. The high bilge level alarm was repaired and tested to the satisfaction of the USCG marine inspector.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 April 2019
Resolved
The towing vessel must be equipped with [day] shapes in accordance with 33 CFR 84 (Inland Navigation Rules). The vessel does not have any day shapes on-board. Acquire the appropriate day shapes to the satisfaction of a USCG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2019
Resolved 13 May 2019
Resolution: Vessel has the required day shapes onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 April 2019
Resolved
Each lifebuoy on a towing vessel must be marked in block letters with the name of the vessel. The lifebuoys port and starboard of the wheelhouse were absent of the required marking. Mark as required to the satisfaction of a USCG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2019
Resolved 13 May 2019
Resolution: Lifebouys have been labeled with the vessel's name.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 April 2019
Resolved
Each pyrotechnic distress signal portable watertight container [...] must be clearly marked in legible contrasting letters at least 0.5 inches high with "DISTRESS SIGNALS". The portable watertight container was absent of the required marking. Mark as required to the satisfaction of a USCG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2019
Resolved 13 May 2019
Resolution: Vessel's portable watertight container has been labeled with "DISTRESS SIGNALS" as required.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 April 2019
Resolved
Flammable or combustible products on-board a towing vessel must be stored in a designated storage room or locker when not in use. Multiple flammable liquids were stored on a shelf located on the starboard side of the engine room.
Action required: 10 - Deficiency Rectified
Due 19 April 2019
Resolved 19 April 2019
Resolution: Vessel crew relocated the liquids to the approved locker located on the 01 deck to the satisfaction of the USCG marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 April 2019
Resolved
Each towing vessel must carry at least one appropriately sized lifejacket (see referenced cite for approval numbers) for each person on-board. Through a combination of (1) unserviceable lifejacket, faded retro-reflective material, and the mislabeling of the vessel's name; the vessel only had (3) of the required (7) lifejackets onboard.
Action required: 10 - Deficiency Rectified
Due 19 April 2019
Resolved 19 April 2019
Resolution: Vessel's crew acquired (7) new lifejackets to the satisfaction of the marine inspector.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 August 2018
Resolved
The vessel is currently broadcasting (1) Zero Draft, (2) Improper IMO
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 September 2018
Resolved 6 March 2019
Resolution: Owner reported AIS discrepancies corrected. Used NAVCEN to verify accuracy of vessel's AIS broadcast.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 24 April 2008
Resolved
Company did not do DOT required background check in the past on new employees, representative DER at the audit was under the impression that having new employees take a pre-employment drug test fulfilled the requirements. Was told by DAPI that all employees need to have a background check done who were there latest hires.
Due 14 May 2008
Resolved 12 May 2008
Resolution: [name withheld], Vulcans, Manager, Safety Health and Environmental submitted necessary documentation with plan of action for future program management.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 24 April 2008
Resolved
EAP Requirements- Training is required for Supervisory positions on the Vessel. Supervisor receive 1 hour EAP training needed.
Due 14 May 2008
Resolved 12 May 2008
Resolution: [name withheld], Vulcans, Manager, Safety Health and Environmental submitted necessary documentation with plan of action for future program management.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 24 April 2008
Resolved
Company did show proof of Alcohol Testing Kits. DER and Safety person showed a sample of a drug
Testing kit that would be used for a serious marine incident testing, not incompliance with the applicable regulations.
Due 14 May 2008
Resolved 12 May 2008
Resolution: [name withheld], Vulcans, Manager, Safety Health and Environmental submitted necessary documentation with plan of action for future program management.